FIRETEK 755 FM smoke alarm Instructions
Below you will find brief information for smoke alarm 755FM. The 755FM is a 240V a.c. flush-mounted mains-powered ionization smoke alarm with a 9V d.c. battery backup. It is designed to provide early warning of a fire by detecting smoke particles in the air. The unit is equipped with a loud siren and a flashing red LED to alert occupants in case of a fire. Learn how to install, operate and troubleshoot your new smoke alarm 755FM.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Information on Smoke Alarms
WHAT SMOKE ALARMS CAN DO
Smoke alarms can only HELP protect your family and home against loss from a fi re. For maximum protection install smoke alarms in every bedroom, and every other area of the home, making sure the people in the home will be able to hear and respond to the alarm sound.
WARNING – Smoke alarms may give you a warning of fi re and smoke but only if you install, use and maintain them as recommended in this instruction leafl et.
WHAT SMOKE ALARMS WILL NOT DO
A smoke alarm will not work without power – Your smoke alarm needs mains power (220-240V) and a good battery (9V) that is installed correctly in order to operate.
A smoke alarm will not sense a fi re when smoke cannot reach the unit – If a fi re starts in a chimney, wall, roof, the other side of a closed door or any other isolated area, the smoke alarm may not sense the smoke and may not give a warning. If you do not have a smoke alarm in the bedroom and sleep with the door closed, a fi re inside the bedroom may not sound an alarm located in another room. Therefore it is recommended that a smoke alarm be installed inside and outside all bedrooms. A smoke alarm will not promptly sense a fi re except in the area in which the smoke alarm is installed.
All types of smoke alarms have limitations – No type of smoke alarm can sense every kind of fi re or smoke every time.
CHOOSING YOUR SMOKE ALARM
Fire types – A photoelectric alarm like the Clipsal 755PFM responds faster to large smoke particles, while an ionisation alarm like the Clipsal 755FM (this unit) responds faster to smaller smoke particles. Smouldering fi res produce more large particles, so this type of fi re will be more quickly detected by the 755PFM photoelectric alarm. Flaming fi res produce more small smoke particles and this type of fi re will be more quickly detected by an Ionisation Alarm like the 755FM. The type of fi re likely to occur in the location is therefore an important consideration when choosing which type of smoke alarm to install.
How a photoelectric alarm works – A photoelectric detector uses a special light source and a light sensor to measure smoke density. The light source is constantly on but the light beam is angled away from the light sensor. When smoke enters the chamber, the smoke particles scatter some of the light toward the sensor. As the smoke density increases, more light is scattered towards the sensor. When the amount of light scattered into the sensor reaches a predetermined threshold, the unit goes into alarm mode and the alarm will sound to alert occupants.
Nuisance alarms – Because an ionisation type alarm is sensitive to small smoke particles, it will respond more quickly to particles typically given off during cooking, even where there may be no danger. On the basis of this “nuisance” alarming, consideration should be given to installing photoelectric alarms like the 755PFM near kitchen areas. While the home owner will lose some warning time in a fi re that generates smaller smoke particles, they will also reduce the occurrence of the one nuisance that results in a lot of smoke alarms being disabled.
Using a smoke alarm in a smokey area like a kitchen or in a high humidity area such as a bathroom can cause false alarms. Do not remove the battery to quieten the alarm, or take the alarm down. A smoke alarm will not protect you if it is not powered or if it is not there. A smoke alarm may not always warn you about fi res caused by the following:
• Smoking in bed •Incorrect storage of fl ammable materials
•Children playing with matches or lighters •Over-loaded electrical circuits.
Recommended Location of Alarms
• Locate the fi rst alarm in the immediate areas of the bedrooms. Try to protect the exit path as the bedrooms are usually furthest from an exit. If more than one sleeping area exists, locate
additional alarms in each sleeping area.
• Locate additional alarms to protect any stairway, as stairways act like chimneys for smoke and heat.
• Locate at least one alarm on every fl oor level.
• Locate an alarm in any area where a smoker sleeps or where electrical appliances are operated in sleeping areas.
• Smoke, heat and other combustion products rise to the ceiling and spread horizontally. Mounting the detector on the ceiling in the centre of the room places it closest to all points in the
room. Ceiling mounting is preferred in ordinary residential construction. However, in mobile homes, wall mounting on an inside partition is required to avoid the thermal barrier that
may form at the ceiling.
• When mounting alarm in the ceiling, locate it a minimum of 30cm from a side wall and 30cm from any corner (see Diagram A).
• When mounting alarm on a wall, use an inside wall with the alarm a maximum of 50cm below the ceiling and at least 30cm from any corner (see Diagram A).
50cm
Avoid These Locations
• Do not install a smoke alarm within one metre of heating and cooling supply vents or within one metre of return air or fresh air vents. Smoke may be blown away from the smoke alarm by the supply vents, or could be diffused or reduced by being diverted into the return air vent.
• Do not install your smoke alarm in an area where the temperature may fall below 5°C or rise above 45°C. Smoke alarms are designed to work safely only within these temperature ranges and failure to alarm, improper alarms or nuisance alarms may result from operation outside these temperature limits.
• Do not install a smoke alarm in a damp or very humid area such as bathrooms with showers, where the normal humidity may rise above 90%. Above this level, moisture may condense
inside the smoke chamber and cause false alarms. The smoke alarm may also become unstable below 10% relative humidity.
• Do not install a smoke alarm in an area where particles of combustion are normally present, such as garages or kitchens etc, as this can cause false alarms.
• Do not install a smoke alarm in dusty or dirty areas, such an installation cannot be relied on. An accumulation of dust and dirt in the sensing chamber may block the openings and prevent an alarm, or may get inside the alarm and cause false alarms. If a smoke alarm is required in such an area, vacuum it frequently and test it according to the ‘Operation and
• Do not install a smoke alarm in the dead air space in the corner where the wall meets the ceiling. If in doubt as to the exact location of mounting, for your safety, contact your local fi re
department for help choosing a location.
• Do not install a smoke alarm where bugs or insects are present before eliminating or minimising the problem. Although all smoke alarms built since 1985 are made to prevent bugs
from entering the detection chamber, bugs may build up on chamber openings and prevent smoke from entering. If bugs are present, vacuum the unit frequently as described in the
• Do not install a smoke alarm within one metre of a fl uorescent or compact fl uorescent lamp. Electrical ‘noise’ may cause nuisance alarms.
5
Operation and Troubleshooting
INDICATOR
Alarm sounds and the red LED is blinking rapidly.
Green LED ON.
Green LED OFF.
Mains power may be disconnected.
Red LED Flashes every 40 to 60 seconds.
Red LED not fl ashing.
Audible Beep is heard once every minute.
When Test / Hush button is pressed for three seconds alarm sounds briefl y.
When Test / Hush button is pressed for three seconds alarm does not sound.
Smoke alarm is sounding, you press the
Test / Hush button and it stops.
Smoke alarm is sounding and you press the Test /
Hush button but nothing happens.
Smoke alarm body will not close on the base.
Red LED is off and alarm is sounding.
SIREN
Smoke has activated the smoke alarm.
MEANING
Vacate the building and call the fi re brigade
(see ‘what to do if alarm sounds’).
240V mains power ON.
240V mains power OFF.
Red LED indicates the smoke alarm is functioning correctly.
Battery may be reversed. No battery present. Battery completely fl at.
Low battery indicator is warning the battery needs replacing.
The smoke alarm horn is indicating all electronic circuitry, horn and battery are working.
Check green LED is ON and red LED is fl ashing once every
40 to 60 seconds.
Normal operating condition.
Check mains power ON. Main circuit breaker may have tripped. Wiring could be reversed.
Normal operating condition.
Reinstall battery around the correct way or replace battery.
Replace 9V battery with a specifi ed new battery.
Normal test condition.
Test weekly to ensure proper operation.
Turn mains power back ON and replace battery. If smoke alarm still won’t ‘TEST’, replace.
‘Hush’ feature has been activated for 10 minutes providing the smoke density does not increase.
Normal condition. Clear the smoke as soon as you can.
Smoke density is too high for the Hush feature to activate.
9V battery not present.
Smoke has activated an interconnected alarm, located somewhere else in the building.
Vacate the building and call the fi re brigade.
(see ‘what to do if alarm sounds’).
Install a 9V battery.
Vacate the building and call fi re brigade. In the event of a false alarm [use caution], locate the source of the alarm. This unit will have its alarm sounding and red LED blinking rapidly.
Maintenance, Repairs and Service
Maintenance: It is recommended that the smoke alarm is inspected monthly to ensure it is free from dirt, dust and insects. The alarm can be vacuumed or brushed with a soft brush to remove dust, dirt or kitchen grease that has accumulated. A small amount of surface spray around the alarm should deter insect ingress.
ALWAYS TEST THE SMOKE ALARM AFTER CLEANING.
Repairs / Service: The smoke alarm uses a very small amount of radioactive element, which is safely contained within the chamber assembly. If the smoke alarm is defective in any way, do not tamper with the unit. If the warranty period has expired then dispose of the unit as indicated below. Unit does not contain any user serviceable parts except the battery.
DO NOT, UNDER ANY CIRCUMSTANCES, TAMPER WITH THE SEALED RADIOACTIVE SOURCE.
Disposal: Please contact local authorities for advice. Some states permit disposal in household rubbish collection. Alternative disposal might not be permitted – contact local authorities for advice.
Limited 5 Year Warranty
Clipsal Australia Pty Ltd warrants your product to be free from defects in material and workmanship for a period of fi ve years from the date of purchase. The warranty applies only to the original consumer purchaser and only to products used in normal use and service. If this product is found to be defective, Clipsal Australia’s only obligation, and your exclusive remedy, is the repair or replacement of the product, at Clipsal Australia’s discretion, provided that the product has not been damaged through misuse, abuse, accident, modifi cations, alteration, neglect or mishandling (excluding any labour cost relating to removal or reinstallation of product and transport cost). This warranty shall not apply to any product, which is found to be improperly installed, setup or used in any way not in accordance with the instructions supplied with the product. This warranty shall not apply to any batteries used in the product or to any damage caused by such batteries. If your product fails to operate satisfactorily, please return it to the point of purchase or Clipsal Australia Pty Ltd.
CLIPSAL AUSTRALIA PTY LTD DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY, WHETHER EXPRESSED OR IMPLIED, OF FITNESS FOR
A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN. NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW, SHALL
EXTEND BEYOND THE TERM OF THIS WARRANTY UNLESS SUCH LAW OTHERWISE PROVIDES. CLIPSAL AUSTRALIA PTY LTD SPECIFICALLY DISCLAIMS ANY
LIABILITY AND SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE, INCLUDING, BUT NOT LIMITED TO, DAMAGES TO ANY
EQUIPMENT WITH WHICH THIS PRODUCT IS USED.
No agent, representative, dealer or employee of the company has the authority to increase or alter the obligations or terms of this warranty. Clipsal Australia Pty Ltd reserves the right to change specifi cations or designs described in this manual without notice and without obligation.
This smoke alarm complies with:
AS3786
AS/NZS3100
Australian Electrical Authority
Certifi cate of Suitability CS/1253/S
Am241 1.0 microcuries
(37kBq)
Head Offi ce
33-37 Port Wakefi eld Road
Gepps Cross South Australia 5094
Email: [email protected]
Website: pdl.com.au
National Customer Care Enquiries
1300 2025 25
National Customer Care Facsimile
1300 2025 56
F1842/02
New Zealand & International Enquiries
Schneider Electric (NZ) Ltd
PO Box 15355 New Lynn, Waitakere 0640
Auckland New Zealand
Freephone 0800 652 999
Telephone +64 9 829 0490
Facsimile +64 9 829 0491
Freefax 0800 101 152
Schneider Electric reserves the right to change specifi cations, modify designs and dis con tin ue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifi cations and other in for ma tion in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.
© Schneider Electric
This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Schneider Electric.
Schneider Electric acknowledges that the Australian Standard
Certifi ed Product logo is a trademark of SAI Global, and that the Activfi re Certifi ed logo is a trademark of CSIRO.
6
CLIPCOM 19681 August 2009
SMOKE ALARM 755FM
240V a.c. Flush Mounted Mains Powered Ionisation Smoke Alarm with 9V d.c. Battery Backup
PLEASE LEAVE THESE INSTRUCTIONS WITH THE HOME OWNER, TO BE RETAINED FOR THE LIFE OF THE ALARM. THIS SMOKE ALARM REQUIRES INSTALLATION BY A LICENSED
ELECTRICAL CONTRACTOR.
Read All Instructions Before Installation and Operation
Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good condition. We recommend the smoke alarm be replaced after 10 years of normal service. DO NOT try to open or repair the smoke alarm yourself. No user serviceable parts are inside.
Specifi cations
Main Power Source:
Secondary Power Source:
Operating Current:
Battery Life:
Sensing Type:
Operating Temperature:
Ambient Humidity:
Interconnecting:
220-240V a.c. 50Hz
9V d.c. carbon zinc or alkaline battery
35mA
One year approximately
Ionisation. Americium 241 1kBq (one microcurie)
5°C to 45°C
10% to 90%
40 Alarms over 150 metres maximum
Terminal Provisions:
Horn Level:
Visual Indicators:
Approvals:
Complies with:
Certifi cate of Suitability:
Active, Neutral, Loop and Interconnect terminals, each accommodates 2 x 2.5mm
2
85dB at 3 metres minimum
Green LED for mains power ON
Red LED for warning and low battery indication
ActivFire Certifi ed
AS3786:1993
AS/NZS 3100:2002
CS/1253/S
IMPORTANT OVERVIEW OF
THE INSTALLATION PROCESS
Choose a location for
your new fl ush mount smoke alarm
Select the correct alarm for your situation
(Photoelectric V’s Ionisation Type)
Install alarm
Test alarm
Red Indicator
Fast fl ash
Medium fl ash
Slow fl ash
Off
Leave instructions with home owner
OPERATION GUIDE
Siren
On
Off
Meaning
Local alarm
Unit in hush mode
Chirps
On
Off
Low battery condition
Remote alarm
All power lost
1
Green Indicator Siren Meaning
On
Off
N/A Mains power OK
N/A Mains power lost
See installation manual for further details
When alarm beeps at approximately one minute intervals, replace battery
1
2
4
90mm
Cut/Drill out 90mm
Remove sensor head assembly from fi xed mounting base
3
5 terminal screws
Open terminal cover, remove if required
Connect wiring as described below
Electrical Installation
UNIT WIRING DETAILS
1.Strip the Active, Neutral and Interconnect (if used) wires back.
2. Remove the two terminal cover screws and fl ip open the terminal cover to expose the wiring terminals. The cover may be completely removed
if required during installation.
3. Connect the wires to the correct terminals on the mounting base and ensure the terminal screws are fully tightened.
4. Remove any of the tear away cable entry apertures in the terminal cover as necessary. Reinstall cover and fl ip closed. Seal the base with the
two terminal cover screws provided.
5. Mount base as shown. (fi gure 9 above)
6. Insert battery and install sensor head. Note the sensor head cannot be installed without a battery being present.
7. Turn on mains power and check the green and red LEDs function. Green LED should glow to indicate mains power present.
Red LED will pulse every 40-60 seconds to indicate correct operation and the 9V battery is ok.
8. ‘Test the unit’. To ensure correct operation of the alarm press the Test / Hush button.
WARNING
• All 220-240V wiring must be carried out by a licensed electrician.
• All 220-240V wiring must comply with AS/NZS3000 wiring rules.
• The sensor head cannot be installed without a 9V battery being present.
DO NOT LEAVE THE INSTALLATION UNTIL THE RED AND GREEN LEDs, AND THE ALARM
HAVE BEEN CHECKED FOR CORRECT OPERATION.
Red
220-240V a.c.
1mm 2 minimum
Black
2
Unit Wiring
Active/Line (A)
Earth/Loop (E)
Neutral (N)
Interconnect (I)
A N I
6
8
10
Tear out appropriate cable entry apertures as required and close cover
This illustration shows cable entry aperture options
7
9
Install mounting base into ceiling. Tighten screws until ceiling clamps fi rmly engage, locking the base
11
Seal terminal cover using screws supplied
What to do if Alarm Sounds
• Leave immediately by following your escape plan. Every second counts so don’t waste time getting dressed or picking up valuables.
• In leaving, don’t open any inside door without fi rst feeling its surface. If hot, or if you see smoke seeping through cracks, don’t open that door! Instead, use an alternative exit. If inside door
is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rushes in.
• Stay close to the fl oor if air is smokey. Breathe shallowly through a cloth, wet if possible.
• Once outside, go to your selected meeting place and make sure everyone is there.
• Call the fi re brigade from your neighbour’s home – not from yours!
• Don’t return to your home until fi re offi cials say that it is alright to do so.
Most Importantly...
DON’T PANIC!
Develop and Practise a Plan of Escape
• Have a family meeting and discuss your escape plan, showing everyone what to do incase of fi re.
• Determine a place outside your home where all of you can meet if a fi re occurs e.g. letterbox.
• Familiarise everyone with the sound of the smoke alarm and train them to leave your home when they hear that sound.
• Identify childrens’ bedrooms with red stickers placed in the upper left corner of the windows.
• Practise a fi re drill at least every six months. Practice allows you to test your plan before an emergency.
You may not be able to reach your children. It is important they know what to do!
Hush or Silence Feature
• This smoke alarm has a built in Hush or Silence feature incorporated into the Test button.
• If cooking or other non-hazardous sources cause the alarm to sound it can be temporarily silenced by pressing the Test / Hush button
for three seconds.
• The alarm then enters a dormant period for 10 minutes.
• If the smoke density increases during this period (i.e. from a fi re) the unit will go into alarm mode.
• After the 10 minute dormant period the smoke alarm resumes normal operation and two beeps will sound to indicate this.
Press to silence after checking source of smoke
Cl ip s a l
Replacing the Backup Battery
The secondary backup power for the smoke alarm is supplied by a 9V carbon zinc or alkaline battery. The battery should last at least one year under normal operating conditions.
IT IS RECOMMENDED YOU REPLACE THE BATTERY ON A DAY YOU CAN REMEMBER EVERY YEAR i.e. birthday, daylight saving.
Test to ensure correct
Install battery and install sensor head as shown.
NOTE: Sensor head cannot be installed without battery
Interconnecting Smoke Alarms
HOW INTERCONNECTED ALARMS FUNCTION
• Interconnecting smoke alarms is a method of joining a series of alarms so that if any one alarm senses smoke,
all alarms in the series will operate (go into alarm mode).
• 9V signal on the I and N wires is used to alarm all the other Interconnected alarms.
• A combination of Clipsal 755 Series Ionisation or Photoelectric Smoke Alarms can be used on
WARNING
• All interconnected smoke alarms must be supplied from a single circuit.
• A common Neutral must be used for the Interconnect to function.
• DO NOT connect the Interconnect wire to Active or Neutral.
• A maximum of 40 Clipsal 755 Series Smoke Alarms can be installed on one circuit.
A N I
Terminal
A - Active / Line
E/Loop - Earth or Loop
N - Neutral
I - Interconnect
Use minimum of 1mm 2 250V insulated wire for all wiring including interconnecting
220-240V a.c.
1mm 2 minimum
Black
Red
Interconnecting Multiple Units
(40 alarms maximum)
150 metres maximum between fi rst and last interconnected smoke alarm
Interconnect (I)
Neutral (N)
Active/Line (A)
A N I
3
A N I
The smoke alarm has a low audible beep.
If the smoke detector sounds a ‘beep’ once a minute,
REPLACE THE BATTERY
WITH A NEW ONE.
NOTE:
• Testing ensures all electronic circuitry, horn and battery are working correctly.
• If no alarm sounds, check the battery is installed the correct way around or replace the battery.
• If the battery is new and installed correctly and the alarm still doesn’t sound, replace the smoke alarm.
• For a mobile home, test weekly and after every journey.
• If premises are unoccupied (more than a few days) then a battery test should be undertaken upon return.
• When testing any interconnected smoke alarms, all connected units should also go into alarm mode.
Recommended Batteries - Energizer 522, Duracell MN1604, Eveready A522 or 1222
Test unit by pushing Test button for three seconds until the alarm sounds.
Use only recommended batteries that are readily available at local supermarkets or hardware stores.
Test unit once per month
Replace battery once per year
Replace unit every ten years
For your convenience, a handy
‘BATTERY CHANGE REMINDER’ sticker sheet is provided.
Place one sticker for each month on your calendar or wall planner to help you remember to service your smoke alarm on a regular basis.
BATTERY CHANGE REMINDER STICKER
4
advertisement
Key Features
- Ionization smoke detection
- Loud siren and flashing LED
- 240V a.c. mains power with 9V d.c. battery backup
- Hush feature to silence nuisance alarms
- Interconnecting capability for multiple units
- Easy installation and operation
- Limited 5 year warranty
- Monthly inspection recommended
- Battery replacement needed annually
- Unit replacement after 10 years