Viking Range CRVDD345R, RVDD345R, CRVDD336R, RVDD336R, CRVDD330R, RVDD330R Installation guide
Add to my manuals24 Pages
advertisement
▼
Scroll to page 2
of 24
VIKING RANGE, LLC Downdraft Ventilators MODEL WIDTHBLOWER (purchase separately) RVDD330R / CRVDD330R 30" w/ remote control VIDV500 Interior or VEDV900 Exterior RVDD336R / CRVDD336R 36" w/ remote control VIDV500 Interior or VEDV900 Exterior RVDD345R / CRVDD345R 45" w/ remote control VIDV500 Interior, VEDV900 Exterior, or VEDV1200 Exterior WARNING - To reduce the risk of burns or ignition of clothing by reaching across burners, the downdraft remote control MUST be mounted in the countertop - at least 4" from the burners. See "INSTALL COOKTOP" section on page 8. READ AND SAVE THESE INSTRUCTIONS ! INTENDED FOR DOMESTIC COOKING ONLY ! WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce the risk of fire, use only metal ductwork. 8. Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the cook top or range top should be 4 inches. 9. Loose-fitting or hanging clothing should never be worn when operating this appliance. They may be ignited by burners/ elements on cooktop. 10.Children should not be left alone or unattended in the area where this appliance is in use. 11. This unit must be grounded. 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher, and you already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. a Based on “Kitchen Firesafety Tips” published by NFPA. CAUTION ! 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Clean filters and grease-laden surfaces frequently. 4. Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician. 5. Please read specification label on product for further information and requirements. TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when cooking flaming foods. c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. d) Use proper pan size. Always use cookware appropriate for the size of the surface element. INSTALLER: Save this manual for Electrical Inspector and Homeowner to use. HOMEOWNER: Use and Care Information on Page 11. 1 VIKING RANGE, LLC Downdraft Ventilators PLANNING Interior Blower Installation This downdraft blower system is designed to be used to exhaust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, peninsula, or conventional wall locations. This unit can be easily installed following these basic steps: • Cut out the countertop opening. • Connect the ductwork and electrical. • Install the cooktop. Note: the high level of air flow of this appliance may effect the gas flame on some types of gas cooktops. This is NORMAL and will cause no harm, but can be corrected by lowering the speed of the blower. This downdraft blower system is designed to be used to exhaust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, peninsula, or conventional wall locations. TYPICAL INSTALLATION COUNTER TOP CHIMNEY TOP COOK TOP AIR VENT GEAR MOTOR COVER This unit can be easily installed following these basic steps: BLOWER BOX • Cut out the countertop opening. 120 VAC GROUNDED OUTLET • Mount the unit in the cabinet. • Install the Model VIDV500 Interior Blower Exterior Blower Installation • Mount the unit in the cabinet. • Install 10" round discharge plate 3-1/4" X 10" DUCT CONNECTOR • Install Model VEDV900 or VEDV1200 (DIPR151RSS only) External Blower ELECTRICAL SPECIFICATIONS • Connect the ductwork and electrical. 120 VAC • 60 Hz • 4.0 A TYPICAL INSTALLATION COUNTER TOP CHIMNEY TOP COOK TOP GEARMOTOR COVER AIR VENT 10" ROUND DISCHARGE PLATE 120 VAC GROUNDED OUTLET 10" ROUND DUCTWORK ELECTRICAL SPECIFICATIONS 120 VAC • 60 Hz • 6.0 A (max.) • Install the cooktop. Note: the high level of air flow of this appliance may effect the gas flame on some types of gas cooktops. This is NORMAL and will cause no harm, but can be corrected by lowering the speed of the blower. TAKE MEASUREMENTS All Units 1. Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. The Model RVDD330R / CRVDD330R will fit in most 30" wide cabinets, the Model RVDD336R / CRVDD336R will fit in most 36" wide cabinets, and the Model RVDD345R / CRVDD345R will fit most 45" wide cabinets. However, it is recommended that oversized cabinets be used for easier installation. 2. Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight. Pay special attention to the areas of potential interference highlighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough flat countertop for a proper installation. Note that 2" of flat countertop is required behind cooktop and that 1-3/4" is necessary between the back edge of the cooktop and the inside of cabinet back. 2 VIKING RANGE, LLC Downdraft Ventilators TAKE MEASUREMENTS (CONTINUED) Interior Blower Installation Exterior Blower Installation SIDE VIEW OF DOWNDRAFT WITH VIDV500 INTERIOR BLOWER SIDE VIEW OF DOWNDRAFT WITH 10" ROUND ELBOW (for connection to VEDV900 or VEDV1200 (DIPR150RSS only)) VIDV500 INTERIOR BLOWER PLAN THE DUCTWORK Interior Blower Installation 1. The interior downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to 6" round). Three different discharge directions are available with side-toside adjustment for accurate alignment of ductwork. Exterior Blower Installation LEFT DISCHARGE 1. The exterior downdraft blower system is designed for use with 10" round ductwork. 2. For best performance: Plan ducting which has the shortest length of ductwork and a minimum number of elbows. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. 2. For best performance: RIGHT Choose the ducting DISCHARGE option which allows the shortest length DOWN DISCHARGE of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. 6" ROUND ELBOW EQUALS 6 FT. OF STRAIGHT DUCT 3-1/4" X 10" TO 6" RD. TRANSITION EQUALS 2 FT. OF STRAIGHT DUCT 10" ROUND DISCHARGE PLATE 10" ROUND ELBOW 3-1/4" X 10" 90O ELBOW 3. The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The illustration, above, shows equivalent feet of a 10" round elbow. The number of feet of straight duct plus the equivalent feet of elbows to be used should equal 40 feet or less. EQUALS 8 FT. OF STRAIGHT DUCT NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation. 3. The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart, above, shows equivalent feet of elbows and transitions. The number of feet of straight duct plus the equivalent feet of transitions and/or elbows to be used should equal 40 feet or less. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation. EQUALS 6 FT. OF STRAIGHT DUCT 3 VIKING RANGE, LLC Downdraft Ventilators PLAN THE CABINET CUTOUTS Interior Blower Installation Exterior Blower Installation LEFT SIDE DISCHARGE LEFT SIDE DISCHARGE 241 /8" 19¾ CENTER LINE OF COUNTER CUTOUT CENTER LINES OF DUCT CUTOUT 10¼" x 3½" CUTOUT (TYP.) CENTER LINE OF COUNTER CUTOUT CENTER LINES OF DUCT CUTOUT 10" ROUND CUTOUT (TYP.) ! 5½" " CAUTION: BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical wiring, or plumbing. RIGHT SIDE DISCHARGE 10¼ " RIGHT SIDE DISCHARGE 16 3/8" " 19¾ CENTER LINES OF DUCT CUTOUT CENTER LINE OF COUNTER CUTOUT CENTER LINES OF DUCT CUTOUT CENTER LINE OF COUNTER CUTOUT 10¼" x 3½" CUTOUT (TYP.) 10" ROUND CUTOUT (TYP.) " 5½" 10¼ BOTTOM DISCHARGE BOTTOM DISCHARGE " 3½ CENTER LINE OF COUNTER CUTOUT o 1" t " 8" CENTER LINE OF DUCT CUTOUT 10" ROUND DIA. CUTOUT (TYP.) 5½" 10¼" x 3½" CUTOUT (TYP.) 2¾ CENTER LINE OF COUNTER CUTOUT " 10¼ ¼" 4 CENTER LINE OF DUCT CUTOUT 6 CENTER LINE OF DUCT CUTOUT (can be located within this area) VIKING RANGE, LLC Downdraft Ventilators PLAN THE WIRING Interior Blower Installation Exterior Blower Installation 1. The Interior Downdraft Blower system draws 4 AMPS and requires a 120 VAC, 60 Hz circuit. 1. The Exterior Downdraft Blower system draws 6 AMPS and requires a 120 VAC, 60 Hz circuit. 2. The downdraft has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach. 2. The downdraft has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach. IMPORTANT - LOCATION OF ELECTRICAL OUTLET: If Model RVDD330R / CRVDD330R is being installed in a 30" wide cabinet... or Model RVDD336R / CRVDD336R is being installed in a 36" wide cabinet... or Model RVDD345R / CRVDD345R is being installed in a 45" wide cabinet... ...the outlet cannot be located on the back wall of cabinet. In these cases, the width of the downdraft covers nearly the entire width of the back wall of the cabinet. So you must either: • mount the electrical box to a side wall or cabinet floor - at least 12 inches from the back wall. • mount the electrical box to a wall stud behind the cabinet - where it will not be covered by the downdraft Then provide a clearance hole in the back wall of the cabinet. IMPORTANT - LOCATION OF ELECTRICAL OUTLET: If Model RVDD330R / CRVDD330R is being installed in a 30" wide cabinet... or Model RVDD336R / CRVDD336R is being installed in a 36" wide cabinet... or Model RVDD345R / CRVDD345R is being installed in a 45" wide cabinet... ...the outlet cannot be located on the back wall of cabinet. In these cases, the width of the downdraft covers nearly the entire width of the back wall of the cabinet. So you must either: • mount the electrical box to a side wall or cabinet floor - at least 12 inches from the back wall. • mount the electrical box to a wall stud behind the cabinet - where it will not be covered by the downdraft Then provide a clearance hole in the back wall of the cabinet. PLEASE NOTE: External blowers must be hard-wired using locallysupplied wire and connected to the downdraft plug (included). PREPARE THE DOWNDRAFT Interior Blower Installation 3¼" X 10" DISCHARGE The downdraft is shipped without a blower. Purchase a Model VIDV500 Interior Blower and mount it to the downdraft as follows: NUTS BLOWER 1. Place the downdraft on its back on a table of flat work surface. 2. Remove the 4 nuts and 2 clamp channels. 3.Remove 2 screws and the gear motor cover. CLAMP CHANNELS 4. Carefully position the blower under the bottom flange of the downdraft with the 3¼" x 10" discharge pointed in the desired direction. SCREWS 5.Connect motor plug. 6. Replace the gear motor cover and 2 sheet metal screws. GEARMOTOR COVER COVER PLATE MOTOR PLUG ADDITIONAL SCREWS 7. Replace the 2 clamp channels and start the 4 nuts, do not tighten. 8. Slide blower left of right to desired position. Use cover plate (supplied) to close up any open space. 9. Tighten 4 nuts to secure top of blower. Use additional screws (supplied) through bottom flange to secure bottom in blower. 5 BOTTOM FLANGE VIKING RANGE, LLC Downdraft Ventilators PREPARE THE DOWNDRAFT Exterior Blower Installation NUTS The downdraft is shipped without a blower. Purchase a Model VEDV900 Exterior Blower and mount the 10" discharge plate to the downdraft as follows: 10" ROUND DISCHARGE PLATE MOTOR PLUG CLAMP CHANNELS 1. Place the downdraft on its back on a table of flat work surface. 2. Remove the 4 nuts and 2 clamp channels. SCREWS 3.Remove 2 screws and the gear motor cover. 4. Carefully position the10" discharge plate under the bottom flange of the downdraft. COVER PLATE GEARMOTOR COVER 5.Connect motor plug. ADDITIONAL SCREWS 6. Replace the gear motor cover and 2 sheet metal screws. 7. Replace the 2 clamp channels and start the 4 nuts, do not tighten. 8. Slide blower left of right to desired position. Use cover plate (supplied) to close up any open space. 9. Tighten 4 nuts to secure top of blower. Use additional screws (supplied) through bottom flange to secure bottom of discharge plate. BOTTOM FLANGE CUT COUNTERTOP OPENING All Units 1. Measure and cut the countertop opening for your width of cooktop and downdraft. 30" RVGC3305B 36" RVGC3365B 45" RVEC3456B Cooktop Width & Model 30" RVEC3305B 36" RVEC3365B 45" CRVEC3456B 30" CRVGC3305B 36" CRVGC3365B 30" CRVEC3305B 36" CRVEC3365B For use with Downdraft Models RVDD330R RVDD336R RVDD345R CRVDD330R CRVDD336RCRVDD345R Cutout Dimensions A 29-1/8" B20-5/8" C27" D2-1/4" E1-1/16" F1-1/16" 34-7/8" 20-5/8" 33" 2-1/4" 15/16" 15/16" 42-7/8" 20-5/8" 42" 2-1/4" 7/16" 7/16" F E C D B A 6 BLOWER MODEL DIMENSIONS VIDV500 18.25" x 18.214" x 7.569" VEDV900 28.25" x 24.75" x 7.16" VEDV1200 22" x 30.828" x 12.724" VIKING RANGE, LLC Downdraft Ventilators MOUNT THE UNIT MOUNTING SCREWS All Units LEVELING BRACKET FLANGE FACING OUT 1. Set downdraft into opening. Extend leveling brackets to floor of cabinet so downdraft sits straight. (Note: Leveling brackets can be removed and re-attached in other positions. Bottom flange may have to face inward in tight cabinet installations.) 2. Secure the downdraft to the countertop as follows: Hold the downdraft against the back of countertop cut-out and tightening the two mounting screws (one on each end of unit) on underside of countertop. Use a wood shim between screw and underside of granite countertops. LEVELING BRACKET FLANGE FACING IN 3.Screw leveling brackets to bottom of cabinet. Tighten screws holding leveling bracket to unit on each side. INSTALL DUCTWORK Interior Blower Installation Exterior Blower Installation ! CAUTION: BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical wiring, or plumbing. BLOWER COLLAR SCREWS 3-1/4" X 10" TO 6" RD. TRANSITION ELBOW 6" RD. ELBOW & DUCTWORK 10" ROUND DUCT ELBOW 1. Cut hole in cabinet as well as holes in wall or floor as necessary. 1. Cut hole in cabinet as well as holes in wall or floor as necessary. 2. Mount the roof or wall cap and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight. 2. Mount the exterior blower and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight. 3.Connect ductwork (and transition, if required) to downdraft. If necessary, LOOSEN nuts and screws that hold the blower in place, and slide blower left or right to meet ductwork. Retighten screws and nuts. 3. Connect ductwork to downdraft. If necessary, LOOSEN nuts and screws that hold remote blower adapter plate in place, and slide outlet assembly left or right to meet ductwork. Re-tighten screws and nuts. Note: A 3-1/4" x 10" collar is provided for installers who prefer to rivet the ductwork to the unit. This will allow blower to be removed and replaced easily in service situations without disturbing ductwork. 7 VIKING RANGE, LLC Downdraft Ventilators INSTALL ELECTRICAL WIRING Interior Blower Installation Exterior Blower Installation ! ! CAUTION: All electrical wiring should be done by a qualified person(s) in accordance with all applicable codes and standards. CAUTION: All electrical wiring should be done by a qualified person(s) in accordance with all applicable codes and standards. 1. Mount a standard wiring box, with 3-pronged receptacle, inside the cabinet. Make sure the downdraft's power cord can easily reach it. 1. Mount a standard wiring box, with 3-pronged grounded receptacle, inside the kitchen cabinet. Make sure the downdraft's power cord can easily reach it. 2. Run appropriate power cable into cabinet and connect it to receptacle. 2. Run appropriate power cabinet into cabinet and connect it to electrical box and receptacle. 3. Plug the downdraft's power cord into the outlet. Make sure that the power cord is routed away from the heat generated by the cooktop. 3. Exterior blower may not exceed 6.0 Amp rating. 4. Run 2-wire plus ground power cable from the remote blower to wiring box on 10" round discharge plate. 5. Connect downdraft wiring to power cable from remote blower. Wire black to black, white to white, and green to green or bare wire. 6. Replace wiring box cover. 7. Plug the downdraft's power cord into outlet. Make sure that the power cord is routed away from the heat generated by the cooktop. INSTALL COOKTOP All Units "R" MODEL DOWNDRAFT 1. Align the cooktop with the downdraft and fasten cooktop in place. Note: Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent is raised and lowered. There should be a gap of 1/32" - 1/16" between the back of the cooktop and the front of the downdraft cover. REMOTE CONTROL COUNTERTOP Note: The downdraft remote control must be mounted into the countertop, at least 4" from cook top or range top edge. 8 VIKING RANGE, LLC Downdraft Ventilators INSTALLATION OF REMOTE CONTROL SWITCH WARNING: To reduce the risk of burns or ignition of clothing by reaching across burners, the remote control must be mounted at least 4" from cook top or range top edge. 3. Remove the control from the plastic bag. Remove the paper from the adhesive back of the control, line the control up with the three holes and position the control so it is parallel with the front of the counter top. Press down firmly for 60 seconds. Keep in mind you do not want to place the control where it will be in the way for cooking, or where hot pans could be set, or hot liquids spilled on the control. 4. Remove the two nylon thumbnuts from the plastic bag and thread onto the two studs on the control from below the counter top. Hand tighten only. The thumbnuts just need to be snugged by hand. They are there to hold the control in place until the adhesive sets up. 1. Using the template below, lay out the 3-hole pattern on the counter top. Mark the centers of the three holes to be drilled. 5. Remove cable from the plastic bag and plug into back of control from below counter top. Route cable through cabinet to lower right hand corner of downdraft. Plug other end of cable into the downdraft unit. (Receptacle hole for cabinet is on the lower right hand side of the downdraft.) 2. Carefully drill the three holes through the counter top. Be careful not to damage or chip the counter top surface when drilling the holes. 6. Stuff excess cable out of the way and secure the cable so it is not damaged from items stored in the cabinet. TOP EDGE 1/4" DIA. HOLE 1/4" DIA. HOLE 1" DIA. HOLE CUT OUT ON DOTTED LINE 9 VIKING RANGE, LLC Downdraft Ventilators This page has been left blank intentionally. BACKSIDE OF REMOTE SWITCH TEMPLATE 10 VIKING RANGE, LLC Downdraft Ventilators OPERATION UP / DOWN����Raises and lowers vent. Turns blower ON when vent is UP and OFF when vent is DOWN. All Units DELAY�����������Allows blower to run for 10 min. after button is pressed. Delay is activated by holding down any speed control button until the LED indicator flashes. Blower will run for 10 min. - then shut OFF. VENT WILL NOT LOWER. You must press UP / DOWN to lower vent. When DELAY is activated, the speed level light will blink. REMOTE CONTROL FOR MODELS RVDD330R RVDD336R RVDD345R CRVDD330R CRVDD336R CRVDD345R BLOWER SPEEDS������Blower operates at 4 different speed levels. Press button ONCE to turn blower ON to desired speed. Press button AGAIN to turn blower OFF. FILTER LIGHT������������Comes ON after 30 hours of operation to remind you to clean filters. Press button to reset. USE AND CARE Always turn the downdraft blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clean the air after you turn the cooktop off.This will keep the whole kitchen cleaner and brighter. The activating switch is pressed and the air vent rises. All Units WARNING: Always disconnect electric power supply before cleaning and/or servicing unit. Wash the 2 aluminum/stainless steel grease filters in a mild detergent solution or a dishwasher. Remove them from the air vent by grasping the tab at the top of each filter. Servicing It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism. Cleaning Use a mild detergent suitable for painted surfaces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POWDERS. Vacuum blower to clean. Do not immerse blower in water. Disconnect power to the cooktop and remove it first. Reverse the steps under “MOUNT THE UNIT” to remove the downdraft from the cabinet. 11 BUILT-IN REAR DOWNDRAFT WARRANTY THREE YEAR FULL WARRANTY Built-in downdraft ventilators, all of their component parts and accessories, except as detailed below*, are warranted to be free from defective materials or workmanship in normal household use for a period of thirty-six (36) months from the date of original retail purchase. Viking Range, LLC, warrantor, agrees to repair or replace, at its option, any part which fails or is found to be defective during the warranty period. For the purpose of this warranty, normal household use shall not include use of this downdraft ventilator with a cooking unit that has a grill. The Viking warranty does not cover any additional ventilation products not provided by Viking used in conjunction with Viking downdrafts or ventilator kits. This includes, but is not limited to, such devices as booster fans or in-line blowers. Any malfunction caused to Viking ventilation products as a direct result of the use of such equipment is not covered under the Viking warranty. Painted and decorative items are warranted to free from defective materials or workmanship for a period of ninety (90) days from the date of original retail purchase. ANY DEFECTS MUST BE REPORTED TO THE SELLING DEALER WITHIN NINETY (90) DAYS FROM DATE OF ORIGINAL RETAIL PURCHASE. FIVE YEAR LIMITED WARRANTY Any ventilator motor which fails due to defective materials or workmanship in normal household use during the second through the fifth year from the date of original retail purchase will be repaired or replaced, free of charge for the part itself, with the owner paying all other costs, including labor. This warranty extends to the original purchaser of the product warranted hereunder and to each transferee owner of the product during the term of the warranty. This warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in the country where service is requested. Warranty labor shall be performed by an authorized Viking Range, LLC service agency or representative. Warranty shall not apply to damage resulting from abuse, accident, natural disaster, loss of electrical power to the product for any reason, alteration, outdoor use, improper installation, improper operation or repair or service to the product by anyone other than an authorized Viking Range, LLC service agency or representative. This warranty does not apply to commercial usage. Warrantor is not responsible for consequential or incidental damage whether arising out of breach of warranty, breach of contract, or otherwise. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Owner shall be responsible for proper installation, providing normal care and maintenance, providing proof of purchase upon request, and making the appliance reasonably accessible for service. If the product or one of its component parts contains a defect or malfunction during the warranty period, after a reasonable number of attempts by the warrantor to remedy the defects or malfunctions, the owner is entitled to either a refund or replacement of the product or its component part or parts. Replacement of a component part includes its free installation. Warrantor’s liability on any claim of any kind, with respect to the goods or services covered hereunder, shall in no case exceed the price of the goods or service or part there of which gives rise to the claim. WARRANTY SERVICE: Under the terms of this warranty, service must be performed by a factory authorized Viking Range, LLC service agent or representative. Service will be provided during normal business hours, and labor performed at overtime or premium rates shall not be covered by this warranty. To obtain warranty service, contact the dealer from whom the product was purchased, an authorized Viking Range, LLC service agent, or Viking Range, LLC. Provide model and serial number and date of original purchase. For the name of your nearest authorized Viking Range, LLC service agency, call the dealer from whom the product was purchased or Viking Range, LLC. IMPORTANT: Retain proof of original purchase to establish warranty period. The return of the Owner Registration Card is not a condition of warranty coverage. You, however, should return the Owner Registration Card so that Viking Range, LLC can contact you should any question of safety arise which could affect you. Any implied warranties of merchantability and fitness applicable to the above described ventilator motor are limited in duration to the period of coverage of the applicable express written limited warranties set forth above. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific rights, and you may also have other rights which may vary from jurisdiction to jurisdiction. VIKING RANGE, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 Specifications subject to change without notice. For more product information, call 1-888-845-4641, or visit the web site at vikingrange.com in the U.S. or brigade.ca in Canada. F20126 99044906C VIKING RANGE, LLC MODÈLE RVDD330R / CRVDD330R RVDD336R / CRVDD336R RVDD345R / CRVDD345R LIRE ET CONSERVER CES INSTRUCTIONS ! DESTINÉ À LA CUISINE DOMESTIQUE SEULEMENT ! AVERTISSEMENT AVERTISSEMENT ATTENTION ! VIKING RANGE, LLC INSTALLATION TYPE COMPTOIR SURFACE DE CUISSON COUVERCLE DU MOTEUR BOUCHE DE CHEMINÉE CONDUIT D’AÉRATION BOÎTIER DU VENTILATEUR PRISE 120 VCA AVEC MISE À LA TERRE RACCORD DE CONDUIT 8,3 cm X 25,4 cm (3-1/4 po X 10 po) 120 VCA • 60 Hz • 4,0 A TYPICAL INSTALLATION COMPTOIR SURFACE DE CUISSON COUVERCLE DU MOTEUR CONDUIT D’AÉRATION CONDUIT ROND DE 25,4 cm (10 po) PRISE 120 VCA AVEC MISE À LA TERRE PLAQUE D’ÉVACUATION DE 25,4 cm (10 po) SPÉCIFICATIONS ÉLECTRIQUES 120 VCA • 60 Hz • 6,0 A (max.) 44,5 mm (1¾ po) 50,8 mm (2 po) COMPTIOR SURFACE DE CUISSION VENTILATEUR ENCASTRÉS BOUCHE DE CHEMINÉE AVANT AU DOS L'INTERIEUR DE LA ARMOIRE PROFONDEUR 14 VIKING RANGE, LLC 5 cm (2 po) 2" 0,95 cm 1"po) (3/8 7 16 " 8,2 cm (3 po) 11/4 34" 19,5 cm 11 (7 11/16 po) VUE DE CÔTÉ DE LA HOTTE AVEC VENTILATEUR INTÉRIEUR VIDV500 9,25CM (3 5/8 po) 38" 12,7 cm (5 po) 5" VIDV500 VENTILATEUR 45,7 cm INTÉRIEUR INTERNAL (18 po) VIDV500 BLOWER 2" 1" 7 mm 4 po) (1/4 0,95 cm (3/8 po) 19,5 11 cm 8,2 cm (3 (7 11/16 16po) 1/4 po) 1 1" " 5,4 cm 2 (2 81/8 1 po) 5" 29 16(29 74,6 cm 5/16 po) FROM DU COMPTOIR COUNTERTOP AU DESSOUS DU TO BOÎTIER BOTTOM OF AIR BOX 7 " 34" 2 " 9,2 5cm (3 5/8 po) 38" 5 29 " 8,1 cm 3 (3 3/16 po) 3 16 " 10" ROUND COUDE ROND DE 25,4 cm ELBOW 18" 1" 7 mm 4 po) (1/4 5,4 1cm (2 1/8 8 po) 1 13 " 33,6 cm 4 (13 1/4 po) 4 cm (1 9/169 po) 1 16 " 74,6 cm 16 (29FROM 5/16 po) DU COMPTOIR COUNTERTOP AU DESSOUS DU TOBOÎTIER BOTTOM OF AIR BOX (10 po) 33,6 cm (13 1/4 1 13po)4 " SIDE VIEW VIPR DOWNDRAFT VENTILATORS ÉGALE UN CONDUIT DROIT DE ÉGALE UN CONDUIT 61 CM DROIT DE 183 CM (6 PI) (2 PI) COUDE ROND DE 25,4 cm (10 po) COUDE À 90° DE 8,3 cm X 25,4 cm (3-1/4 po X 10 po) ÉGALE UN CONDUIT DROIT DE 183 CM (6 PI) ÉGALE UN CONDUIT DROIT DE 244 CM (8 PI) PLAQUE D’ÉVACUATION DE 25,4 cm (10 po) 15 VIKING RANGE, LLC SORTIE À GAUCHE 61,2 41(/24 8" 1/8 p LIGNES DE CENTRE DU DÉCOUCENTER LINES PAGE POUR OF DUCT CONDUIT CUTOUT o) LIGNES DE CENTRE CENTER DU DÉCOULINES OF PAGE POUR DUCT CUTOUT CONDUIT 50 (19 ,129c¾ 3/4 m" po) c2m CENTER LIGNE DELINE CENTRE OF DUCOUNTER DÉCOUPAGE CUTOUT DU COMPTOIR 10¼" x 3½" TROU (TYP.) 8,26CUTOUT x 25,4 cm (3¼ x (TYP.) 10 po) TROU ROND 10" ROUND (TYP.) 25,4 cmCUTOUT (10 po) (TYP.) ! 14 c 5m½("5 1/ 2p o) SORTIE À DROITE LIGNE DE CENTRE CENTER LINE DU DÉCOUPAGE OF COUNTER DU COMPTOIR CUTOUT 26 c m 10(¼ 10 1 " / 4 po ) SORTIE À DROITE m 3,6 /8"c ) 14613/8 po 50,2 (16 LIGNELINE DE CENTER DU OFCENTRE COUNTER DÉCOUPAGE CUTOUT DU COMPTOIR cm ) " o 93¾/4 p (119 LIGNES DE CENTER CENTRE LINES OF DU DÉCOUDUCT PAGE POUR CUTOUT CONDUIT LIGNE DE CENTER LINE CENTRE DU OF COUNTER DÉCOUPAGE CUTOUT DU COMPTOIR 10¼" x(TYP.) 3½" TROU CUTOUT 8,26 x 25,4 cm (3¼(TYP.) x 10 po) /2 ½ (5"1 m5 14 c po) /4 10" 1 10(¼ m 26 c po) LIGNES DE CENTER CENTRE LINES OF DU DÉDUCT COUPAGE CUTOUT POUR CONDUIT 10" ROUND TROU CUTOUT ROND (TYP.) (TYP.) 25,4 cm (10 po) SORTIE VERS LE BAS SORTIE VERS LE BAS CENTER LINE LIGNE DE CENTRE COUNTER DU OF DÉCOUPAGE CUTOUT DU COMPTOIR o) à (1 p po) cm8" 21,"5to cm (8 20,3 LIGNE DE CENTRE CENTER LINE DU DÉCOUPAGE DU OF COUNTER COMPTOIR CUTOUT LIGNE DE CENTRE CENTER LINE DU DÉCOUOF DUCT CUTOUT PAGE POUR CONDUIT TROU (TYP.) 10¼" x 3½" 8,26 xCUTOUT 25,4 cm (3¼ x 10(TYP.) po) " ) cm o 154½ /2 p (5 1 16 o) /2 p (3 1 m ) " c 9 83,½ 4 po 2 3/ ( m c" LIGNES DE 72¾ CENTER TROU ROND (TYP.) 10" ROUND 25,4 DIA. cm (10 po) CUTOUT (TYP.) cm LIGNE DE CENTRE DU DÉ4 15,9 1¼ COUPAGE POUR CONDUIT 6 6 /o)" ( CENTER LINE p (peut être située dans cette OF DUCT CUTOUT partie) (can be located within this area) CENTRE LINE DU OFDÉCOUDUCT PAGE POUR CUTOUT CONDUIT " /4 po) 10(¼ 10 1 m 26 c VIKING RANGE, LLC PRÉPARATION DE LA HOTTE SORTIE DE 8,3 x 25,4 cm (3-1/4 x 10 po) ÉCROUS VENTILATEUR PROFILÉS VIS COUVERCLE DU MOTEUR PLAQUECOUVERCLE PRISE DU MOTEUR VIS SUPPLÉMENTAIRES BRIDE INFÉRIEURE 17 VIKING RANGE, LLC COUVERCLE DU MOTEUR ÉCROUS PLAQUE D’ÉVACUATION RONDE DE 25,4 cm (10 po) PROFILÉS VIS PLAQUE-COUVERCLE PRISE DU MOTEUR VIS SUPPLÉMENTAIRES BRIDE INFÉRIEURE 76.2 cm (30 po) RVGC3305B 76.2 cm (30 po) RVEC3305B 76.2 cm (30 po) CRVGC3305B 76.2 cm (30 po) CRVEC3305B 91.4 cm (36 po) RVGC3365B 114.3 cm (45 po) RVEC3456B 91.4 cm (36 po) RVEC3365B 114.3 cm (45 po) CRVEC3456B 91.4 cm (36 po) CRVGC3365B 91.4 cm (36 po) CRVEC3365B RVDD336R CRVDD336R RVDD345R CRVDD345R 88.6 cm (34-7/8 po) 52.4 cm (20-5/8 po) 83.8 cm (33 po) 5.7 cm (2-1/4 po) 2.4 cm (15/16 po) 2.4 cm (15/16 po) 108.9 cm (42-7/8 po) 52.4 cm (20-5/8 po) 106.7 cm (42 po) 5.7 cm (2-1/4 po) 1.1 cm (7/16 po) 1.1 cm (7/16 po) A B C D E F 73.9 cm (29-1/8 po) 52.4 cm (20-5/8 po) 68.6 cm (27 po) 5.7 cm (2-1/4 po) 2.7 cm (1-1/16 po) 2.7 cm (1-1/16 po) F E C D B A 18 MODÈLE DE VENTILATEUR DIMENSIONS VIDV500 46.4 cm x 46.3 cm x 19.2 cm (18.25 po) x (18.214 po) x (7.569 po) VEDV900 71.8 cm x 62.9 cm x 18.2 cm (28.25 po) x (24.75 po) x (7.16 po) VEDV1200 55.9 cm x 78.3 cm x 32.3 cm (22 po) x (30.828 po) x (12.724 po) VIKING RANGE, LLC INSTALLATION DE L’UNITÉ VIS DE MONTAGE BRIDE DE NIVELLEMENT – REBORD À L’EXTÉRIEUR BRIDE DE NIVELLEMENT – REBORD À L’INTÉRIEUR ! VENTILATEUR COLLET VIS COUDE COUDE ET CONDUIT DE 15,2 cm (6 po) ROND CONDUIT ROND DE 25,4 cm (10 po) COUDE VIKING RANGE, LLC ! ! INSTALLATION DE LA SURFACE DE CUISSON HOTTE MODÈLE "R" 0,8 (1/32 mm po) à 1,6 (1/16 mm po) 10 c (4 po m ) TÉLÉCOMMANDE COMPTOIR VIKING RANGE, LLC TOP BORD DUEDGE COMPTOIR TROU DE 7 1/4" DIA. mm (1/4 po) HOLE DIA. TROU DE 7 mm1/4" (1/4 DIA. po) DIA. HOLE TROU1"DE 25.4 mm DIA. (1HOLE po) DIA. CUT OUT ON LINE DÉCOUPER LEDOTTED POINTILLÉ 21 VIKING RANGE, LLC ARRIÈRE DU GABARIT DE LA TÉLÉCOMMANDE 22 VIKING RANGE, LLC TÉLÉCOMMANDE DES MODÈLES RVDD330R RVDD336R RVDD345R CRVDD330R CRVDD336R CRVDD345R Nettoyage 23 F20126 99044906C
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project