ZJ-S □□□ 取扱説明書

ZJ-S □□□ 取扱説明書
(66.6)
20.3
20
33.5
3.6
6
22.2
27.1
(39.5)
17
9.1
2−M3
39.2
13.6
7.6
アングル2
2−M3
取付穴加工寸法
20±0.1
プリアンプ
16
2-φ3.2取付穴
27.7
6
ZJ-S□□□
21.9
形
■外形寸法図
6
20
■定格
ZJ−SD100
ZJ−SDA11
測定距離
5∼100mm
最大測定電圧
(注1)
分解能
(注2)
直線性
(注3)
周囲湿度
動作時/保存時:35∼85%RH
応答時間
20ms
耐振動
保護構造
材質
質量
(梱包状態)
付属品
97±1
周囲温度
耐電圧
(46)
88±1
(φ15)
項目
ご承諾事項
(16.8)
(28.2)
形式
7.8
オムロン
(16.4)
電話
4.8
クイック
0120-919-066
(91)
75
29
4.8
FAX
055-982-5051 / www.fa.omron.co.jp
7.8
27
取付穴加工寸法
27±0.1
■営業時間:8:00∼21:00 ■営業日:365日
(28.1)
(11.8)
(11.8)
3.2
7
安全上の要点
アンプ側
*9052046-0D*
(18.2)
© OMRON Corporation 2006 All Rights Reserved.
2−M3
A v 2 0 1 4 年7月
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
Interference,in which case the user may be required to take adequate
measures to reduce interference
© OMRON Corporation 2006
All Rights Reserved.
PRECAUTIONS FOR SAFE USE
The following points are important to ensure safety, so make sure that they are
strictly observed.
(1) Installation Environment
• Do not use this product in environments where it can be exposed to
inflammable/explosive gas.
• Do not install this product close to high-voltage devices and power
devices in order to secure the safety of operation and maintenance.
(2) Power Supply and Wiring
• High-voltage lines and power lines must be wired separately from this
product. Wiring them together or placing in the same duct may cause
induction, resulting in malfunction or damage.
• Avoid connecting or disconnecting connectors while this product is
powered ON. Doing so may damage this product.
(3) Applicable Standards
• EN61326-1
• Electromagnetic enviroment :Industrial electromagnetic environment
(EN/IEC 61326-1 Table2)
(4) Other
• Do not disassemble, repair, or modify this product.
• Dispose of this product as industrial waste.
• Use the specified combinations of Sensor Head and Amplifier Unit.
This product is not compatible with the ZX series. Do not connect the
ZJ-S□□□ in combination with a ZX series Amplifier Unit.
• Use a DC power supply unit that has a countermeasure (Safety
Extra-Low Voltage power supply circuit) built-in for preventing high
voltages from occurring, or a UL Class 2 DC power supply unit.
• Be sure to ground the Sensor Head casing as it is connected to the 0 V
line of the internal circuit.
• Do not drop or subject this product to strong shock. Doing so might
cause it to malfunction.
• Allow a sufficient insulation distance against expected static electricity
to prevent static electricity discharge from being applied to the Sensor
Head. Failure to do so might cause this product to malfunction or
damage the sensing object.
7.6
(3) Fit the other end
27.7
Angle 2
2−M3
■Please doubly wrap and use the cable for the
ferrite core of the attachment as shown in the
figure below when you use this product as CE Hold the center and lift upwards.
acceptable goods.
It doubly wraps it.
Mount hole dimensions
20±0.1
Sensor side
• Preamplifier
Round vinyl insulated cable
3.7 dia. standard 1 m
Round vinyl insulated cable
5.2 dia. standard 0.2 m
Z-SDA11
5 to 100 mm
Maximum measurement
Standard mode: ±50 KV, High-precision mode: ±5 KV
(46)
• Preamplifier (when mounting by the Preamplifier Mounting Bracket)
power voltage (Note 1)
Resolution (Note 2)
Linearity (Note 3)
Standard mode: 10 V, High-precision mode: 1 V
Operating and storage: 0 to 50°C
Ambient humidity
Operating and storage: 35 to 85%
Response time
Dialectic strength
20 ms
(16.8)
97±1
±5%FS (Note 4)
Ambient temperature
7.8
1,000 VAC, 50/60 Hz for 1 min (Note 5)
Sensor Head: 10 to 55 Hz, 3-mm double amplitude,
45 min each in X, Y, and Z directions
Vibration resistance
Ferrite core
Amplifier side
Note:The length of the cable when the ferrite core is
used becomes about 75cm.
ZJ-SD100
Measurement distance
10mm or less
Preamp
97±1
Applicable amplifier unit
into the Mounting
Bracket.
(3) Next, fit the other end of the
Preamplifier into the Mounting
Bracket.
When removing the Preamplifier from
[Removing]
the Mounting Bracket, hold the center
of the Preamplifier and lift upwards.
88±1
Model
20.3
3.6
9.1
13.6
Rating
Item
Mounting Bracket.
39.2
Sensing section
(15 dia.)
whenever necessary.
(2) Fit one end into the
Angle 1
(28.2)
• Please keep this manual in a safe place so that it can be referred to
(1)
Use the ZX-XBT2 Preamplifier DIN
Track Mounting Bracket (order
separately) when mounting the
Preamplifier onto the DIN Track.
(2) Fit one end of the Preamplifier into [Installing]
the Mounting Bracket.
Preamplifier: 10 to 55 Hz, 1.5-mm double amplitude,
Suitability for Use
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED
FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
2 H each in X, Y, and Z directions
Degree of protection
Sensor Head: SUS
Materials
Weight (packed state)
Accessories
OMRON Corporation
IP20
Tokyo, JAPAN
• Preamplifier Mounting Bracket
Preamplifier: PC
(91)
75
29
Instruction sheet,Mounting bracket,Ferrite core
Note 1: Measured values sometimes might be saturated and correct values not
displayed if the distance to the sensor object is too short even if it is
within the measurement voltage range.
Note 2: This is the smallest value that can be read when the Amplifier Unit
(ZJ-SDA11) is connected.
Note 3: When the ambient temperature is fixed at 25°C
Note 4: When the measurement distance is 10 mm and the measurement
power voltage is -5 KV to +5 KV.
Note 5: In the case of a preamplifier (excluding Sensor Head)
4.8
(16.4)
4.8
Industrial Automation Company
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Approx. 250 g
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
(28.1)
your understanding of the product.
17
2−M3
(11.8)
(11.8)
engineering.
• To ensure correct use, please read this manual thoroughly to deepen
20
33.5
7.8
3.2
7
• The product must be operated by personnel knowledgeable in electrical
6
22.2
27.1
16
When using the product, be sure to observe the following:
(66.6)
(39.5)
20
Thank you for purchasing this Sensor Head.
2-3.2 dia.
mount hole
(18.2)
Instruction Sheet
[Fixing the Mounting Bracket]
(1) Fix the Preamplifier Mounting
Bracket (supplied with the product)
with M3 screws.
(1)
• Sensor Head
6
For ZJ-SDA□□□
Sensor Head
Preamplifier Installation
21.9
ZJ-S□□□
(1) Installation Site
Do not install this product in locations subjected to the following conditions:
• Ambient temperature outside the rating
• Rapid temperature fluctuations (causing condensation)
• Relative humidity outside the rating
• Presence of corrosive or flammable gases
• Presence of dust, salt, or iron particles
• Direct vibration or shock
• Direct sunlight
• Water, oil, or chemical fumes or spray
• Strong magnetic or electric field
(2) Power Supply and Wiring
• The cables must be 10 m or shorter in total length, for both the Sensor
Head and Amplifier Units. To extend the cable from the Sensor Head, an
optional double-ended cable (ZX-XC□A) must be used. For extension of
the cable of Amplifier Units, shielded cables of the same type must be
used.
• When using a commercially available switching regulator, make sure that
the FG terminal is grounded.
• If surge currents are present in the power lines, connect surge absorbers
that suit the operating environment.
• When connecting two or more Amplifier Units by Calculating Units
(ZX-CAL2), make sure that the linear GND lines of all Amplifier Units are
connected to each other.
(3) Warming Up
After turning ON the power supply, allow this product to stand for at least
30 minutes before use. The circuits are still unstable just after the power
supply is turned ON, so measured values may fluctuate gradually.
(4) Maintenance and Inspection
• Always turn OFF the power supply before adjusting or
connecting/disconnecting the Sensor Head.
• Do not use thinner, benzene, acetone or kerosene to clean the Sensor
Head and Amplifier Units.
(5) Mounting the Sensor Head
Do not allow anything to touch the metal casing of the Sensor Head. Doing
so might prevent normal measurement.
(6) Dust must not enter the measurement part.
Dimensions
6
PRECAUTIONS FOR CORRECT USE
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
27
Mount hole dimensions
27±0.1
2-M3
D s Oct, 20 14
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement

Languages

Only pages of the document in English were displayed