Modbus Integration Module

Modbus Integration Module
Modbus Integration Module
Product Data Sheet
The Modbus Integration Module enables RF Code’s Sensor Manager and
Asset Manager applications to publish sensor information via the Modbus
TCP/IP protocol.
Features & Benefits
ŠŠ Works with Asset
Manager and Sensor
Manager
ŠŠ Software definable
Modbus Slave Devices
ŠŠ Fully Modbus TCP/IP
compliant
ŠŠ Compatible with most
Building Management
Systems
The Modbus Integration Module for Asset
Manager and Sensor Manager, available
as a separately purchasable item from RF
Code and RF Code resellers, allows any
Modbus TCP/IP compliant application
(Modbus Masters) to consume RF Code
sensor information. Through the use of the
Modbus TCP/IP protocol, all RF Code
wire-free sensor information -- such as
temperature, humidity, door position, dry
contact and fluid detection -- can be easily
utilized by Modbus Master applications.
The Modbus Integration Module creates
one or more Modbus Slave Devices, which
are accessible via the TCP/IP protocol.
Once installed, the Sensor Manager or
Asset Manager administrator uses the
Modbus Integration Module configuration
panels to setup and publish specific sensor
information. The Modbus Integration
Module configuration enables setup and
customization of the following:
•
Modbus Slave Server:
•
Global enable or disable
•
TCP/IP port number
•
Modbus Slave Devices:
•
Creation and configuration of one
or more slave devices
•
Selection of attributes from
Sensor Manager or Asset Manager
that will be associated to the slave
devices
•
User defined filtering capabilities
that controls specific groups or
sets of attributes that will be
published
•
Modbus Slave Addresses:
•
Provides an address mapping
table that specifies RF Code
sensor value/Modbus Index,
Slave ID, and Address mapping
information for easy configuration
in consuming Modbus Master
applications
•
Allows for easy exporting of
the Modbus Slave Addresses to
popular formats such as XML,
CSV and PDF
RF Code Modbus Integration Module Specifications
•
The Modbus Integration Module requires Asset Manager or Sensor Manager version 2.3 or higher.
Modbus Integration Module Screen Shots
Copyright © 2010 RF Code, Inc. All Rights Res
and/or other countries. All other trademarks are the property of their respective owners.
11/16/2010
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF