Flashers
Series Included
Solid State
FSU1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
FS126, FS127, FS146, FS147 . . . . . . . . . . . . . . . . . . . . . . . . . .104
FS143, FS152, FS162 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
FS200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
FS300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
FS400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
AF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Relay
FS500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Chasers
Flashers
SC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
SC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
www.ssac.com • 800-843-8848 • fax: 605-348-5685
103
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Flashers
FSU1000 / FS100 Series
The FSU1000 incorporates an onboard adjustable
flash rate of 10 to 100 FPM and a universal input
voltage in one device. Its circuitry is encapsulated
and is capable of controlling loads of up to 20A.
The versatility of the FSU1000 makes it ideal
for applications where various flash rates and
operating voltages are required.
Operation
When input voltage is applied to terminal 2 and the load
(lamp), the load energizes steadily. When input voltage
is applied to terminal 3, the output flashes.
Optional Low Current Switch (S1)
This low current switch could be a limit switch or contact.
While open, the operator sees the load (lamp) ON and
operating. When the limit switch closes, the load (lamp)
flashes to attract attention.
Order Table:
Rating
1A
6A
10A
20A
Inrush Rating
10A
60A
100A
200A
Part Number
FSU1000
FSU1003
FSU1004
FSU1005
For more information see:
Appendix A, page 164 for Flasher (NC) function.
Appendix B, page 165, Figure 4 for dimensional drawing.
Appendix C, page 168, Figure 1 for connection diagram.
Features:
• All solid state – no moving parts or contacts
• Onboard adjustable flash rate
• Loads up to 20A
• High inrush up to 200A
• Universal voltage 24 to 240VAC
Approvals:
Auxiliary Products:
• Female quick connect:
P/N: P1015-13 (AWG 10/12)
P/N: P1015-64 (AWG 14/16)
P/N: P1015-14 (AWG 18/22)
• Quick connect to screw adaptor:
P/N: P1015-18
Available Models:
FSU1000
FSU1003
FSU1004
Specifications
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . .
Flash Rate . . . . . . . . . . . . . . . . . . . . . . .
ON/OFF Ratio . . . . . . . . . . . . . . . . . . .
Input
Range/Frequency . . . . . . . . . . . . . . . .
Output
Load Type . . . . . . . . . . . . . . . . . . . . . . .
Maximum Load Rating . . . . . . . . . . . .
Inrush . . . . . . . . . . . . . . . . . . . . . . . . . . .
ON/OFF recycling solid-state flasher (continuous duty)
Adjustable 10 - 100 FPM
≅ 50%
24 to 240VAC/50/60Hz
Inductive, resistive, or incandescent
1, 6, 10, or 20A steady state
10 times steady state current
Mechanical
Mounting* . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . .
Termination . . . . . . . . . . . . . . . . . . . . .
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . .
Environmental
Operating / Storage Temperature . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation
Upon application of input voltage, the T2 OFF time
begins. At the end of the OFF time, the T1 ON time begins
and the load energizes. At the end of T1, T2 begins and
the load de-energizes. This cycle repeats until input
voltage is removed.
Reset: Removing input voltage resets the output and the
sequence to T2 .
Output Rating
Specifications
1A
1A
2A
1A
1A
2A
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . .
Flash Rate . . . . . . . . . . . . . . . . . . . . . . .
Custom Flash Rates Available . . . . . .
ON/OFF Ratio . . . . . . . . . . . . . . . . . . .
Input
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Line Frequency . . . . . . . . . . . . . . .
Output
Output . . . . . . . . . . . . . . . . . . . . . . . . . .
Load Type . . . . . . . . . . . . . . . . . . . . . . .
104
-20° to 60°C (240VAC +50°C) / -40° to 85°C
1A units: ≅ 2.4 oz (68 g)
> 6A units: ≅ 3.9 oz (111 g)
Features:
• Fixed flash rate 75 FPM
• Custom flash rate 45 - 150 FPM
• 1 or 2A output
• 24 or 120VAC
• Small size: 1.5 x 0.94 in. (38 x 23.9 mm)
Approvals:
Available Models:
FS126
FS126-45
FS126-60
FS126RC
FS126RC-90
FS127
FS146
FS146RC
For more information see:
Appendix A, page 164 for Flasher (OFF First) function.
Appendix B, page 165, Figure 12 for dimensional drawing.
Appendix C, page 168, Figure 2 for connection diagram.
Order Table:
Input
Encapsulated
*Units rated > 6A must be bolted to a metal surface using the included heat sink compound.
The maximum mounting surface temperature is 90°C.
The FS100 Series (low amp) may be used to control
inductive, incandescent or resistive loads. This
series offers a 1A (fullwave) or a 2A (halfwave)
steady state, 10A inrush solid-state output and
may be ordered with an input voltage of 24 or
120VAC. The FS100 Series offers a factory fixed
flash rate of 75 FPM or may be ordered with a fixed,
custom flash rate ranging from 45 to 150 FPM.
Ideal for OEM applications where cost is a factor.
120VAC
120VAC
120VAC
24VAC
24VAC
24VAC
Surface mount with one #10 (M5 x 0.8) screw
2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
0.25 in. (6.35 mm) male quick connect terminals
Output Type
AC, Fullwave
AC, Fullwave
AC, Halfwave
AC, Fullwave
AC, Fullwave
AC, Halfwave
Load Type*
A
B
A
A
B
A
Part Number
OFF/ON solid-state flasher (continuous duty)
Factory fixed at 75 FPM ±20%
From 45 - 150 FPM ±20%
≅ 50%
24, 120VAC, ±15%
50/60Hz
Fullwave AC or Halfwave rectified AC
Incandescent, resistive, or inductive
(Choose RC suffix for inductive loads)
FS126
FS126RC
FS127
FS146
FS146RC
FS147
*Load Type:
A-Incandescent & Resistive
B-Incandescent, Resistive & Inductive
Add the suffix “-##” to any part number to
indicate the custom flash rate.
Maximum Load Rating . . . . . . . . . . . . Fullwave: 1A steady state
Halfwave: 2A steady state
Inrush . . . . . . . . . . . . . . . . . . . . . . . . . . . 10A
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . Removable mounting bracket, use one #8 (M4 x 0.7) screw
Connection/Wires . . . . . . . . . . . . . . . . 18 AWG (0.82mm2) wires 6 in. (15.2cm)
Dimensions . . . . . . . . . . . . . . . . . . . . . . 1.5 x 0.94 in. (38.1 x 23.9 mm)
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated
Environmental
Operating / Storage Temperature . . -20° to 60°C / -40° to 85°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . 95% relative, non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 1.1 oz (31 g)
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Flashers
FS100 / FS200 Series
The FS100 Series (medium amp) may be used to
control inductive, incandescent, or resistive loads.
Input voltages of 24, 120, or 230VAC are available.
Factory fixed flash rate of 90 FPM or may be
ordered with a fixed, custom flash rate ranging
from 10 to 300 FPM. Encapsulation provides
protection against shock, vibration, and humidity.
This group of solid-state flashers has proven
reliability with years of use throughout the world.
Operation
Upon application of input voltage, the T2 OFF time
begins. At the end of the OFF time, the T1 ON time begins
and the load energizes. At the end of T1, T2 begins and
the load de-energizes. This cycle repeats until input
voltage is removed.
Reset: Removing input voltage resets the output and the
sequence to T2 .
Order Table:
Input Voltage
Rating
Part Number
24VAC
3A
FS143
120VAC
3A
FS152
230VAC
3A
FS162
Add the suffix “-##” to any part number to
indicate the custom flash rate.
For more information see:
Appendix A, page 164 for Flasher (OFF First) function.
Appendix B, page, 165, Figure 1 for dimensional drawing.
Appendix C, page168, Figure 3 for connection diagram.
Specifications
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . . . . .
Flash Rate . . . . . . . . . . . . . . . . . . . . . . . . .
Custom Flash Rates . . . . . . . . . . . . . . . . .
ON/OFF Ratio . . . . . . . . . . . . . . . . . . . . .
Input
Voltage/Frequency . . . . . . . . . . . . . . . . .
Output
Load Type . . . . . . . . . . . . . . . . . . . . . . . . .
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OFF/ON solid-state flasher (continuous duty)
Fixed at 90 FPM ±10%
10 - 300 FPM ±10%
≅ 50%
24, 120, or 230VAC ±15%/50/60 Hz
Inductive, resistive, or incandescent
Fullwave AC, solid state, SPST
Operation
Upon application of input voltage, the T2 OFF time begins.
At the end of the OFF time, the T1 ON time begins and
the load energizes. At the end of T1, T2 begins and the
load de-energizes. This cycle repeats until input voltage
is removed.
Reset: Removing input voltage resets the output and the
sequence to T2 .
Input Voltage
12VDC ±20%
24VDC ±20%
36VDC ±20%
48VDC ±15%
110VDC ±15%
Specifications
For more information see:
Appendix A, page 164 for Flasher (OFF First) function.
Appendix B, page, 165, Figure 1 for dimensional drawing.
Appendix C, page 168, Figure 4 for connection diagram.
Rating
3A
3A
1A
0.75A
0.25A
Part Number
FS219
FS224
FS236
FS248
FS290
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . .OFF/ON solid-state flasher (continuous duty)
Flash Rate . . . . . . . . . . . . . . . . . . . . . . . . . . .Fixed at 90 FPM ±10%
Custom Flash Rate . . . . . . . . . . . . . . . . . . . .10 - 180 FPM
ON/OFF Ratio . . . . . . . . . . . . . . . . . . . . . . .≅ 50%
Input
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12, 24, 36, 48, or 110VDC
Output
Load Type . . . . . . . . . . . . . . . . . . . . . . . . . . .Inductive, resistive, or incandescent
Maximum Load Rating . . . . . . . . . . . . . . . .0.25 - 3A steady state
OFF State Leakage Current
12 & 24VDC . . . . . . . . . .≤ 250 µA
www.ssac.com • 800-843-8848 • fax: 605-348-5685
• Fixed at 90 FPM
• Custom flash rate 10 - 300 FPM
• Switches inrush currents up to 30A
• 24, 120, or 230VAC input voltages
• Totally solid state & encapsulated
Approvals:
Auxiliary Products:
• Female quick connect:
P/N: P1015-64 (AWG 14/16)
• Quick connect to screw adaptor:
P/N: P1015-18
• Mounting bracket: P/N: P1023-6
• DIN rail: P/N: C103PM (Al)
• DIN rail adaptor: P/N: P1023-20
Available Models:
FS152-60
FS143
FS162
FS152
FS162-30
FS152-30
FS152-50
If desired part number is not listed, please call us to
see if it is technically possible to build .
Maximum Load Rating . . . . . . . . . . . . . .
Inrush . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . .
Termination . . . . . . . . . . . . . . . . . . . . . . . .
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environmental
Operating / Storage Temperature . . . . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The FS200 Series may be used to control inductive,
incandescent, or resistive loads. Input voltages of
12, 24, 36, 48, or 110VDC are available. Factory
fixed flash rate of 90 FPM or may be ordered with a
fixed custom flash rate ranging from 10 to 180 FPM.
Encapsulation provides protection against shock,
vibration, and humidity. Uniform performance,
high inrush current capability, and low RFI, make
this series ideal for general industrial applications.
Order Table:
Features:
3A steady state
10 times steady state current
Surface mount with one #10 (M5 x 0.8) screw
2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
0.25 in. (6 .35 mm) male quick connect terminals
Encapsulated
-20° to 60°C / -40° to 85°C
≅ 2.2 oz (62 g)
Features:
• Fixed at 90 FPM
• Custom flash rate 10 - 180 FPM
• 3A, SPST output contact
• 12 to 110VDC input voltages in 5 ranges
• Totally solid state & encapsulated
• 0.25 in. (6.35 mm) male quick connects
Auxiliary Products:
• Female quick connect:
P/N: P1015-64 (AWG 14/16)
• Quick connect to screw adaptor:
P/N: P1015-18
• Mounting bracket: P/N: P1023-6
• DIN rail: P/N: C103PM (Al)
• DIN rail adaptor: P/N: P1023-20
Available Models:
FS224
If desired part number is not listed, please call us to
see if it is technically possible to build .
Inrush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 times steady state current
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount with one #10 (M5 x 0.8) screw
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . . .0.25 in. (6.35 mm) male quick connect terminals
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated
Environmental
Operating / Storage Temperature . . . . . . .-20° to 60°C / -40° to 85°C
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 2.2 oz (62 g)
105
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Flashers
FS300 / FS400 Series
The FS300 Series of solid-state flashers were
specifically designed to operate lamp loads. Their
two-terminal series connection feature makes
installation easy. The high immunity to line
noise and transients makes the FS300 Series ideal
for moving vehicle applications. All solid-state
construction means reliability and long life. The
FS300 Series offers a factory fixed flash rate of 75
FPM or may be ordered with a fixed, custom flash
rate ranging from 60 to 150 FPM.
Order Table:
Input
12VDC ±20%
24VDC ±20%
36VDC ±20%
48VDC ±15%
72VDC ±15%
110VDC ±15%
Operation
Upon application of input voltage, the T2 OFF time
begins. At the end of the OFF time, the T1 ON time begins
and the load energizes. At the end of T1, T2 begins and
the load de-energizes. This cycle repeats until input
voltage is removed.
Reset: Removing input voltage resets the output and the
sequence to T2 .
Maximum
Current Load
Specifications
2.5A
1.5A
1A
0.75A
0.5A
0.25A
FS312
FS324
FS336
FS348
FS372
FS390
Appendix B, page 165, Figure 1 for dimensional drawing.
Appendix C, page 168, Figure 5 for connection diagram.
Operation
Upon application of input voltage, the output energizes
and the ON time begins. At the end of the ON time, the
output de-energizes and the OFF time begins. At the end
of the OFF time, the output energizes and the cycle repeats
as long as input voltage is applied.
Reset: Removing input voltage resets the output and the
flash sequence.
120 to 240VAC
24VAC
Specifications
• Female quick connect:
P/N: P1015-64 (AWG 14/16)
• Quick connect to screw adaptor:
P/N: P1015-18
• Mounting bracket: P/N: P1023-6
• DIN rail: P/N: C103PM (Al)
• DIN rail adaptor: P/N: P1023-20
Available Models:
FS312
FS324
FS336
FS390
Features:
• Low leakage for LED lamps
• Fixed flash rate at 75 FPM
• Custom flash rate 45 - 150 FPM
• 0.5 or 1A, solid-state output
• 24V to 240VAC in 2 ranges
• Small size: 1.5 x 0.94 in. (38 x 23.9 mm)
Approvals:
Available Models:
FS491
For more information see:
Appendix A, page 164 for Flasher (ON First) function.
Appendix B, page 165, Figure 12 for dimensional drawing.
Appendix C, page 168, Figure 6 for connection diagram.
Output Rating
0.5A
1A
Part Number
FS491
FS421
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ON/OFF solid-state flasher (continuous duty)
Flash Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fixed at 75 FPM ±20%
Custom Flash Rates . . . . . . . . . . . . . . . . . . . . . . .45 - 150 FPM ±20%
ON/OFF Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 50%
Input
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24, or 120 - 240VAC
Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .± 15%
AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . .50/60Hz
Output
Load Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .LED or resistive
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bridge Rectifier & FET
Maximum Load Rating
120VAC to 240VAC . . . . . . . . . . .0.5A steady state; 5A inrush
24VAC . . . . . . . . . . . .1A steady state; 10A inrush
106
Auxiliary Products:
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount with one #10 (M5 x 0.8) screw
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . .2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . .0.25 in. (6.35 mm) male quick connect terminals
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated
Environmental
Operating / Storage Temperature . . . . . .-20° to 60°C / -40° to 85°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . .95% relative, non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 2.2 oz (62 g)
The FS400 Series is a low leakage AC flasher
designed to control LED, or resistive loads. This
series offers a solid-state output and may be
ordered with an input voltage of 24V to 240VAC,
in two ranges. It offers a factory fixed flash rate of
75 FPM or may be ordered with a fixed, custom
flash rate ranging from 45 to 150 FPM. The FS400
is the perfect solution for LED lamp flashing.
Input Voltage
• All solid state – no moving parts or contacts
• High surge capability – designed to operate
incandescent lamp loads
• High noise & transient protection
• Two-terminal series connection
• Encapsulated – protects against shock,
vibration, & humidity
For more information see:
Part Number Appendix A, page 164 for Flasher (OFF First) function.
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .OFF/ON recycling solid-state flasher (continuous duty)
Flash Rate . . . . . . . . . . . . . . . . . . . . . . . . . .Fixed at 75 FPM ±10%
Custom Flash Rates . . . . . . . . . . . . . . . . . .60 - 150 FPM
ON/OFF Ratio . . . . . . . . . . . . . . . . . . . . . .≅ 50%
Input
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12, 24, 36, 48, 72, & 110VDC
Output
Load Type . . . . . . . . . . . . . . . . . . . . . . . . . .Incandescent or resistive
Maximum Load Rating . . . . . . . . . . . . . . .0.25 - 2.5A steady state
Inrush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 times steady state current
Order Table:
Features:
Max. Load Leakage Current . . . . . . . . . . . . . . . .250µA
Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2V typical
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount with one #8 (M4 x 0.7) screw
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5 x 0.94 in. (38.1 x 23.9 mm)
Protection
Surge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IEEE C62.41 - 1991 Level A
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated
Environmental
Operating / Storage Temperature . . . . . . . . . . .-20° to 60°C / -40° to 85°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95% relative, non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 1.1 oz (31 g)
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Flashers
FS500 / AF Series
The FS500 Series flash rate is adjustable from 10 to
100 FPM. A locknut is provided to hold selected
flash rate. The long-life electronic circuit combined
with a quality electromechanical relay provides
flexibility and reliability in most applications.
Operation
Upon application of input voltage, the output relay is
energized and the ON time begins. At the end of the ON
time, the output relay de-energizes and the OFF time
begins. At the end of the OFF time, the output is energized
and the cycle repeats as long as input voltage is applied.
Reset: Removing input voltage resets the output and
the sequence.
Order Table:
Input Voltage
12VDC
24VAC/DC
120VAC/DC
230VAC
Part Number
Specifications
FS512
FS524
FS590
FS599
For more information see:
Appendix A, page 164 for Flasher (ON First-DPDT)
function.
Appendix B, page 165, Figure 9 for dimensional drawing.
Appendix C, page 168, Figure 8 for connection diagram.
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .ON/OFF recycling flasher with adjustable flash rate
Flash Rate . . . . . . . . . . . . . . . . . . . . . . . . . . .Adjustable from 10 - 100 operations per minute
(guaranteed range)
ON/OFF Ratio . . . . . . . . . . . . . . . . . . . . . . .≅ 50%
Input
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . .12VDC, 24VAC/DC, 120VAC/DC, 230VAC
Tolerance
12VDC & 24VDC/AC . . . .-15% - 20%
120 - 230VAC/DC . . . .-20% - 10%
AC Line Frequency . . . . . . . . . . . . . . . . . . .50/60Hz
Output
Load Type . . . . . . . . . . . . . . . . . . . . . . . . . . .Electromechanical relay
Order Table:
AF
X
Input Voltage
─1 - 24VAC
─2 - 120VAC
─3 - 230VAC
X
Output Rating
─1 - 6A
─2 - 10A
─3 - 20A
Features:
• Solid-state circuitry - relay output
• Industrial standard octal plug-in
• Adjustable flash rate 10 - 100 FPM
• 10A, DPDT output contacts
Approvals:
(some models)
Auxiliary Products:
• Panel mount kit: P/N: BZ1
• Octal 8-pin socket: P/N: NDS-8
• Hold-down clips (sold in pairs):
P/N: PSC8 (NDS-8)
• DIN rail: P/N: C103PM (Al)
Available Models:
FS512
FS524
FS590
If desired part number is not listed, please call us to
see if it is technically possible to build .
Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DPDT
Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10A resistive @ 120/240VAC & 28VDC;
1/3 hp @ 120/ 240VAC
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . .Plug-in socket
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .3.62 x 2.39 x 1.78 in. (91.6 x 60.7 x 45.2 mm)
Termination . . . . . . . . . . . . . . . . . . . . . . . . . .Octal 8-pin plug-in
Protection
Isolation Voltage . . . . . . . . . . . . . . . . . . . . . .> 1500V RMS input to output
Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DC units are reverse polarity protected
Environmental
Operating / Storage Temperature . . . . . . .-20° to 60°C / -30° to 85°C
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 5.8 oz (164 g)
The AF Series offers a high inrush capacity of up
to 200A. These devices exceed mechanical type
relays in both performance and lifespan. The AF
Series is constructed with no moving parts to arc,
wear, and eventually fail; 100 million operations
are typical. Circuitry is encapsulated to provide
protection against vibration and moisture, making
the AF Series ideal for outdoor applications.
Features:
Operation
Upon application of input voltage T1 begins, Load 1 is
ON and Load 2 is OFF. At the end of T1, T2 begins and
Load 2 is now ON and Load 1 is OFF. At the end of T2,
T1 repeats and this sequence continues until input voltage
is removed. The duration of T1 and T2 is approximately
equal .
Reset: Removing input voltage resets the flasher.
Auxiliary Products:
For more information see:
Appendix A, page 164 for Flasher (Alternating) function.
Appendix B, page 166, Figure 13 for dimensional drawing.
Appendix C, page 168, Figure 7 for connection diagram.
X
FlashRate(flashespermin.)
─1 - 10
─2 - 30
─3 - 60
─4 - 90
─5 - 120
─6 - 140
─Blank - Custom Flash Rate
• Alternately flashes two high current loads
• High surge capacity - up to 200A
• Small size - 2 x 2 x 1.30 in.
(50.8 x 50.8 x 33 mm)
• Totally solid state & encapsulated
• Female quick connect:
P/N: P1015-13 (AWG 10/12)
P/N: P1015-64 (AWG 14/16)
P/N: P1015-14 (AWG 18/22)
• Quick connect to screw adaptor:
P/N: P1015-18
Available Models:
AF213
AF223
AF232
AF233
If desired part number is not listed, please call us to
see if it is technically possible to build .
Specifications
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Alternating solid-state flasher rated (continuous duty)
Flash Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . .Factory fixed at 10, 30, 60, 90, 120, or 140 flashes
per min. ±10%.
Custom Flash Rate . . . . . . . . . . . . . . . . . . . .10 - 140 FPM
Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 50%
Input
Input Voltage/Frequency . . . . . . . . . . . . . .24, 120, or 230VAC ±15% / 50/60Hz
Output
Load Type . . . . . . . . . . . . . . . . . . . . . . . . . . . .Incandescent or resistive
Maximum Load Rating . . . . . . . . . . . . . . . . .6, 10, & 20A steady state
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Inrush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 times steady state current
Mechanical
Mounting * . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount with one #10 (M5 x 0.8) screw
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .2 x 2 x 1.30 in. (50.8 x 50.8 x 33 mm)
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated
Environmental
Operating / Storage Temperature . . . . . . . .-20° to 60°C / -40° to 85°C
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95% relative, non-condensing
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 2.9 oz (82 g)
*Must be bolted to metal surface using the included heat sink compound. The maxim
mounting surface temperature is 90°C.
107
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Flasher (Chaser)
SC3/SC4 Series
The SC3/SC4 Series are solid-state 3 or 4 channel,
chasers designed for sequential three or four
circuit flashing of incandescent lamp loads. Unlike
electromechanical chasers, there are no contacts to
arc, wear, and eventually fail. Fixed or adjustable
rates of 30 to 300 operations per minute.
Operation
Sequential 3 or 4 circuit flashing of incandescent loads
with equal time delays for each load. Upon application
of input voltage, Load 1 is energized. At the end of the
time delay, Load 1 de-energizes and Load 2 energizes.
At the end of the time delay, Load 2 de-energizes and
Load 3 energizes. This cycle continues until input voltage
is removed.
Reset: Removing input voltage resets the unit and cycle.
For more information see:
Appendix A, page 164 for Flasher (Chasing) function.
Appendix B, page 166, Figure 14 for dimensional drawing.
Appendix C, page 168, Figure 9 for connection diagram.
Features:
• Sequential 3 or 4 circuit flashing of
incandescent loads
• Fixed or adjustable at 30 - 300FPM
• 1A steady state output
• 24, 120, or 230VAC input voltage
• Totally solid state - encapsulated
Approvals:
Auxiliary Products:
• Quick connect to screw adaptor:
P/N: P1015-18
• Female quick connect:
P/N: P1015-13 (AWG 10/12)
P/N: P1015-64 (AWG 14/16)
P/N: P1015-14 (AWG 18/22)
Available Models:
SC3120F30
If desired part number is not listed, please call us to
see if it is technically possible to build .
Order Table:
SC3 (3 outputs)
SC4 (4 outputs)
X
Input Voltage
─24 - 24VAC
─120 - 120VAC
─230 - 230VAC
X
Rate
─A - Adjustable (30 - 300)
─F - Fixed*
*If Fixed is selected, insert
(30 - 300) operations per
minute .
Specifications
Technical Data
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sequential 3 or 4 circuit flashing of incandescent
lamp loads. Fixed or adjustable rates.
Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjustable: 30 - 300 operations per minute
Fixed: 30 - 300 operations per minute (±10%)
Input
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 120, or 230VAC ±15%
AC Line Frequency . . . . . . . . . . . . . . . . . . . . 50/60 Hz
Output
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solid state
Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1A steady state per output
Mechanical
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surface mount with two #6 (M3.5 x 0.6) screws
Termination . . . . . . . . . . . . . . . . . . . . . . . . . . 0.25 in. (6.35 mm) male quick connect terminals
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 x 2.5 x 1.22 in. (88.9 x 63.5 x 31 mm)
108
Protection
Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dielectric Breakdown . . . . . . . . . . . . . . . . . .
Insulation Resistance . . . . . . . . . . . . . . . . . . .
Environmental
Operating / Storage Temperature . . . . . . .
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Encapsulated
≥ 2000V RMS terminals to mounting surface
≥ 100 MΩ
-20° to 60°C / -40° to 85°C
95% relative, non-condensing
≅ 5.4 oz (153 g)
www.ssac.com • 800-843-8848 • fax: 605-348-5685