- No category
advertisement
SectionD 2004.qxd 6/26/04 11:24 AM Page D-3
EN 523 & CP 523
Sealed High Pressure Regenerative Blower w/Explosion-Proof Motor
FEATURES
• Manufactured in the USA – ISO 9001 compliant
• Maximum flow: 84 SCFM
• Maximum pressure: 158 IWG
• Maximum vacuum: 135 IWG
• Standard motor: 3.0 HP, explosion-proof
• Cast aluminum blower housing, cover, impeller & manifold; cast iron flanges (threaded); teflon lip seal
• UL & CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres
Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards
MOTOR OPTIONS
• International voltage & frequency (Hz)
• Chemical duty, high efficiency, inverter duty or industry-specific designs
• Various horsepowers for application-specific needs
BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models
• Slip-on or face flanges for application-specific needs
ACCESSORIES
(See Catalog Accessory Section)
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges & relief valves
• Switches – air flow, pressure, vacuum or temperature
• External mufflers for additional silencing
• Air knives (used on blow-off applications)
• Variable frequency drive package
7.0
6.0
5.0
4.0
3.0
2.0
1.0
200
180
160
140
120
100
80
60
40
20
0.5
BLOWER PERFORMANCE AT STANDARD CONDITIONS
AIR FLOW RATE (M 3 /MIN) AIR FLOW RATE (M 3 /MIN)
1.0
1.5
2.0
2.5
0.5
1.0
1.5
2.0
5000 -200
A, B
▲
PRESSURE
▲ -MAX PRESSURE
POINTS
A-3 HP (3 Phase)
B-3 HP (1 Phase)
4500
4000
3500
14
12
10
-180
-160
-140
2.5
SUCTION
▲ -MAX SUCTION
POINTS
A-3 HP (3 Phase)
B-3 HP (1 Phase)
3000 -120
8
2500 -100
60 Hz
6
60 Hz
2000 -80
1500 -60
4
50 Hz 50 Hz
1000
500
2
-40
-20
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
0 20 40 60
AIR FLOW RATE (SCFM)
80 100 0 20 40 60
AIR FLOW RATE (SCFM)
80 100
Rev. 2/04
D-3
4000
3000
2000
1000
100
70
40
10
100
70
40
10
4000
3000
2000
1000
100
70
40
10
100
70
40
10
AMETEK Technical and Industrial Products, Kent, OH 44240 • e mail: [email protected] • internet: www.ametektmd.com
SectionD 2004.qxd 6/26/04 11:24 AM Page D-4
EN 523 & CP 523
Sealed High Pressure Regenerative Blower w/Explosion-Proof Motor
Scale CAD drawing available upon request.
A 0.75" NPT CONDUIT CONNECTION AT 12 O’CLOCK POSITION
DIMENSIONS:
IN
MM
TOLERANCES: .XX ±
.1
2.5
(UNLESS OTHERWISE NOTED)
MODEL
EN/CP523M72L
EN/CP523M5L
L (IN) ± .3
19.3
21.66
L (MM) ± 8
491
550
D (IN) ± .1
7.2
8.5
D(MM) ±3
183
216
B ± .19
15.76
15.76
B ± 5MM
400
400
SPECIFICATIONS
MODEL EN523M5L EN523M72L
Part No.
038223 038184
Motor Enclosure – Shaft Material Explosion-proof – CS Explosion-proof – CS
Horsepower
Phase – Frequency 1
3.0
Single - 60 Hz
3.0
Three - 60 Hz
Voltage 1
Motor Nameplate Amps
Max. Blower Amps 3
Inrush Amps
Starter Size
Service Factor
Thermal Protection
Shipping Weight
2
XP Motor Class – Group
208-230
15.5-14.5
18.1-16.7
94-88
1
1.0
Class B - Pilot Duty
I-D
222 lb (100 kg)
230
7.4
7.6
62
0
460
3.7
3.8
31
0
1.0
Class B - Pilot Duty
I-D
198 lb (90 kg)
CP523FU5LR
–
Chem XP – SS
Same as
EN523M5L –
038223 except add
Chemical Processing
(CP) features from catalog inside front cover
CP523FU72LR
038968
Chem XP – SS
Same as
EN523M72L –
038184 except add
Chemical Processing
(CP) features from catalog inside front cover
1
2
3
Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and certified to operate on both: 208-230 /415-460 VAC- 3 ph- 60 Hz and 190-208/380-415 VAC- 3 ph- 50 Hz. Our dual voltage 1 phase motors are factory tested and certified to operate on both: 104-115 / 208-230 VAC-1 ph- 60 Hz and 100-110 /200-220
VAC-1 ph- 50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside our certified range.
Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.
Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient temperature reaches the maximum operating temperature.
Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates.
AMETEK Technical and Industrial Products, Kent, OH 44240 • e mail: [email protected] • internet: www.ametektmd.com
Rev. 2/04
D-4
advertisement