- Industrial & lab equipment
- Electrical equipment & supplies
- Digitronic
- CamCon DC92/I
- User manual
- 7 Pages
Digitronic CamCon DC92/I, DC50, DC90, DC115, DC91, DC91/IO, DC1756-DIAM, DC51 Input extension User Manual
Below you will find brief information for CamCon DC92/I, CamCon DC50, CamCon DC90, CamCon DC115, CamCon DC91, CamCon DC91/IO, CamCon DC1756-DIAM.. CamCon DC92/I is an input extension module that allows for the expansion of the CamCon series electronic cam switch unit. It features 32 high active inputs and is connected via the external interface of the CamCon DC50, 90, and 115 -DICAM. By connecting multiple modules, the total number of inputs can be increased to a maximum of 200. The CamCon DC92/I module is a modular, flexible, and reliable solution for industrial automation systems and can be used in various applications, and industrial equipment, including PLC systems, process control, and machinery automation.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Input - extension CamCon DC92/I Digitronic Automationsanlagen GmbH Steinbeisstraße 3 • D - 72636 Frickenhausen • Tel. (+49)7022/40590-0 • Fax -10 Auf der Langwies 1 • D - 65510 Hünstetten-Wallbach • Tel.(+49)6126/9453-0 • Fax -42 Internet: http://www.digitronic.com • E-Mail: [email protected] 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:[email protected] Site web : www.hvssystem.com Digitronic Automationsanlagen GmbH Input - extension CamCon DC92/I For your attention This instruction manual relates to the CamCon DC92/I from 8/1997. The company Digitronic Automationsanlagen GmbH reserves the right to make changes which present an improvement of the quality or functionality of the device without prior notice. The instruction manual was created with great care, although it may not be error-proof. We would be grateful for any communication relating to any errors you may have found. UP-date You can also obtain this instruction manual on the Internet at http://www.digitronic.com in the latest version as PDF file. Qualified personnel This device may only be started and operated by qualified staff. By qualified we mean personnel who are entitled to handle, to earth and to lable devices, systems and power circuits in accordance with the technology safety standards. Liability (1) The supplier is liable for damages caused by himself or by the owner of the rights up to the sum of the sales price. He is not liable for loss of profits, forfeited savings, intermediate and successive damages. (2) The above mentioned limits to liability do not apply to insurance of named characteristics and damages which were caused deliberately or through negligence. Protection The CamCon DC92/I and this instruction manual are protected by copyright. All rights are reserved. Neither the CamCon DC92/I, nor this document may be copied as a whole or partially, photocopied, reproduced, translated or transferred to electronic media of any kind or into machine readable format without prior written permission by the company Digitronic Automationsanlagen GmbH. Note: Note: Note: We have examined the devices of the CamCon series for year 2000 compatibility and have not found any adverse effects on any functions. CamCon is a registered trademark of the company Firma Digitronic Automationsanlagen GmbH. The devices of the CamCon series comply with the standards for electromagnetic compatibility: EN 55011, EN 55022, EN 55024 Part 2, EN 50082 Part 2, ENV 50140, VDE 0843 Part 2, VDE 0843 Part 4, VDE 0871, VDE 0875 Part 3 ("N"), VDE 0875 Part 11, VDE 0877 Part 2, IEC 801 Part 3, IEC 801 Part 2, IEC 801 Part 4, IEC 801 Part 5. (c) Copyright 1992 - 2004 / File: DC92E.DOC Digitronic Automationsanlagen GmbH Auf der Langwies 1 D-65510 Hünstetten - Wallbach Tel. (+49)6126/9453-0 Fax. (+49)6126/9453-42 Internet: http://www.digitronic.com E-Mail: [email protected] Version: 11.08.04 Page: 2 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:[email protected] Site web : www.hvssystem.com Digitronic Automationsanlagen GmbH Input - extension CamCon DC92/I Content 1. Introduction .......................................................................................................................................... 3 2. Assembling .......................................................................................................................................... 4 3. Status LED........................................................................................................................................... 4 4. Dimensions .......................................................................................................................................... 4 5. Electrical connections .......................................................................................................................... 5 5.1. Clamp allocation ............................................................................................................................... 5 5.1.1. Clamp allocation of power supply .................................................................................................. 5 5.1.2. Clamp allocation of the inputs........................................................................................................ 5 5.1.3. Pin allocation of the external interface........................................................................................... 6 5.2. The Inputs ......................................................................................................................................... 6 6. Technical data...................................................................................................................................... 7 1. Introduction The CamCon DC92/I module is used as an input extension for the electronic cam-switch unit of the CamCon series. Each CamCon DC92 module has got 32 inputs, it can be connected by means of the external interface of the CamCon DC50, 90 and 115 -DICAM. By a series connection of several CamCon DC92 modules it is possible to increase the total number of inputs at one Camcon to at maximum 200 inputs. Thus, at a CamCon DC51 having 16 inputs another 5 CamCon DC92 modules could be connected. With 5 CamCon DC91/IO modules, for instance, you have got additionally 160 inputs at your disposal. Version: 11.08.04 Page: 3 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:[email protected] Site web : www.hvssystem.com Digitronic Automationsanlagen GmbH Input - extension CamCon DC92/I 2. Assembling The CamCon DC92 input extension module is locked on an EN carrier bar in the switch cabinet. The earthing clamps shall be connected to the central earth connection point of the mounting panel on the shortest possible way. All cable connections shall be established in a dead condition! Each CamCon DC9X module shall be connected with the supply voltage which amounts to 24VDC +/-20 %. The external interface of the CamCon DC50,90,115 and/or 1756-DIAM becomes connected via a cable of type: KK91/IO-XX with the 9pol. D Sub pin plug "external inter. in" at the CamCon DC92 module connected. Each further CamCon DC92 oder DC91 module is attached with a cable of the same type to the plug "external inter out". The data line of the CamCon DC9X/IO modules are connected to each other via optical-couplers, thus being free of potentials. For monitoring the data exchange you should program the safety output of the CamCon at the last CamCon DC91/IO module, because this will switch off in the case of an interruption of the cable connection. 3. Status LED The CamCon DC91 module has got 2 additional status LED (see chapter 4. Dimensions). LED 1 LED 2 Indicates to supply voltage. indicates that for the moment no data exchange via CamCon and the DC92 is aktiv. The possible causes are: the cable length stopped at the CamCon exceeds the permissible border of 300 meters, the CamCon is switched off, and/or data exchange is interrupted (cable broken). 4. Dimensions LED 1 LED 2 The following carrier rails may be used to adjust the case: Version: 11.08.04 Page: 4 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:[email protected] Site web : www.hvssystem.com Digitronic Automationsanlagen GmbH Input - extension CamCon DC92/I 5. Electrical connections . 5.1. Clamp allocation 5.1.1. Clamp allocation of power supply Clamp Clamp Clamp Clamp Clamp Clamp 11: 12: 13: 14: 15: 16: Earth connection/shielding Earth connection/shielding 0V 0V +24V DC Power supply +24V DC Power supply 5.1.2. Clamp allocation of the inputs Clamp 17 + 35: Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp 18: 19: 20: 21: 22: 23: 24: 25: 26: 27: 28: 29: 30: 31: 32: 33: Clamp 34 + 52: Note: 0V of the input, connected to Clamp 13 and 14. Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp Clamp 36: 37: 38: 39: 40: 41: 42: 43: 44: 45: 46: 47: 48: 49: 50: 51: Input 17 Input 18 Input 19 Input 20 Input 21 Input 22 Input 23 Input 24 Input 25 Input 26 Input 27 Input 28 Input 29 Input 30 Input 31 Input 32 +24V DC for power supply of external inputs connected to Clamp 15 and 16. Clamp 15, 16, 34 and 52 are connected with each other. Clamp 13, 14, 17 and 35 are connected with each other. Clamp 11 and 12 are connected with each other. Version: 11.08.04 Page: 5 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:[email protected] Site web : www.hvssystem.com Digitronic Automationsanlagen GmbH Input - extension CamCon DC92/I 5.1.3. Pin allocation of the external interface The CamCon DC91 module has an external interface via which the data exchange with the camswitch is processed. Via the interfaceinput also the data exchange with the CamCon DC 50 i.e. DC 90 or DC115 is done. The interface output is used for the data exchange with another CamCon DC91 module. By this way of switching it is possible to switch up tio 7 CamCon DC91 module to a CamCon DC50 i.e. DC90 or DC115. A shielded 6 pole data cable with pairly wired cores is required for this purpose. the maximum wiring distance is 300 meters. As an option, distances up to 100 meters are possible. the data exchange is realised by optical couplers and therefore free of potentials. For the monitoring of the data exchange you should program the safety output of the CamCon DC50, DC90 or DC115 at the last CamCon DC91, for it will switch of if the wire is broken. DSUB 9 male and female plug: Pin 1,4,7 Pin 2 Pin 6 GND TxD + TxD - CamCon DC50 external Pin 8 Pin 3 CLK + CLK - CamCon DC92/I external external Pin 5 Pin 9 RxD + RxD CamCon DC91 external 5.2. The Inputs The CamCon DC92 Modul has got 32 inputs. These inputs function with highly active 24 V signals and are not free of potentials. For each input one Status LED shows the status. The input resistance amounts to approx. 5.7 KOhm. Input circuit: Version: 11.08.04 Page: 6 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:[email protected] Site web : www.hvssystem.com Digitronic Automationsanlagen GmbH Input - extension CamCon DC92/I 6. Technical data Display ................................................................ 32 yellow LED for each input. 1 red LED for error messages. 1 yellow LED for power supply. Number of inputs................................................. 32 Length of the connecting cable between CamCon and CamCon DC91/IO.......... max. 300 m (optionally up to 1000 meters) Supply voltage..................................................... 24VDC ±20 % Current consumption........................................... approx. 100mA. Input resistance................................................... ca. 5.7kOhm Connections for: Voltage supply..................................................... via plug-in screw clamps IP20 Inputs ................................................................. via plug-in screw clamps IP20 Assembly............................................................. convenient snap-on assembly; carrier bar according to EN 50 022, may be set in rows. Dismantling ......................................................... by pulling back the snap lock. Dimensions ......................................................... Please, refer to chapter 4. Dimensions at page 4. International protection........................................ The housing fulfils IP20. Operation temperature........................................ 0°C ... + 55° C Weight.................................................................approx. 500 g Version: 11.08.04 Page: 7 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:[email protected] Site web : www.hvssystem.com
advertisement
Key Features
- 32 high active inputs
- Extends CamCon series input capability
- Modular design for scalability
- 24V DC power supply
- External interface for connectivity
- Data exchange via optical couplers
- Status LEDs for monitoring