wd_frico_pa4200_it

wd_frico_pa4200_it
Thermozone® PA4200
Schemi di collegamento
Schema dei collegamenti interni
PA4200 A
4215A/4220A/4225A
3515A/3520A/3525A
4210A
3510A
°C
°C
°C
°C
White
White
SIReB1
C2
Internal Motor
sensor protection
Blue
Actuator
230V~
Black
Supply
230V~
230V~
PA4200 E
4215E/4220E/4225E
3515E/3520E/3525E
4210E
3510E
°C
°C
4210E/4215E
3510E/3515E
°C
°C
White
N
N
400V3~
400V3~
White
SIReB1
C2
Internal Motor
sensor protection
Actuator
230V~
Black
Grey
Blue
Yellow
Orange
Red
Brown
Black
Green
Blue
230V
200V
170V
145V
120V
100V
N
Transformer
ROOM
Black
Transformer
C1
230V
200V
170V
145V
120V
100V
N
Blue
Supply
230V~
230V~
4220E/4225E
3520E/3525E
230V
200V
170V
145V
120V
100V
N
Transformer
ROOM
Yellow
Orange
Red
Brown
Black
Green
Blue
Transformer
C1
230V
200V
170V
145V
120V
100V
N
Thermozone® PA4200
Schemi di collegamento
Schema dei collegamenti interni
PA4200 W
4215W/4220W/4225W
3515W/3520W/3525W
°C
4210W
3510W
°C
°C
°C
White
White
SIReB1
C2
Internal Motor
sensor protection
Actuator
230V~
Supply
230V~
230V~
Yellow
Orange
Red
Brown
Black
Green
Blue
230V
200V
170V
145V
120V
100V
N
Transformer
ROOM
Blue
Black
Transformer
C1
230V
200V
170V
145V
120V
100V
N
Thermozone® PA4200
Schemi di collegamento
Opzioni di controllo per le unità senza riscaldamento
SIReB Basic
SIReB1
SIReUB1
SIReB Basic - Collegamento in parallelo
SIReB1
SIReB1
SIReUB1
Thermozone® PA4200
Schemi di collegamento
Opzioni di controllo per le unità senza riscaldamento
SIReAC Competent
SIReC1X
SIReB1
C2
Pot.
X5
Unit ID
C1
X4
COM 1
ROOM
X3
ROOM
COM 2
N L PE PE N L
7 8 9 10
1112
15 161718
SIReDC
19 20
SIReUA1
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
EXTERNAL ON/OFF, 5-30V AC/DC
EXTERNAL RPM 0-10V DC IN
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
ON/OFF (potential free contact)
SIReAC Competent - Collegamento in parallelo
SIReB1
Pot.
Unit ID
Pot.
Unit ID
SIReB1
C2
Pot.
X5
Unit ID
C1
X4
ROOM
X3
ACTUATOR SUPPLY
N L PE PE N L
SIReC1X
COM 1
COM 2
ROOM
BUS
7 8 9 10
1112
15 161718
19 20
SIReUA1
SIReB1
SIReDC
N L PE PE N
SIReB1
C2
Pot.
X5
Unit ID
C1
X4
ROOM
X3
ACTUATOR SUPPLY
N L PE PE N L
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
ACTUATOR SUPPLY
EXTERNAL ON/OFF, 5-30V AC/DC
ROOM
X3
EXTERNAL RPM 0-10V DC IN
C1
X4
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
ON/OFF (potential free contact)
Pot.
Unit ID
C2
X5
Thermozone® PA4200
Schemi di collegamento
Opzioni di controllo per le unità con riscaldamento elettrico
SIReB Basic
SIReB1
SIReRTX
(optional)
230V~
X5
C2
X4
C1
SIReUB1
PE N L
SUPPLY 230V
ACTUATOR
230V
X3
ROOM
SIReB Basic - Collegamento in parallelo
SIReB1
SIReB1
230V~
230V~
X5
C2
X4
C1
X3
ROOM
PE N L
SUPPLY 230V
ACTUATOR
230V
X5
C2
X4
C1
X3
ROOM
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReRTX
(optional)
SIReUB1
Thermozone® PA4200
Schemi di collegamento
Opzioni di controllo per le unità con riscaldamento elettrico
SIReAC Competent
PE N L
SUPPLY 230V
ACTUATOR
230V
X3
ROOM
X4
C1
X5
C2
SIReRTX
(optional)
SIReC1X
SIReB1
C2
Pot.
Unit ID X5
C1
X4
ROOM
X3
COM 1
230V~
ROOM
COM 2
N L PE PE N L
1112
7 8 9 10
15 161718
19 20
SIReDC
SIReUA1
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
EXTERNAL ON/OFF, 5-30V AC/DC
EXTERNAL RPM 0-10V DC IN
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
ON/OFF (potential free contact)
SIReAC Competent - Collegamento in parallelo
SIReB1
Pot.
Unit ID
X5
C2
X4
C1
X3
ROOM
Pot.
Unit ID
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReRTX
SIReB1
230V~
C2
Pot.
X5
Unit ID
C1
X4
ROOM
X3
SIReC1X
ACTUATOR SUPPLY
N L PE PE N L
COM 1
COM 2
ROOM
BUS
7 8 9 10
1112
15 161718
19 20
SIReUA1
SIReB1
SIReDC
230V~
N L PE PE N L
SIReB1
230V~
C2
Pot.
X5
Unit ID
C1
X4
ROOM
X3
ACTUATOR SUPPLY
N L PE PE N L
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
ACTUATOR SUPPLY
EXTERNAL ON/OFF, 5-30V AC/DC
ROOM
X3
EXTERNAL RPM 0-10V DC IN
C1
X4
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
ON/OFF (potential free contact)
Pot.
Unit ID
C2
X5
Thermozone® PA4200
Schemi di collegamento
Opzioni di controllo per le unità con riscaldamento elettrico
SIReAA Advanced
X3
ROOM
X4
C1
X5
C2
ACTUATOR
230V
SIReUA1
SIReB1
230V~
C2
Pot.
X5
Unit ID
ROOM
X3
C1
X4
SIReRTX
ACTUATOR SUPPLY
SIReA1X
N L PE PE N L
COM 1
COM 2
ROOM
BUS
1 2 3 4 5 6 7 8 9 10
111213 1415 161718
19 20
21 22
SIReDC
SIReOTX
BMS INDICATION OUT
(potential free contact
max 3A, 230V)
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
EXTERNAL ON/OFF, 5-30V AC/DC
EXTERNAL HEAT 0-10V DC IN
EXTERNAL RPM 0-10V DC IN
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
on/off (potential free contact)
HEAT INDICATION
0-10V DC out (max 5 mA)
RPM INDICATION
0-10V DC out (max 5 mA)
SIReAA Advanced - Collegamento in parallelo
SIReB1
Pot.
Unit ID
X5
C2
X4
C1
X3
ROOM
Pot.
Unit ID
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReUA1
SIReB1
SIReRTX
230V~
Pot.
Unit ID
C2
X5
C1
X4
ROOM
X3
SIReA1X
ACTUATOR SUPPLY
N L PE PE N L
COM 1
SIReB1
COM 2
ROOM
BUS
1 2 3 4 5 6 7 8 9 10
111213 1415 161718
19 20
21 22
230V~
C2
Pot.
X5
Unit ID
C1
X4
ROOM
X3
SIReDC
ACTUATOR SUPPLY
BMS INDICATION OUT
(potential free contact
max 3A, 230V)
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
N L PE PE N L
EXTERNAL ON/OFF, 5-30V AC/DC
ACTUATOR SUPPLY
EXTERNAL RPM 0-10V DC IN
ROOM
X3
EXTERNAL HEAT 0-10V DC IN
C1
X4
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
on/off (potential free contact)
230V~
C2
Pot.
X5
Unit ID
HEAT INDICATION
0-10V DC out (max 5 mA)
SIReB1
RPM INDICATION
0-10V DC out (max 5 mA)
N L PE PE N L
SIReOTX
Thermozone® PA4200
Schemi di collegamento
Opzioni di controllo per le unità con riscaldamento ad acqua
SIReB Basic
SIReB1
SIReSD230
X4
C1
X5
C2
X3
ROOM
SIReRTX
(optional)
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReUB1
C
SIReB Basic - Collegamento in parallelo
SIReB1
SIReSD230
X5
C2
X4
C1
X3
ROOM
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReB1
SIReSD230
X5
C2
X4
C1
X3
ROOM
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReB1
SIReSD230
X5
C2
X4
C1
X3
ROOM
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReRTX
(optional)
SIReUB1
Thermozone® PA4200
Schemi di collegamento
Opzioni di controllo per le unità con riscaldamento ad acqua
SIReAC Competent
X5
C2
X4
C1
PE N L
SUPPLY 230V
ACTUATOR
230V
X3
ROOM
SIReRTX
(optional)
SIReC1X
SIReB1
C2
Pot.
X5
Unit ID
SIReSD230
ROOM
X3
C1
X4
PE N
N L L
~
L
COM 1
ROOM
COM 2
7 8 9 10
1112
+ -
19 20
15 161718
SIReDC
SIReUA1
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
EXTERNAL ON/OFF
5-30V AC/DC
EXTERNAL RPM 0-10V DC IN
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
ON/OFF (potential free contact)
SIReAC Competent - Collegamento in parallelo
X5
C2
X4
C1
X3
ROOM
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReB1
C2
Pot.
X5
Unit ID
SIReSD230
C1
X4
ROOM
X3
ACTUATOR SUPPLY
N L L PE N L
~
SIReB1
C2
Pot.
X5
Unit ID
SIReSD230
C1
X4
ROOM
X3
ACTUATOR SUPPLY
SIReRTX
(optional)
SIReC1X
N L L PE N L
~
COM 1
ROOM
COM 2
7 8 9 10
SIReB1
15 161718
19 20
SIReSD230
ALARM OUT (BMS)
(potential free contact,max 3A, 230V)
~
DOOR CONTACT
(potential free contact)
N L L PE N L
EXTERNAL ON/OFF, 5-30V AC/DC
ACTUATOR SUPPLY
EXTERNAL RPM 0-10V DC IN
ROOM
X3
EXTERNAL ALARM IN
(potential free contact)
C1
X4
EXTERNAL SETBACK TEMP.
ON/OFF (potential free contact)
C2
Pot.
X5
Unit ID
1112
SIReUA1
Thermozone® PA4200
Schemi di collegamento
Opzioni di controllo per le unità con riscaldamento ad acqua
SIReAA Advanced
X4
C1
X5
C2
X3
ROOM
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReUA1
SIReB1
C2
Pot.
X5
Unit ID
ROOM
X3
C1
X4
SIReRTX
SIReWTA
ACTUATOR SUPPLY
N L L PE N L
SIReA1X
~
COM 1
COM 2
ROOM
BUS
1 2 3 4 5 6 7 8 9 10
21 22
19 20
111213 1415 161718
Blue
White
SIReDC
SIReST23024
SIReOTX
SIReSDM24
BMS INDICATION OUT
(potential free contact
max 3A, 230V)
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
EXTERNAL ON/OFF, 5-30V AC/DC
EXTERNAL HEAT 0-10V DC IN
EXTERNAL RPM 0-10V DC IN
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
on/off (potential free contact)
RPM INDICATION
0-10V DC out (max 5 mA)
Blue
White
Red
Black
SIReAA Advanced - Collegamento in parallelo
SIReUA1
X5
C2
X3
ROOM
X4
C1
PE N L
SUPPLY 230V
ACTUATOR
230V
SIReST23024
SIReB1
C1
X4
ROOM
X3
SIReRTX
ACTUATOR SUPPLY
N L L PE N L
~
24V
Blue
White
Red
Black
C2
Pot.
X5
Unit ID
SIReSDM24
Red
Black
COM 1
SIReST23024
SIReB1
ROOM
X3
ACTUATOR SUPPLY
N L L PE N L
~
24V
ROOM
111213 1415 161718
19 20
21 22
BMS INDICATION OUT
(potential free contact
max 3A, 230V)
ALARM OUT (BMS)
(potential free contact,
max 3A, 230V)
EXTERNAL ON/OFF, 5-30V AC/DC
EXTERNAL HEAT 0-10V DC IN
24V
EXTERNAL RPM 0-10V DC IN
SIReWTA
~
SIReDC
EXTERNAL ALARM IN
(potential free contact)
EXTERNAL SETBACK TEMP.
on/off (potential free contact)
ROOM
X3
ACTUATOR SUPPLY
N L L PE N L
SIReSDM24
Blue
White
Red
Black
C1
X4
1 2 3 4 5 6 7 8 9 10
RPM INDICATION
0-10V DC out (max 5 mA)
Red
Black
SIReST23024
SIReB1
C2
Pot.
X5
Unit ID
BUS
Blue
White
C1
X4
SIReSDM24
COM 2
Blue
White
Red
Black
C2
Pot.
X5
Unit ID
SIReA1X
SIReOTX
Red
Black