FEATURES MODEL N1100 - 1 1/4” NPT PORTS

FEATURES MODEL N1100 - 1 1/4” NPT PORTS
MODEL
N1100 SERIES
BRONZE CLOSE COUPLED
ROTARY GEAR PUMPS
MODEL N1100 - 1 1/4” NPT PORTS
FEATURES
• Bronze Construction with Stainless Steel Shafts
• Positive Spring Loaded Lip Seal made from Viton(R)*
• Available with Motor Adapter and Hardware
• Easy Field Assembly to Motors
• Self-Lubricating Carbon Bearings
• Consult Factory for Special Motors
DRIVE
The pump is driven directly from the electric motor shaft
by means of a flexible coupling. An aluminum adapter connects the pump to the motor.
LIQUIDS AND TEMPERATURE
Refer to Model No. N11HDL for pedestal model
and performance at different speeds.
Pump No.
N1100
N1100W
N1100X
N1100Y
N1100Z
Description
Pump Only
Pump, bracket and hardware for mounting
to 56C frame motors
Pump, bracket, and hardware for mounting
to the following motor frames: 143TC,
145TC, 182C, 184C
Pump, bracket, and hardware for mounting
to the following motor frames: 182TC,
184TC, 213C, 215C
Pump, bracket, and hardware for mounting
to the following motor frames: 213TC,
215TC
Water 70 F
HP
HP
Motor
Pump & Motor No.
REQ. Motor Frame
Single Ph.
Three Ph.
0
40
0.8
1
145TC
N1100XN46
N1100XN96
10
39
0.9
20
38
1.1
1 1/2 145TC
N1100XT46
N1100XT96
30
37
1.4
40
36
1.7
2
184TC N1100YW 46
N1100YW 96
50
35
2
60
34
2.3
70
33
2.6
3
213TC
N1100ZY46
N1100ZY96
80
32
2.8
90
31
3.2
100
30
3.5
5
213TC
--N1100ZX96
125
28
4.3
150
25
5
Note: Motors listed have O.D.P. enclosures and the following
electrical requirements:
Single Phase: 115/230V, 60HZ
Three Phase: 230/460V, 60HZ
1140 RPM
PSI GPM
www.oberdorfer-pumps.com
Service life will be increased substantially if liquid
pumped is clean and has lubricity value. These pumps have
extremely close tolerance. Fine abrasives like sand, silt, or
powders in suspension will destroy pumping ability.
Liquids compatible with bronze, stainless steel, and a
Viton(R)* lip seal can be pumped. Check a chemical compatibility chart or Oberdorfer factory. Buna Lip Seal (S3) available.
Temperature extremes are detrimental to service life
and should be avoided. Temperature range for this pump is
from -40oF to 300o F. Freezing liquid in the pump can deform
or damage the pump.
SUCTION LIFT
A rotary gear pump is capable of lifting water on the suction side as high as 20 feet. Though gear pumps are selfpriming, a foot valve is recommended. If possible, wet gears
with the liquid to be pumped for the first dry start. Liquid
retained in the system and gear chambers serves to wet the
pump on subsequent starts.
ROTATION
The pump or pump/motor unit is supplied by the factory
for shaft rotation in either direction. Reversing the motor rotation will reverse the “in” and “out” ports.
To reverse single phase motors, find instructions on the
inside of junction box cover or on name plate of motor.
Three phase motors are not wired for any particular
rotation. They can be reversed by interchanging any 2 wires
of the 3 wire leads.
*Viton(R) or equivalent FKM will be used. Viton(R) is a registered
trademark of DuPont Dow Elastomers.
PHONE (800) 448-1668; (315) 437-0361
FAX (315) 463-9561
MODEL
N1100 SERIES
BRONZE CLOSE COUPLED
ROTARY GEAR PUMPS
EXPLODED VIEW
3
4
5
6
7
9
8
10
2
Cover Bearing
Idle
Drive
Idle
Drive
Dowel
O-Ring
Body
Screws
Shaft
Shaft
Gear
Gear
Pins
1 Req'd
8 Req'd 4 Req'd 1 Req'd 1 Req'd 1 Req'd 1 Req'd 2 Req'd 1 Req'd
1 Req'd
N1100 9333NN5N
5393
5108
7652
8720
9834
9833
8597
9797-158 9330NG3N
N1100S3 9333NN5N
5393
5108
7652
8720
9834
9833
8597
9797-158 9330NG3N-1
Pump No.
1
1
Cover
11
Ret.
Ring
4 Req'd
7651
7651
12
13
14
15
Lip
Ret.
Key
Adapter
Seal
Ring
Kit
1 Req'd 1 Req'd 2 Req'd
7262
7345
6518
See
Below
6500
7345
6518
Repair Kit #11581 contains items 3, 4, 5, 6, 7, 9, 11, 12, 13 & 14
Basic pump model number N1100 must be matched to appropriate motor adapter kit listed as W, X, Y, Z kits as required by motor frame size.
The final model number is formed by adding codes together in a building block fashion.
Example: 1) Find pressure/flow, required HP, suggested motor frame size (see front) single or (3) phase.
ex: 35 [email protected] 50 PSI requires 2HP, 184TC frame motor
2) Pump/Adapter/Motor Model No:
Motor Mounting Adapter Kits (item 15)
EXAMPLE:
N1100
Basic
Pump
Y
W96
Mounting
2HP
Adapter Kit 3 Phase
(fits 184TC
Motor
Motor Frame Code
Kit
code.
Kit
Will Fit NEMA
No.
Motor Frames
Motor Flange Motor Shaft
Dia. Ref.
Dia. Ref.
"A"
"B"
W
X
Y
11617
11608
11609
56C
143TC, 145TC, 182C, 184C
182TC, 184TC, 213C, 215C
4.5"
4.5"
8.5"
5/8"
7/8"
1 1/8"
7.56"
7.56"
8.38
10.68"
10.68"
11.50
Z
11610
213TC, 215TC
8.5"
1 3/8"
8.38
11.50
MOTOR DATA
Horse Motor SinglePhaseThreePhase NEMA
Power Code PartNo. PartNo. FrameSize
1 N46 8478
--145TC
N96 --8480 145TC
11/2 T46 8549
--145TC
T96 --8486 145TC
2 W46 8548
--184TC
W96 --8490 184TC
3 Y46 5846
--213TC
Y96 --8547 213TC
5
X96 --8687 213TC
Specifications are subject to change without notice.
3/06
www.oberdorfer-pumps.com
PHONE (800) 448-1668; (315) 437-0361
FAX (315) 463-9561