H03608-00.B - 2012/01

Instructions for installation and use

English

EN

 

Read this manual carefully before installing, maintaining or repairing this device! 

The symbol 

indicates important information that must be taken into account in order to avoid  risk of personal injury and/or damage to the appliance. 

 

The symbol 

indicates useful information. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H03608‐00.B1.EN – 2012/01

 

   Warnings 

 

Our  products  may  be  subject  to  change  without  notice  as  part  of  our  continuous  improvement 

policy.  

Exclusive use: pool water heating (must not be used for any other purpose). 

The device must be installed by a qualified technician according to the manufacturer’s instructions 

and  in  compliance  with  local  regulations.  The  installer  is  responsible  for  the  correct  installation  of  the  device  and  for  ensuring  compliance  with  local  regulations.  The  manufacturer  shall  not  be  held  liable  for  any  potential  issues  that  may  occur  as  a  result  of  failure  to  comply  with  local  standards  pertaining to installation. 

This appliance must be handled by competent and qualified personnel (physically and mentally) who 

are familiar with the operating instructions (by reading the user guide). Persons who do not satisfy  these  requirements  must  not  handle  the  device  so  as  to  avoid  exposure  to  potentially  dangerous  parts. 

If the device malfunctions: do not attempt to repair the device yourself, call your installer. 

Before carrying out any operation on the machine, check that the power supply is cut and that the 

machine is tagged out,  

Prior to any operation, check that: 

-

The voltage on the identification plate of the appliance corresponds to the main voltage available  on site,  

-

the socket and the power supplied are adapted to the power requirements of the appliance, and  that they are grounded,  

-

the electrical plug is adapted to the socket available. 

If any safety device is removed or shunted, the warranty will automatically be void. This will also 

apply if parts are replaced with parts acquired elsewhere than our stores. 

Incorrect installation may cause serious damage and/or personal injuries (possibly death). 

Keep the device out of the reach of children. 

 

 

 

Summary 

 

1. Information before installation ....................................................................................................... 2

 

1.1 General terms of delivery, storage and transport ........................................................................................................ 2

 

1.2 Content ......................................................................................................................................................................... 2

 

1.3 Operating conditions .................................................................................................................................................... 2

 

1.4 Technical specifications ................................................................................................................................................ 3

 

2. Installation ...................................................................................................................................... 3

 

2.1 Selecting an installation site ......................................................................................................................................... 3

 

2.2 Hydraulic connections ................................................................................................................................................... 3

 

2.3 Electrical connections (for Heat Line + and SC only) ..................................................................................................... 4

 

3. Use ................................................................................................................................................. 5

 

3.1 Presentation of the regulation ...................................................................................................................................... 5

 

3.2 Starting the device ........................................................................................................................................................ 5

 

3.3 Checks to be carried out after operating for a few moments ...................................................................................... 6

 

3.4 Winter storage .............................................................................................................................................................. 6

 

4. Maintenance ................................................................................................................................... 6

 

4.1 Maintenance instructions ............................................................................................................................................. 6

 

4.2 Recycling ....................................................................................................................................................................... 6

 

5. Resolution of problem .................................................................................................................... 6

 

5.1 Malfunctions of the device ........................................................................................................................................... 6

 

5.2 Fuse replacement ......................................................................................................................................................... 7

 

5.3 Modification of the maximum setpoint temperature .................................................................................................. 7

 

5.4 Reversing the pool water circulation direction in the exchanger (Heat Line + and SC only) ........................................ 7

 

5.5 FAQ ............................................................................................................................................................................... 7

 

6. Product registration ........................................................................................................................ 8

 

 

7. Conformity certificate ..................................................................................................................... 8

 

 

Available in appendix at the end of the manual:  

- wiring diagrams 

- dimensions and description 

 

1. Information before installation 

 

1.1 General terms of delivery, storage and transport 

Any  equipment,  even  carriage  and  packing  free,  travels  at  the  consignee's  risk.  The  consignee  shall  make  reservations in writing on the carrier's bill of lading if damage is detected, caused during transport (confirmation 

 

to be sent to the carrier within 48 hours by registered mail with acknowledgement of receipt). 

 

1.2 Content 

or 

 

Heat Line + 

(+) 

Heat Line without circulating   pump 

(SC) 

 

 

1.3 Operating conditions  

 

 

 

 

 

Operating range: 

 pool water temperature between 2 °C and 40 °C, 

 primary circuit water temperature between 45 °C and 90 °C, 

 primary circuit service pressure: 2 bar, 

 primary circuit maximum pressure: 3 bar. 

H03608‐00.B1.EN – 2012/01

    or

 

Bare Heat Line 

(N) 

 

 

1.4 Technical specifications 

 

Heat Line  

Primary 

Secondary 

Power 

Unit 

°C 

°C  kW 

90 

20 

26 

Flow rate  

Primary 

Secondary 

m³/h 

20 

0.9 

10 

Primary 

Head loss 

Secondary 

 

 

 Heat Line + protection rating: IP 44  mCE 

 

1.4.1 Heat Line + circulating pump characteristics 

0.15 

0.5 

Heat Line + 

20‐40‐70  circulating  pump 

UPS 25/40 

centre‐to‐centre  distance 

130 mm 

 

2. Installation 

 

2.1 Selecting an installation site 

45 

0.7 

90 

40 

1.7 

40 

26 

15 

0.2 

0.8 

input power  speed 3 

45 W 

45 

1.4 

In 

0.2 A 

90 

70 

70 

26 

20 

0.3 

45 

14 

2.4 

capacitor 

1.5 µF V 

The appliance must be installed in a technical room ventilated, dry and without stored pool treatment 

 

products. 

 

 An  unobstructed  space  of  at  least  80  cm  around  the  appliance  is  required  to  facilitate  its  installation  and  maintenance.  

 Correctly tighten the hydraulic connections and check for leaks, 

 The appliance must be secured horizontally to the wall of the technical compartment,  

- Heat Line + and SC: using the holes at the back of the electric box and 4 screws (not included), 

 

- Heat Line N: using brackets (not included), 

Install  the  appliance  as  close  as  possible  to  the  heating  source  (boiler,  heat  pump,  geothermal  unit,  solar 

heating unit, etc.).   

 If the appliance cannot be installed next to the heating source:  

‐ Provide piping of appropriate size for the primary and secondary circuits in relation to the water flow rate,  head losses and distance, and ensure that they are properly insulated. 

‐ Install a more powerful circulating pump (contact us regarding its size and supply), 

 If the exchanger is located far from the filter: The pipes of the pool system must be Ø50, or Ø63 if the system  has an overall length in excess of 30 meters, and must be routed through a protective conduit if buried.  

 Preferably, the exchanger should be installed at the low point so that it is always full of water.  

 The water treatment system must be installed after the exchanger and at a low point to prevent chlorine from  returning back into the exchanger.  

 

 Check that the piping system is clean before making connections.  

 The exchanger must not support the piping.  

 

2.2 Hydraulic connections 

 

Observe the hydraulic connection direction (refer to the indications on the tank of the heat exchanger)  to optimise the exchange of calories (to reverse the flow direction on Heat Line + and SC, see §5.4) 

The water coming from the heating source must be at constant temperature. 

H03608‐00.B1.EN – 2012/01

   

heating system connection (a.k.a. primary) :  

‐ use insulated pipes;  

 

‐ equipped with a safety valve (pressure set at 3 bar) and correctly dimensioned expansion chamber;  

‐ the pipes must be equipped with automatic air bleeders at high points, 

 

 

  Branch connections on the primary circuit must be placed upstream from all valves or pumps. 

Heat Line N: if the heating source is equipped with a circulating pump, an accumulator or relay logic must 

  be provided  to stop the circulating pump and the heating source. 

 

connection of the pool system (a.k.a secondary) :  

‐ use Ø50 PVC pipes minimum,  

‐ via  a  by‐pass  (recommended  to  simplify  maintenance  and  mandatory  if  the  water  flow  rate  of  the  pool  system is greater than 22 m³/h).  

 

90° elbow fittings must not be installed directly at the exchanger outlet; leave at least 25 cm of straight  pipe to prevent chatter of the flow controller armature. 

Heat Line20‐40‐70  Primary connection    Secondary connection 

Heat Line + and SC  Ø 26/34 female, screw type 

PVC Ø50 or Ø63 

Heat Line N  Ø 26/34 male, screw type 

 

 

 

 

 

 

 

 

A

: Heat Line body 

 water treatment 

 pool system 

 

 

 

 

 

 

 heating system 

V1‐V2‐V3: shut‐off valves 

V4: hot water inlet valve 

 

 

 

 

 

 

 

V5: hot water outlet valve 

  automatic bleeder 

 Solenoid valve (optional) 

 circulating pump * 

* supplied with Heat Line + 

 

2.3 Electrical connections (for Heat Line + and SC only) 

 

Loose terminals may cause the supply terminal board to overheat, and will void the warranty. 

The device must be connected to an earth electrode. 

Risk of electric shock inside the appliance.  

The appliance must only be connected by a qualified and experienced technician. 

If the power cable is damaged or its length is too short, it must be replaced by a qualified technician.

  

All use of an extension cord or multisocket connection is prohibited. 

Check the following before all operations: 

-

the voltage indicated on the unit corresponds to the mains voltage;  

-

the power outlet and the power supply network are appropriate for exchanger use and that they are  equipped with an earth connection;  

-

the power plug is adapted to the power outlet. 

 

Electrical protection:  

‐ either by a 5 A fuse disconnector with, upline, a 30 mA differential circuit breaker (rating > 5 A),  

‐ or by an independent 30 mA circuit breaker (rating: 5 A) upline, 

 The single‐phase electrical supply (230 V‐50 Hz) of the exchanger must be provided through a protection and  switching  device  (not  supplied)  complying  with  current  standards  and  regulations  in  the  country  where  it  is 

  installed. 

 The electrical conduits must be secured. 

 The electrical supply cable must not be exposed to elements that are sharp, hot or represent a crush hazard. 

 Connect the power cable, supplied with the unit, to a power outlet in compliance with the country's current  standards and regulations, 

2.3.1 Connection of an external control to power the primary circuit (for Heat Line+ and SC only) 

 

 Use a 3G1 cable (cross‐section 1 mm²).  

 This function is carried out via the non‐polar dry contact “normally open at rest” (Imax 5 A at 250 VAC 50‐60 Hz)  available on the regulator terminals 19‐20. 

 

H03608‐00.B1.EN – 2012/01

   

 The wire connected to terminals 19‐20 must go through the additional discharge “grommet” (supplied) to be  installed on the base of the box. 

 

 

Ph: phase 

 

N: neutral 

 

F: fuse (5 A maximum)  

 

C: complementary circulating pump  

V’: 3‐way valve with mechanical 

  return 

 

CH: existing heating source 

V’’: motorized 3‐way valve with two 

  rotation directions  

KA1: control relay 

The  elements:  C ‐  CH ‐  F ‐  KA1 ‐  V’ ‐ 

V’’ are not supplied with this device. 

 

 

3. Use 

3.1 Presentation of the regulation 

Digital display 

Temperature  control buttons 

Heater indicator light (steady =  heating in progress, flashing =  on stand‐by) 

“On/Off“ indicator light 

“On/Off” button 

 

 

 

3.2 Starting the device 

Never circulate water in the primary circuit without water circulating in the secondary circuit. 

The flow rate must be adjusted slowly to avoid hammering. 

 

If  the  primary  circuit  circulating  pump  has  not  been  in  operation  for  a  long  time,  check  that  it  has  not 

  seized:  with  the  circulating  pump  off,  unscrew  the  pump's  front  panel  (water  may  flow  out),  then  use  a  screwdriver to turn the motor shaft. 

 

 Fully open valves 2 and 3 and close valve 1 (see §2.2), if installed. 

 Start the filtration pump.  

 Check the pool water circulation in the exchanger. 

 Fully open valves 4 and 5 (see §2.2), 

 Check the filling and degassing of the heating circuit.  

 Turn on control unit power, then start it. 

 Adjust the setpoint temperature: display and modify the setpoint value by pressing either 

 or 

 

 

On Heat Line + and SC:  

 Pressing and holding either of these two buttons allows rapid change of the setpoint value.  

 The temperature is controlled degree by degree. 

 The setpoint value adjustment range is between 2 °C and 40 °C.  

 This maximum temperature may be lowered to protect the swimming pool liner (see §5.3). 

 If the setpoint temperature is greater than the pool water temperature: the “reg” indicator light flashes  for 15 seconds, then remains steady, the circulating pump should operate. 

 If the water flow rate is too low (less than 1.1 m³/h), or if the filtration is stopped, the “reg” indicator  light will flash and the water in the primary circuit will stop circulating.  

 When the pool has reached the desired temperature, the “reg” indicator light goes out, and water in the  primary circuit will stop circulating. 

On Heat Line N: The control module (not included) must: 

 reference the input temperature of the pool water in the unit; 

H03608‐00.B1.EN – 2012/01

   

 

 give the command to irrigate the primary circuit only if heating is requested and filtration is operational; 

 stop irrigating the primary circuit once the pool has reached the desired temperature. 

 

3.3 Checks to be carried out after operating for a few moments 

 

 Check for leaks. 

 Check that the circulating pump stops when:  

- the setpoint temperature is decreased or when the control is shut off;  

 

- filtration is switched off,  

 Check that the exchanger is no longer irrigated by the heating circuit when the filtration is stopped, and when  there is no request to heat the pool water. 

 

3.4 Winter storage 

Winter storage is essential due to the risk of body of the exchanger freezing and breaking. This situation 

 

is not covered by the warranty. 

 

 Turn off control unit power.  

 Shut off water circulation in the primary and secondary circuits.  

 Drain  the  primary  circuit  (be  careful  of  the  water  temperature,  wait  for  it  to  cool  down  to  avoid  the  risk  of  burns):  

- close shut‐off valves 4 and 5 (see §2.2),  

- unscrew the drain plug, 

 

Warning:  only  the  plug's  seal  ensures  water  tightness.  Replace  it  without  using  hemp!  To  ensure  a 

 

watertight seal and avoid damaging the threads, do not overtighten the plug + seal assembly. 

 

 Drain the secondary circuit:  

- close valves 2 and 3 (see §2.2),  

- unscrew the fittings to drain the exchanger; 

- when the exchanger is empty, lightly retighten the fittings, without creating a seal. 

 

 

4. Maintenance 

 

4.1 Maintenance instructions

 

It  is  recommended  that  the  device  be  general  serviced  on  a  yearly  basis  to  ensure  proper  operation, 

 

  maintain performance levels and prevent some potential failures. 

This is the responsibility of the user and must be performed by a qualified technician. 

 

 Never disassemble the exchanger body.  

 

 Make sure that the appliance's pipe fittings are property tightened. 

 

Only for Heat Line + and SC:  

 Check the electrical components. 

 Check the ground connection. 

 Check that the electric cable connections are properly tightened and that the electric box is clean. 

 

4.2 Recycling 

This symbol means that your device must not be thrown in the bin. The device must be collected by a  selective  system  in  view  of  re‐use,  recycling  or  similar.  Any  substances  it  may  contain  which  are  potentially dangerous to the environment shall be eliminated or neutralised. 

Request information on recycling procedures from your retailer. 

 

5. Resolution of problem 

 

5.1 Malfunctions of the device 

Dysfunction  Causes 

The display does not  work 

The appliance displays  a flashing “E0” 

Power is not supplied to the  appliance 

The control sensor is out of  service or disconnected 

solution 

The regulator fuse is blown (for replacement, see 

§5.2) 

Appliance power off and locked out, reconnect or  standard replacement of the sensor (the “E0” fault is  automatically cleared) 

H03608‐00.B1.EN – 2012/01

   

 

Dysfunction  Causes  solution 

The pool water  is hotter than  requested 

The regulator is not operating  correctly  check that the circulating pump stops when the setpoint  temperature is reached

 

Another circulating pump is  pushing on the primary circuit 

 

5.2 Fuse replacement 

 

IMPORTANT! Disconnect power to the appliance! 

 Remove the cover.  

 Disconnect the regulator.  

 

 Remove the regulator cover.  

 Remove the fuse (T3, 15AH250V). 

If this is the case, install a solenoid valve on the outgoing leg  of the primary heating circuit controlled by terminals 19‐20 

(see §2.3.1) 

5.3 Modification of the maximum setpoint temperature 

 Turn off the regulator (the “on” indicator light goes off, the pool water temperature is displayed). 

 Simultaneously press and hold 

 and   for 5 seconds, “PA” is displayed. 

 Press  . 

 Then enter the value “80” using the 

 or   keys (access code to the settings menu). 

 Press   to confirm this code, “PA” is displayed. 

 Simultaneously press and hold the 

 and   keys for 5 seconds. 

 Press 

 to scroll through each parameter until “r2” is displayed. 

 Press  , the current value of the parameter “r2” is displayed.  

 Press 

 or   to modify the maximum setpoint value.  

 

 Press   to confirm this new value. 

 Simultaneously press and hold 

 and   for 5 seconds to return to the pool water temperature display. 

5.4 Reversing the pool water circulation direction in the exchanger (Heat Line + and SC only) 

 Remove the electric box cover.  

 Disconnect the regulator's two connectors to remove the cover.  

 Unscrew the 4 retaining screws from the electric box's support.  

 Pivot the circulating pump 180°.  

 Position, then secure the electric box support using the 4 retaining screws.  

 Reconnect the two connectors to the regulator.  

 Reposition the electric box cover and secure it with the screw. 

 

 

5.5 FAQ 

Where should my water  treatment system be  positioned with respect 

to the heating system? 

Is it possible to improve  temperature 

performance? 

H03608‐00.B1.EN – 2012/01

 

The  water  treatment  system  (chlorinator,  salt  chlorinator,  etc.)  must  be  installed  preferably  downstream  from  the  appliance  (see  installation  §2.2),  and  must  be  compatible with the latter (check with the manufacturer)  protect the pool with a cover (floating cover, roller cover, etc.), to avoid heat loss 

Check that  filtration  time is  sufficient   during the heating phase, water flow must be continuous (24/24)  to  maintain  the  temperature  throughout  the  season,  allow  for 

“automatic” flow of at least 12 hours/day (the longer automatic flow  is used, the more time the appliance will have to function and to heat  the water) 

 

6. Product registration 

 

Register your product using our website:  

- you will be among the first to be informed of new Zodiac products and special offers, 

- You can help us to constantly improve our product quality. 

 

Australia – New Zealand 

www.zodiac.com.au 

South Africa 

Europe and rest of the world 

www.zodiac.co.za  www.zodiac‐poolcare.com 

 

7. Conformity certificate 

 

Z.P.C.E. declares that the following products or ranges: 

Special swimming pool heat exchanger: Heat Line + and SC 20‐40‐70 

  are in compliance with the provisions of: 

the ELECTROMAGNETIC COMPATIBILITY directive 89/336/EEC 

the LOW VOLTAGE directive 73/23/EEC 

 

H03608‐00.B1.EN – 2012/01

   

 

Wiring diagram  

 

Heat Line + / Heat Line SC 

 

CA 

TH 

M1 

F1 

CD 

So 

GN 

L1 

L2 

S1 

19‐20 

V‐j 

Bl 

 

  power supply cord: 2P+G 10/16A 3G1  control thermostat with digital display  circulating pump motor  fuse 3.15 A‐G  flow controller  pool water control sensor (PTC)  black conduit  

“on/off” LED  flashing “reg” LED: timer active; steady: heating in progress 

“on/off” switch 

“normally open” control dry contact  green‐yellow  blue  brown  white  black 

Ground 

 

 

 

Dimensions  

 

H03608‐00.B1.EN – 2012/01

   

 

 

 

 

20 

40 

70 

 

 

 

 

 

Description  

Heat Line 

Heat Line + 

6,5 Kg 

7 Kg 

7,5 Kg 

 

20‐40 

535 

198  weight  

Heat Line SC 

4,2 Kg  

 4,7 Kg 

5,2 Kg 

70 

665 

328 

Heat Line N 

3,1 Kg 

3,2 Kg 

4 Kg 

 

 

1* 

6* 

8* 

9** 

10** 

11** 

12** 

13*** 

** 

*** 

Nipple, male/male Ø26/34 

PVC ½ union fitting Ø63, to be glued 

Multitube exchanger body  primary circuit drain plug  check valve 

Exchanger body fastener  thermowell  plug 

Spacer 

Flow controller 

Control sensor 

Electric box  circulating pump 

For Heat Line N only 

On Heat Line + and SC only 

On Heat Line + only 

H03608‐00.B1.EN – 2012/01

   

 

Plaque signalétique – Product name plate

Pour plus de renseignements, merci de contacter votre revendeur.

For further information, please contact your retailer.

ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.

Votre revendeur / your retailer

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement