SIMATIC NET Betriebsanleitung (kompakt) Operating Instructions (Compact) A5E00288912-05 Ausgabe / Release 07/2009 PS791-1PRO (Stromversorgung 110...230 / 24 V) PS791-1PRO (Power Supply 110...230 / 24 V) © SIEMENS AG 2009 Änderungen vorbehalten Subject to change without prior notice Copyright © Siemens AG 2009 All rights reserved The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens AG Industry Sector Postfach 4848, D-90327 Nuernberg Disclaimer of Liability We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcome. Technical data subject to change without prior notice. 2 ! ! Betriebsanleitung (kompakt) PS791-1PRO A5E00288912-05 3 4 Betriebsanleitung (kompakt) PS791-1PRO A5E00288912-05 L 1 7 9 1 -1 P S 0 0 -0 A A 6 M S 1 P o w e r N S V P J M 1 2 3 4 5 6 L 1 X 2 L 1 D C 2 4 V 0 .3 8 A N E C C L A S S 2 O U T P U T S IE M E N S X 1 5 0 ...6 0 H z A C 1 1 0 ...2 3 0 V 0 .2 A L Betriebsanleitung (kompakt) PS791-1PRO A5E00288912-05 5 6 Betriebsanleitung (kompakt) PS791-1PRO A5E00288912-05 ! ! • • 7 8 N PIN 2 -- PIN 3 L1 PE Betriebsanleitung (kompakt) PS791-1PRO A5E00288912-05 9 N Pin 2 -- Pin 3 Pin 1 24 V DC Pin 2 -- Pin 3 Masse Pin 4 -- 10 76 mm x 29 mm IP 65 6 – 9,5 mm 400 V / 600 V 16 A / 12 A EN60950, UL 1950 VDE0805, VDE0100 Betriebsanleitung (kompakt) PS791-1PRO A5E00288912-05 125 x 60 x 130 mm 750 g 90 – 265 V AC, 47 – 63 Hz 9W 80 % Ausgangsspannung 24 V DC 0,375 A <+/-2% <+/-1% 16 A ja keine ja Umgebungstemperatur -20 °C ... +60 °C EMV EN 61000-6-1 EN 61000-6-3 EN 60950, UL 60950-1 VDE 0805, VDE 0100 Betriebsanleitung (kompakt) PS791-1PRO A5E00288912-05 11 12 L1 Maßbild 791-1PS00-0AA6 S1 Power N L1 X2 L1 DC 24V NEC CLASS 2 OUTPUT PE X1 50 ... 60 Hz AC 110...230V L 60 M PS 791-1PRO 5 115 Betriebsanleitung (kompakt) PS791-1PRO A5E00288912-05 5 50 130 125 13 English Notes for the Reader Classification of Safety-Related Notices ! Warning indicates that death or severe personal injury can result if proper precautions are not taken. ! Caution with warning triangle indicates that minor personal injury can result if proper precautions are not taken. Caution without warning triangle indicates that damage to property can result if proper precautions are not taken. Notice indicates that an undesirable result or status can occur if the relevant notice is ignored. Note highlights important information on the product, using the product, or part of the documentation that is of particular importance and that will be of benefit to the user. 14 Operating Instructions (Compact) PS791-1PRO A5E00288912-05 English General Notes on the Device ! Warning Prior to startup, you must observe the notes in the Operating Instructions (Compact) of the PS791-1PRO. Qualified Personnel Only qualified personnel should be allowed to install and work on this equipment. Qualified persons are defined as persons who are authorized to commission, to ground, and to tag circuits, equipment, and systems in accordance with established safety practices and standards. Description of the PS791-1PRO Product Name: PS791-1PRO Note The exact name of the product and the order number can be found printed on the packing or on the device itself. Components of the Product The following components are supplied with the PS791-1PRO: • PS791-1PRO (Order no. 6GK5791-1PS00-0AA6) • 4-pin cable socket for line voltage • M12 Power Cord • Operating Instructions (Compact) Operating Instructions (Compact) PS791-1PRO A5E00288912-05 15 English Please check that the consignment you have received is complete. If it is not complete or if there is any external damage, please contact your supplier or your local Siemens office. Description of the Device L 1 The housing of the PS791-1PRO has the IP65 degree of protection and is intended for wall mounting with screws or for mounting on an S7-300 standard rail. 7 9 1 -1 P S 0 0 -0 A A 6 M S 1 P o w e r N S V P J M 1 2 3 4 5 6 L 1 X 2 L 1 D C 2 4 V 0 .3 8 A N E C C L A S S 2 O U T P U T S IE M E N S X 1 5 0 ...6 0 H z A C 1 1 0 ...2 3 0 V 0 .2 A P S 7 9 1 -1 P R O L Figure 1: Front Panel of the PS791-1PRO The front panel of the device contains the following operator controls and displays: • On/off switch S1 with protective cover • Power supply connector X1 for 110 V - 230 V AC input voltage • M12 socket for 24 V output voltage • Operating display L1 for 24 V output voltage 16 Operating Instructions (Compact) PS791-1PRO A5E00288912-05 English Caution The rated power of the PS791-1PRO is 9 W. Higher power consumption causes a thermal overload of the device that can cause damage or destruction of the PS791-1PRO. Installation and Commissioning Wall-mounted,S7-300 Standard Rail or DIN Rail To install the PS791-1PRO on a wall, you require four M4 screws. Note If you mount the device on a wall, the wall must be capable of supporting at least four times the weight of the device (weight of the device 750 g). The device can be installed on an S7-300 standard rail by hanging it on the rail using the upper bracket. With the preinstalled screw, the device is screwed into the lower rail groove. It is also possible to install the device on a DIN rail using the slider on the rear of the device. The PS791-1PRO can also be mounted on the housing of a SCALANCE W788 / SCALANCE W744 or SCALANCE X208PRO from below using 4 M4X80 screws (not supplied). Accessories for 24 V Connection To connect the M12 socket X2 with the SCALANCE products X788 and X744 and the SCALANCE X208PRO, you can use the supplied M12 power cord. As an alternative, you can assemble your own cable. The pin assignment of the X2 connector is described in the section Technical Specifications. Operating Instructions (Compact) PS791-1PRO A5E00288912-05 17 English Power Connection ! ! 18 Warning If the power supply cable is not perfectly sealed or the cable socket is not screwed on fully, there is a risk of danger to life due to the line voltage, if the PS791-1PRO is subjected to sprayed water or dampness! Put the PS791-1PRO power supply unit into operation only when the following conditions are met: • Use only power cables with a sealed connection to the cable socket. Refer to the assembly instructions for the cable socket in these operating instructions. • The union nut of the cable socket must be screwed onto the thread of the X1 male connector completely so that the seal of the cable socket is correctly in position. • A suitable socket with seal is screwed onto the X2 male housing connector for the output voltage or the male housing connector is covered by a protective cap. Warning The device must be connected and fused in the primary circuit according to the local regulations. The current consumption at 9 W rated load and 110 V input voltage is approximately 0.2 A (at 230 V input voltage 0.1 A). The short-time peak making current is 16 A. Operating Instructions (Compact) PS791-1PRO A5E00288912-05 English Figure 2: The Parts of the Cable Socket for 110...230 V AC A Socket with union nut B Socket sleeve C Seal D Cable bushing screw To connect to the line voltage, use a three-core cable with 0.5 - 2.5 mm² core cross-sectional area and 6 - 9.5 mm outer diameter. Follow the steps below to connect the cable socket to a power supply cable. 1. Unscrew the socket sleeve from the socket. Open the strain relief clamp. 2. Remove the cable bushing screw along with the seal from the socket sleeve. Operating Instructions (Compact) PS791-1PRO A5E00288912-05 19 English 3. Feed the power supply cable through the cable bushing screw, the seal and the socket sleeve. 4. Screw the wire end ferrules of the cable tight according to the pin designations shown on the terminals. Make sure that the protective earth of the power cable is somewhat longer than L1 and N. X1 Socket Pin 1 N Pin 2 -- Pin 3 L1 PE 5. Following this, strain relief clamp must be tightened so that the insulation of the power cable is completely covered by the clamp. The insulation of the power cable must be flush with the strain relief clamp. 6. Make sure that the power cable is not squashed by the strain relief. Any strain applied to the cable must not, however, affect the conductors or screw terminals. 7. Screw the socket sleeve onto the socket. 8. Insert the seal into the socket sleeve until the seal makes contact with the shoulder. 9. Screw the cable bushing into the socket sleeve until you are sure that the seal is pressed in to surround the cable firmly. This is intended to prevent dampness and sprayed water entering the connector. 20 Operating Instructions (Compact) PS791-1PRO A5E00288912-05 English Technical Specifications Pin Assignment of the PS791-1PRO X1 Socket Pin 1 N Pin 2 -- Pin 3 L1 PE X2 Socket Pin 1 24 V DC Pin 2 -- Pin 3 Ground Pin 4 -- Technical Specifications of the Cable Socket Dimensions (length, diameter) 76 mm x 29 mm Degree of protection housing IP 65 Cable diameter 6 – 9.5 mm Terminals, cable cross section Screw terminals 0.5 – 2.5 mm² Rated voltage 400 V / 600 V Rated current 16 A / 12 A Safety regulations EN60950, UL 1950 Class of protection 2 VDE0805, VDE0100 Operating Instructions (Compact) PS791-1PRO A5E00288912-05 21 English Technical Specifications of the PS791-1PRO 22 Dimensions (width x height x depth) 125 x 60 x 130 mm 750 g Power supply input 90 – 265 V AC, 47 – 63 Hz Rated power 9W Typical efficiency 80% Power supply buffering > 20 ms at UE 230 V AC Output voltage 24 V DC Output current 0.375 A Accuracy of output voltage <+/-2% Stability when load change 0-100% <+/-1% Inrush current 16 A Current limiting 1.8 x Irated Sustained short-circuit proof yes Base load none No load protection yes Residual ripple < 1 % of UA Operating temperature -20 °C ... +60 °C EMC EN 61000-6-1 EN 61000-6-3 Safety regulations EN 60950, UL 60950-1 Class of protection 2 VDE 0805, VDE 0100 Operating Instructions (Compact) PS791-1PRO A5E00288912-05 English Electromagnetic compatibility Directive 2004/108/EC The above SIMATIC NET products meet the requirements of the directive 2004/108/EC "Electromagnetic Compatibility". The EU conformity certificates are available for the relevant authorities according to the EU directive and are kept at the following address: Siemens AG Automation and Drives Industrial Communication SIMATIC NET Postfach 4848 D-90327 Nuernberg, Germany Operating Instructions (Compact) PS791-1PRO A5E00288912-05 23 English L1 Dimensional drawing 791-1PS00-0AA6 S1 Power N L1 X2 L1 DC 24V NEC CLASS 2 OUTPUT PE X1 50 ... 60 Hz AC 110...230V L 60 M PS 791-1PRO 5 24 115 5 50 130 125 Operating Instructions (Compact) PS791-1PRO A5E00288912-05
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project