FPDL7-13

FPDL7-13
FPDL7-13
SERIES D
COMPACT LAMP
Emergency
Lighting Equipment
INSTRUCTION MANUAL
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C.
power is supplied to the unit.
2. CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical
shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by disconnecting the unit connector.
3. CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace
the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly.
4. DO NOT USE OUTDOORS. The FPDL7-13 is for use with grounded, UL Listed, indoor fixtures. Not for use in
heated air outlets or hazardous locations.
5. The FPDL7-13 requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused
A.C. lead.
6. Do not mount near gas or electric heaters.
7. The FPDL7-13 should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
8. The FPDL7-13 will cold strike and operate one 5W, 7W, or 9W, twin tube, double twin tube, 180ma or 13W
twin tube, double twin tube, 285ma fluorescent lamp, each with a single lampholder per lamp.
9. The FPDL7-13 is for use with fluorescent downlight fixtures.
10. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
11. Do not use this equipment for other than intended use.
12. Install in accordance with the National Electrical Code and local regulations.
13. Installation and servicing should be performed by qualified personnel.
SAVE THESE INSTRUCTIONS
THIS UNIT CONTAINS A
RECHARGEABLE NICKELCADMIUM BATTERY. PLEASE
RECYCLE OR DISPOSE OF
PROPERLY.
INSTALLATION INSTRUCTIONS
CAUTION: Before installing, make certain the A.C. power is off and the
FPDL7-13 unit connector is disconnected.
1. MOUNTING THE FPDL7-13
When used with ceiling mounted downlight fixtures, the FPDL7-13 should be mounted on the fixture above the
ceiling. The flex conduit marked “A” should be wired into the ballast/lamp compartment or to an electrical junction
box on the fixture which allows access to the ballast/lamp connections. Refer to Illustration 1 for typical mounting.
When battery packs are remote mounted, the remote distance can not exceed 1/2 of the distance from ballast to
lamp specified by the A.C. ballast manufacturer. For example, if the A.C. ballast manufacturer recommends no
more than 25′ remote distance, then the battery pack should not exceed 121/2′. Under no circumstances should
the battery pack exceed a distance of 50′ from the lamp.
2. MOUNTING THE TEST SWITCH AND CHARGE INDICATOR LIGHT
Cut the single gang switch box into the ceiling tile adjacent to the fixture within reach of the FPDL7-13 flex
marked “B”. After mounting the switch box, connect flex “B” to the box and route all leads inside the box. Refer
to Illustration 1 for typical mounting. Connect the leads to the components as follows:
Red lead
(+) Charge light terminal
Wht/Red lead (–) Charge light terminal
White
*Wht/Blk lead Unit connector
White/Black
*Wht/Blk lead Unit connector
Test switch
* To prevent electrical shock and unintentional battery discharge, do not join the unit connector until the installation
is complete.
3. WIRING
A.The FPDL7-13 and A.C. ballast must be on the same branch circuit.
B.The FPDL7-13 requires an unswitched A.C. power source of either 120 or 277 volts; therefore, when used with switched fixtures, the FPDL7-13 input must be wired ahead of the switch.
C.Refer to the wiring diagrams on the back page for the proper wiring. For wiring diagrams of ballasts not shown,
consult our customer service.
Illustration 1
FLEX “A”
Downlight Fixture
FPDL7-13
A.C. BALLAST &
LAMP SOCKET COMPARTMENT
FLEX “B”
JUNCTION
BOX
SWITCH BOX
TEST SWITCH
CEILING
TILE
CHARGE LIGHT
INSURE WIRING IS IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL REGULATIONS.
Page 2
4. LABELS
Attach the appropriate labels adjacent to the Test Switch and Charge Indicator. Annotate Re-lamping label for
lamp type and wattage. The Caution and the Re-lamping labels must be on the fixture in a readily visible location
to anyone attempting to service the fixture.
5. COMPLETING INSTALLATION
A.When the installation is complete, switch the A.C. power on and join the FPDL7-13 unit connector.
OPERATION
General – This unit is primarily designed to be used with compact fluorescent lamp downlight fixtures. It will wire in conjunction with the existing A.C. ballast(s) and lamp(s) to provide the emergency function. It can also be wired for emergency only operation. The Test Switch and Charge Indicator light are offered in a standard single gang switch
box for installation adjacent to the fixture.
Normal Mode – A.C. power is present. The A.C. ballast operates the fluorescent lamp(s) as intended. The FPDL7-13
is in the standby charging mode. The Charge Indicator will be lit providing a visual indication that the battery is being
charged.
Emergency Mode – The A.C. power fails. The FPDL7-13 senses the A.C. power failure and automatically switches to
the Emergency Mode. One lamp is illuminated, at reduced output, for a minimum of 90 minutes. When the A.C. power is
restored, the FPDL7-13 switches the system back to the Normal Mode and resumes battery charging.
TESTING & MAINTENANCE
Initial Testing – Allow the unit to charge approximately 1 hour, then conduct a short discharge test by depressing the
test switch. The Charge Indicator light will go out and the fluorescent tube will be illuminated. When the FPDL7-13 is
used in fixtures with more than one A.C. ballast, the second A.C. ballast is NOT de-energized with the test switch. It
may, therefore, be advisable to switch the A.C. fixture power off prior to depressing the test switch. Allow a 24 hour
charge before conducting a one hour test.
The FPDL7-13 is a maintenance free unit, however, periodic inspection and testing is required. NFPA 101, Life Safety
Code, outlines the following schedule:
Monthly – Insure that the Charge Indicator light is illuminated. Conduct a 30 second discharge test by depressing the
Test Switch. One lamp should operate at reduced output.
Annually – Insure that the Charge Indicator light is illuminated. Conduct a full 11/2 hour discharge test. The unit should
operate as intended for the duration of the test.
“Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction.”
SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL.
Consult Customer Service for current warranty information.
Page 3
TYPICAL WIRING DIAGRAMS
For use with 2 pin, 5 through 13 watt lamps with integral starter only.
ONE LAMP MAGNETIC BALLAST
1.
ONE LAMP MAGNETIC BALLAST
ONE LAMP HIGH POWER FACTOR MAGNETIC BALLAST
2.
ONE LAMP HIGH POWER FACTOR MAGNETIC BALLAST
BLK (120V)
UNSWITCHED LINE
�
ORG (277V)
EMERGENCY
FPDL7-13
BALLAST
WHITE
COMMON
WHT/BLK
RED OR
RED/BLK(+)
BLUE/WHT
A.C.
BLACK
BLUE
BALLAST
SWITCHED OR
UNSWITCHED
LINE
TEST
SWITCH
WHITE
CHARGE
INDICATOR
BLUE
WHT/BLK
YEL/BLK
WHT/BLK
FLEX A
*LAMP
�
�
�
FLEX B
�
UNIT
CONNECTOR
A.C.
BLACK BALLAST
SWITCHED OR
UNSWITCHED
LINE
WHITE
FPDL7-13
BALLAST
WHT/BLK
RED OR
�
RED/BLK(+)
YELLOW
WHT/BLK
YEL/BLK
WHT/BLK
�
�
�
YELLOW
CHARGE
INDICATOR
WHT/BLK
WHT/BLK
YEL/BLK
*LAMP
�
�
FLEX B
�
UNIT
CONNECTOR
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
�
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
FLEX B
BLK (120V)
UNSWITCHED LINE
�
WHITE
ORG (277V)
EMERGENCY
FPDL7-13
BALLAST
WHITE
COMMON
WHT/BLK
CHARGE
INDICATOR
BLUE
*LAMP
�
BLUE
1LMB
TEST
SWITCH
WHT/RED
FLEX A
RED OR
RED/BLK(+)
WHT/RED
TWO LAMP ELECTRONIC BALLAST
BLUE/WHT
BLUE
A.C.
TEST
SWITCH
WHITE
WHT/BLK
4. TWO LAMP ELECTRONIC BALLAST
EMERGENCY
WHITE
RED
BLUE/WHT
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
WHT/BLK
WHITE
WHITE
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
BLK (120V)
COMMON
FPDL7-13
BALLAST
WHITE
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
ORG (277V)
EMERGENCY
FLEX A
ONE LAMP ELECTRONIC BALLAST
�
ORG (277V)
WHT/BLK
BLACK
BLUE
BALLAST
SWITCHED OR
UNSWITCHED
LINE
3. ONE LAMP ELECTRONIC BALLAST
UNSWITCHED LINE
�
COMMON
�
WHT/RED
YELLOW
BLK (120V)
UNSWITCHED LINE
WHT/BLK
�
UNIT
CONNECTOR
BLACK
BLUE/WHT
BLACK BALLAST WHITE
SWITCHED OR
UNSWITCHED
LINE
BLUE
WHITE
A.C.
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
YELLOW
WHT/BLK
YEL/BLK
WHT/BLK
LAMP
*LAMP
�
�
WHT
BLACK
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
�
*AC/EMERGENCY LAMP
CHARGE
INDICATOR
WHT/RED
FLEX A
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST 1LHPFMB
SWITCH
WHT/BLK
RED OR
RED/BLK(+)
�
FLEX B
�
UNIT
CONNECTOR
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
LAMP PARALLEL HIGH POWER FACTOR MAGNETIC BALLAST
6.TWO
TWO
LAMP PARALLEL HIGH POWER FACTOR MAGNETIC BALLAST
LAMP PARALLEL MAGNETIC BALLAST
5.TWO
TWO
LAMP PARALLEL MAGNETIC BALLAST
1LEB
BLK (120V)
UNSWITCHED LINE
�
WHITE
ORG (277V)
EMERGENCY
FPDL7-13
BALLAST
WHITE
COMMON
WHT/BLK
BLACK
SWITCHED OR
UNSWITCHED
LINE
BLUE/WHT
A.C.
BALLAST BLUE
WHT/BLK
RED OR
RED/BLK(+)
YELLOW
WHT/BLK
YEL/BLK
WHT/BLK
�
�
*LAMP
RED
*AC/EMERGENCY LAMP
�
FLEX B
�
CHARGE
INDICATOR
�
UNIT
CONNECTOR
WHITE
ORG (277V)
EMERGENCY
FPDL7-13
BALLAST
WHITE
COMMON
�
WHT/RED
BLK (120V)
UNSWITCHED LINE
BLUE
FLEX A
LAMP
TEST
SWITCH
WHT/BLK
WHITE
BLUE/WHT
A.C.
BLACK BALLAST
SWITCHED OR
UNSWITCHED
LINE
BLUE
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
�
�
*LAMP
*AC/EMERGENCY LAMP
WHT/BLK
�
FLEX B
�
UNIT
CONNECTOR
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
TWO LAMP SERIES HIGH POWER FACTOR MAGNETIC BALLAST
TWO LAMP SERIES MAGNETIC BALLAST
8. TWO LAMP SERIES HIGH POWER FACTOR MAGNETIC BALLAST
7. TWO LAMP SERIES MAGNETIC BALLAST
2LPMB
BLK (120V)
UNSWITCHED LINE
�
ORG (277V)
EMERGENCY
FPDL7-13
BALLAST
WHITE
COMMON
WHT/BLK
A.C.
BLACK BALLAST
SWITCHED OR
UNSWITCHED
LINE
BLUE
BLUE
WHT
BLUE/WHT
LAMP
WHITE
WHT/BLK
RED OR
�
RED/BLK(+)
YELLOW
WHT/BLK
YEL/BLK
WHT/BLK
*LAMP
*AC/EMERGENCY LAMP
TEST
SWITCH
WHT/RED
FLEX A
�
�
�
FLEX B
2LPHPFMB
BLK (120V)
UNSWITCHED LINE
�
ORG (277V)
EMERGENCY
FPDL7-13
BALLAST
WHITE
COMMON
WHT/BLK
CHARGE
INDICATOR
�
UNIT
CONNECTOR
WHITE
BLACK
SWITCHED OR
UNSWITCHED
LINE
*LAMP
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
RED
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
WHT/BLK
RED OR
RED/BLK(+) �
CHARGE
INDICATOR
WHT/BLK
WHT/BLK
YEL/BLK
LAMP
TEST
SWITCH
BLUE
YELLOW
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
WHITE
WHT/RED
BLUE/WHT
A.C.
BALLAST BLUE
FLEX A
*AC/EMERGENCY LAMP
2LSMB
Rev. 031306
68313-106
CHARGE
INDICATOR
WHT/BLK
YEL/BLK
BLUE
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
WHT/BLK
RED OR
�
RED/BLK(+)
WHT/RED
YELLOW
LAMP
2LEB
BLUE
FLEX A
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST
SWITCH
�
�
�
FLEX B
�
UNIT
CONNECTOR
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
2LSHPFMB
Page 4
TYPICAL WIRING DIAGRAMS
For use with 2 pin, 5 through 13 watt lamps with integral starter only.
TWO NORMAL POWER FACTOR MAGNETIC BALLASTS
9. TWO NORMAL POWER FACTOR MAGNETIC BALLASTS
BLK (120V)
UNSWITCHED LINE
�
ORG (277V)
EMERGENCY
FPDL7-13
WHITE
COMMON
BALLAST
WHT/BLK
SWITCHED OR
UNSWITCHED
LINE
BLACK
BLUE/WHT
A.C.
BALLAST BLUE
#1
CHARGE
INDICATOR
BLUE
YELLOW
WHT/BLK
WHT/BLK
FLEX A
A.C.
BALLAST BLUE
#2
�
WHT/RED
YEL/BLK
BLACK
TEST
SWITCH
WHITE
WHT/BLK
RED OR
RED/BLK(+)
LAMP
�
�
*LAMP
*AC/EMERGENCY LAMP
�
FLEX B
�
UNIT
CONNECTOR
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
2NPFMB
10. TWO HIGH
TWO HIGH
POWER FACTOR
MAGNETIC
BALLASTS
POWER
FACTOR
MAGNETIC
BALLASTS
BLK (120V)
UNSWITCHED LINE
�
ORG (277V)
EMERGENCY
FPDL7-13
WHITE
COMMON
BALLAST
WHT/BLK
WHITE
SWITCHED OR
UNSWITCHED
LINE
BLUE/WHT
A.C.
BLACK BALLAST BLUE
YELLOW
�
CHARGE
INDICATOR
WHT/BLK
WHT/BLK
FLEX A
A.C.
BALLAST BLUE
#2
WHT/BLK
RED OR
RED/BLK(+)
WHT/RED
YEL/BLK
BLACK
TEST
SWITCH
BLUE
#1
WHITE
WHITE
LAMP
�
�
*LAMP
*AC/EMERGENCY LAMP
�
FLEX B
�
UNIT
CONNECTOR
SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD
DO NOT MATE CONNECTOR UNTIL INSTALLATION
IS COMPLETE AND A.C. POWER IS SUPPLIED.
TEST ACCESSORY LEADS-REFER TO INSTALLATION
INSTRUCTIONS FOR PROPER POLARITY WIRING.
2HPFMB
Rev. 031306
68313-106
Page
Insert5
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising