Honeywell 2000 Series, Pro TH2210D, 1000 Series, Pro TH2110D, PRO TH1100D, PRO 2000 Series Installation manual


Add to my manuals
22 Pages

advertisement

Honeywell 2000 Series, Pro TH2210D, 1000 Series, Pro TH2110D, PRO TH1100D, PRO 2000 Series Installation manual | Manualzz
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 1 Thursday, April 16, 2009 3:31 PM
Série
PRO 1000 / 2000 Series
Programmable and Non-programmable Thermostats
Thermostats programmables et non programmables
Termostatos programables y no programables
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 2 Thursday, April 16, 2009 3:31 PM
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 1 Thursday, April 16, 2009 3:31 PM
/
PRO 1000 / 2000 Series
Programmable and Non-programmable Thermostats
This manual covers the following models:
TH2110D and TH2210D
programmable thermostats
TH1100D, TH1110D and TH1210D
non-programmable thermostats
(Remove the thermostat from its wallplate to find the model number.)
System Types
TH1110D and TH2110D:
TH1210D and TH2210D:
•
•
•
•
•
•
•
Central heating - gas, oil, electric or
high-efficiency furnace (1H)
Central heating (see above) with air
conditioning (1H/1C)
Hot water system (steam or gravity) with or
without pump
Central air conditioners
750 mV heating systems
Heat pumps without auxiliary heating (1H/1C)
Heat pumps with auxiliary heating (2H/1C)
TH1100D:
•
•
•
Central heating - gas, oil, electric or
high-efficiency furnace (1H)
Hot water system (steam or gravity) with or
without pump
750 mV heating systems
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions
can damage the product or cause a hazardous condition.
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com
or call Honeywell Customer Care toll-free at 1-800-468-1502.
1
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 2 Thursday, April 16, 2009 3:31 PM
Installation Guide
Wallplate installation
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power
before beginning installation.
n
o
p
q
r
s
t
Loosen the locking screw at the bottom of the thermostat. Note that the screw is
captive and cannot be removed from the wallplate.
Separate the thermostat from the wallplate as per Figure 1.
Position the wallplate against the wall and mark hole positions with a pencil.
NOTE: Levelling is for esthetics only and will not affect the performance of the
thermostat.
Drill holes at the marked positions and insert supplied wall anchors.
Pass the wires through the large opening located at the bottom center of the wallplate
as per Figure 2.
Secure the wallplate to the wall with supplied mounting screws as per Figure 3.
Connect the wires to the terminals.
Figure 2
Figure 3
Figure 1
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash. Contact your local waste
management authority for instructions regarding recycling and proper
disposal.
2
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 3 Thursday, April 16, 2009 3:31 PM
PRO 1000 / 2000 Series
Wiring
Power supply. Provide disconnect means and overload protection as required.
Set the O/B jumper according to the type of reversing valve (see page 4).
Use a piece of wire (not supplied) to connect W and Y terminals to each other.
Optional 24 VAC common connection. If this connection is not made, use batteries
to power the thermostat.
This connection is not required for systems that provide heating only.
This connection is not required for systems that provide cooling only.
This connection is not required for systems that do not have an air recirculating fan.
Gas, oil or electric heating (1H)
Use
TH1100D
Heat
Gas, oil or electric heating and/or air conditioning (1H / 1C / 1H1C)
Compressor
Use
TH1110D
or
TH2110D
Fan
Heat
Heat pump without auxiliary heating (1H1C)
Compressor
Use
TH1110D
or
TH2110D
Fan
Reversing valve
Heat pump with auxiliary heating (2H1C)
Compressor
Fan
Use
TH1210D
or
TH2210D
Reversing valve
Auxiliary Heat
3
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 4 Thursday, April 16, 2009 3:31 PM
Installation Guide
Reversing valve setting
NOTE: This setting is necessary only if the thermostat is connected to a heat pump.
The jumper is located on the back of the thermostat faceplate. Set it according to the type
of reversing (changeover) valve used by the heat pump.
• O (factory setting): The reversing valve is energized when the System switch is set to
Cool (cooling mode).
• B: The reversing valve is energized when the System switch is set to Heat (heating
mode).
Incorrect jumper setting: The heat pump operation will be reversed; i.e., it will cool in
Heat mode and will heat in Cool mode.
Fan operation setting
NOTE: This setting is not applicable if a fan is not connected to the G terminal.
A jumper, located on the back of the thermostat faceplate, determines how the fan operates
in Automatic mode. This jumper is not available on TH1100, TH1210D and TH2210D. On
these models, when the fan is placed in Automatic mode, it starts right away when there is
a call for heat or cool.
• HG (factory setting): Leave the jumper in this position for gas or oil heating systems. In this
position, the heating system controls the fan operation. When there is a call for heat, the fan
starts only when the air coming out of the vents is sufficiently warm. When there is a call for
cool, the fan starts right away.
• HE: Place the jumper to this position for heat pump or electric heating systems. In this
position, the thermostat activates the fan as soon as there is a call for heat or cool.
Incorrect jumper setting: An incorrect setting is noticeable in a gas or oil heating system.
When heating starts, you will initially feel cold air coming out of the vents as the fan is
running before the furnace has enough time to heat up the air.
Battery installation
If a 24-VAC common wire is connected to the C terminal, batteries are
optional and serve to provide backup power.
If a 24-VAC common wire is not connected to the C terminal, batteries
are necessary to power the thermostat.
Install 2 AAA batteries on the back of the thermostat faceplate as
shown.
Thermostat mounting
n
o
p
Align the two brackets on the top of the thermostat with the
corresponding slots on the top of the wallplate.
Push the faceplate against the wallplate.
Tighten the screw at the bottom of the thermostat.
4
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 5 Thursday, April 16, 2009 3:31 PM
PRO 1000 / 2000 Series
Installer setup
Follow the procedure below to personalize and
configure the thermostat according to the heating/
cooling system.
o
p
Press
and
simultaneously (for three
seconds) until the display appears as shown
on the right.
Press
or
Function
number
to change the option.
Option
number
Press
and
for one second to advance to
the next function.
q
When the last function is displayed, press
and
for three seconds to save any changes
and exit the menu.
NOTE: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat
automatically saves any changes made and exits the menu. For programmable models only, at any
time you can save the changes and exit by pressing the Run button.
Function1
Default
setting
1
Temperature display format
0
0: Fahrenheit
1: Celsius
2
Time display format
0
0: 12-hour display
1: 24-hour display
3
Heating cycles per hour
5
2 to 6 cycles per hour
• 2: 30 min (steam, gravity)
• 3: 20 min (hot water, 90%+ high-efficiency furnace)
• 4: 15 min (gas or oil)
• 5: 12 min (gas or oil)
• 6: 10 min (electric)
4
Cooling cycles per hour
3
2 to 6 cycles per hour
5
Compressor protection2
1
0: Off
1: On
6
Adaptive Intelligent Recovery3
1
0: Off
1: On
7
Application4
0
0: Indoor mode: 40°F to 90°F (4.5°C to 32°C)
1: Garage mode: 35°F to 90°F (1.5°C to 32°C)
1
Depending on your thermostat model or your system type, some functions are non-available or
non-applicable.
2
Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the
compressor to wait 5 minutes before restarting. During the wait time, the message Cool On or Heat On
flashes on the screen. When the safe wait time has elapsed, the message stops flashing and the compressor
turns on.
3
Adaptive Intelligent Recovery™ allows the thermostat to “learn” how long your furnace or air conditioner
takes to reach the set temperature. Simply program the desired times and desired temperatures into the
schedule. The thermostat will determine when to activate heating or cooling so that the desired temperature
is attained at the desired time.
4
In Indoor mode, the minimum setpoint is 40°F (5°C) for frost protection. In Garage mode, the minimum
setpoint is 35°F (1.5°C) for energy savings.
5
n
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 6 Thursday, April 16, 2009 3:31 PM
Installation Guide
Specifications
Temperature Ranges
• Heat: 40 °F to 90 °F (4.5 °C to 32 °C)*
• Cool: 50 °F to 99 °F (10 °C to 37 °C)
Operating Ambient Temperature
• 32 °F to 122 °F (0 °C to 50 °C)
Shipping Temperature
• -40 °F to 130 °F (-40 °C to 55 °C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Physical Dimensions
• 4.7” H x 2.9” W x 1.1” D (120 mm H x 74 mm W x 28 mm D)
Power Supply
• 24 VAC or 2 AAA batteries
Maximum Load
• 1 A @ 24 VAC per output
6
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 1 Thursday, April 16, 2009 3:31 PM
/
Thermostats programmables
TH2110D et TH2210D
TH1210D et TH2210D :
•
•
•
•
•
•
•
Thermopompes
(2H1C)
avec
chauffage
TH1100D :
•
•
•
1
FRANÇAIS
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 2 Thursday, April 16, 2009 3:31 PM
n
o
p
q
r
FRANÇAIS
s
t
Figure 2
Figure 3
Figure 1
2
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 3 Thursday, April 16, 2009 3:31 PM
Utiliser le
TH1100D
Chauffage
Thermopompe avec chauffage d’appoint (2H1C)
3
FRANÇAIS
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 4 Thursday, April 16, 2009 3:31 PM
FRANÇAIS
•
Montage du thermostat
n
o
p
4
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 5 Thursday, April 16, 2009 3:31 PM
n
o
p
ou
q
0 : Fahrenheit
1 : Celsius
0
0 : format 12 heures
1 : format 24 heures
5
3
1
6 Adaptive Intelligent Recovery3
1
0 : Arrêt
1 : Marche
7 Application4
0
0 : mode Intérieur : 4.5 °C to 32 °C (40 °F to 90 °F)
1 : mode Garage : 1.5 °C to 32 °C (35 °F to 90 °F)
1
3 Cycles de chauffage/heure
1
2
3
FRANÇAIS
Fonction1
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 6 Thursday, April 16, 2009 3:31 PM
FRANÇAIS
• 1 A @ 24 V c.a. par sortie
6
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 1 Thursday, April 16, 2009 3:31 PM
/
TH1210D y TH2210D:
•
•
•
•
•
•
TH1100D:
•
•
•
1
•
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 2 Thursday, April 16, 2009 3:31 PM
n
o
p
q
r
s
t
Figura 2
Figura 3
Figura 1
2
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 3 Thursday, April 16, 2009 3:31 PM
Serie PRO 1000 / 2000
Bomba de calor sin calefactor auxiliar (1H1C)
Bomba de calor con calefactor auxiliar (2H1C)
3
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 4 Thursday, April 16, 2009 3:31 PM
Montaje del termostato
n
o
p
4
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 5 Thursday, April 16, 2009 3:31 PM
Serie PRO 1000 / 2000
n
o
p
o
q
1
2
Opciones
0
0: Fahrenheit
1: Celsius
0
0: formato 12 horas
1: formato 24 horas
3
5
4
3
2 a 6 ciclos por hora
5
1
6
Adaptive Intelligent Recovery3
1
7
Application4
0
0 : modo Interior : 4.5 °C a 32 °C (40 °F a 90 °F)
1 : modo Garaje : 1.5 °C a 32 °C (35 °F a 90 °F)
2
1
2
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 6 Thursday, April 16, 2009 3:31 PM
• 1 A a 24 V C.A. por salida
6
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 1 Thursday, April 16, 2009 3:31 PM
400-626-000-D (69-1968EFS-03 TH1000D_TH2000D installation manual).book Page 2 Thursday, April 16, 2009 3:31 PM
Automation and Control Systems
Solutions d’automatisation et de contrôle
Sistemas para automatización y control
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
http://yourhome.honeywell.com
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario M1V 4Z9
69-1968EFS-03 04-09
® U.S. Registered Trademark.
© 2009 Honeywell International Inc.
Patents pending. All rights reserved.
® Marque déposée aux É.-U.
© 2009 Honeywell International Inc.
Brevets en instance. Tous droits réservés.
® Marca registrada en EE.UU.
© 2009 Honeywell International Inc.
Patentes pendientes. Todos los derechos reservados

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Languages

Only pages of the document in English were displayed