2000 Series Inverted Bucket Steam Trap All Stainless Steel With 360° Connector/IS-2/TVS-4000 Steam Trapping and Steam Tracing Equipment For Pressures to 650 psig (45 bar)...Capacities to 1,300 lb/hr (590 kg/hr) Description How to Order • A sealed, tamperproof package • A compact, lightweight trap • The ability to withstand freeze-ups without damage • Exceptional corrosion resistance • A three-year guarantee against defective materials, defective workmanship. For a fully detailed certified drawing, refer to: 2000 Series with Standard Connector CD #1003 2000 Series with IS-2 Conncector CD #1113 With the 2000 Series’ 360° universal connector, you can install inverted bucket efficiency and long service life in any piping configuration with little or no repiping. You get the reliability of the inverted bucket operating principle, plus all the benefits of all-stainless steel construction: Specify: • Model number • Size and type of pipe connection • Type of 360° connector (with or without strainer) • Maximum working pressure that will be encountered or orifice size • Any options required Allow 2-1/2'' clearance for bolt installation and removal. 2000 Series steam traps combine savings in three important areas: energy, installation and replacement. The 360° universal connector provides quick, easy in-line replacement along with all the proven advantages of inverted bucket operation. Allow 2-1/2'' clearance for trap installation and removal. E F Also available with optional IS-2 integral strainer connector. Maximum Operating Conditions Maximum allowable pressure (vessel design): Model 2010, 2011: 400 psig @ 800°F Model 2022: 650 psig @ 600°F 627 psig @ 700°F 600 psig @ 800°F Maximum operating pressure: Model 2010: 200 psig (14 bar) Model 2011: 400 psig (28 bar) Model 2022: 650 psig (45 bar) C (28 (45 (43 (41 bar bar bar bar @ @ @ @ 427°C) 315°C) 371°C) 427°C) B D A Model 2011 Trap With Standard Connector Connections E F Screwed NPT and BSPT Socketweld Flanged (consult factory) C 2" WITHDRAWAL LENGTH Materials Body: ASTM-A 240 Grade 304L Internals: All stainless steel—304 Valve and seat: Hardened chrome steel—17-4PH or Titanium Connector body (std & IS-2): Stainless steel—304 Flange ASTM A105 Zinc plated D B 1/4" Plug Options A • Insu-Pak™ insulation for Models 2010/2011 • Stainless steel pop drain for Models 2011/2022 • Probe connection for Models 2011/2022 • Strainer blowdown valve for IS-2 connector • Wiggle wire Series 2010-2022 With IS-2 Connector 2000 Series Traps With Standard Connector Model No. 2010 Pipe Connections 360° Connector Styles • Standard connector • IS-2 connector with integral strainer • IS-2 connector with integral strainer with blowdown valve “A” (Diameter) “B” (Height) Specification Inverted bucket steam trap, type ... in all stainless steel, freeze resistant, with 360° universal connector, having continuous air venting at steam temperature, free-floating stainless steel mechanism, and orifice at the top of the trap. 2011 2022 in mm in mm in mm 1/2, 3/4 15, 20 1/2, 3/4 15, 20 1/2, 3/4 15, 20 2-11/16 68 2-11/16 68 3-7/8 98 6 152 6-15/16 176 8-11/16 221 “C” (Face to Face) 2-3/8 60 2-3/8 60 2-3/8 60 “D” (Bottom to CL) 4-19/32 117 5-9/16 141 7-3/8 187 “E” (CL to Outside) 146 4-9/16 115 4-9/16 115 5-3/4 “F” (CL to Bolt) 1 25 1 25 1 Weight lb (kg) 4-1/4 (1.9) 4-1/2 (2.0) 25 7 (3) 2000 Series Traps With IS-2 Integral Strainer Connector Model No. 2011 2022 mm in mm in mm in mm in mm in mm 1/2, 3/4 15, 20 1 25 1/2, 3/4 15, 20 1 25 1/2, 3/4 15, 20 1 25 “A” (Diameter) 2-11/16 68 2-11/16 68 2-11/16 68 2-11/16 68 3-7/8 98 3-7/8 98 “B” (Height)* 6 152 6 152 6-15/16 176 6-15/16 176 8-11/16 221 8-11/16 221 Pipe Connections “C” (Face to Face) 3-1/2 89 4 102 3-1/2 89 4 102 3-1/2 89 4 102 “D” (Bottom to CL)* 5 127 5 127 6 152 6 152 7-3/4 197 7-3/4 197 “E” (Outside to Bolt) 5-1/2 140 5-11/16 144 5-1/2 140 5-11/16 144 6-11/16 170 6-7/8 175 “F” (CL to Outside) 4-5/8 117 4-13/16 122 4-5/8 117 4-13/16 122 5-13/16 148 6 152 Weight lb (kg) 104 2010 in 4-3/4 (2.2) 5-1/4 (2.4) 5 (2.3) 5-1/2 (2.5) 7 (3) *Add 1/2" (15 mm) to “B” and “D” dimensions when optional probe connection is required. Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com for up-to-date information. North America • Latin America • India • Europe / Middle East / Africa • China • Pacific Rim armstronginternational.com 2000 Series Inverted Bucket Steam Trap All Stainless Steel With 360° Connector/IS-2/TVS-4000 For Pressures to 650 psig (45 bar)...Capacities to 1,300 lb/hr (590 kg/hr) Model 2011 Capacity 1 2 5 3 7 10 700 500 250 Capacity lb/hr 400 150 100 #38 200 200 70 150 50 100 40 #38 R60* 70 Capacity kg/hr Capacity lb/hr 250 400 250 7/64 200 2022 Trap #38 300 250 100 10 2 3 5 7 Pressure, psi 100 2 5/64 150 100 70 50 5 7 10 2 5 3 7 100 2 5 3 Pressure, psi Model 2022 Capacity Pressure, bar 5 3 7 1 2 5 3 7 10 2 5 3 1,500 *NOTE: Because the orifice is located at the top, inverted bucket steam traps handle dirt and scale better than other types of traps. However, in applications where extremely dirty conditions exist, care should be exercised in the use of all types of restricted-orifice, reduced-capacity traps. Connectors Besides the inverted bucket traps, the standard connector, IS-2 connector, and TVS-4000 connector with integral strainer can also be used on thermostatic, thermostatic wafer and disc traps. 500 1,000 400 700 300 250 7/64 500 200 400 #38 150 300 250 100 200 70 150 100 5 7 650 300 Capacity lb/hr 7 400 250 400 300 10 5 200 150 15 25 125 3 2 5/32 1/8 20 30 10 7 70 500 25 40 5 3 200 30 50 2 700 200 300 Pressure, bar 1 1,000 300 200 7 5 2 Capacity kg/hr 7 Capacity kg/hr Pressure, bar 5 3 Steam Trapping and Steam Tracing Equipment Model 2010 Capacity 50 7 10 2 3 5 7 100 2 3 5 7 1,000 Pressure, psi CD-3300 Disc Trap With IS-2 Integral Strainer Connector Options Pop Drain for Freeze Protection Valve In general, a properly selected and Retainer installed Armstrong trap will not freeze SS as long as steam is coming to the Polished trap. If the steam supply is shut off, Ball a pop drain should be used to automatically drain the trap. Stainless steel pop drain available for Models 2011 O-Ring and 2022. Maximum Operating Conditions Pressure: 600 psig (41 bar) Temperature: 350°F (177°C) Body Spring Insu-Pak Now you can insulate the in-line traps in your plant without complicating regular trap maintenance. Insu-Pak, a simple reusable insulation package, cuts the time and cost of in-field installation because it goes on in a snap. And it comes off just as easily. The Insu-Pak can prevent trap freeze-up when used with a properly designed condensate manifold. Designed for use with Model 2010 and Model 2011 traps. Probe connections are available for trap monitoring for Models 2011 and 2022. Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit armstronginternational.com for up-to-date information. Next North America • Latin America • India • Europe / Middle East / Africa • China • Pacific Rim armstronginternational.com 105
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement