Built-In Wall Oven 27" (68.6 cm) models JKS10, JKP30, JKP35, JKP55, JKP70, JKP75, PK916, PK956, ZEK938, ZEK958 Ilnstallat!on nstruct=ons 30" (76.2 cm) models JTP30, JTP35, JTP55, JTP70, JTP75, PT916, PT920, PT956, PT960, ZET938, ZET958 If you have questions, call 1.800.GE.CARES ge.com Before You Begin Read these instructions carefully and completely. • IMPORTANT-save instructions these for local inspector's • IMPORTANT-observe use. all governing codes and ordinances. • Note to Installer--Be sure to leave these instructions with the consumer. or visit our website at: • Proper installation is the responsibility of the installer and product failure due to improper installation is NOT covered under warranty. • NOTE--This grounded. appliance must be properly • ATTENTION INSTALLER • Note to Consumer--Keep these instructions for future reference. All electric wall ovens must be hard wired (direct wired) into an approved junction box. A plug and receptacle is NOT permitted on these products. Parts Included Materials Needed (Appearance will vary) Wire Nuts Screws For Installation (8-18 x .750 flat head Phillips wood screws) 27" (68.6 cm) Metal Bottom Trim Strain Relief Clamp for 1/2" conduit Junction Box 36" (91 cm) of String Tools Needed WB07T10578 - Black WB07T10579 - SS Optional 27" (68.6 cm) Metal Bottom Trim Assembly (on some models or can be purchased separately) 31-10647-3 11-07 JR 30" (76.2 cm) Metal Bottom Trim Assembly 1/8" (3 mm) Drill Bit and Electric or Hand Drill Phillips Screwdriver Installation instructions PORTANT SAFETY I ST CTIONS lectrical For Your Safety • Be sure your oven is installed properly by a qualified installer or service technician. Requirements • Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure. Weight on the oven door could cause the oven to tip and result in injury. Never allow anyone to climb, sit, stand or hang on the oven door. Rating plate is located on oven side trim, side front frame or lower front frame. Rating Plate Location • Make sure the cabinets and wall coverings around the oven can withstand the temperatures (up to 200°F [93.3°C]) generated by the oven. WARNING: We recommend you have the electrical wiring and hookup of your oven connected by a qualified electrician. After installation, have the electrician show you where your main oven disconnect is located. The electrical power to the oven supply line must be shut off while line connections are being made. Failure to do so could result in serious injury or death. Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, your oven must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70-Latest Edition. You can get a copy by writing: National Fire Protection Association Batterymarch Park Quincy, MA 02269 lectrical Requirements This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse. See the rating plate located on the oven frame to determine the rating of the product. Use the chart below to determine the minimum recommended dedicated circuit protection. KW Rating 240V KW Rating 208V Recommended Circuit Size (Dedicated) <4.8 KW <4.1 KW 20 Amp 4.9 KW-7.2 KW 4.3 KW-6.2 KW 30 Amp 7.3 KW-9.6 KW 6.3 KW-8.3 KW 40 Amp 9.7 KW-12.0 KW 8.4 KW-10.4 KW 50 Amp cont. Effective January 1, 1996, the National Electrical Code requires that new, but not existing, construction utilize a four-conductor connection to an electric oven. When installing an electric oven in new construction, a mobile home, recreational vehicle or an area where local codes prohibit grounding through the neutral conductor, follow the instructions in the section on NEW CONSTRUCTION AND FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION. You must use a three-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used. 2 Insta ion instructions Pre-lnstallation Chec Door removal is not a requirement for installation of the product, but is an added convenience. To remove the door: ALL INSTALLATION INFORMATION ON THE FOLLOWING PAGES IS TO BF USED FOR SINGLE AND DOUBLE OVEN INSTALLATION! [_ Remove packaging materials. Check behind hinges and under false bottom. Remove labels on the outside of the door, plastic on trims and panel, all tape around the oven, and any shipping screws securing the oven to the base pad. __ ist Open the oven door as far as it will go. Push both hinge _ :,,_ Hinge Unlocked locks down toward ,_I_:'_L Position the door frame, Hinge"I_ to the unlocked s_ot _.d position. This may require a flat blade Hinge screwdriver. Arm = [_ DO NOT LIFT THE DOOR [_ Place hands on both sides of the door, and close the oven door to the removal position, which is most of the way closed, [_ ift door up and out until the hinge arms clear the slots. "_ 11_ t_/ t _'/ Oven Racks _ iterature Pack Open oven door and remove literature pack and oven racks. Hinge Clears Slot NOTE: The oven door is very heavy. Be sure you have a firm grip before lifting the oven door off the hinges, Use caution once the door is removed. Do not lay the door on its handle. This could cause dents or scratches. Remove Installation Instructions from literature pack and read them carefully before you begin. Be sure to place all literature, Owner's Manual, Installations, etc. in a safe place for future reference. Place the oven on a table or platform even with the cutout opening. (Platform must support 150 Ibs. [68 Kg] single, 275 Ibs. [124 Kg] double.) Remove the bottom trim from the top of the oven. It will be installed at the end of the installation process. The trim is wrapped separately and taped to the top of the unit. 3 Installation instructions uilt-ln Cutout for 27" (68.6c )Single Ovens on y For JKS10, JKP30, JKP70, PK916, ZEK938 models only. Cabinet 5" (12.7 cm) Max. from the left or right Cabinet_ _sk I 27" (68.6 cm) Cutout for overlap of oven over side edges of cutout Width tOcm) 0¥ runners Box ,, : ,, "!-' level adjacent 1" (2.5 cm) ciearance°f 20" (50.8teCta),41 for _ a_jacen, corners, drawers, wails, etc. when door is open overlap of oven top and bottom of cutout'_"'_--_ minimum for Cutout Width 25" (63.5 cm) Min. Recommended cutout location from Roor 32 1/2" (82.6 Height 27 5/8" (70.2 cm) Min. 28 1/8" (71.4 cm) Max. I access from Box Location Allow" Allow a minimum 23 1/2" (59.7 cm) Min. Cutout 20" (50.8 era) " Depth 25 1/4" (64.1 cm) Max. 28 118" with bottom of cutout 32 1/2" (82.6 cm) Cutout /_ Cutout Height 22" (55.9 cm) 27 5/8" Min. above (70.2 cm) Min. base rail 2" x 4" (Scmx Junction Location 27" (68.8 cm) Recommended Cutout Location from Floor i 25" (63.5 cm) Min. j 25 114" (64.1 Max. Allow 1" (2.8 era) !_ / Width cabinet may be required NOTE: if the cabinet does not have a front frame and the sides are less than 3/4" (1.9 cm) thick, shim both sides equally to establish the cutout width. cm) 2" x 4" (5 cmx tO cm) or equivalent runners love| with bottom of cutout If the cabinet does not have a solid bottom, two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven. For single ovens, the runners and braces must support 150 Ibs (68 Kg). T 24" (61 cm) NOTE: If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered, 1 I-'_- 18" (45.7 cm) "-_1 "_ 27" (68,6 cm) "_ These ovens are not approved stackable installations. 4 for Installation instructions Cutoutfor 27"(68.6 Ovensonly For JKP35, JKP55, JKP75, PK956, ZEK958 models only. 5" (12.7 cm) Max. from the left or Cabinet right (68.6 cm) _ Cutout i __ Junction Box oven over 27" (68.6 cm) Recommended Cutout Location from Floor 13 1/4" (33.7 cm) Cutout Depth 23 5/8" (60 cm) Min. Cutout Width 25" (63.5 cm) Min. Location 5" (63.5 cm) Min. 25 1/4" i Allow 1" (2.5 cm) for overlap of Cabinet Width (s4.1cm) M_, side 25 114" (64.1 cm) Max. edges of cutout (111.8 cm) Cutout Height Min. icut°ut Above iHeight base rail i49 11116" i(126.2 cm) IVlin. 150 118" i(127.3 cm) Max. 50 1/8" (127.3 cm) Max. NOTE: If the cabinet does not have a front frame and the sides are less than 314" (1.9 cm) thick, shim both sides equally to establish the cutout width. 20" (50.8 --_ j°s- .... Ailo_v I" Allow a minimum of 20" (50.8 cm) for clearance to adjacent corners, drawers, walls, etc. when door is open (2,5 cm) for overlap of oven top and bottom_ 49 11116" (126.2 cm) Min. Recommended cutout location from floor 13 114" (33.7 cm) of cutout if the cabinet does not have a solid bottom, two braces or runners must be installed to support the weight of the oven. For double ovens, the runners and braces must support 300 Ibs (135 Kg). NOTE: If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered. -- Suitable Bracing to Support Runners Over Centerline of Cabinet 5 2" x 4" (ScmxtOcm) or equiva|ent ruuners level with bottom of cutout Installation instructions Cutout for 27" (68.6c_)Single Built-in Ovens only Under Counter For JKS10, JKP30, JKPT0, PK916, ZEK938 models only. Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for cutout size. See label on top of oven for approved cooktop models. \ 240V / 208V Junction Box Location 25" (63.5 cm) 5" (12.7 cm) Max. from the left or right side Gas and electrical connections for gas cooktop must be located in an adjacent accessible location to the right. Top and/or side fillers may be necessary if unit is positioned between existing cabinets. Be sure they are attached securely, since they will anchor the oven in the cabinet. _25" (63.5 cm) Min. 25 1/4" (64.1cm) Max. Allow I" (2.5 cm) unit overlap top bottom of oven, 1" (2.5 cm) unit overlap side edges 27 5/8" (70.2 cm) Min. 28 1/8" (71.4 cm) Max. _J J 22" (55.9 cm) Min. Above Support Platform _, 36" (91.4 cm) Typical Countertop Height 4"(10.2 cm) Typical Toekick MUST SUPPORT 150 LBS. (68 Kg) i 6 be installed under the specific models NOTE: This oven is only approved to I_t I_t JJJ Cabinetry for 27" (68.6 c_)Single or uilt-ln Ovens only- Over a Drawer For JKS10, JKP30, JKP35, JKP55, JKPT0, JKP75, PK916, PK956, ZEK938, ZEK958 models only. Double 27" (68.6 cm) Single 27" (68.6 cm) Oven Over Oven Over a Warming Drawer a Warming Drawer Anti-Tip Block Against Rear • Wall Per Warming Anti-Tip Block Against Rear Wall Per Warming Drawer Requirement Drawer Requirement 2" (5.1 cm) Min. 2" (5.1 era) Min, NOTE: Install the oven only with specific models listed on the label located on top of the oven. Per Warming Drawer Requirement J Per Warming Drawer Req= 1" (2.5 cm) Min. Above Toekick 1" (2.5 cm) Min. Above Toekick or Adjust to Oven Installation Height NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. When installing a Warming Drawer below a single or double oven, a separate 120V, 60 Hz, properly grounded receptacle must be installed. Refer to installation instructions packed with the Warming Drawer for specific installation requirements. 7 Cabinetry Cutoutfor 27"(68.6 o_)SingleOvensonlyBelowan Advantiumor ;rowave Oven or Betweenan Advantiumor crowave Ovenand a WarmingDrawer For JKS10, JKP30, JKP70, PK91& ZEK938 models only. Single 27" (68.6 cm) Oven Between an Advantium or Microwave Oven and a Warming Drawer Single 27" (68.6 cm) Oven Below an Advantium or Microwave Oven Per Advantium or Microwave Oven Requirement Per Advautium or Microwave Oven Requirement 2" (5.1 cm) Min. Note: Install the oven only with specific models listed on the label located on top of the oven. 2" (5.1 cm) Min. 2" (5.1 cm) Min. Per Warming Drawer Req NOTE: The middle rail separating the two openings may need to be larger than the 3" (7.6 cm) minimum shown. Always refer to the individual installation instructions packed with each product for specific requirements. NOTE: Additional clearances may be required. Check to be sure the oven supports above the Warming Drawer do not obstruct the required interior depth and height. The middle rail separating the openings may need to be larger than the 2" (5.1 cm) minimum shown. Always refer to the individual installation instructions packed with each product for specific requirements. Combined Advantium or Microwave Oven and Wall Oven Installation: When installed in combination with a single wall oven, use separate electrical junction boxes. Refer to the Advantium or microwave oven installation instructions for electrical requirements of that product. These connections must be made by a qualified electrician. All electrical connections must meet National Electrical Code or prevailing local codes. Warming DrawerCombinedwith Advantiumor MicrowaveOvenand Single Oven: Install a separate 120V, 60Hz, properly grounded receptacle. See installation instructions packed with each product for specific requirements. 8 Installation instructions Cutout for 30"(76.2c )Sing Ovensonly Built-in For JTP30, JTP70, PT916, PT920, ZET938 models only. Cutout Width 28 1/2" (72.4 cm) 9 1/2" (24.1 cm) Junction Box Location (junction box may be located in 5/8"(72.7 ore) Max. I Allow 11/16" I (1.75 cm) for overlap of oven over side edges of cutout 21 Opening Between inside Walls Must Be At Least 28 1/2" (72.4 cm) Wide / (69.2 cm) Min, 27 5/16" (69.4 cm) Ma 30" (76.2 cm) Recommended Cutout Location from Floor 32 1/2" (82.6 cm) Cutout Depth 23 1/2" (59.7 cm) Min. Cutout Width 28 1/2" (72.4 cm) Min. 28 518" (72.7 cm) Max. Cutout Height 22" (55.9 cm) Min. to Bottom of Junction Box 27 1/4" (69.2 cm) Min. 27 5/16" (69.4 cm) Max. ---4 - Ill not have a front frame and the t_1sides are less than 314" (1.9 cm) _AIl_w 1" (2.5 cm) minimum for overlap of oven top and 1V4" (3.2 cm) overlap of oven bottom of cutout Allow a minimum of 21" (53.3 cm) for clearance to adjacent drawers, walls, etc. when door is open cabinet) ---t " (53.3 cm)I'Y_'_ corners, adjacent Cabinet Width _--_ Recommended cutout location from floor 32 1/2" (82,6 cm) -- Cabinet Width 30" (76,2 cm) if the cabinet does not have a solid bottom, two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven. For single ovens, the runners and braces must support 150 Ibs (68 Kg). Suitable Bracing to Support Runners -- -_(s4 21 s/8.9 cm) over \ Centerline of Cabinet NOTE: if marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered, These ovens are not approved stackable installations. 2"x4" (5 cm x 10 cm or equivalent runners level with bottom of cutout Side by Side Installations Install two wall ovens in separate cutouts. Allow 2" (5.1 cm) min. between cutouts. Cutouti 2"(5.1 cm) Cutout Observe all Min. Observe all dimensions I_ll'='=='==='='=i_ dimensions and and I requirements. requirements.J for 9 Installation instructions Cutoutfor 30"(76.2 cm) Ovensonly For JTP35, JTP55, JTP75, PT956, PT960, ZET958 models Cutout Width 28 1/2" (72.4 cm) Min. -,_ 28 5/8" (72.7 cm) Max. 9 1/2" (24.1 cm) Junction Box n (junction box may be located Location in adjacent cabinet) _t /" Allow 11116" (1.75 cm) for overlap of oven over side edges of cutout Allow a minimum of 21" (53.3 cm) for clearance to adjacent \ 21" (53.3 cm)_ Cutout Depth 23 1/2" (59.7 cm) Min. Cutout Width 28 1/2" (72.4 cm) Min. 28 5/8" (72.7 cm) Max. Cutout Height I 47" (119.4 cm) Min. to Bottom of Junction Box Cutout AHow 1" (2.5 cm) minimum for overlap of oven top and 11/4" (3 2 cm) over ap of oven bottom - ofcutout 51 13/16" (131.6 cm) Min. 51 15116" (131.9 cm) Max. Inside Walls I Must Be At Least 28 1/2" (72.4 cm) Wide d rawers_ walls, etc. when door is open 30" (76.2 cm) Recommended Cutout Location from Floor 12" (30.5 cm) .__ Between corners_ Cabinet Width only. Height 51 13/16" 131.6 cm) Min. 51 15/16" (131.9 cm) Max I NOTE: If the cabinet does not have a front frame and the sides are less than 314" (1.9 cm) thick, shim both sides equally to establish the cutout width. " F - _-I -/1 Recommended --_ 30_ I cutout location (76.2 cm)"_;,_from f!oor 12" (30.5 cm) Cabinet _'_..L,_. Width I if the cabinet does not have a solid bottom, two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven. For double ovens, the runners and braces must support 275 Ibs (124 Kg). Suitable Bracing -to Support Runners NOTE: If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered, 10 2"x4" (Scm xtOcrn) or equiva|eut runners |eve| with bottom of cutout Installation instructions Cutout for 30"(76.2 Single only Under Coun :r lit-in Ovens For JTP30, JTPT0, PT916, PT920, ZET938 models only. Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for cutout size. See label on top of oven for approved cooktop models. 240V / 208V Junction Box \ 25" (63.5 Location (junction box may be in adjacent cabinet) 9 1/2" (24.1 cm) cm) Top and/or side fillers may be necessary if unit is positioned between existing cabinets. Be sure they are attached securely, since they will anchor the oven in the cabinet. Gas and electrical connections for gas cooktop must be located in an adjacent accessible location to the right. - 28 1/2" (72.4 cm) Min. 28 5/8" (72.7 cm) Max. overlap (2.5 cm) top Of oven_ -. 11/16" (1.8 cm) _,"- overlap side edges of cutout and 22" (55.9 cm) Min. Above Support Platform 36" (91.4 cm) Typical Countertop Height -- 1 114" (3.2 cm) overlap bottom Of oven, 24" (61 cm) 4" (10.2 cm) Typical Toekick NOTE: This oven is only approved to be installed under the specific models as labeled on this unit. Side by Side Installations Cutout - ] 2" (5.1 cm) Cutout Observe all| Min. Observe all dimensions d im e ns io n s_-,ql,,,,===,,,===,=,lm_" and and | requirements. requirements.J Install two wall ovens in separate cutouts. Allow 2" (5.1 cm) min. between cutouts. 11 Cabinetry Cutout for 30"(76.2c_) Single or Double L_i -in Ovens only- Over a _rrning Drawer For JTP30, JTP35, JTP55, JTP70, JTP75, PT916, PT920, PT956, PT960, ZET938, ZET958 models only. Single 30" (76.2 cm) Oven Over a Warming Drawer Double 30" (76.2 cm) Oven Over a Warming Drawer Block Against Rear Wall Per Warming Drawer Requirement Anti-Tip Block Against Rear Wall Per Warming 2" (5J cm) IVlin. Drawer Requirement NOTE: Install the 2" (5.1 cm) oven only with specific models listed on the label located on top of the oven. Per Warming Drawer Requirement IVlin. Per Warming Drawer Requirement 1" (2.5 cm) Min. Above Toekick or Adjust to Oven Installation Height 1" (2.5 cm) Min. Above Toekick NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. When installing a Warming Drawer below a single or double oven, a separate 120V, 60 Hz, properly grounded receptacle must be installed. Refer to installation instructions packed with the Warming Drawer for specific installation requirements. 12 Cabinetry Cutoutfor 30"<76.2 o_)SingleOvensonlyBelowan Advantium or _-rowaveOven or Betweenan Advantiumor crowave Ovenand a WarmingDrawer For JTP30, JTP70, PT916, PT920, ZET938 Single 30" (76.2 cm) Oven Below an Advantium or Microwave Oven models only. Single 30" (76.2 cm) Oven Between an Advantium or Microwave Oven and a Warming Drawer Per Advantium Microwave Oven Requirement __" 2" (5.1 cm) Min. (5.1 cm) Min, Note: Install the oven only with specific models listed on the label located on top of the oven. 2" (5.1 cm) Min. Per Warming Drawer Req NOTE: The middle rail separating the two openings may need to be larger than the 2" (5.1 cm) m=nimum shown. Always refer to the individual installation instructions packed with each product for specific requirements. NOTE: Additional clearances may be required. Check to be sure the oven supports above the Warming Drawer do not obstruct the required interior depth and height. The middle rail separating the openings may need to be larger than the 2" (5.1 cm) minimum shown. Always refer to the individual installation instructions packed with each product for specific requirements. Combined Advantium or Microwave Oven and Wall Oven Installation: When installed in combination with a single wall oven, use separate electrical junction boxes. • Refer to the Advantium or microwave oven installation instructions for electrical requirements of that product. These connections must be made by a qualified electrician. All electrical connections must meet National Electrical Code or prevailing local codes. Warming DrawerCombinedwith Advantiumor MicrowaveOvenand SingleOven: Install a separate 120V, 60Hz, properly grounded receptacle, See installation instructions packed with each product for specific requirements, 13 Installation instructions Electrical Connections ATTENTION Turn off the circuit breaker or remove fuses to the oven branch circuit. iNSTALLER All electric wall ovens must be hard wired (direct wired) into an approved junction box. A plug and receptacle is NOT permitted on these products. With the oven supported on a table or platform in front of the cabinet opening, connect the flexible conduit to the electrical junction box as shown below. Position the conduit in such a manner that it will lie on top of the oven in a natural loop when the oven is installed. You will need to purchase an appropriate strain relief clamp to complete the connection of the conduit to the junction box. DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not fit within the clamp, do not install the oven until a clamp of the proper size is obtained. Junction Box Location NOTE TO ELECTRiCiAN: The 3 power leads supplied with this appliance are UL recognized for connection to heavier gauge household wiring. The insulation of these 3 leads is rated at temperatures much higher than the temperature rating of household wiring. The current carrying capacity of the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire. Conduit WARNING: Improper Place oven on a connection of aluminum house wiring to copper leads can result in an electrical hazard or fire. Use only connectors designed for joining copper to aluminum and follow the manufacturer's recommended procedure closely. support to assist i connecting conduit 14 II Strain Relief Clamp (not included) must be used at Junction Box Installation instructions New Construction and Four=Conductor Branch Circuit Connection • When installing in new construction, Three=Conductor Branch Circuit Connection When connecting to a three-conductor circuit, if local codes permit: or a. Connect the bare oven ground conductor with the crimped neutral (white) lead to the branch circuit neutral (white or gray in color), using a wire nut. • When installing in a mobile home, or • When installing in a recreational vehicle, branch or • When local codes do not permit grounding through neutral: a. Cut the neutral (white) lead from the crimp. Re-strip the neutral (white) lead to expose the proper length of conductor. [__ound and \..j__ Jo.o.:, Box oo bo Connect the oven red lead to the branch circuit red lead in accordance with local codes, using a wire nut. c. Connect the oven black lead to the branch circuit black lead in accordance with local codes, using a wire nut. If the residence red, black or white leads are aluminum conductors, see WARNING on page 14. b. Attach the appliance grounding lead (green or bare copper) in accordance with local codes. If the residence grounding conductor is aluminum, see WARNING on page 14. d. Install Junction c. Connect the oven neutral (white) lead to the branch circuit neutral (white or gray) in accordance with local codes, using a wire nut. d. Connect the oven red lead to the branch circuit red lead and the oven black lead to the branch circuit black lead in accordance with local codes, using wire nuts. If the residence red, black or white leads are aluminum conductors, see WARNING on page 14. e. Install Junction Box Cover. 15 Box Cover. Installation instructions Securing the Oven Sliding the Oven into the Opening m In e Openin Drilling the Pilot Holes and Mounting the Oven a. Loop (do not tie) a 36" (91 cm) string around the conduit before the oven is slid into place. This will keep the conduit from falling behind the oven. NOTE: Before drilling the pilot holes, make sure the oven is pushed as far back into the opening as it will go and centered. a. Drill through the mounting holes (top and bottom) of the side trim, for the #8 screws provided. Pull out on string loop while pushing the oven into the cabinet Mounting Hole Locations (Hole may vary) b. Lift oven into cabinet cutout using the oven opening as a grip. Carefully push against oven front frame. Do not push against outside edges. c. As you slide the oven back, pull the string so that the conduit will lie on top of the oven in a natural loop. The screws must be a minimum of 1/4" (6 mm) from the front of the cutout. _k WARNING: Mounting screws must be used. Failure to do so could result in the oven falling out of the cabinet causing serious injury. d. When you are sure the conduit is out of the way, slide the oven 3/4 way back into the opening. Remove the string by pulling on one end of the loop. b. Secure the oven to cabinet with screws provided. NOTE: If the cabinet is particle board, you must use #8 x 3/4" particle board screws. These may be purchased at any hardware store. 16 Installation instructions [_ Preparing for the Bottom Trim Installation a. With oven installed, take the bottom trim and center it on the bottom front edge of the cabinet opening. b. Using the trim as a template, mark the center of each slot (two total) where the mounting holes will be drilled. c. Remove the trim. d. Drill pilot holes into the center of each template mark. a= For 27" (68.6 cm) models with Lower Trim in Position Mark (2) Hole Locations here Installing the Metal Bottom Trim Place the bottom metal trim centered over the pre-drilled mounting holes. Tape the edges of the trim down to maintain the alignment. b. Using two trim screws provided, secure the bottom trim to the bottom edge of the cabinet. Trim Screw Locations for , /Trim Side ._ 27"(68._cm)models with _.._ * Remove Lower Trim Before Pre-drilling Mounting Holes :or 30" (76.2 cm) models with Lower Trim in Position, Mark (2) Mounting Hole Locations here 1' Trim -..__ Trim Screw Locations for 30" (76.2 cm) models with Lower Trim IMPORTANT: if this unit is ever removed from the cabinet or the oven is ever pulled out for service, the trim must be removed first or damage to the trim will occur. 17 Installation instructions Replacing the Oven Door NOTE: The oven door is heavy. You may need help lifting the door high enough to slide it into the hinge slots. Do not lift the door by the handle. [=_ Open the oven door as far as it will open. [=_ Push the hinge locks up against the front frame of the oven cavity, to the locked position, Hinge in Locked Position Lift the oven door by placing one hand on each side. The door is heavy, so you may need help. Do not lift the door by the handle. Notch of Hinge Securely Fitted into Hinge Slot [=_ F_ With the door at the same angle as the removal position, which is most of the way closed, seat the notch of the hinge arm into the bottom edge of the hinge slot. The notch of the hinge arm must be fully seated into the bottom of the slot. Hinge Arm Bottom of Slot Edge Hinge Notch 18 Close the oven door. Installation instructions Pre-Test C ec Remove all protective and any stickers. ist Check that the bottom trim is installed properly (see page 17). film, if present, Check to be sure that all wiring is secure and not pinched or in contact with moving parts. Check to be sure the mounting screws are installed and flush with the side trim (see page 16). Operation Checklist Remove all items from the inside of the oven. NOTE TO ELECTRICIAN: The power leads supplied with this appliance are UL recognized for connections to larger gauge household wiring. The insulation of these leads is rated at temperatures much higher than the temperature rating of household wiring. The current carrying capacity of a conductor is governed by the wire gauge and also the temperature rating of the insulation around the wire. Check that conduit is securely connected to the junction box. Turn on the power to the oven. (Refer to your Owner's Manual.) Verify that the bake and broil units, and all cooking functions operate properly. Check that the circuit breaker is not tripped nor the house fuse blown. NOTE: ALUMINUM See your Owner's Manual for troubleshooting list. A. WIRING WARNING: IMPROPER CONNECTION OF ALUMINUM HOUSE WIRING TO THE COPPER LEADS CAN RESULT IN AN ELECTRICAL HAZARD OR FIRE. B, Splice copper wires to aluminum wiring using special connectors designed and UL approved for joining copper to aluminum, and follow the manufacturer's recommended connector procedure closely. NOTE: Wire used, location and enclosure of splices, etc., must conform to good wiring practice and local codes. 19 Notes 20 Modelos de 27" (68,6 cm) JKS10, JKP30, JKP35, JKP55, JKP70, JKP75, PK916, PK956, ZEK938, ZEK958 Modelos de 30" (76,2 cm) JTP30, JTP35, JTP55, JTP70, JTP75, PT916, PT920, PT956, PT960, ZET938, ZET958 I Visite nuestro sitio en la Web: ge.com Horno de pared empotrado vigentes. •iATENCION AL INSTALADORI Moldura de fondo metalica de 27" (68,6 cm) 4__ @ TLet__aSpar a Cord6n de 36" (91 cm) WBO7T10579 - SS Montaje de moldura de rondo Una broca de 1/8" (3 mm) para taladro 31-10647-3 11-07 JR o manual DE SEGURIDAD Para su seguridad cont. podria e incluso Potencia KW 208V <4,8 KW <4,1 KW 20 Amp 4,9 KW-7,2 KW 4,3 KW-6,2 KW 30 Amp 7,3 KW-9,6 KW 6,3 KW-8,3 KW 40 Amp 9,7 KW-12,0 KW 8,4 KW-10,4 KW 50Amp -- Ubicaci6n = ! ................... I iTODA LA INFORMACION PARA LA INSTALACION EN LAS PAGINAS SIGUIENTES ES PARA SER USADA EN LA INSTALACION DE HORNOS DE UNA O DOS UNIDADES! /_ Posici6n abierta de la bisagra Brazo de la bisagra iNO LEVANTE LA PUERTA LA EMPUNADURA! POR -<_ L -- _-J _ ? Bisagra sale de la ranura oderecho Ancho del_ gabinete _ 27" (68,6 cm) i _ ¢ 25" (63,5 cm) Min. 25 1/4" (64,1 cm) "i_' ! 22" (55,9 cm) iAItura idel corte i27 5/8" (70,2 cm) Min. __n iiiiii!i_i!iii}(!!_l! 20" (50,8 cm) '4 cm)M_x. Ancho del gabinete 27" (68,6 cm) 32 1/2" (82,6 cm) 23 1/2" (59,7 cm) Min. 25" (63,5 cm) Min. 25 1/4" (64,1 cm) Mbx. Altura de corte 27 5/8" (70,2 cm) Min. 28 1/8" (71,4 cm) Mbx. alterna ...... piso 32 1/2" (82,6 cm) 1 ! 24" (61 cm) I_•_ 18" (45,7 cm) 27" (68,6 cm) Ancho del _ gabinete _ 27" (68,6 cm). Ancho del gabinete J. I -i-._ '_,i'_ _/- 13 114"(33,7 cm) 25 1/4" (64,1 cm) M_x. 2" x 4" (5 cm x t0 cm) o correderas equivalentes 23 518" (60 cm) Min. Altura de corte 25" (63,5 cm) Min. 25 1/4" (64,1 cm) Max. 49 11/16" (126,2 cm) Min. 50 1/8" (127,3 cm) Max. 20" (50,8 j_oJooooi -'I 27" (68,6 cm) Abrazaderas -- 25" (63,5 cm) 25" (63,5 cm) Min. 25 1/4" (64,1 cm) Mbx. 1. 27 5/8" (70,2 cm) Min. 28 118" (71,4 cm) M_x. s :i 36" (91,4 cm) Altura tipica del gabinete 24" (61 cm) 4" (10,2 cm) Zocalo tipico Gabinetes I_1Disyuntor para27"(68,6cm)Solamente parahornos individuales - Debajo deunAdvantium odeun horno demicroondas oEntreunhorno Advantium o unhornodemicroondas yGaveta decalentamiento Para los modelos JKS10, JKP30, JKP70, PK916, ZEK938 solamente. Hornoindividualde27"(68,6cm) debajode unhornoAdvantiumo un hornode microondas Por Advantium de microondas o horno requisitos 2" (5,1 cm) Min. Hornoindividualde 27"(68,6cm) EntreunhornoAdvantiumo unhornode microondasy unagavetadecalentamiento Por Advantium de microondas o horno requisitos 2" (5,1 cm) Min. 2" (5,1 cm) Min. 9 1/2" (24,1 cm) -_ _ -- . -- Mbx_ / _ I I / I I I I (72,4 cm) de ancho i 27 1/4" _, (69,2 cm) Min. 27 5/16" (69,4 cm) Mbx. "- '_ I 32 112"(82,6 cm) 23 112" (59,7 cm) Min. 28 112"(72,4 cm) Min. 28 518" (72,7 cm) Max. Altura de corte 27 1/4" (69,2 cm) Min. 27 5/16" (69,4 cm) Max. --NOTA:Si el gabinete no tiene un marco 30" (76,2 cm) gabinete Ubicaci6n Profundidad -- 2" x 4" (5 cm x 10 Cm) Ancho del gabinete 30" (76,2 cm) O Abrazaderas cm) Linea de centro sobre \ gabinetes Corte para los hornos de dos unidades de 30" (76,2 cm)solamente Para los modelos JTP35, JTP55, JTP75, PT956, PT960, ZET958 solamente. Ancho del corte 28 1/2" (72,4 cm) Min. _r28 5/8" (72,7 cm) M&x. 9 112" (24,1 cm) M&x. I F [ I [ [ )_- _ 12" (30,5 cm) 23 112"(59,7 cm) Min. 28 112"(72,4 cm) Min. I 28 518" (72,7 cm) Max, I I Altura de corte I 51 13/16" (131,6 cm) Min. I I (72,4 cm) de ancho (131,6 cm) Min, 51 15/16" (131,9 cm_ M&x " " " i (3,2cm) por 21" 30" (76,2 cm) I I : I [ L I I ' i -- (53,3 cm 2" x 4" (5 cm x 10 cnl) A_cho del_'_ _ga_l;ine_e ' _1 / I I 30" (76,2 cm) 10 O - 28 112" (72,4 cm) Min 28 518" (72,7 cm) M_x.. 27 114" (69,2 cm) Min. 27 5116" (69,4 cm) M_x. :::L_. 22" (55,9 cm) Min. Por encima de la plataforma de soporte 36" (91,4 cm) Altura tipica del gabinete (10,2 cm) Z6calo tipico separados. Deje 2" (5,1 cm) min. 11 Horno individual de 30" 12 Gabinetes Disyuntor para30"(76,2cm)Solamente parahornos individuales - Debajo deunAdvantium o deun hornodemicroondas o EntreunhornoAdvantium o unhornodemicroondas y Gavetadecalentamiento Para los modelos JTP30, JTP70, PT916, PT920, ZET938 solamente. Hornoindividualde30"(76,2cm) debajode unhornoAdvantiumo un hornode microondas Hornoindividualde 30"(76,2cm) EntreunhornoAdvantiumo unhornode microondasy unagavetadecalentamiento Por Advantium Por Advantium o horno de microondas requisitos 2" (5,1 cm) Min. 2" (5,1 cm) Min. microondas requisi Nota: Instale el L_.:_:_--.... i I II I I I L_ 2" (5,1 cm) Min. I ,_....... 111 II ....... _1_ J 14 i--- -i b= caja C= '--' a, J 16 I_] a. b° * Retire la moldurainferior inferior antes de pretaladrar _o, orifieios de moetaje __S_ll lie, _-_llllHIll' _llllHIIJ _ _J "_,,_'_ J IIHII tS I'l; Moldura lateral o, ura._ moldura de fondo aqui 17 _'-_ _] 18 [_ etire cualquier cinta este de proteccion etiqueta que todavia presente. y [_ NOTA AL ELECTRICISTA: articulo del interior y NOTA: CABLEADO A. DE ALUMINIO ADVERTENCIA: UNA CONEXION DEL CABLEADO INAPROPIADA DEL ALUMINIO RESIDENCIAL CON EL COBRE, PODR|A RESULTAR EN PROBLEMAS SERIOS O EN INCENDIO. para B= 19 Notas 20
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project