Installation Instructions
Radionics
™
D9535 Passive Infrared
Intrusion Detector
• Select a location that is most likely to intercept an intruder moving
across the coverage pattern.
1.0 Specifications
• Input Power: 9 to 15 VDC; 15 mA @ 12 VDC.
• Standby Power: There is no internal standby battery. Connect to
DC power sources capable of supplying standby power if primary
power fails. Fifteen mA-H required for each hour of standby time
needed. Four hours (60 mA-H) minimum are required for
Underwriters Laboratories' Certificated installations.
• Coverage:
Standard Broad
Barrier (Optional)
Long Range (Optional)
Pet Alley (Optional)
35 ft. by 35 ft.
(10.7 m by 10.7 m)
35 ft. by 10 ft.
(10.7 m by 3.1 m)
70 ft. by 10 ft.
(21.4 m by 3.1 m)
35 ft. by 35 ft.
(10.7 m by 10.7 m)
with 70 ft. (21.4 m) Long Range
• The recommended mounting height range is 6.5 ft. to 8.5 ft. (2 m
to 2.6 m).
Note: The mounting surface should be solid and vibration free.
• Remove the cover. Insert a thin flathead screwdriver into the
notch at the bottom of the cover and pry up.
• Remove the circuit board by depressing the circuit board retainer
tab and lifting the board out from the enclosure. Then remove the
mirror by sliding it towards the bottom and out of its tracks.
• Open the knock-out wire entrance and route the wiring through.
Surface or Corner Mounting
• Open 2 holes for surface or corner mounting.
• Sensitivity: Standard or Intermediate.
• Alarm Relay: Normally Closed reed relay with contacts rated at 3
watts, 28 VDC, 125 mA maximum for DC resistive loads.
• Mark the location for the mounting screws using the enclosure as
a template.
• Pre-start the mounting screws.
• Tamper Switch: Normally Closed (with cover in place) tamper
switch. Contacts rated at 3 watts, 28 VDC, 125 mA maximum.
• Firmly mount the detector.
• Temperature: The storage and operating range is -40° to +120°F
(-40° to +49°C). For U. L. Certificated installations, the range is
+32° to +120 °F (0 ° to +49° C).
Select the Vertical Angle
• Options: B335-3* Low Profile Swivel Mount Bracket, OMB93-3*
Barrier Mirror, OMLR93-3* Long Range Mirror, and the OMP93-3*
Pet Alley Mirror. *Shipped in packages of three.
Note: Misalignment of the detector when using an optional
mounting bracket may reduce range.
• Replace the circuit board and mirror.
The angle adjust markings are on the mirror. Slide the mirror forward
or back until the angle hash marks are in-line with the markers on
each side of the frame.
+2
0
-8
-16
• U. S. Patent Number: # 4,764,755.
Mirror
2.0 Mounting
This chart will help you set the correct Vertical Angle based on the
mounting height, mirror type, and desired range.
Wiring
Knockouts
T-Strip
Circuit Board
Retainer Tabs (2)
Program
Plugs
Tamper Switch
Location of major items - Circuit Board
Corner
Mounting
Holes (2)
Rear enclosure and mounting holes
Things to Avoid/Remember
Avoid
Broad
20(6) 35(10)
Barrier
Long Range
20(6) 35(10) 40(12) 70(20)
-2°
6.5(2)
-9°
-5°
-9°
-5°
-4°
7.5(2.3)
-11°
-7°
-11°
-7°
-6°
-3°
8.5(2.6)
-14°
-8°
-14°
-8°
-7°
-4°
Mirror
Tracks (2)
Bracket Mounting
Hole
Surface
Mounting
Holes (4)
LED
Height and desired Range listed in feet (meters)
The mirror is adjustable +2° to -18° vertically. To change the mirror,
just pull it out from its resting grooves.
Note: Excessive handling of the mirror surfaces may lead to
performance degradation.
3.0 Wiring
Direct hot and/or cold drafts. Windows. Small animals.
Air conditioning outlets. Heat sources. Direct sunlight.
Remember
Won’t detect through glass. Best catch performance
is across the pattern. When using two or more
detectors, cross patterns for best coverage.
P/N 31364B
Mounting
Height
CAUTION: Only apply power after all
connections have been made
and inspected.
• Connect wiring as shown.
D9535 Installation Instructions
Page 1
1
2
-
+
3
4
5
6
7
NC C SP T T
© 1996 Radionics
Terminal Descriptions
• 1 (–) & 2 (+): Input power. Use no smaller than #22 AWG (0.8
mm) wire pair.
• 3, 4: Normally Closed reed relay contacts rated at 3 Watts, 125
mA, 28 VDC maximum for DC resistive loads and protected by a
4.7 ohm resistor in the common “C” leg of the relay. Do not use
with capacitive or inductive loads.
• Masking: Before attempting any masking, be sure the chosen
mirror surface is the correct one. When attempting to remove any
masking, many adhesives will either destroy the mirror surface or
leave enough residue behind to reduce coverage performance.
See Section 8.0 Mirror Segment to Pattern Reference.
7.0 Instructions for Installations Containing Pets
The Pet Alley Mirror is intended to provide protection in installations
where pets are allowed to move about freely.
• 5: Spare.
• 6 & 7: Tamper Contact, rated 3 watts, 28 VDC, 125 mA.
Note: If using the large wiring knockout, seal the wire entrance
with the foam plug provided. If using the round four
conductor wiring knockout, the plug is not required
Note: Do not coil excess wiring inside the detector.
4.0 Program Plugs
The following functions are controlled by various settings of the
program plugs:
• Because the unit will be installed lower than normal, be sure to
position the unit so that it has a clear line-of-sight across the room.
• To provide an accurate safety margin, install the unit no lower than
twice the height of the pet, and never lower than 3 ft. (1 m).
• Make sure the field of view is free of all furniture or other objects
on which the pet could climb or jump, resulting in an unwanted
alarm.
8.0 Coverage Patterns
ON
(Default)
• LED Operation:
• Adjust the Vertical Angle to 0° when using the Pet Alley Mirror.
Broad Coverage
Top View
OFF
- ON: Allows the LED to operate
LED Jumpers
when activated by alarm.
- OFF: The LED will not operate
STD
INT
on alarm. The LED will indicate
Standard (Default)
a supervision trouble condition
STD
even if this plug is OFF.
INT
18
0 Meters
10
A
B
J
O
P
Q
F
e
e0
t
D
K
E0
L
M
F
N
Intermediate
• Sensitivity Mode:
Sensitivity
- Standard: The recommended Jumpers
setting for maximum false alarm
immunity. Tolerates environmental extremes on this setting.
Standard Sensitivity is not recommended for Long Range
or Barrier type patterns. The detector is shipped in Standard
Sensitivity mode.
- Intermediate: The recommended setting for any location where
an intruder is expected to cover only a small portion of the
protected area or when quick catch performance is desired.
Tolerates normal environments on this setting. This setting will
improve your intruder catch performance.
Mirror Segment
to Pattern Reference
M
e
t
e
r
s
P
J K L M N
H
18
I
0 Feet
Q
O
G
5
35
A B C D E F G H I
Side View
F 10
e
e 5
t 0
0Meters
10
0 Feet
35
O-Q
A-I
J-N
M
e
t
e
r
s
3
0
Mirror adjusted to -5°
Barrier Coverage
Top View
F
e
e
t
5
0 Meters
10
1.5
K I
G
H
L J
0
5
E
F
C
A
D
B
0
1.5
35
0 Feet
M
e
t
e
r
s
Mirror Segment
to Pattern Reference
K
I
5.0 Setup and Walk Testing
10
5
0
0 Meters
10
3
0 Feet
0
35
K-L I-J G-H
C-D
E-F
G
H
C
D
A
B
E
Side View
F
e
e
t
• Replace the cover and insert the tamper screw
(if desired).
• Apply power to the unit.
• Wait for approximately 2 minutes (if no motion
is detected in the coverage pattern), then start
walk testing.
- Walk test across the coverage pattern.
• The edge of the coverage is determined by
activation of the LED.
• Walk test the unit from both directions to
determine the boundaries.
• If the desired range can not be achieved, angle the mirror up or
down to assure the coverage pattern is not aimed too high or low.
5
C
M
e
t
e
r
s
L
J
F
A-B
Mirror adjusted to -5°
5
F
e
e
t
Long Range Coverage
Top View
0 Meters
20
0
5
1.5 M
0
1.5
0 Feet
10
F
e
e
t
E
D
0
0 Feet
E
D
C
B
A
C
B
3 M
5
0
Mirror Segment
to Pattern Reference
70
20
Side View
0 Meters
e
t
e
r
s
e
t
e
r
s
A
70
Mirror adjusted to -2°
Pet Alley Coverage
Top View
0 Meters
20
A
21
6
B
C
Mirror Segment
to Pattern Reference
D
E
0 ft.
0m
F
6.0 Other Information
G
A B C D E F G H I
H
• Maintenance: At least once a year, the range and coverage
should be checked in accordance with the Walk Testing section.
To ensure continual daily operation, the end user should be
instructed to daily walk through the outer edge of the coverage
pattern and observe the LED operation (if used). This assures an
alarm output prior to arming.
20
0 Feet
0 Meters
10
I
Side View
5
6
70
21
1.5 m
0
0 Feet
70
Mirror adjusted to 0°
© 1996 Radionics, Inc., Salinas, CA, U.S.A. All rights reserved.