Model
Fuel Type
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size Altitude 0-4500 ft.
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
L965E-NG10
Natural Gas
5” W.C. (1.25 kPa)
3.5” W.C. (0.87 kPa)
1.6” W.C. (0.41 kPa)
#45 DMS - Left
#41 DMS - Right
16,000 BTU/h
(4.68 kW)
48,000 BTU/h
(14.07 kW)
5”x 8”
Gas Fireplaces
L965E-10 Gas Fireplace
L965E-LP10
Propane
12” W.C. (2.98 kPa)
10” W.C. (2.48 kPa)
6.4” W.C. (1.59 kPa)
#55 DMS - Left
#53 DMS - Right
17,000 BTU/h
(4.98 kW)
48,000 BTU/h
(14.07 kW)
5”x 8”
NON-COMBUSTIBLE MATERIAL ZONE:
5-1/4"
(133mm)
24”
(610mm)
18-3/4"
(476mm)
27-3/4”
(705mm)
52-5/16"
(1329mm) 5-1/4"
(133mm)
18-3/4"
(476mm)
24”
(610mm)
52-5/16”
(1329mm)
11”
(279mm)
27-3/4”
(705mm)
52-5/16"
(1329mm)
52-5/16”
(1329mm)
11”
(279mm)
L965E-10 Gas Fireplace
FRAMING:
Gas Fireplaces
INTERNAL CHASE:
Hearth Protector
Figure 5. Typical Framing for Internal Chase - General.
24"
(610mm)
Min. Chase Depth
44-3/4"
(1137mm)
Minimum
63"
(1600mm) to centerline
52-5/16"
(1329mm)
To Header
52-5/16"
(1329mm)
Minimum
Gas Fireplaces
EXTERNAL CHASE:
Non-Combustible Facing and Hearth Protector
Dimensions:
Facing (supplied)
1 Top = 46” x 19”
2 Sides = 32-15/16 x 4-9/16”
Hearth Protector (supplied)
46” x 12”
NOTE: No hearth is required if the unit is raised a minimum of 18” off the floor.
L965E-10 Gas Fireplace
44-3/4"
(1137mm)
Minimum
Hearth Protector
Figure 7. Typical Framing for External Chase - General.
24"
(610mm)
Min. Chase Depth
63"
(1600mm) to centerline
52-5/16"
(1329mm)
To Header
Figure 8. Typical Framing for External Chase - Detailed.
L965E-10 Gas Fireplace
FRAMING FOR SIDEWALLS AND MANTEL:
Gas Fireplaces
The mantel’s maximum overhang is 10” (254mm) at the minimum height of 52¼” (1327mm) measured from the base of the fireplace.
The mantel can extend 1” (25.4mm) further for every 1”
(25.4mm) of height it is installed over the minimum height, as shown in Figure 12.
Non-combustible mantels and mantel legs are not limited to these dimensions.
Mantel temperatures are monitored during testing and can reach 117°F (47°C) above room temperatures. Make sure the finish on your mantel is suitable for temperatures of this range.
A wood trim can overhang a maximum of 1-1/4”deep and 14-1/2” in height from the top of the unit as shown in figures 11 and 12.
Mantel Clearances
44-3/4"(1 137mm )
Minimum
Framing Width
51-3/4" (1314mm)
Minimum
Fireplace Base to
Combustible Mantel
Gas Fireplaces
L965E-10 Gas Fireplace
ALLOWABLE VENT CONFIGURATIONS:
The vent chart, in Figure 23, illustrates the vent configurations that have been tested and approved for use with this appliance. 45˚ elbows are acceptable for this installation and may be used instead of 90˚ elbows. You may use two (2. 45˚ elbows for every 90˚ elbow shown in this chart.
This appliance is also approved for use with 5” x 8” flex venting. For durability, safety and resistance to corrosion, we recommend you use a flex venting made from aluminium. Only use flexible venting that is approved for fireplace applications. Flex vent runs must comply with the same limitations as the rigid vent chart shown here. Flexible vent runs greater than 8’ total are not recommended. Mixed vent runs of both Flexible and rigid venting are allowed providing all the proper connectors are utilized. See your vent providers’ catalogue for flex to rigid or rigid to flex adaptor numbers.
The restrictor settings shown in Figure 23, are recommended. Installation factors such as altitude, prevailing weather conditions such as temperature or wind, or the number of elbows used may affect your final restrictor settings. Insufficient restriction may cause pilot outages or reduced efficiencies. Too much restriction may lead to elevated operating temperatures, poor flame appearances, sooting or carbon deposits building up on burner effects or window glass.
Only use the restrictors supplied with this appliance.
40’ (12.19m)
35’ (10.67m)
30’ (9.14m)
25’ (7.62m)
20’ (6.10m)
* Horizontal Vent Sections rise 1 / 4 ”/ft (21mm/m) *
Table 1: Vent Restrictor Sizes.
%
Restriction
40%
50%
60%
70%
80%
Ø of Flue
Restrictor
3.878”
(98.5mm)
3.540”
(89.9mm)
3.166”
(80.4mm)
2.742”
(69.6mm)
2.239”
(56.9mm)
15’ (4.57m)
9’6” (2.90m)
5’3” (1.60m)
Figure 23. Allowable Vent Configurations Chart.