POWR-FLITE LIMITED WARRANTY
Powr-Flite will repair or exchange parts for your dryer in the event of a manufacturing defect as follows:
This warranty covers normal use and does not cover damage which occurs in
shipment or failure resulting from alteration, accident, misuse, abuse, neglect, or
improper maintenance.
PARTS: New or comparable rebuilt parts, for one year after original purchase.
LABOR: Carry-in service can be obtained during the warranty period by taking
your dryer to an Authorized Powr-Flite Warranty Service Center.
IMPORTANT WARRANTY CONDITIONS: A purchase receipt or other proof of
date of original consumer purchase also will be required before warranty service
is rendered.
X9191 08.05
STATEMENT: This warranty is not transferable and extends only to the original
purchaser when a new Powr-Flite dryer is purchased from an Authorized PowrFite Dealer. This warranty gives you specific legal rights, and you may have
other rights that vary from state to state.
A Tacony Company, Fort Worth, Texas 76140-1710, Call Toll-Free (800) 880-2913
©Powr-Flite, All Rights Reserved
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE
USING THIS APPLIANCE
Do not handle plug or appliance with wet
hands.
When using an electrical appliance, basic precautions should always be followed.
Do not put any object into openings. Do not
use with any opening blocked; keep free of
dust, hair and anything that may reduce air
flow.
WARNING- To reduce the risk of fire, electric
shock or injury:
Turn off all controls before unplugging.
Use only as described in this manual. Use
only manufacturer’s recommended components and attachments.
Do not attempt to service the unit while appliance is plugged in.
Use only indoors. Do not use outdoors or
expose to rain.
Do not use with damaged cord or plug. If
appliance is not working as it should, has
been dropped, damaged, left outdoors, or
dropped into water, return it to your Authorized
Powr-Flite dealer.
Do no pull or carry by cord, use cord as a
handle, close door on cord, or pull cord
around sharp edges or corners. Keep cord
away from heated surfaces.
Appliance may cause a fire when operating
near flammable vapors or materials. Do not
operate this machine near flammable fluids,
dust or vapors.
Connect to a properly grounded outlet.
Do not use with any solid state speed control
device.
This unit is thermally protected.
WARNING
Do not stack dryers more than
4 (four) units high for transport,
5 (five) units high for storage.
Do not unplug by pulling on cord. To unplug,
grasp the plug, not the cord.
GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should malfunction or break down, grounding
provides a path of least resistance for electric current to reduce the risk of electric
shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that
is properly installed and grounded in accordance with all local codes and ordinances.
This appliance is for use on a nominal 120 volt circuit and has a ground plug (see
illustration, right). Make sure that the appliance is connected to an outlet having the
same configuration as the plug. No adaptor should be used with this appliance.
WARNING - Improper connection of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified electrician or service person if you
are in doubt as to whether the outlet is properly grounded. Do not modify the plug
provided with the appliance – if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
Grounded
Outlet
Prong or
Grounding pin
Grounded
Outlet Box
FOR BEST PERFORMANCE
• Keep machine clean and in good operating condition.
• Store machine carefully in dry area.
• Have machine checked periodically by your Authorized
Powr-Flite Dealer.
• For optimum drying performance and safety, study and
follow your operators manual.
• Use only authorized service centers for parts or service.
SAVE THESE INSTRUCTIONS
OPERATING
1.
2.
3.
4.
INSTRUCTIONS
Plug in to a standard outlet with the correct voltage and amperage for the unit.
Place the dryer in the desired operating position.
Set the switch at the desired speed: low or high.
Check for proper operation before leaving the unit unattended.
Do not move or carry the dryer when it is running.
Daisy-chained: Up to 6 units may be plugged into on a single 15 amp circuit and
up to 9 on a 20 amp circuit. The F5 is equipped with dual power outlets that will
allow you to “daisy chain” up to 5 units units. Do not “daisy chain” more than 5 units.
The F5 power system has a 12 amp circuit breaker built in that will trip if more than 5
units are “daisy chained” from a single machine.
12 AMP Resettable Circuit Breaker
The F5 Powr-Dryer features a 12 amp circuit breaker that will “trip” if more than 12
amps of electrical current is drawn through the cord.
2 postion switch and daisy-chained outlets
GFCI Protection and Outlet
The F5 Powr-Dryer provides a standard duplex GFCI outlet for daisy-chaining multiple units together. The GFCI protection promotes operator safety and will “trip” is an
electrical ground fault is sensed. To test the GFCI protection, press the TEST button.
If operating properly, the RESET button on the GFCI outlet will pop out.
Operating Positions
The F5 Powr-Dryer is designed to operate in multiple positions for any type of drying.
1. Tilt Back – Tilt the F5 backward on the four curved molded legs at an angle
to direct air for elevated drying.
2. Upright – Set the F5 square with the handle on the top to direct air across
a room.
3. Tilt Forward – Tilt the F5 forward on the “standing legs at an angle to direct
airflow along the flow in front of the dryer.
4. Face Down – Set the F5 on the four curved molded legs with the “standing
legs” facing up to direct air straight down.
5. Powr Pitch – Model PDF5 is equipped with a 3º down angle leg.
6. Stack for Storage – the F5 Powr-Dryer interlock and stack for easy
storage and transport.
Cord wrap
MAINTENANCE/TROUBLE SHOOTING
Periodic Maintenance
1. Check power cord for any breaks, seperations or cuts.
2. Make sure the ground pin or grounding prong is intact or
the machine will be unsafe to operate.
Trouble Shooting (if the dryer will not run)
1. Check electrical cord; is it firmly seated in wall outlet
2. Check GFCI and reset if tripped
3. Check if dryer circuit breaker is tripped, reset if necessary.
4. Check to see if building circuit breaker is tripped. If circuit
is overloaded, move cord to different GFCI outlet.
5. If using an extension cord, make sure it is in good
condition, proper gauge and firmly connected.
ASSEMBLY
For model PDF5DX only
PDF5C caster kit
Parts for PDF5, PDF5C, PDF5DX
ref#
01
02
03
04
05
06
07
08
09
10
11
12
13
14
part #
X9180
PD3C
X9098
X8260
72719A
X9183
X9189
X9195
P50
72020A
X9181
X8209
X9065
X8990N
description
Housing, Axial Fan
Foot, Black Rubber, Short
Screw, #10 x 1”, A point, Pan Head
Nut, 8-32 Lock, w/ Nylon Inserts
Bracket, Axial Fan Motor
Grill Axial Fan
Label, Round (at grill)
Caster Receiver
Wheel and Socket
Screw, Self-Tap, PHMS, Zinc, #12 x 1”
Motor, 115 VAC, .25 HP, 4-Pole
Screw, 1/4-20 x 1/2", Self Locking Flange
Screw, Hex Socket Cap, 1/4-20 x 1"
Handle / Wheel Assembly, Narrow
ref#
15
16
17
18
19
20
21
22
23
24
25
26
27
28
part #
X8848
X9190
72721A
X9048
X918
X9188
X8926
PD8
X8008N
X9187
X9182
F631
72470A
PD3B
description
Jacknut, 1/4-20, Steel, #8LJN
Label, Product
Switch Panel
Rocker Switch
Circuit Breaker, 12A
Screw, 6-32 x 3/8”, Black MS
20’ HD, 3-wire cord, 16/3 SJTW, 115 volts
Strain Relief, 1/2" NPT
Nut, Lock, 1/2" Steel Conduit
GFCI outlet, Female Plug
Fan Blade Assembly
Round Belt
Heat Shrink, Blk, 1/2” x 200’,
Foot, Black Rubber, Tall
Use PD3C for units with handle / wheel assembly (PDF5DX)
X9191 08.05
©Powr-Flite, All Rights Reserved
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement