Regency L965E Gas Fireplace SpecSheet

Add to my manuals
5 Pages

advertisement

Regency L965E  Gas Fireplace SpecSheet | Manualzz

Model

Fuel Type

Minimum Supply Pressure

Manifold Pressure - High

Manifold Pressure - Low

Orifice Size Altitude 0-4500 ft.

Minimum Input

Altitude 0-4500 ft. (0-1372m)

Maximum Input

Altitude 0-4500 ft. (0-1372m)

Vent Sizing

L965E-NG10

Natural Gas

5” W.C. (1.25 kPa)

3.5” W.C. (0.87 kPa)

1.6” W.C. (0.41 kPa)

#45 DMS - Left

#41 DMS - Right

16,000 BTU/h

(4.68 kW)

48,000 BTU/h

(14.07 kW)

5”x 8”

Gas Fireplaces

L965E-10 Gas Fireplace

L965E-LP10

Propane

12” W.C. (2.98 kPa)

10” W.C. (2.48 kPa)

6.4” W.C. (1.59 kPa)

#55 DMS - Left

#53 DMS - Right

17,000 BTU/h

(4.98 kW)

48,000 BTU/h

(14.07 kW)

5”x 8”

NON-COMBUSTIBLE MATERIAL ZONE:

5-1/4"

(133mm)

24”

(610mm)

18-3/4"

(476mm)

27-3/4”

(705mm)

52-5/16"

(1329mm) 5-1/4"

(133mm)

18-3/4"

(476mm)

24”

(610mm)

52-5/16”

(1329mm)

11”

(279mm)

27-3/4”

(705mm)

52-5/16"

(1329mm)

52-5/16”

(1329mm)

11”

(279mm)

L965E-10 Gas Fireplace

FRAMING:

Gas Fireplaces

INTERNAL CHASE:

Hearth Protector

Figure 5. Typical Framing for Internal Chase - General.

24"

(610mm)

Min. Chase Depth

44-3/4"

(1137mm)

Minimum

63"

(1600mm) to centerline

52-5/16"

(1329mm)

To Header

52-5/16"

(1329mm)

Minimum

Gas Fireplaces

EXTERNAL CHASE:

Non-Combustible Facing and Hearth Protector

Dimensions:

Facing (supplied)

1 Top = 46” x 19”

2 Sides = 32-15/16 x 4-9/16”

Hearth Protector (supplied)

46” x 12”

NOTE: No hearth is required if the unit is raised a minimum of 18” off the floor.

L965E-10 Gas Fireplace

44-3/4"

(1137mm)

Minimum

Hearth Protector

Figure 7. Typical Framing for External Chase - General.

24"

(610mm)

Min. Chase Depth

63"

(1600mm) to centerline

52-5/16"

(1329mm)

To Header

Figure 8. Typical Framing for External Chase - Detailed.

L965E-10 Gas Fireplace

FRAMING FOR SIDEWALLS AND MANTEL:

Gas Fireplaces

The mantel’s maximum overhang is 10” (254mm) at the minimum height of 52¼” (1327mm) measured from the base of the fireplace.

The mantel can extend 1” (25.4mm) further for every 1”

(25.4mm) of height it is installed over the minimum height, as shown in Figure 12.

Non-combustible mantels and mantel legs are not limited to these dimensions.

Mantel temperatures are monitored during testing and can reach 117°F (47°C) above room temperatures. Make sure the finish on your mantel is suitable for temperatures of this range.

A wood trim can overhang a maximum of 1-1/4”deep and 14-1/2” in height from the top of the unit as shown in figures 11 and 12.

Mantel Clearances

44-3/4"(1 137mm )

Minimum

Framing Width

51-3/4" (1314mm)

Minimum

Fireplace Base to

Combustible Mantel

Gas Fireplaces

L965E-10 Gas Fireplace

ALLOWABLE VENT CONFIGURATIONS:

The vent chart, in Figure 23, illustrates the vent configurations that have been tested and approved for use with this appliance. 45˚ elbows are acceptable for this installation and may be used instead of 90˚ elbows. You may use two (2. 45˚ elbows for every 90˚ elbow shown in this chart.

This appliance is also approved for use with 5” x 8” flex venting. For durability, safety and resistance to corrosion, we recommend you use a flex venting made from aluminium. Only use flexible venting that is approved for fireplace applications. Flex vent runs must comply with the same limitations as the rigid vent chart shown here. Flexible vent runs greater than 8’ total are not recommended. Mixed vent runs of both Flexible and rigid venting are allowed providing all the proper connectors are utilized. See your vent providers’ catalogue for flex to rigid or rigid to flex adaptor numbers.

The restrictor settings shown in Figure 23, are recommended. Installation factors such as altitude, prevailing weather conditions such as temperature or wind, or the number of elbows used may affect your final restrictor settings. Insufficient restriction may cause pilot outages or reduced efficiencies. Too much restriction may lead to elevated operating temperatures, poor flame appearances, sooting or carbon deposits building up on burner effects or window glass.

Only use the restrictors supplied with this appliance.

40’ (12.19m)

35’ (10.67m)

30’ (9.14m)

25’ (7.62m)

20’ (6.10m)

* Horizontal Vent Sections rise 1 / 4 ”/ft (21mm/m) *

Table 1: Vent Restrictor Sizes.

%

Restriction

40%

50%

60%

70%

80%

Ø of Flue

Restrictor

3.878”

(98.5mm)

3.540”

(89.9mm)

3.166”

(80.4mm)

2.742”

(69.6mm)

2.239”

(56.9mm)

15’ (4.57m)

9’6” (2.90m)

5’3” (1.60m)

Figure 23. Allowable Vent Configurations Chart.