Ref. Nr. 152.939
ENGLISH
Congratulations to the purchase of this Beamz light effect. Please read this manual thoroughly prior to using the unit in
order to benefit fully from all features.
Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions
to avoid fire and/or electrical shock. Repairs must only be carried out by a qualified technician in order to avoid electrical
shock. Keep the manual for future reference.
- Prior to using the unit, please ask advice from a
specialist. When the unit is switched on for the first time,
some smell may occur. This is normal and will disappear
after a while.
- The unit contains voltage carrying parts. Therefore do
NOT open the housing.
- Do not place metal objects or pour liquids into the unit
This may cause electrical shock and malfunction.
- Do not place the unit near heat sources such as
radiators, etc. Do not place the unit on a vibrating
surface. Do not cover the ventilation holes.
- The unit is not suitable for continuous use.
- Be careful with the mains lead and do not damage it. A
faulty or damaged mains lead can cause electrical shock
and malfunction.
- When unplugging the unit from a mains outlet, always
pull the plug, never the lead.
- Do not plug or unplug the unit with wet hands.
- If the plug and/or the mains lead are damaged, they
need to be replaced by a qualified technician.
- If the unit is damaged to such an extent that internal
parts are visible, do NOT plug the unit into a mains outlet
and DO NOT switch the unit on. Contact your dealer. Do
NOT connect the unit to a rheostat or dimmer.
- To avoid fire and shock hazard, do not expose the unit to
rain and moisture.
- All repairs should be carried out by a qualified technician
only.
- Connect the unit to an earthed mains outlet
(220-240Vac/50Hz) protected by a 10-16A fuse.
- During a thunderstorm or if the unit will not be used for a
longer period of time, unplug it from the mains. The rule
is: Unplug it from the mains when not in use.
- If the unit has not been used for a longer period of time,
condensation may occur. Let the unit reach room
temperature before you switch it on. Never use the unit
in humid rooms or outdoors.
- During operation, the housing becomes very hot. Do not
touch it during operation and immediately after.
- To prevent accidents in companies, you must follow the
applicable guide lines and follow the instructions.
- Secure the unit with an extra safety chain if the unit is
ceiling mount. Use a truss system with clamps. Make
sure nobody stands in the mounting area. Mount the
effect at least 50cm away from inflammable material and
leave at least 1 meter space on every side to ensure
sufficient cooling.
- This unit contains high intensity LEDs. Do not look into
the LED light to prevent damage to your eyes.
- Do not repeatedly switch the fixture on and off. This
shortens the life time.
- Keep the unit out of the reach of children. Do not leave
the unit unattended.
- Do not use cleaning sprays to clean switches. The
residues of these sprays cause deposits of dust and
grease. In case of malfunction, always seek advice from
a specialist.
- Only operate the unit with clean hands.
- Do not force the controls.
- If the unit has fallen, always have it checked by a
qualified technician before you switch the unit on again.
- Do not use chemicals to clean the unit. They damage the
varnish. Only clean the unit with a dry cloth.
- Keep away from electronic equipment that may cause
interference.
- Only use original spares for repairs, otherwise serious
damage and/or dangerous radiation may occur.
- Switch the unit off prior to unplugging it from the mains
and/or other equipment. Unplug all leads and cables
prior to moving the unit.
- Make sure that the mains lead cannot be damaged when
people walk on it. Check the mains lead before every
use for damages and faults!
- The mains voltage is 220-240Vac/50Hz. Check if power
outlet match. If you travel, make sure that the mains
voltage of the country is suitable for this unit.
- Keep the original packing material so that you can
transport the unit in safe conditions
This mark attracts the attention of the user to high voltages that are present inside the housing and that are of
sufficient magnitude to cause a shock hazard.
This mark attracts the attention of the user to important instructions that are contained in the manual and that he
should read and adhere to.
DO NOT LOOK DIRECTLY INTO THE LENS. This can damage your eyes. Persons who are subject to epileptic
attacks should be aware of the effects that this light effect may have on them.
The unit has been certified CE. It is prohibited to make any changes to the unit. They would invalidate the CE certificate
and their guarantee!
NOTE: To make sure that the unit will function normally, it must be used in rooms with a temperature between 5°C/41°F
and 35°C/95°F.
Pls note! The use in France is only allowed to the professional user and not to the enduser. See decision:
www.legifrance.gouv.fr
-
-
-
-
-
-
-
-
-
Features of the product:






75mW green laser 532nm + 150mW red laser 650nm
Scanner system: big angle step motor
Working Modes: Sound Active, Auto run, DMX512 (9 CH), Master/slave mode
Interface: 3 pins XLR jack for DMX or Maser-Slave linking
Input power: AC 110V~240V, 50/60Hz. Rated power: 15W
Size: L*W*H=200*155*145mm; Weight: 1.5KG
Front and Rear panel view:
2
3
5
1
4
6. Power jack
2. Power LED indicator
7. Key Lock
3. Mic LED
8. DMX or linking jack
4. Sound active microphone
9. Sound sensitivity knob
5. ON/OFF switch
10. LED function setting screen
6
7
8
9
Press “UP” or “DOWN” to choose functions in the same menu.
Press “ENTER” button to enter next menu, or confirm the selected
Press “RETURN” button to return previous menu.
When you turn on the laser for the first time, it will take some seconds to auto load the built-in show.
10
First Menu
AUTO
Auto running mode
SOUD
Sound activate mode
AddE
Set DMX startadress
Second Menu
SP.-L (Low speed)
SP.-n (Normal speed)
SP.-H (High speed)
SP.-L (Low speed)
SP.-n (Normal speed)
SP.-H (High speed)
A001 – A512
CoL.1
CoLo
CoL.2
Set Laser color
CoL.3
CoL.4
AStE
YES
Set as Master unit
NO
TEST
TES1 (test pic with square)
Test mode
TES2 (test pic with tunnel)
Attention! L'utilisation en France est autorisée à l'utilisateur professionnel et non le consommateur.
Consultez decret: www.legifrance.gouv.fr
Universal DMX Operation (DMX mode)
This mode allows you to use universal DMX-512 console to operate.
1. Install the units in a suitable position.
2. Use standard XLR cable to connect your units together via the XLR connector on the rear of the units. For longer
cable we suggest a terminator at the last fixture.
3. Assign a DMX address to each the unit using dipswitches.
4. Turn on all units. Use DMX console to control your units.
DMX Signal
Instruction for DMX channels
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
000-063
064-127
128-191
Auto mode
192-255
Sound mode
000-255
Selecting built-in patterns
000-127
Manual rotation
128-191
Auto counter-clockwise rotation (from slow to fast)
192-255
Auto clockwise rotation (from slow to fast)
X axis
000-127
Manual rolling
rolling
128-255
Auto rolling (from slow to fast)
Y axis
000-127
Manual rolling
rolling
128-255
Auto rolling (from slow to fast)
X axis
0-127
Manual choose moving position
moving
128-255
Auto moving (from slow to fast)
Y axis
000-127
Manual choose moving position
moving
128-255
Auto moving (from slow to fast)
000-063
Choose pattern size, 0 is normal size, 1 is the smallest, 63 is the biggest
064-127
Auto zooming (-) from slow to fast
128-255
Auto zooming (+) from slow to fast
0~127
Choose every single color
128~191
Every single color changing one by one (slow to fast)
225~255
All the colors together changing alternatively in one pattern
Mode
Pattern
select
Rotation
Color
setting
TROUBLE SHOOTING
1. If the power indicator is off and the laser doesn't work, please check the power supply and the input.
2. In Stand-Alone operation, if the power supply indicator is ON and sound active indicator is OFF, but
the laser doesn't work.
A. Because sound is too small and cannot activate laser running, please increase the music volume
or increase audio sensitivity on rear panel.
B. Please check if unit has been set up in slave mode, or DMX mode.
3. In Master-Slave operation, slave units don't function, please check as below.
A. Make sure there's only one master in the chain, and the others are set in slave mode.
B. Make sure to control the units with DMX controller.
C. Make sure to use a good quality power cable and XLR connector.
4. In DMX operation, the unit can’t be controlled by the DMX console, but the DMX signal indicator is
flashing, please make sure the DMX console and unit have the same channel.
5. If the output beam direction above is unusual, please restart the unit.
6. If the unit is fail, please turn off the unit, and then turn on again after 5 minutes.
After trying the above solution you still cannot sort out the problem, please contact your dealer or
our company for service
CE Declaration of Conformity
Importer:
Tel :
Fax :
Product number:
152.939
Product Description:
Regulatory Requirement:
The product meets the requirements stated in the above mentioned Standards.
22-07-2013
Signature :
www.tronios.com
Copyright © 2013 by TRONIOS the Netherlands

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Languages

Only pages of the document in English were displayed