![](http://s3.manualzz.com/store/data/029104637_1-5d0a9ffe5914d64db8fdad706389deac-128x128.png)
advertisement
▼
Scroll to page 2
of
36
![window/wall type room air conditioner | Manualzz window/wall type room air conditioner | Manualzz](http://s3.manualzz.com/store/data/029104637_1-5d0a9ffe5914d64db8fdad706389deac-360x466.png)
WINDOW/WALL - TYPE ROOM AIR CONDITIONER Model:KSTAW05C TA B L E O F C O N T E N T S Important Safety Instructions ......................1-3 Installation Instructions.................................4-7 Normal Sounds..............................................8 Air Conditioner Features............................8-10 Care and Cleaning...................................10-11 Troubleshooting Tip..................................11-12 Warranty Term..............................................13 Before using your air conditioner, please read this manual carefully and keep it for future reference. Producto 1 866 1 866 646 4332 646 4332 MIDEA AMERICA CORPORATION PRODUCT REGISTRATION CENTER 11800 NW 100 ROAD STE 4 MEDLEY FL 33178-1037 IMPORTANT SAFETY INSTRUCTIONS READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all. To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to property. Always do this. Never do this. WARNING Plug in power plug properly. Do not operate or stop the unit by inserting or pulling out the power plug. Do not damage or use an unspecified power cord. Otherwise, it may cause electric shock or fire due to excess heat generation. It may cause electric shock or fire due to heat generation. It may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufacturer or an authorised service centre or a similarly qualified per son in order to avoid a hazard. Always install circuit breaker and a dedicated power circuit. Do not operate with wet hands or in damp environment. Do not direct airflow at room occupants only. This could damage your health. Incorrect installation may cause fire and electric shock. It may cause electric shock. Always ensure effective grounding. Do not allow water to run into electric parts. Incorrect grounding may cause electric shock. It may cause failure of machine or electric shock. Unplug the unit if strange sounds, smell, or smoke comes from it. Do not use the socket if it is loose or damaged. It may cause fire and electric shock. It may cause fire and electric shock. Keep firearms away. Do not use the power cord close to heating appliances. It may cause fire. It may cause fire and electric shock. Ventilate room before operating air conditioner if there is a gas leakage from another appliance. Do not modify power cord length or share the outlet with other appliances. It may cause electric shock or fire due to heat generation. Do not open the unit during operation. It may cause electric shock. Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire. Do not disassemble or modify unit. It may cause failure and electric shock. It may cause explosion, fire and, burns. 1 IMPORTANT SAFETY INSTRUCTIONS CAUTION When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. Do not use strong detergent such as wax or thinner but use a soft cloth. Appearance may be deteriorated due to change of product color or scratching of its surface. Stop operation and close the window in storm or hurricane. Do not put a pet or house plant where it will be exposed to direct air flow. This could injure the pet or plant. Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock. Operation with windows opened may cause wetting of indoor and soaking of household furniture. When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury. Always insert the filters securely. Clean filter once every two weeks. Hold the plug by the head of the power plug when taking it out. Operation without filters maycause failure. It may cause electric shock and damage. Ventilate the room well when used together with a stove, etc. An oxygen shortage may occur. Do not use for special purposes. Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.It may cause deterioration of quality, etc. Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure. If bracket is damaged, there is concern of damage due to falling of unit. Turn off the main power switch when not using the unit for a long time. It may cause failure of product or fire. Do not place obstacles around air-inlets or inside of air-outlet. Do not place heavy object on the power cord and ensure that the cord is not compressed. Do not drink water drained from air conditioner. It may cause failure of appliance or accident. There is danger of fire or electric shock. It contains contaminants and could make you sick. Use caution when unpacking and installing. Sharp edges could cause injury. If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician. CAUTION This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge,unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The appliance shall be installed in accordance with national wiring regulations. Do not operate your air conditioner in a wet room such as a bathroom or laundry room. The appliance with electric heater shall have at least 1 meter space to the combustible materials. Contact the authorised service technician for repair or maintenance of this unit. Contact the authorised installer for installation of this unit. 2 IMPORTANT SAFETY INSTRUCTIONS WARNING NOTE: The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Device for details.In the event that the power supply cord is damaged, it cannot be repaired-it must be replaced with a cord from the Product Manufacturer. WARNING Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord. Grounding type wall receptacle Do not, under any circumstances , cut, remove, or byp ass the gro und ing prong. Power supply co rd with 3-pr ong gro unding plug and current dete ctio n de vice For Your Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING Prevent Accidents To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following: Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the the cabinet and behind the grille. If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, remove the screen completely before installation. Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit. When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils. WARNING Electrical Information The complete electical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation. Do not run air conditioner without side protective cover in place.This could result in mechanical damage within the air conditioner. Do not use an extension cord or an adapter plug. Operation of Cur rent Device NOTE: (Applicable to the unit adopts current detection device only ) The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following: 1. Plug in the Air Conditioner. 2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out. 3. Press the RESET button, again you will notice a click as the button engages. 4. The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.) Do not use this device to turn the unit on or off. Always make sure the RESET button is pushed in for correct operation. The power supply must be replaced if it fails reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer. If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the product manufacturer. NOTE:This air conditioner is designed to be operated under condition as follows: O Cooling operation Outdoor temp: Indoor temp: O O O 64-109 F/18-43 C (64-125 F/18-52 C for special tropical models) O O 62-90 F/17-32 C O 23-76 F/-5-24 C Heating Outdoor temp: operation Indoor temp: 32-80OF/0-27 C Note: Performance may be reduced outside of these operating temperatures. O O 3 IMPORTANT SAFETY INSTRUCTIONS CAUTION BEFORE YOU BEGIN Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Read these instructions completely and carefully. IMPORTANT- Save these instructions for local inspector s use. IMPORTANT- Observe all governing codes and ordianaces. Note to Installer- Be sure to leave these instructions with the Consumer. Note to Consumer- Keep these instructions for futrue reference. Skill level- Installatio of this appliance requires basic mechanical skills. Completion time- Approximately 1 hour. We recommend that two people install this product. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Warranty. You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner. Do not change the plug on the power cord of the air conditioner. Aluminum house wiring may present special problems- consult a qualified electircian. When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils. TOOLS YOU WILL NEED Screwdriver Level TOOLS YOU MAY USE WINDOW REQUIREMENTS Screwdriver Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches(584mm to 914mm) . Ruler or tape measure Scissors or knife INNER WINDOW SILL INTERIOR WALL NOTE: Wooden Windows Save Carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter, or when not in use. Table 1 4 INSTALLATION INSTRUCTIONS C: A lign the hole in the top rail with those in the top of the unit as shown in Fig.B PREPARE THE WINDOW Lower sash must open sufficiently to allow a clear vertical opening of 13 inches (330mm). Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage. Fig.B Mounting Hardware D: Secure the top rail to the unit with the 3/8 S crews as shown in Fig.C. 3/4 (or 1 / 2 ) Lock Frame Sash Lock Window sash Screws (1) seal fo am (2) (7) (1) F ig.C PREPARE AIR CONDITIONER A: Remove the air conditioner from the carton and place on a flat surface. NOTE: For safety reasons, all four(4) screws M UST be securely fastened. B: Remove top rail from the rear of the packaging material as shown in Fig. A. Top Rail Hardware or 3/8 Screws (4) Top Rail (1) INSTALL THE ACCORDION PANELS NOTE: Top rail and Sliding Pan els at ea ch side are offset to provide the prop er pitch to th e rear of (5 /1 6 ). This is n ecessary for prope r cond ensed w ater utiliza tion and dr ainage. If you are not u sing the Side Pan els for any reaso n, th is pitch to the r ear must b e maintained. Fig.A A.Place unit on floor, a bench or a table. Hold the Accordion Panel in one hand and gently pull back the center to free the open end. See Fig.1 Top R ail Packaging Fig.1 5 INSTALLATION INSTRUCTIONS B. Slide the free end " Ⅰ" section of the panel directly into the cabinet as shown in Fig. 2. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet. SECURE THE ACCORDION PANELS A.Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is agains t the window sill (Fig.5). Carefully close the window behind the top rail of the unit. Measure from the cabinet edge "Ⅰ"s ection About 5/8 to 3/4 INSIDE OUTSIDE Wooden Windows Fig.5 Fig.2 NOT E: Check that air conditioner is tilted back about 5/8 to 3/4 (tilted about 3 O to4 Odownward tothe outside). After proper installation, condensate should not drain from the overflow drain hole during normal use, correct the slope otherwise. C. Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. Fig.3. B.Extend the side panels out against the window frame (Fig.6). Top Rail window frame Fig.6 Bottom Rail Fig.3 INSTALL SUPPORT BRACKET D. Slide the panel all the way in and repeat on the other side. Fig.4 Top Rail A.Place the frame lock between the frame extensions and the window sill as shown(Fig.7). Drive 3 / 4 " (19mm)or 1 / 2 "(12.7mm) locking screws through the frame lock and into the sill . Top right Top left NOTE : To prevent window sill from s plitting,drill 1 / 8" (3mm) pilot holes before driving screws. Bottom Rail NOTE: If storm window blocks AC, see Fig. 11. Fig.7 6 INSTALLATION INSTRUCTIONS B.Drive 3/4" (19mm) or 1/2" (12.7mm) locking screws through frame holes into window sash (Fig.8). If AC is Blocked by Stor m Window Add wood as shown in Fig.11, or remove storm window before air conditioner is installed. If Storm Window Fram e must rem ain, be sure the drain holes or slots are not caulked or painted shut. Accumulated Rain Water or Condensation must be allowed to drain out. Removing AC From Window Turn AC off, and disconnect power cord. Remove sash seal from between windows, and unscrew safety sash lock. Remove screws installed through frame and framelock. Close (slide) side panels into frame. Keeping a firm grip on air conditioner, raise sash and carefully remove. Be carefully not to spill any rem aining water while lifting unit from window. Store parts WITH air conditioner. Fig.8 C.To secure lower sash in place, attach right angle sash lock with 3/4" (19mm) or 1 /2" (12.7mm) screw as shown(Fig.9). SASH Fig.9 Storm window frame or other obstruction. D.Cut Window sash seal foam and insert it in the space between the upper and lower sashes (Fig.10). 1-1/2"min (38 mm) FOAM SEAL Fig.11 Fig.10 7 Board thickn ess as req uire d, for pr oper pitch to rea r, along entir e sill. F asten with n ails o r screw s. NORMAL SOUNDS High Pitched Chatter High efficiency compressors may h ave a high pitched chatt er during the cooling cycle. Vibratio n Unit may v ibrate and make noise because of poor wall or window constructio n or incorrect installation. Soun d of R ushing Air At the front of the unit, you m ay hear the sound o f rushing air being moved by t he fan P inging or Sw itchin g Droplets of water hit ting condens er during normal operation may cau se pinging or switching sounds. Gurgle /Hiss Gurgling or hissing noise may be heard due to refrig erant passing through evaporator during normal operation. NOTE: All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevail. AIR CONDITIONER FEATURES ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin, thoroughly familiarize yourself with the control panel as shown below and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control alone or with the remote. TO TURN UNIT ON OR OFF: Press ADJUSTS TEMPERATUR E OR TIME Temp Temp Timer Timer On ACTIVATES TIMER Sleep SLEEP MO DE Timer CHECK FILTER RESET BUTTON ADJUS TS TEMPE RATURE OR TIM E DISPL AYS TEMP ERATURE OR TI ME OR ERROR CODES Off Che ck Filter A uto Auto Cool Low Dry M ed Fan H igh TO CHANGE TEMPERATURE SETT ING: Press / UP/DOWN button to change temperature setting. SET FAN SPEED SETS MODE Mode Fan E NERGY S AVER MODE NOTE:Press or hold either UP( ) or DOWN ( ) button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 62 OF(17 OC) and 86 OF(30 OC). If you want the display to read the actual room temperature, see To Operate on Fan Only section. Follow Me indicator (on so m e models) TURNS U NIT ON OR OF F Energ y Saver ON/OFF button to turn unit on or off. NOTE:Th e u ni t w i ll i ni ti a t e automatically the Energy Saver function under Cool, Dry,Auto(only Auto-Cooling and Auto-Fan) modes. Fo ll ow Me On/Off UNIT CONTROL 8 AIR CONDITIONER FEATURES TO ADJU ST FAN SPEEDS: TO SELECT THE OPERATING MODE: Press to select the Fan Speed in four steps-Auto, Low, Med or High. Each time the button is pressed, the fan speed mode is shifted. On Dry mode,the fan speed is controlled at Low automatically. To choose operating mode, press Mode button.Each time you press the button, a mode is selected in a sequence that goes from Auto, Cool, Dry and Fan. The indicator light beside will be illuminated and remained on once the m ode is selected. The unit will initiate automatically the Energy S aver function under Cool, Dry, Auto(only Auto-Cooling and Auto-Fan) modes. SLEEP FEATU RE: Press Sleep button to initiate the sleep mode. In this mode the selected temperature will increase by O O 2 F/1(or 2) C 30 minutes after the mode is selected. O The temperature will then increase by another 2 F/ O 1(or 2) C after an additional 30 minutes. This new temperature will be maintained for 6 hours before it returns to the originally selected tem perature. This ends the S leep mode and the unit will continue to operate as originally programmed. The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again. To operate on Auto feature: When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you. In this mode, the fan speed cannot be adjusted, it starts automatically at a speed according to the room temperature. To operate on Fan Only: CH ECK F ILTER FEATURE: Use this function only when cooling is not desired,such as for room air circulation or to exhaust stale air(on some models). (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer. During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode. In Fan only m ode ,the temperature is not adjusted. Press Check filter button to initiate theis feature. This feature is a reminder to clean the Air Filter for more efficient operation. The LED(light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the Check Filter button and the light will go off. ENERGY SAVER FEATURE: Press Energy saver button to initia te this function. This fu nction is availa ble on COO L, DRY, AUTO (only AUTO-COOLING and AUTO-FAN) modes.The fan will continue to run for 3 minute s after the compressor shu ts off.The fan then cycles on for 2 minutes at 10 minute intervals un til the roo m temperature is above the set temperature, at wh ich time th e compre ssor turns ba ck on and Cooling Starts. To operate on Dry mode: In this mode, the air conditioner will generally operate in the form of a dehumidifier. Since the conditioned space is a closed or sealed area, some degree of cooling will continue. TIMER: AUTO START/STOP FEATURE: When the unit is on or off, first press Timer button, the TIMER ON indicator light illuminates. It indicates the Auto Start program is initiated. When the time of TIMER ON is displayed ,press the Timer button again, the TIMER OFF indicator light illuminates. It indicates the Auto Stop program is initiated. Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours,then at 1 hour increments up to 24 hours.The control will count down the time remaining until s tart. The selected time will register in 5 seconds, and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on.(when the unit is off,there is no display.) Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timed program. FO LLOW ME F EATU RE: (on so me mo dels ) Light flashing En ergy Sav er Follow Me On/Off This feature can be ac tivated from the re mote control ONLY. The remote control se rve s as a remote thermostat a llowing for the precise te mpera ture control at its loc ation. To activate the Follow Me feature, point the remote control tow ards the unit and press the Follow Me button. T he remote dis play is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. If the unit does not receive the Follow Me signal during any 7 minutes interval, the unit will beep to indicate the Follow Me mode has ended. 9 AIR CONDITIONER FEATURES Air Directional Louvers DISPLAYS: Temp Temp Time r Timer Displays Air Dir ectio nal Louve rs DISPLAYS: O Lever O Shows the set temperature in " C " or " F " and the Auto-timer settings.While on Fan only mode,it shows the room temperature. Error codes: A S-Room temperature sensor error-Unplug the unit and plug it back in.If error repeats, call for service. NOTE:In Fan only mode,it will display " LO " or " HI " . - E vaporator temperature sensor error-Unplug the unit and plug it back in.If error repeats, call for servi ce. NOTE: " " is displayed as s hown in the left picture. HS - El ec tric heating sensor error-Unplug the unit and plug it back in.If error repeats, call for service. Air Direction The louvers will allow you to direct the air flow Left or Right throughout the room as needed. Move the Levers from side to side until the desired Left/Right direction is obtained. ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with. The Cool circuit has an automatic 3 m inute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping.The fan will continue to run during this time. The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other, press and hold the Left and Right Temp/Timer buttons at the same time, for 3 seconds. NOTE: If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes. CARE AND CLEANING Air Filter Cleaning CAUTION Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent chock or fire hazards. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils. 10 CARE AND CLEANING Cabinet Cleaning Air Filter Cleaning Remove the filter by sliding out from the right-hand side. Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure the filter is thoroughly dry before replacing. Or, instead of washing you may vacuum the filter clean. 。 。 Note: Never use hot water over 40 C(104 F) to clean the air filter. Never attempt to operate the unit without the air filter. Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. Never use harsh cleaners, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. Plug in air conditioner. Winter Storage If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton. TROUBLESHOOTING TIPS Before calling for service, review this list. It may save your time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance. Problem Solution Air conditioner does not start Wall plug disconnected. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Plug Current Device Tripped. Press the RESET button. Power is OFF. Turn power ON. Air from unit does not feel cold enough Room temperature below 62OF(17OC ). Cooling may not occur until room temperature O O rises above 62 F(17 C). Temperature sensing behind air filter element touching cold coil. Keep it from the cold coil. Set to a Lower temperature. Compressor stopped when changing modes. Wait for 3 minutes after set to the COOL mode. Air conditioner cooling, but room is too warm- ice forming on cooling coil behind decorative front. Outdoor temperature below 64OF(18OC). To defrost the coil, set FAN ONLY mode. Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode. Thermostat set too cold for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then, set temperature to a Higher setting. 11 TROUBLESHOOTING TIPS Problem Air conditioner cooling, but room is too warm- NO ice forming on cooling coil behind decorative front. Solution Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section. Temperature is set too High, set temperature to a Lower setting. Air directional louvers positioned improperly. Position louvers for better air distribution. Front of units is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit. Doors, windows, registers, etc. Open- cold air escapes. Close doors, windows, registers. Unit recently turned on in hot room. Allow additional time to remove Stored heat from walls, ceiling, floor and furniture. Air conditioner turns on and off rapidly Noise when unit is cooling Dirty air filter- air restricted. Clean air filter. Outside temperature extremely hot. Set FAN speed to a Higher setting to bring air past cooling coils more frequently. Air movement sound. This is normal . If too loud, set to a slower FAN setting. Window vibration - poor installation. Refer to installation instructions or check with installer. Water dripping INSIDE when unit is cooling. Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation instructions - check with installer. Water dripping OUTSIDE when unit is cooling. Unit removing large quantity of moisture from humid room. This is normal during excessively humid days. Remote Sensing Deactivating Prematurely (some models) Room too cold Remote control not located within range. Place remote control within 20 feet & 180 , radius of the front of the unit. Remote control signal obstructed. Remove obstruction. Set temperature too low. Increase set temperature. 12 AIR CONDITIONER WARRANTY One ONE-YEAR 1-866-646-4332 13 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Manual del Usuario INSTRUCCIONES IMPORTANTES DE LA SEGURIDAD WARNING Temperatura fuera Temperatura interior: Temperatura fuera Temperatura interior: INSTRUCCIONES DE INSTALACIÓN HEERAMIENTOS QUE NECESITE Approximadamente 1 horas. HERRAMIENTOS QUIZÄ NECESITE REQUISITOS DE LA VENTANA Lápiz Acodo Regla o cinta métrica EXTERIOR PARED DENTRO CERCA VENTANA umbral NOTA: INTERIOR PARED VENTANA DE MADERA Tabla 1 3/4” (or 1/2” ) Tornillos (7) Carril superior (1) Embalaje Carril superior Aproxima 5/8” a 3/4'' DENTRO VENTANA DE MADERA FUERA Carril superioro Carril inferior Carril superior Derecha superior Hoja NOTA: Ajuste la temperatura o reloj Receptor del signo del remoto ndicator de Seguirme ENERGY SAVER MODE CONTROL DE LA UNIDAD CARACTERÍSTICAS DEL AIRE ACONDICIONADO PARA MODIFICAR LA VELOCIDAD DEL VENTILADOR A elegir el modo operativo: FUNCIÓN DURMIENTA: On/Off RELOJ: FUNCIÓN DE AUTO EMPEZAR O TERMINAR: CARACTERÍSTICAS DEL AIRE ACONDICIONADO Pantallas: PANTALLAS: MANTENIMIENTO Y LIMPIEZA CAUTION Limpieza del Filtro de Aire La Limpieza del Gabinete GARANTIA DE AIR ACONDICIONADO MIDEA , A TRAVES DE SU CENTRO DE SERVICIO RESPONSABLE PARA GARANTIA costos de o dispositivo que EL CONSUMIDOR VA A SER se de servicio que se bajo RESPONSABILIDADES DEL CONSUMIDOR NORMALES 13 GARANTIA DE AIR ACONDICIONADO 1-866-646-4332. 14
advertisement
Related manuals
advertisement