Arlec UC0033, UC0034 bar light Installation Instructions

Arlec UC0033, UC0034 bar light Installation Instructions

Below you will find brief information for bar light UC0033, bar light UC0034. This product is designed for indoor use only. It can be either wall mounted or fixed to the underside of a cabinet. You can link multiple lights together to create a lighting system that meets your needs. The maximum load for linked lights is 250W. This manual will guide you through the installation process and provide care and cleaning instructions.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Arlec bar light UC0033, bar light UC0034 Installation Instructions | Manualzz

Warranty

Arlec guarantees this product in accordance with the Australian Consumer Law.

Arlec also warrants to the original first purchaser of this product (“you”) from a retailer that this product will be free of defects in materials and workmanship for a period of 12 months from the date of purchase; provided the product is not used other than for the purpose, or in a manner not within the scope of the recommendations and limitations, specified by Arlec, is new and not damaged at the time of purchase, has not been subjected to abuse, misuse, neglect or damage, has not been modified or repaired without the approval of Arlec and has not been used for commercial purposes (“Warranty”).

If you wish to claim on the Warranty, you must, at your own expense, return the product, and provide proof of original purchase and your name, address and telephone number, to Arlec at the address below or the retailer from whom you originally purchased the product within 12 months from the date of purchase.

Arlec will (or authorise the retailer to) assess any claim you may make on the Warranty in the above manner and if, in Arlec’s reasonable opinion, the Warranty applies, Arlec will at its own option and expense (or authorise the retailer to) replace the product with the same or similar product or repair the product and return it to you or refund the price you paid for the product. Arlec will bear its own expenses of doing those things, and you must bear any other expenses of claiming on the Warranty.

The Warranty is in addition to other rights and remedies you may have under a law in relation to the product to which the Warranty relates.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.

You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

CPIN002529

Installation Instructions

2

bar light

Arlec Australia Pty. Ltd. ACN 009 322 105 (“Arlec”) gives the Warranty.

Arlec’s telephone number, address and email address are:

Customer serviCe: (03) 9982 5111

Building 3, 31 – 41 Joseph Street, Blackburn North, Victoria, 3130

Blackburn North LPO, P.O. Box 1065, Blackburn North, 3130

Email: [email protected]

4

CPIN002529

LINKABLE

D

Y

UC0033

Important!

Please read these instructions carefully.

Due to continuous research and development the specifications

in here are subject to change without notice.

CPIN002529

InstallatIon

Decide on a suitable location to mount the light fitting. This product can be either wall mounted or fixed to the underside of a cabinet.

Do not mount the fitting in a position where it may be subjected to excessive heat or steam e.g. above cooktop.

Attach using the two screws supplied. These must be secured firmly in position. and be capable of permanently supporting the weight of the light fitting.

Halogen

Bulbs

safetY InformatIon

• This product is designed for

indoor use only.

• Except for the halogen bulbs

there are no user serviceable

parts. Repairs, including

replacement of supply flexible cord,

must only be performed by a

suitably qualified person.

• When linking lights together, do not

exceed 250W (1A) maximum load.

Mounting

Screw

Linking Cable

Mounting

Screw

2

Bulb Covers

Power Cable

The modular light fittings can be linked together to draw a maximum load of 250W

1 2

Max Total Load 250W (1A)

3

Figure 1.

Care anD CleanIng

• Always switch off power

before cleaning.

• Clean the exterior with a damp

cloth, then wipe dry.

• Do not use abrasive cleansers

or solvents.

BUlB replaCement

1. Switch off power to light fitting.

2. Remove bulb cover by rotating

anti-clockwise and lifting.

4. Remove failed bulb.

5. Replace with new bulb of same

type and wattage. When inserting

a replacement bulb, do not touch

with bare hands (oils from the

hands can shorten bulb life).

Use a tissue to handle the bulb.

6. Replace bulb cover in position.

See Figure 1.

speCIfICatIons

Supply Voltage: 230-240V~

Frequency: 50Hz

Halogen Bulb: 2 x 12V G4

20W (UC0033)

3 x 12V G4

20W (UC0034)

Minimum allowed distance from lighted objects is 0.3m.

3

advertisement

Key Features

  • Indoor use only
  • Wall or cabinet mounting
  • Linkable design
  • Maximum load: 250W
  • Easy installation
  • Halogen bulbs
  • Bulb replacement instructions
  • Care and cleaning guidance

Frequently Answers and Questions

What is the maximum load for linked lights?
The maximum load for linked lights is 250W (1A).
Can I mount the light fitting above a cooktop?
No, do not mount the light fitting in a position where it may be subjected to excessive heat or steam.
How do I replace the halogen bulbs?
Switch off power to the light fitting, remove the bulb cover, remove the failed bulb, replace with a new bulb of the same type and wattage, replace the bulb cover. See Figure 1.