Temperature / mA converter 9113B – Input for RTD, TC and mA – Active / passive mA output – 1 or 2 channels – Can be supplied separately or installed on power rail, PR type 9400 – SIL 2-certified via Full Assessment Advanced features • Configuration and monitoring by way of detachable display front (PR 4501); process calibration and signal simulation. • Copying of the configuration from one device to others of the same type via the display front. • TC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 / PR 5913Ex, channel 2) for higher accuracy. • The device automatically detects whether it must supply an active or a passive current signal. • Advanced monitoring of internal communication and stored data. • SIL 2 functionality is optional and must be activated in a menu point. Connections Application • The device can be mounted in the safe area and in zone 2 / cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I/II/III, Div. 1, Gr. A-G. • Conversion and scaling of temperature (Pt, Ni and TC) and active current signals. • The 9113 has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508. Technical characteristics • 1 green and 2 red front LEDs indicate operation status and malfunction. • 2.6 kVAC galvanic isolation between input, output and supply. Mounting • The devices can be mounted vertically or horizontally without distance between neighbouring units. This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability Environmental Conditions Specifications range....................................... Storage temperature...................................... Calibration temperature................................. Relative humidity............................................ Protection degree........................................... Installation in.................................................. -20°C to +60°C -20°C to +85°C 20...28°C < 95% RH (non-cond.) IP20 Pollution degree 2 & measurement / overvoltage cat. II 109 x 23.5 x 104 mm 109 x 23.5 x 116 / 131 mm 250 g 265 g / 350 g DIN EN 60715/35 mm 0.13...2.08 mm2 AWG 26...14 stranded wire Screw terminal torque.................................... 0.5 Nm Common specifications Supply voltage............................................... Fuse............................................................... Max. power consumption............................... Isolation voltage, test /working: Input to any.................................................... Analog output to supply................................. Status relay to supply..................................... Communications interface............................. Nom. 2 μA / 0 μA 0...20 mA 0...20 and 4...20 mA Nom. 20 Ω + PTC 50 Ω Programmable ON / OFF Output specifications Mechanical specifications Dimensions (HxWxD)..................................... Dimensions (HxWxD) w/ 4501 / 4511............................................................. Weight approx................................................ Weight incl. 4501 / 4511 (approx.)................. DIN rail type................................................... Wire size........................................................ Sensor error current: When detecting / else............................................... Current input: Measurement range.............................................................. Current input: Programmable measurement ranges..................................... Input resistance, current input............................................................... Sensor error detection, current input............................................................... 19.2...31.2 VDC 400 mA SB / 250 VAC ≤ 3.5 W (2 channels) 2.6 kVAC / 300 VAC reinforced isolation 2.6 kVAC / 300 VAC reinforced isolation 1.5 kVAC / 150 VAC reinforced isolation Communication enabler 4511 / Programming front 4501 Min. 60 dB (0...100 kHz) Signal / noise ratio......................................... Average response time incl. delay: Temperature input............................... ≤ 1 s mA input......................................................... ≤ 0.4 s Accuracy........................................................ Better than 0.1% of selected range EMC immunity influence................................ < ±0.5% of span Extended EMC immunity: NAMUR NE 21, A criterion, burst................................. < ±1% of span Input specifications Approvals EMC............................................................... EN 61326-1 LVD................................................................ EN 61010-1 ATEX.............................................................. KEMA 07ATEX0148 X IECEx............................................................. KEM 09.0052X FM.................................................................. 3038279-C INMETRO....................................................... NCC 12.1310 X UL................................................................... UL 61010-1 GOST R......................................................... Yes GOST Ex........................................................ Yes DNV Marine.................................................... Stand. f. Certific. No. 2.4 SIL.................................................................. SIL 2 certified & fully assessed acc. to IEC 61508 9113B-060614 RTD input....................................................... Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000 Cable resistance per wire (max.), RTD.................................................... 50 Ω Sensor current, RTD...................................... Nom. 0.2 mA Effect of sensor cable resistance (3-/4-wire), RTD............................................. < 0.002 Ω / Ω Sensor error detection, RTD.......................... Programmable ON / OFF TC input: Thermocouple type......................... B, E, J, K, L, N, R, S, T, U, W3, W5, LR Cold junction compensation (CJC) via ext. sensor in connector 5910.............................................. 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C CJC via internally mounted sensor............................................................ ±(2.0°C + 0.4°C * Δt) Δt =................................................................. Internal temperature-ambient temperature Sensor error detection, TC............................. Programmable ON or OFF (only wire breakage) Current output: Signal range......................... 0...20 mA Programmable signal ranges......................... 0...20 / 4...20 / 20...0 and 20...4 mA Load (max.).................................................... 20 mA/600 Ω/12 VDC Load stability, current output.......................... ≤0.01% of span/100 Ω Sensor error indication, current output............................................................. 0 / 3.5 / 23 mA / none NAMUR NE 43 Upscale/Downscale.............. 23 mA / 3.5 mA Output limitation, on 4...20 and 20...4 mA signals.................................... 3.8...20.5 mA Output limitation, on 0...20 and 20...0 mA signals.................................... 0...20.5 mA Current limit.................................................... ≤ 28 mA 2-wire 4…20 mA output: External 2-wire supply range........................................ 3.5...26 VDC Signal range................................................... 4…20 mA Max. load resistance [Ω]................................ (Vsupply - 3.5) / 0.023 A Load stability, 4…20 mA output..................... ≤ 0.01% of span / 100 Ω Effect of external 2-wire supply voltage variation................................. < 0.005% of span / V Max. voltage, status relay.............................. 110 VDC / 125 VAC Max. current, status relay............................... 0.3 ADC / 0.5 AAC Max. AC power, status relay.......................... 62.5 VA / 32 W *of span.......................................................... = of the currently selected measurement range
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement