HRPG-450
450W Single Output with PFC Function
■
•
•
•
•
•
•
•
•
•
•
•
•
•
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89.5%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
Built-in cooling Fan ON-OFF control
Built-in DC OK signal
Built-in remote ON-OFF control
Stand by 5V@0.3A
Built-in remote sense function
No load power consumption<0.5W (Note.7)
5 years warranty
SPECIFICATION
MODEL
OUTPUT
HRPG-450-3.3 HRPG-450-5
HRPG-450-7.5 HRPG-450-12 HRPG-450-15 HRPG-450-24 HRPG-450-36 HRPG-450-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
90A
90A
60A
37.5A
30A
18.8A
12.5A
9.5A
CURRENT RANGE
0 ~ 90A
0 ~ 90A
0 ~ 60A
0 ~ 37.5A
0 ~ 30A
0 ~ 18.8A
0 ~ 12.5A
0 ~ 9.5A
RATED POWER
297W
450W
450W
450W
450W
451.2W
450W
456W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p
120mVp-p
150mVp-p
150mVp-p
240mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
4.3 ~ 5.8V
±2.0%
6.8 ~ 9V
±2.0%
10.2 ~ 13.8V
±1.0%
13.5 ~ 18V
±1.0%
21.6 ~ 28.8V
±1.0%
28.8 ~ 39.6V
±1.0%
40.8 ~ 55.2V
±1.0%
2.8 ~ 3.8V
VOLTAGE TOLERANCE Note.3 ±2.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
LOAD REGULATION
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
1000ms, 100ms/230VAC
88%
89%
89.5%
41.4 ~ 48.6V
57.6 ~ 67.2V
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
16ms/230VAC
FUNCTION
16ms/115VAC at full load
Note.5 85 ~ 264VAC
120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
80%
83%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
5A/115VAC
35A/115VAC
2.4A/230VAC
70A/230VAC
LEAKAGE CURRENT
<1.5mA / 240VAC
OVERLOAD
PROTECTION
2500ms, 100ms/115VAC at full load
OVER VOLTAGE
PF>0.99/115VAC at full load
86.5%
88%
89%
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
6 ~ 7V
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
3.96 ~ 4.62V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
5V STANDBY
Shut down o/p voltage, recovers automatically after temperature goes down
5VSB : 5V@0.3A ; tolerance± 5%, ripple : 50mVp-p(max.)
DC OK SIGNAL
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
REMOTE CONTROL
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
FAN CONTROL (Typ.)
Load 20± 10% or RTH2≧50℃ Fan on
WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃ , 10 ~ 95% RH
TEMP. COEFFICIENT
± 0.03%/ ℃ (0 ~ 50℃ )
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
NOTE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
130.5K hrs min.
DIMENSION
218*105*41mm (L*W*H)
PACKING
1.19Kg; 12pcs/15.3Kg/0.82CUFT
MIL-HDBK-217F (25℃)
1.
2.
3.
4.
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Tolerance : includes set up tolerance, line regulation and load regulation.
The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. No load power consumption<0.5W when RC- & RC+ (CN100 pin1,2) 0 ~ 0.8V or short.
File Name:HRPG-450-SPEC 2014-01-29
HRPG-450
450W Single Output with PFC Function
Mechanical Specification
Case No. 995A
152.4
series
Unit:mm
32.8
O/P
1
2
Air flow
direction
3
FAN
4
I/P
5
6
1
2
4-M4 L=5
3
1
7
2
8
218
152.4
32.8
18max.
12max.
8-M4 L=4 (Both Sides)
AC Input Terminal Pin No.
Assignment
Pin No.
1
2
3
Connector Pin No. Assignment(CN100) : HRS DF11-8DP-2DS or equivalent
DC Output Terminal Pin No.
Assignment
Assignment
AC/L
AC/N
FG
Pin No.
1~3
4~6
Pin No.
1
2
3
4
Assignment
-V
+V
Assignment
RC+
RCAUX
AUXG
Pin No.
5
6
7
8
Assignment
DC-OK
GND
+S
-S
Mating Housing
HRS DF11-8DS HRS DF11-**SC
or equivalent
or equivalent
Block Diagram
PMW fosc : 70KHz
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
Terminal
RECTIFIERS
&
PFC
AUX
POWER
RECTIFIERS
&
FILTER
AUX
AUXG
+S
POWER
SWITCHING
RECTIFIERS
&
FILTER
+V
-V
-S
DETECTION
CIRCUIT
O.L.P.
O.T.P.
FG
DC OK
O.T.P.
PFC
CONTROL
PWM
CONTROL
Derating Curve
O.V.P.
RC+
REMOTE
CONTROL
RC-
Output Derating VS Input Voltage
100
125
90
100
80
80
70
60
50
50
20
-40
40
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
70
(HORIZONTAL)
85
100
125
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:HRPG-450-SPEC 2014-01-29
HRPG-450
450W Single Output with PFC Function
series
Function Description of CN100
Pin No. Function Description
1
RC+ Turns the output on and off by electrical or dry contact between pin 2 (RC-), Short: Power OFF, Open: Power ON.
RC- Remote control ground.
2
Auxiliary voltage output, 4.75~5.25V, referenced to pin 4(AUXG). The maximum load current is 0.3A. This output is not controlled by the
3
AUX "remote ON/OFF control".
4
5
6
7
8
AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
DC-OK DC-OK Signal is a TTL level signal, referenced to pin6(DC-OK GND). High when PSU turns on.
GND This pin connects to the negative terminal(-V). Return for DC-OK signal output.
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
+S
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
-S
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Function Manual
1.Remote Sense
The remote sensing compensates voltage drop on
the load wiring up to 0.5V.
CN100
CN100
2
1
8
7
2
RC- RC+ 1
AUXG AUX
GND DC-OK
8
+S
(Pin7)
+
LO AD
F ig 1. 1
-S
+S
7
-S
(Pin8)
Sense l ines should
be twi sted in pairs
2.DC-OK Signal
DC-OK signal is a TTL level signal. High when PSU turns on.
Between DC-OK(pin5) and GND(pin6)
CN100
Output Status
CN100
3.3 ~ 5.6V
ON
0 ~ 1V
OFF
2
1
8
7
2
RC- RC+ 1
AUXG AUX
GND DC-OK
8
-S
+S
7
F ig 2. 1
3.Remote Control
The PSU can be turned ON/OFF by using the
"Remote Control" function.
Between RC+(pin1) and RC-(pin2)
Output Status
SW ON (Short)
OFF
SW OFF (Open)
ON
CN100
2
1
8
7
1
2
CN100
RC- RC+
AUXG AUX
GND DC-OK
8
-S
+S
7
SW
F ig 3. 1
File Name:HRPG-450-SPEC 2014-01-29
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising