- Home
- Home security & automation
- Gate Opener
- CENTURION SYSTEMS
- G-SWITCH-22 2G GSM Module
- Installation Guide
- 8 Pages
Centurion Systems G-SWITCH-22 2G GSM Module GSM Module Installation Guide
Below you will find brief information for GSM Module G-SWITCH-22 2G GSM Module. The G-SWITCH-22 2G GSM Module allows up to 1200 users to activate outputs on the module using their mobile phones. Outputs can be used to open a gate, activate an alarm system, turn on a borehole pump, etc. Users can also be notified by SMS of the activation of either of the two Inputs, in the event of an alarm activation, a power failure, etc. The secure, online G-WEB portal provides another means of programming and administering your G-SWITCH-22 and gives you access to several advanced features. The Module is over-the-air bootloadable via the G-WEB interface, meaning that it is not necessary to waste precious time and fuel to go to site, and updates to the firmware etc, can be done from the comfort of your home or office.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
G-SWITCH-22 2G GSM Module
Installation Guide
TM
Centurion Systems (Pty) Ltd www.CentSys.com
1. Introduction
The G-SWITCH-22 GSM Module allows up to 1200 individual users to activate a maximum of two outputs on the Module using their mobile phones.
These outputs can be used to open a gate, activate an alarm system,
Missed Call (free), Please Call Me message (free), or a pre-specified text message (SMS).
In addition, users can also be notified by SMS, of the activation of either of the two Inputs on the Module, in the event of an alarm activation, a power failure, etc. The Input Module of the G-SWITCH-22 can be configured to react to rising, falling or both edges, and different messages can be set for rising and falling edges. It also boasts adjustable
Filter and Blanking Times and an event counter, all of which are discussed in detail in the ‘Special functionality’ section of the separate Programming
Guide. The secure, online G-WEB portal provides another means of programming and administering your G-SWITCH-22 and gives you access to several advanced features.
The Module is over-the-air bootloadable via the G-WEB interface, meaning that it is not necessary to waste precious time and fuel to go to site, and updates to the firmware etc, can be done from the comfort of your home or office.
1. May require additional external switchgear
2. Important Safety Instructions
1. All installation, repair, and service work to this product must be done by a suitably qualified person.
2. Do not in any way modify the components of the system.
3. Do not install this product near sensitive electrical components.
(e.g. the DOSS sensor inside a gate motor housing)
4. Do not install the equipment in an explosive atmosphere: the presence of flammable gas or fumes is a serious danger to safety.
5. Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such materials are potential sources of danger.
6. Dispose of all waste products like packing materials, according to local regulations.
7. Centurion Systems does not accept any liability caused by improper use of the product, or for use other than that for which the automated system was intended.
8. This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the service life/operation of the product and/or be a source of danger.
9. Anything not expressly specified in these instructions is not permitted
This icon indicates tips and other information that could be useful during the installation.
This icon denotes variations and other aspects that should be considered during installation.
3. Security Consideration
It is strongly advised that a pre-paid SIM card (with limited airtime) is used, and that it is also PIN-code protected. These measures will give you peaceof-mind as they will ensure that your SIM card will have little or no value should it ever get stolen. Record the IMEI of your G-SWITCH-22 in the blocks provided in Section 6. In the event that the G-SWITCH-22 is stolen, you can use the IMEI number to blacklist the G-SWITCH-22.
4. General Description
The G-SWITCH-22 GSM Module uses the GSM mobile phone network to enable remote control and communication between itself and up to 1200 authorised users via their mobile phones.
A valid, activated SIM card is required in order to use the Module on the
GSM network.
When programming the G-SWITCH-22 , each user’s phone number can be set to:
& Activate a specified output with a Missed Call (free)
& Activate either output via a unique, user-defined SMS or one of twenty pre-programmed default SMSs (more convenient)
& Be notified by a unique, user-defined SMS of either of the two Inputs being activated
& Activate Output 1 via a free Please Call Me message
& Programming of the Module is password-protected
& All users calling or sending an SMS to the Module need to ensure that their Caller Line Identification Presentation (CLIP) is activated on their phone to ensure that the Module recognises the user’s learned-in phone number
& Contract SIM cards used in the G-SWITCH Module also need to have CLIP enabled
& The Module requires a power supply of 11V-30V DC, capable of delivering 500mA peak current
& Both outputs are potential-free, and rated to 30V DC @ 1A
& Both normally-open and normally-closed contacts are provided
& Inputs can be set to react to falling or rising edges, or both
5. Technical Specifications
Physical specifications:
Supply voltage range:
Standby current:
Maximum current:
Operating temperature:
Output relay rating:
Housing material:
Degree of protection:
Inputs voltage range:
100mA
500mA
-20°C - +85°C
1A @ 30V DC (Output 1 and 2)
ABS
IP55
0 – 24V (0 - 1.6V Low level, 1.7V - 24V
High level)
Functional specifications:
Memory capacity:
Memory retention:
Output pulse time range:
Network required:
1200 individual numbers plus 3000 logs
>200 years
1ms to 50 days (default 1 sec)
GSM 900/1800MHz
SIM card required:
Outputs:
Yes (activated)
Two (potential-free)
Inputs: Two (reacts to rising edge, falling edge, or both)
2. Should the supply voltage fall to below 10.6V, the G-SWITCH-22 will SMS the Admin
Number (first number in the system) that there is a problem with the power supply
6. G-SWITCH-22 GSM Module Identification
1 5
2
3
4
12V-24V DC +
12V-24V DC –
IN 1
GND
IN 2
N/C1
N/O1
COM1
N/C2
N/O2
COM2
1. Diagnostic LEDs:
L1 - Indicates that unit is storing information (backing up)
L2 - 'Heartbeat' indicator; indicates that the unit is powered up and running
L3 - Indicates that the unit is in GPRS Mode, i.e. uploading information to the web interface
L4 - 'Connected to network' indicator
2. Backup Module port
3. Terminals
4. SIM card inside SIM card holder
5. LED Signal strength indicators
6. Antenna
7. IMEI number
(Record your IMEI number here)
8. Defaulting jumper
7. Required Tools and Equipment
& Screwdriver - 3.5mm flat
& Side cutter
& Drill
& Drill bits - 5mm masonry
6mm drill bit
& Silicone sealant
& Fasteners and rawl plugs
8. Mounting Instructions
The housing of the G-SWITCH-22 is weatherproof, allowing it to be mounted externally in order to receive the maximum GSM network signal.
However, the unit can be mounted inside the housing of the device that it is operating, such as the gate motor if the GSM network signal is adequate
(refer to Section 11 – GSM Network Signal Detection).
The following section describes the procedure for mounting the unit to either an internal or external wall. If mounting the G-SWITCH-22 externally, give consideration to its location as it should not be within reach of unauthorised persons.
8A. Remove Cover
6
7
8
Cover
Slot
Screwdriver
8.1. Insert screwdriver into slot and twist. www
.centsys.com
8B. Mount Unit
Cover www
.centsys.com
Circuit board
8.2. Remove the cover and unclip the circuit board from the retaining clips.
Rawl plug
Mounting position
Fastener
8.3. Mark position of the unit against the mounting surface.
8.4. Using a 5mm masonry bit, drill a hole into mounting surface.
8.5. Mount the unit using suitable fasteners.
6mm drill bit
8.6. Use a 6mm drill bit to open the required cable entry hole.
8.7. Re-insert the circuit board and ensure that the retaining clips are holding it in place.
8.8. Fix the cable to the wall using cable saddles.
8.9. Seal all the holes with silicone sealant.
9. Wiring Diagrams
9A. Connections
Power supply
11V-30V DC only
+
-
Input 1 normally-open contact
Input 2 normally-open contact
Relay 1 Output
Relay 2 Output
Cable saddles
Cable
9.1. Supply the unit with 11V-30V DC only.
9.2. The Inputs are potential-free and must be pulled to GND/common for the Module to react.
9.3. Both outputs are potential-free. Some applications might require an external link between NEG and COM.
9.4. Mount the antenna in a suitable place.
9B. Example 1
Typical connection to the D5-Evo sliding gate motor
D5-Evo controller
12V-24V DC +
12V-24V DC -
Input 1
GND
N/01
COM1
N/02
COM2
G-SWITCH-22
9.5. Output 1 is connected to Trg and will open gate fully.
9.6. Output 2 is connected to Ped and will open the gate to pedestrian opening.
9.7. Input 1 will send an SMS to subscribed numbers when the Beam
Alarm is triggered (gate Safety Beams must be activated and mapped to Aux IO).
9C. Example 2
Remote geyser control with feedback
2 pole geyser isolator
N L
11V - 30V DC power supply
In4007 diode
Geyser on
Geyser off
230V
2 pole contactor
N L
Geyser
11V - 30V DC
2 pole relay
10. Insert Activated SIM Card
Locking mechanism
SIM card housing
10.1. Slide the SIM card housing’s locking mechanism up to release the housing.
Ensure that a SIM card that goes into the Module for the first time is not PIN-protected. After the initial setup, please insert the SIM into your mobile phone, activate the PIN code protection and then re-insert the PIN-protected SIM card back into the
G-SWITCH-22.
SIM card housing
10.2. Raise the SIM card housing.
SIM card
SIM card housing
10.3. Insert the activated SIM card and ensure that the SIM card is
correctly oriented. Align the cropped corner to be in the correct
position as per the diagram on the circuit board.
SIM card
Locking mechanism
SIM card housing
10.4. Once the SIM card is inserted correctly in the SIM card housing,
lower the housing onto the circuit board. Then slide the SIM
card housing locking mechanism down to ensure that the SIM
card housing is securely locked in place.
10A. Replace Cover
10.5. Hook the top of the edge of the cover onto the top of the unit.
10.6. Lower the cover and press securely into position.
Cover www
.centsys.com
11. GSM Network Signal Detection
When powered up, the G-SWITCH-22 signal strength indicator LEDs will light up indicating the GSM network signal strength.
The GSM signal strength can be determined based on the combination of the three LEDs that illuminate:
LEDs
4
2
3
2
1
5
3
1
LED
1
1+2
2
2+3
3
Signal strength
1/5
2/5
3/5
4/5
5/5
The signal strength can be queried by sending the ‘Request signal strength’ command (p.xxxx.CO.SS) to the Module.
The querying phone will receive a reply SMS with a value of 5
(strongest) to 1 (weakest) indicating the signal strength.
The GSM signal strength may be enhanced by repositioning the antenna.
Ideally the antenna should be mounted externally, and away from any sensitive electrical components.
Double-sided tape
Antenna
The rear side of the antenna has a double-sided tape backing, which may be used to affix the antenna to a desirable location. Please ensure that the surface to which you affix the antenna is smooth, clean and dry, to ensure reliable adhesion.
Connect with us on: facebook.com/CenturionSystems
YouTube.com/CenturionSystems
@askCenturion
Subscribe to the newsletter: www.CentSys.com/Subscribe
Call Centurion Systems (Pty) Ltd South Africa
Head Office: +27 11 699 2400
Call Technical Support: +27 11 699 2481 from 07h00 to 18h00 (UTC+2)
E&OE Centurion Systems (Pty) Ltd reserves the right to change any product without prior notice
All product and brand names in this document that are accompanied by the ® symbol are registered trademarks in South Africa and/or other countries, in favour of Centurion Systems (Pty) Ltd, South Africa.
The CENTURION and CENTSYS logos, all product and brand names in this document that are accompanied by the TM symbol are trademarks of Centurion Systems (Pty) Ltd, in South Africa and other territories; all rights are reserved.
We invite you to contact us for further details.
0.07.D.0048_22052015_ENG
www.CentSys.com
advertisement
Key Features
- Remote control via mobile phone
- Up to 1200 user activation
- Two outputs, two inputs
- SMS notifications
- Over-the-air firmware update
- G-WEB portal programming