ISDN-MOD

ISDN-MOD
®
ISDN Module
USER MANUAL
Program version 1.06
isdn_en 08/08
IMPORTANT
The equipment requires an external 12 V DC power supply unit with 500mA current capacity.
Making any construction changes or unauthorized repairs is prohibited.
Prior to putting the equipment into operation, please read this manual carefully.
The mainboard of ISDN module contains electronics sensitive to electrostatic discharge. Prior
to installation, remove the electrostatic charge, and be careful not to touch any components
on the module board during the installation.
Incorrect configuration of the ISDN module may result in generation of unwanted telephone
calls and, consequently, it may increase the equipment operating costs.
DECLARATION OF CONFORMITY
SATEL spółka z o.o.
ul. Schuberta 79
80-172 Gdańsk, POLAND
tel. (+48 58) 320-94-00
fax. (+48 58) 320-94-01
Product description: The ISDN module is a device suitable for interaction with the ISDN network on S/T
interface. It works as a TA (terminal adapter) type of equipment, enabling devices designed for operation
with analog telephone lines to be connected to the ISDN network.
The product is in conformity with the following EU Directives:
LVD
73/23/EEC+93/68/EEC
EMC 89/336/EWG + 91/263/EEC, 92/31EEC, 93/68/EEC
R&TTE 1999/5/EC
The product meets the requirements of harmonized standards:
LVD:
PN – EN 4100:2001
EMC: ETSI EN 300 386: v.1.3.2:2003; ETSI EN 300 386-2: v.1.1.3:1997
R&TTE: TBR3; ETSI ETS 300 012 (1992) + A2 (1996); ETSI ETS 300 153 (1992) + A1 (1995)
[NET 3 part 1]; ETSI ETS 300 104 (1991) +A 1 (1994) [NET 3 part 2].
Conformity with requirements of the Directives has been established on the basis of tests
conducted in the accredited laboratories: regarding the EMC&LVD Directives: in the Testing Laboratory,
Dept. of Electrical Engineering Institute, Gdańsk; regarding the R&TTE Directives: in the Teleinformatic
Equipment Testing Laboratory, Communication Institute, Warsaw, the Laboratory seated in Gdańsk.
LVD report No.:
133/LBS – 845/2004
EMC report No.:
129/LMC – 845/2004
R&TTE report No.:
08 50 0014 + technical opinion 207/2004
Head of Test Laboratory:
Gdańsk, Poland
01.10.2004
Michał Konarski
Latest EC declaration of conformity and certificates are available for downloading on website www.satel.pl
Product:
ISDN module
Manufacturer:
CONTENTS
1. Module Features.................................................................................................................. 2
2. Module Description.............................................................................................................. 2
3. Connecting the module........................................................................................................ 3
3.1 Connecting the power supply....................................................................................................3
3.2 Connecting the alarm control panel ..........................................................................................3
3.3 Connecting the module to ISDN network ..................................................................................5
3.3.1
3.3.2
4.
5.
6.
7.
8.
Preparation for work in point-to-multipoint configuration ....................................................................5
Preparation for work in point-to-point configuration ............................................................................8
Equipment Factory Settings................................................................................................. 8
Modification of ISDN Module Settings with AT Commands ................................................. 9
AT Commands Accepted by ISDN Module.......................................................................... 9
Technical data ................................................................................................................... 11
History of the manual updates ........................................................................................... 11
2
SATEL
ISDN Module
1. Module Features
• Operation as a terminal adapter, which enables the alarm control panel to be connected to
an ISDN line without any changes in configuration of the panel or the monitoring station.
• Option to work in configurations "point-to-multipoint" and "point-to-point".
• Option to use the same ISDN line, to which other ISDN equipment is connected (e.g.
telephones, faxes, modems).
• Option to set priority for connections initiated by the control panel.
• Monitoring for presence of ISDN line.
• Support of tone dialing.
• Digital data transmission in V.110 format in case the equipment is used as an external
modem.
• Configuration by means of AT commands sent through the RS-232 port if the equipment is
used as an external digital modem.
• 12V DC supply, typical for the alarm & security systems.
2. Module Description
Figure 1. View of ISDN module electronics board.
ISDN Module
SATEL
3
Legend to Fig. 1:
1 – RS-232 connectors
2 – RJ-45 connector, designated ISDN-IN – ISDN telephone line input;
3 – RJ-45 connector, designated ISDN-OUT – ISDN telephone line output;
4 – RJ-11 connector – analog telephone line output;
5 – power socket;
6 – PWR LED – power supply;
7 – LNK LED – ISDN line;
8 – DTR LED – DTR line status of RS-232 port – module readiness to receive data from
a device connected to the RS-232 port (e.g. alarm control panel);
9 – CTS LED – CTS line status of RS-232 port – readiness of the device connected to the
RS-232 port (e.g. alarm control panel) to interact with the module;
10 – TX LED – sending data through the RS-232 port;
11 – RX LED – receiving data through the RS-232 port.
Description of terminals:
INP
– control input – alarm signal from the control panel
COM
– common ground
OUT
–
12V output for separator to cut off equipment from telephone lines – connect to
separator IN input
SEP
–
control output for separator to cut off equipment from telephone lines – connect
to separator SEP input
T-1, R-1 – analog telephone output (e.g. to connect the alarm control panel)
–
ground
GND
–
power supply common
+12V
–
+12V power supply
3. Connecting the module
3.1 Connecting the power supply
The equipment is supplied with +12V DC voltage. The power supply can be connected to the
onboard terminals (+12V and GND) or to the power socket. Never connect power supply
both to the terminals and to the socket at the same time. Correct power connection is
indicated by lighting of the PWR LED.
3.2 Connecting the alarm control panel
The telephone line connecting the control panel and the ISDN module may be connected to
the onboard terminals (T-1 and R-1) or to the RJ-11 telephone socket. Never connect the
analog telephone line both to the terminals and to the socket at the same time.
If the module is used as an external digital modem by the CA-64 or INTEGRA alarm control
panel, the two units should be additionally connected with the RS-232 cable. Length of the
RS-232 cable should not exceed 2.5 m. Never connect any equipment to both RS-232
sockets of the module at the same time. Configuration of the ISDN modem is carried out
4
SATEL
ISDN Module
by means of the AT commands. The ISDN modem automatically recognizes the RS-232
speed, the following speeds being supported: 4800Bps, 9600Bps, 19200Bps.
Fig. 2. Connection of the RS-232 ports of control panel and ISDN module.
The ISDN module is provided with a feature ensuring priority to the control panel outgoing
connections. To enable the control panel to make a connection, the other telephone lines
may be cut off.
The module factory settings with regard to cutting off the telephone lines ($C0) are based on
the assumption that the ISDN module works in the point-to-multipoint configuration ($M1)
(see section "Connecting the module to ISDN network"), and that the signal is connected to
the ISDN module from the control panel. It is recommended that the signal be connected
from the control panel OC output (signal polarization: active status 0V; the output
programmed as alarm one) to the INP and COM terminals of the ISDN module. With such
settings the ISDN module will cut off the ISDN line from the other devices only when the
control panel intends to make an alarm call, but it is impossible due to the line being occupied
by other subscriber devices. When the ISDN line is busy, and the outgoing connection
initiated by the control panel is not an alarm call, the ISDN module will not cut off the line to
the other subscriber devices, but will be waiting until the line is available.
If the alarm signal cannot be supplied to the ISDN module, it is recommended that you
change the line cut-off default settings to $C1, or leave the factory settings ($C0) and shortcircuit the INP and COM terminals. Both the $C1 setting and shorting the INP and COM
terminals with the $C0 setting will result in recognizing each connection initiated by the
control panel as the alarm call, and if the line is busy, all the other subscriber devices will be
cut off .
Telephone communication will be restored on all lines if no repeated demand to access the
telephone line is made within 10 seconds after the control panel hangs up. However, if the
panel fails to transfer all the programmed codes and messages, i.e. if at least one of the
connections has not been established because of the receiver line busy status, the telephone
communication will only be restored on all lines within 60 seconds after the control panel
hangs up.
In the point-to-point configuration ($M0) (see section "Connecting the module to ISDN
network"), the outgoing call initiated by the control panel will always require that the line be
ISDN Module
SATEL
5
cut off from the other subscriber devices, therefore it is recommended in this configuration
that you use the ($C1) setting, or short-circuit the INP, COM terminals with the $C0 setting.
3.3 Connecting the module to ISDN network
Correct connection of the module to the ISDN network, as well as selection of appropriate
settings, depend on the ISDN network configuration, the user is offered by the provider of
telecommunication services. There are two ISDN network configurations available on the
market, namely:
− point-to-multipoint configuration (usually offered to an individual customer),
− point-to-point configuration (often used by corporate customers, because of the possibility
to connect PABX equipment).
Prior to starting installation, you should determine the ISDN network configuration. The
SATEL ISDN module is programmed by default for operation in the point-to-multipoint
configuration. For the point-to-point configuration, it is necessary to program new module
settings by means of AT commands and save the settings.
3.3.1 Preparation for work in point-to-multipoint configuration
A characteristic feature of the point-to-multipoint configuration ($M1) is the possibility of
connecting many devices directly to the NT network termination module. When connecting
the ISDN module, you must take into account the maximum number of devices supported by
the NT network termination module (usually 8). The ISDN module is recognized as one of the
digital devices. The specific character of ISDN network in the discussed configuration allows
for simultaneously making up to two connections on the B-channels. This means that the
network can be simultaneously used by not more than 2 devices (e.g. 2 telephones or a
telephone and fax). However, it can happen that both B-channels are used by one device
(e.g. a modem connecting to the internet). In order to ensure tamper protection and correct
interaction between the ISDN network, ISDN module, control panel, and the other subscriber
devices, it is necessary to observe the essential principle of installation: the ISDN module
must be the first device connected to the S/T interface of the NT network termination module.
All the other subscriber devices (both analog and digital) must be connected by means of the
ISDN module and, if necessary, ISDN separator.
Use the RJ-45 socket marked as the ISDN-IN to connect the module to the digital telephone
network. Connect the equipment to the S/T interface of the network termination according to
the network termination manufacturer's directions. Length of the cable connecting the
ISDN module with the network termination should not exceed 2.5 m. Active state of the
S/T interface of the network termination is indicated by lighting of the LNK LED.
Probably the most frequently encountered case is connection by means of the ISDN module
to the ISDN network of the control panel and one digital subscriber device and/or one analog
subscriber device. Diagram of such an installation is shown in Fig. 3.
6
SATEL
ISDN Module
Fig. 3. Connecting one control panel and one digital subscriber device and one analog
subscriber device.
Where the ISDN module is used as an adapter which enables the control panel to be
connected to the ISDN network, the digital equipment should be connected to the ISDN
module socket marked as the ISDN-OUT. Such a connection protects the alarm system
against tampering.
Connecting a larger number of subscriber devices is more complicated. In such a case, an
ISDN separator must be used.
Fig. 4. View of the ISDN separator electronics board.
ISDN Module
SATEL
7
Legend to Fig. 4:
1 – RJ-45 connector, designated ISDN OUT – ISDN telephone line output;
2 – RJ-45 connector, designated ISDN IN – ISDN telephone line input;
3 – RJ-11 connector, designated ANALOG1 OUT – output, analog telephone line 1;
4 – RJ-11 connector, designated ANALOG1 IN – input, analog telephone line 1;
5 – SEP and IN terminals for connecting control signal from ISDN module;
6 – RJ-11 connector, designated ANALOG2 OUT – output, analog telephone line 2;
7 – RJ-11 connector, designated ANALOG2 IN – input, analog telephone line 2;
8 – relays.
The ISDN separator is to be connected to the ISDN module with two wires: connect the OUT
terminal of the ISDN module to the IN terminal of the separator, and connect together the
SEP terminals of both devices. The separator is fitted with a pair of RJ-45 ports for
connecting one additional digital subscriber device, and two pairs of RJ-11 ports for
connecting two additional analog subscriber devices. As the commercially available NT
modules have, usually, two connectors for digital devices (so-called S/T interface) and two
connectors for analog devices (so-called a/b interface), the design of ISDN module and the use
of SATEL ISDN separator ensure a tamper protection through exercising control of all the four
lines made available by the NT network termination module. An example of connecting
additional subscriber devices via the ISDN separator is shown in Fig. 5.
Fig. 5. Connection of the alarm control panel and two digital subscriber devices and two
analog subscriber devices.
8
SATEL
ISDN Module
3.3.2 Preparation for work in point-to-point configuration
The point-to-point configuration is mainly offered to corporate customers. It enables just one
device, usually a private exchange, to be connected to the NT network termination module. If
it is required to use the ISDN module in this configuration, you should change the ISDN
module settings, using AT commands, for operation in the point-to-point configuration ($M0).
In this case, the installation diagram will look as shown in Fig. 6.
It is assumed by default that another subscriber device, e.g. a private exchange is connected
to the ISDN module ISDN-OUT socket ($D1). For testing purposes or when the ISDN module
is the only digital device connected to the NT network termination module, you should
change the default settings related to presence of other devices to $D0.
Fig. 6. Connection of the alarm control panel and the digital private exchange.
4. Equipment Factory Settings
S0:000
E1
Q0
V1
W2
X4
&D2
$A1
$C0
–
–
–
–
–
–
–
–
–
automatic answer to incoming calls OFF
echo ON
display of result codes
display of result codes as words
CONNECT result code indicates speed of established connection
busy status check/answer tone detection ON
functionality of DTR line
automatic selection of TEI number in point-to-multipoint configuration
cutoff of the other telephone lines is realized when all lines are busy, module alarm
input is activated, and the control panel demands access to the telephone line
$D1
– in point-to-point configuration, another subscriber device is connected to the
module ISDN-OUT socket
$L0
– ISDN line monitoring OFF
$M1
– point-to-multipoint configuration
TEI:--- – no fixed TEI number
In most cases the factory settings will not need to be modified, as they ensure appropriate
functionality of the equipment.
ISDN Module
SATEL
9
5. Modification of ISDN Module Settings with AT Commands
The RS-232 port enables the ISDN module to be connected to the computer, thus making it
possible to modify the equipment settings by means of the AT commands (with Terminal type
program – as is the case in the traditional modem). Having entered the command, confirm it
by pressing the ENTER key.
The device settings are divided into 3 groups:
− ACTIVE SETTINGS – active settings, currently used by the ISDN module,
− USER PROFILE SETTINGS – user settings, defined by the user and stored in nonvolatile memory,
− FACTORY SETTINGS – factory settings.
By entering the AT&V command, you can see all the setting profiles.
Fig. 7. Window of the Hyper-Terminal program, showing the ISDN module settings.
After power-up, the user settings are loaded into the active profile. At the first start of the
ISDN module, the active, user, and factory settings are identical. The active settings can be
modified with the use of AT commands. For the modifications to be permanent, the new
settings must be saved in the non-volatile memory (user profile) by means of the AT&W
command. Loading the factory settings into the active profile is made possible by the AT&F
command. In order to load the user settings into the active profile, enter the ATZ or ATZ0
command.
6. AT Commands Accepted by ISDN Module
The ISDN module accepts the following AT commands:
A
B
D
– answer incoming call
– select ISDN protocol:
B14 - V.110 at a rate of 4800 baud
B15 - V.110 at a rate of 9600 baud
– select number (max. 20 characters)
Example
ATD497
En
- select no. 497
– echo configuration
E0 - switch echo off
E1 - switch echo on
10
H
In
Qn
Sn=
SATEL
ISDN Module
– hang up
– display equipment data
I0
– display product code (1292 means DSS1)
I1
– display equipment information (manufacturer, version)
– modification is not possible (default setting: Q0 - display result codes)
– write to S registers
S0 – number of rings after which the call is to be answered, min 0, max 255
Examples:
ATS0=5 – answer the incoming call automatically after 5 rings
ATS0=0 – disable the function of automatic answer to the incoming calls
Sn?
Vn
Wn
– read contents of S registers
– modification is not possible (default setting: V1 – display result codes as words)
– modification is not possible (default setting: W2 – CONNECT result code indicates
speed the connection is established with)
Xn
– modification is not possible (default setting: X4 – check of busy status and detection
of answer tone are activated)
Zx
– restore given profile settings
Z1 – restore factory settings
Z, Z0– restore user settings saved in non-volatile memory
&Dn – permanently set as &D2 and cannot be modified
&F
– restore factory settings
&V
– display settings for individual profiles
&W – save the active settings in non-volatile memory as a new user profile
&ZIn – save the MSN number (where n = 0 refers to analog connection, n = 1 connection in
V.110 standard)
Examples:
AT&ZI0=123 – entering this command makes the equipment receive ONLY the analog-type calls
directed at no. MSN ending in the sequence 123, the sequence length being min. 1 and
max. 20 digits
AT&ZI0= – entering this command (without any MSN number) makes the equipment receive all the
analog-type calls
&ZI? – display entered MSN numbers
$An – selection of the mode to assign the TEI number in ISDN network
$A0 – non-automatic assignment of the TEI number (by default in point-to-point
configuration)
$A1 – automatic selection of the TEI number (by default in point-to-multipoint
configuration)
$Cn – configuration of function to realize cutoff of telephone lines
$C0 – cutoff of the other telephone lines is realized when all lines are busy, module
alarm input is activated, and the control panel demands access to the
telephone line
$C1 – cutoff of the other telephone lines is realized always when all lines are busy
and the control panel demands access to the telephone line
$C2 – cutoff of the other lines is realized when alarm output is activated
$Dn – this option regards only the point-to-point configuration and defines whether the
ISDN module is to interact with an additional subscriber device connected to the
ISDN-OUT socket
$D0 – no devices connected to the ISDN-OUT output
$D1 – another subscriber device is connected to the ISDN-OUT output
ISDN Module
$L
$Mn
$T=
SATEL
11
– configuration of the ISDN line detecting function
$L0 – monitoring of ISDN line presence OFF
$L1 – monitoring of ISDN line presence ON, which constantly checks the activity in
physical layer
$L2 – monitoring of ISDN line presence ON – the activity in physical layer checked
every 30s
– selection of ISDN network configuration
$M0 – point-to-point configuration
$M1 – point-to-multipoint configuration
– enters the TEI number if $A0 option is selected, i.e. non-automatic assignment of the
TEI number
Example:
AT$T=0 – assignment of number TEI=0 to ISDN module
$T?
– displays the currently used TEI number
7. Technical data
Rated supply voltage .....................................................................................................12V DC
Maximum current consumption.......................................................................................500mA
Interfaces:
digital interface BRI (2B+D)
analog interface to connect analog subscriber equipment
Protocols:
DSS1 (Euro ISDN)
V.110
Working temperature range: ................................................................................. +5° to +35°C
Weight............................................................................................................................. 1.03kg
8. History of the manual updates
Described in the table below are changes as compared with the manual for the ISDN module
with firmware in version v1.00.
PROGRAM
DATE
INTRODUCED CHANGES
VERSION
2005-12
1.06
• Added information on work of the ISDN module in point-to-multipoint or point-topoint configuration (p. 2, 5 and 8).
• Re-edited section 3 "Connecting the module" (p. 3–8).
• Added drawing to illustrate connection of the RS-232 ports of control panel and
ISDN module (p. 4).
• Information on priority assignment to control panel outgoing connections has been
moved to section 3.2 "Connecting the alarm control panel" and modified by adding
the module operation in point-to-multipoint (p. 4) or point-to-point (p. 4)
configuration.
• Modified and supplemented information on ISDN separator (p. 6).
• Modified and supplemented section 4 "Equipment factory settings" (p. 8).
• Modified and supplemented section 5 "Modification of ISDN module settings with
AT commands " (p. 9).
• Modified and supplemented section 6 "AT commands accepted by ISDN module"
(p. 9–11).
SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gdańsk
POLAND
tel. + 48 58 320 94 00
[email protected]
www.satel.pl
Was this manual useful for you? yes no