IMPORTANTI ISTRUZIONI PER LA SICUREZZA
F
INSTRUCTIONS IMPORTANTES POUR LA SECURITE
GB
IMPORTANT SAFETY INSTRUCTIONS
WARNING - IT IS IMPORTANT FOR THE SAFETY OF PERSONS
TO FOLLOW ALL INSTRUCTIONS
1° - This instruction booklet is exclusively dedicated to specialized staff who are aware of
the construction criteria and of the accident prevention protection devices for motorized
gates and doors (according to the current regulations and laws).
2° - Keep the automatic control (push-button, remote control, etc) out of the reach of children.
The control systems must be installed at a minimum hight of 1.5m from the ground surface
and not interfere with the mobile parts.
3° - Before starting any installation and operation or maintenance work make sure to cut off
power supply by turning the general magnetothermic switch off.
WARNING - INCORRECT INSTALLATION CAN LEAD TO SEVERE INJURY
RIB IS NOT LIABLE for any damage caused by not following the safety regulations and laws at
present in force not being observed during installation.
SAVE THESE INSTRUCTIONS
D
WICHTIGE ANWEISUNGEN FÜR DIE SICHERHEIT
Pag. 2 di 28
INDEX
Technical Features ................................................................................................pag.15
Checking before the Installation ............................................................................pag.15
Motor and rack fitting .............................................................................................pag.15
Limit switch adjustment, Emergency release system, Maintenance .....................pag.16
Connections ..........................................................................................................pag.17
Checking the rotation direction of the motor, Timing ............................................pag.18
Operation of Operating Accessories......................................................................pag.18
Operation of Safety Accessories ...........................................................................pag.18
Optionals => EXPANDER card, INVERTER card, etc. ...................................pag.19-20
Declaration of Compliance.....................................................................................pag.27
Exploded view........................................................................................................pag.28
Pag. 3 di 28
LAY-OUT IMPIANTO
TIPO DI COMANDO
Fig. 2
CARATTERISTICHE
TECNICHE
K1800
Kg
1800
m/sec
0,166
N
Cremagliera modulo
4
230V~ 50-60Hz
Fig. 4
640
W
257
A
1,18
µF
12,5
n°
9 - 60s/2s
AGIP GR SLL 00
Kg
db
<70
°C
-10 ÷ +70°C
IP
54
10,5
I
T
A
L
I
A
N
O
I
T
A
L
I
A
N
O
Pag. 4 di 28
Misure in mm
3 - FISSAGGIO FINECORSA
Fig. 5
COLLEGAMENTI ELETTRICI
Pag. 5 di 28
4 - CONNESSIONI
QUADRO ELETTRONICO KS
J1 => EXP.
J2 => SEC.TRANSF.
J3 => L1 - N
NON TOCCARE IL PONTICELLO !
SE VIENE RIMOSSO L’OPERATORE NON FUNZIONA!
J10 => MOTOR
J11 =>
BC07050
SEGNALAZIONI LED
DL1
DL2
DL3
DL4
DL5
DL6
DL7
DL8
DL9
I
T
A
L
I
A
N
O
I
T
A
L
I
A
N
O
Pag. 6 di 28
5 - CONTROLLO SENSO DI ROTAZIONE DEL MOTORE
FUNZIONAMENTO ACCESSORI DI SICUREZZA
OPTIONALS
FUNZIONI AGGIUNTIVE CON SCHEDA EXPANDER (ACG5470)
SCHEDA INVERTER (ACG9201)
!! RIMUOVERE IL CONDENSATORE DEL MOTORE !!
SCHEDA RISCALDATORE HEATER (ACQ9092)
ACG6082 - 433
ACG7026 - 91
ACG6081 - 433
ACG7025 - 91
*
*
*
*
*
MOON 91 (30,925MHz) - 2CH Cod. ACG7025 - 4CH TX91 Cod. ACG7026
Rif. Certificato Min P.T. di esame CE N. EMC/98/IST/012
Autorizzazione Min P.T. DGPGF/SEGR/2/07/336915/FO
CERTIFICATO DI CONFORMITA' CE DI TIPO
CERTIFICATE OF CONFORMITY (GERMANY)
CERTIFICATE EXPERT OPINION (GERMANY)
*
*
*
*
*
*
MOON 433 (433,92MHz) - 2CH Cod. ACG6081 - 4CH Cod. ACG6082
Rif. Certificato Min P.T. di esame CE N. EMC/97/084
Autorizzazione Min P.T. CEPT LPD-I DGPGF/4/2/03/338529/FO/
CERTIFICATO DI CONFORMITA' CE DI TIPO
CERTIFICATE OF CONFORMITY (GERMANY)
CERTIFICATE EXPERT OPINION (GERMANY)
I
T
A
L
I
A
N
O
I
T
A
L
I
A
N
O
RADIO RICEVITORI
RX91/A
RX91/A
RX433/A
RX433/A
RX433/A 2CH
RX433/A 2CH
cod.ACG5005
cod.ACG5004
cod.ACG5055
cod.ACG5056
cod.ACG5051
cod.ACG5052
OLIVA IN NYLON
ACG4010
ACG7059
SELETTORE A CHIAVE BLOCK DA PARETE
SELETTORE A CHIAVE BLOCK DA INCASSO
cod.:ACG1053
cod.:ACG1048
cod: ACG8107
Pag. 9 di 28
SCHÉMA DÉTAILLÉ DE
L'INSTALLATION
TYPE DE COMMANDE
A
C
C
CeD
K1800
Kg
1800
m/sec
0,166
4
Fig. 4
640
230V~ 50-60Hz
W
257
Absorption
A
1,18
µF
12,5
n°
9 - 60s/2s
Poids maximum
Kg
10,5
Bruit
db
<70
Temperature de travail
°C
-10 ÷ +70°C
IP
54
F
R
A
N
Ç
A
I
S
E
F
R
A
N
Ç
A
I
S
E
Fig. 5
ENTRETIEN
Fig. 6
Pag. 11 di 28
4 - BRANCHEMENTS
J2 => SEC.TRANSF.
J4 => PRI.TRANSF.
J5 =>
NE TOUCHEZ PAS LE PONTET!
S'IL EST ENLEVÉ, L'OPÉRATEUR NE SE DÉPLACE PAS!
J8 => CAPACITOR
J9
LSO
COM.
LSC
J10 => MOTOR
J11 =>
J12
AERIAL
COM
PHOT.1 NC
J13 => INVERTER
J14
STOP
OPEN
CLOSE
K BUTT.
A*A
SIGNAL
BC07050
J17 => INVERTER
F
R
A
N
Ç
A
I
S
E
F
R
A
N
Ç
A
I
S
E
Pag. 12 di 28
5 – CONTRÔLE DU SENS DE ROTATION DU MOTEUR
CARTE RÉCHAUFFEUR HEATER (ACQ9092)
ACG6082 - 433
ACG7026 - 91
ACG6081 - 433
ACG7025 - 91
*
*
*
*
*
MOON 91 (30,925MHz) - 2CH Code ACG7025 - 4CH TX91 Code ACG7026
Réf. Certificat Min P.T. d'examen CE N. EMC/98/IST/012
Autorisation Min P.T. DGPGF/SEGR/2/07/336915/FO
CERTIFICAT DE CONFORMITÉ CE DE TYPE
CERTIFICATE OF CONFORMITY (GERMANY)
CERTIFICATE EXPERT OPINION (GERMANY)
*
*
*
*
*
*
MOON 433 (433,92MHz) - 2CH Code ACG6081 - 4CH Code ACG6082
Réf. Certificat Min P.T. d'examen CE N. EMC/97/084
Autorisation Min P.T. CEPT LPD-I DGPGF/4/2/03/338529/FO/
CERTIFICAT DE CONFORMITÉ CE DE TYPE
CERTIFICATE OF CONFORMITY (GERMANY)
CERTIFICATE EXPERT OPINION (GERMANY)
F
R
A
N
Ç
A
I
S
E
F
R
A
N
Ç
A
I
S
E
Pag. 14 di 28
RADIORÉCEPTEURS
RX91/A
RX91/A
RX433/A
RX433/A
RX433/A 2CH
RX433/A 2CH
cod.ACG5005
cod.ACG5004
cod.ACG5055
cod.ACG5056
cod.ACG5051
cod.ACG5052
Olive en Nylon
code ACS9050
ACG4010
ACG7059
BLOCK - SÉLECTEUR À CLÉ MURAL
BLOCK - SÉLECTEUR À CLÉ ENCASTRER
code.:ACG1053
code.:ACG1048
code ACG4655
PLAQUE À CIMENTER
code ACG8107
Refermer le carter
Pag. 15 di 28
1 - K operating device
2 - External photocells
3 - Rack of Module 4
4 - Key selector
5 - Radio antenna
6 - Blinker
7 - Travel limiting devices (cams)
8 - Mechanical strip
9 - Pneumatic strip or Fotocosta
10 - Internal Photocells
11 - Photocell posts
12 - Mechanical stops
Fig. 1
Parts to install meeting the EN 12453 standard
1 - CHECKING BEFORE THE INSTALLATION
!! THE GATE SHALL MOVE FRICTIONLESS !!
N.B.: Gate features must be uniformed with the standards and laws in
force.
The guide must be provided with two mechanical stops at its ends (12)
(Fig. 2).
Gate columns shall have anti-derailment guides on their top (Fig. 3), to
avoid the unintentional gate release.
N.B.: Eliminate those mechanical stops of the kind described by figure 3.
No mechanical stop shall be on top of the gate, since mechanical stops
are not safe enough.
COMMAND TYPE
with manned operation
with visible impulses (e.g. sensor)
with not visible impulses (e.g. remote control device)
automatic
USE OF THE SHUTTER
Skilled persons
(out of a public area*)
A
C
C
CeD
Skilled persons
(public area)
B
C
CeD
CeD
Unrestricted use
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated), like code ACG2020
B: Key selector with manned operation, like code ACG1010
C: Safety edges, like code ACG3010
D: Photocells, like code ACG8026
TECHNICAL FEATURES
Irreversible operating devices for sliding gates with a maximum weight of 2.200
Kg/4900lbs.
The irreversibility of this operating device allows you to avoid using any electric lock for
an effective closing of the gate. The motor is protected by an heat probe, that temporary
interrupts the operating cycle in case of prolonged use.
Fig. 2
TECHNICAL
DATA
Max. leaf weight
K1800
Kg/lbs
Operating speed
0,166m/sec - 32,6 ft/min
Thrust force to constant turns
640N-144lbs
Rack
4
EEC Power supply
Fig. 3
RELEASE
To operated after the power supply to the motor has been interrupted.
In order to work manually on the gate, you just need to insert the fitting key and rotate It
3 times counterclockwise (Fig. 4).
Fig. 4
1800/3960
230V~ 50-60Hz
Motor capacity
W
257
A
1,18
Capacitor
µF
12,5
No. cycles
n°
9 - 60s/2s
AGIP GR SLL 00
Grease
Weight of electroreducer
10,5Kg/23lbs
Noise
db
<70
Working temperature
°C
-10 ÷ +70°C
Protection
IP
54
Pag. 16 di 28
Dimensions in mm/inches
6,6”
4,86”
The rack shall be fitted over the motor support, at a certain distance from It.
Its height can be adjusted thanks to the holes In the rack.
The height is adjusted to prevent the gate from resting on the driving gear of the K as it
moves (Fig. 5,6).
To fix the rack on the gate, drill some Ø 5 mm holes and thread them using an M6 screw
tap.
The driving gear needs some 1 mm clearance from the rack.
1,5”
0,2”
In order to determine the travel of the moving part, place two cams at the ends of
the rack (Fig. 7).
Move the cams on the rack teeth to adjust their opening and closing travel.
To fix the cams to the rack, tighten the screws issued.
N.B: In addition to the electric stop cams mentioned above, you must also install strong
mechanical stops preventing the gate from sliding out of the top guides.
Fig. 5
6,6”
0,2” 4,86”
1,5”
10,6”
MAINTENANCE
To be carried out exclusively by skilled persons after the power supply to the
motor has been interrupted.
Periodically clean and keep the guide free from stones when the gate is standstill.
Fig. 6
ELECTRIC CONNECTIONS
Pag. 17 di 28
4 - CONNECTIONS
Connector for EXP card
J2 => SEC.TRANSF.
J3 => L1 - N
Connector for secondary transformer
Power supply 230 Vac 50/60 Hz
J4 => PRI.TRANSF. Connector for primary transformer
J5 =>
DO NOT TOUCH THE JUMPER !
IF IT IS REMOVED THE OPERATOR DOESN’T MOVE !
Connector to the manual release safety device
Connector to the Encoder (on K PLUS)
J8 => CAPACITOR Connector to the capacitor
J9
LSO
COM.
LSC
Limit switch contact stopping the motor opening
Contacts common unit
Limit switch contact stopping the motor closing
J10 => MOTOR
Connector to the Motor
J11 =>
Blinker (max. 40W )
J12
AERIAL
Radio Antenna
COM Contacts common unit
PHOT.1 NC
Photocells contact (NC)
J13 => INVERTER Connector for the logic of the INVERTER card (optional)
J14
STOP
OPEN
CLOSE
K BUTT.
A*A
SIGNAL
Contact of the stop button (NC)
Contact of the opening button (NO)
Contact of the closing button (NO)
Contact of a single impulse (NO)
24 Vac accessories power supply
Warning light - gate open 24Vdc
Buzzer
BC07050
Connector for radio receiver 24Vac
Connector for Heater Card
J17 => INVERTER Connector for the INVERTER card power supply (Optional - DO
NOT ALTER THE SAFETY DEVICE ! )
Checking the rotation direction of the motor (ON)
Timing (ON)
Pause time before the automatic closing (ON)
Jogging radio receiver (OFF) - automatic (ON)
Single impulse command (K BUTT) jogging (OFF) - automatic (ON)
Photocells always active (OFF) - Photocells active only on closure (ON)
Encoder for the PLUS model (ON - operated)
Pre-blinking (ON) - Normal blinking (OFF)
Pause time before the automatic pedestrian closing (ON)
Electronic brake (ON-operated)
Gradual start (ON- operated)
230V Motor (OFF) 120V (ON)
TORQUE - ELECTRONIC TORQUE REGULATOR
The torque is regulated by rotating the Trimmer TORQUE, varying the output voltage of
motor ends,(when rotated clockwise, more torque Is transmitted to the motor).
Such torque Is automatically Included 3 seconds after the start of every operating cycle.
This allows the motor to have the maximum pickup when it starts.
ELECTRONIC BRAKE (suggested operation)
If DIP 10 is ON, the system shall brake once the total opening or closing have been
carried out, so to avoid the inertia that would damage the gear In the event of an Impact
against the mechanical stops.
GRADUAL START (suggested operation)
If DIP 11 is ON, a gradual movement is enabled at every operation start.
This function is not active after the encoder or another safety device detects an obstacle.
IMPORTANT SAFETY INSTRUCTIONS
FOR THE INSTALLATION
1° - Install a thermal magnetic switch (omnipolar, with a minimum contact opening of 3
mm) before the control board, in case this is not provided with it. The switch shall be
guaranteed by a mark of compliance with international standards.
2° - As far as the cable section and the cable kind are concerned, RIB suggests to use
an NPI07VVF cable, with a minimum section of 1,5mm2, and to follow, In any case,
the IEC 364 standard and Installation regulations In force In your Country.
N.B.: THE SYSTEM MUST BE GROUNDED
Data described by this manual are only Indicative and RIB reserves to modify them at
any time.
Install the system complying with current standards and regulations.
LED SIGNALS
DL1
DL2
DL3
DL4
DL5
DL6
DL7
DL8
DL9
photocells contact (NC)
stop contact (NC)
opening limit switch contact (NC)
closing limit switch contact (NC)
programming operated
gate on opening “OPEN” (green)
gate on closure “CLOSE” (red)
manual release safety device (NC)
Checking the encoder operation
Pag. 18 di 28
5 - CHECKING THE ROTATION DIRECTION OF THE MOTOR
This control is carried out to facilitate the installation of the system or any possible future
control.
SAFETY ENCODER (KPLUS)
It serves as a safety device both during opening and on closure, with movement
reversion.
DIP 7 (ON) operates the motor with encoder.
If the Encoder does not work (due to a failure In the power supply, disconnected wires,
broken or defective disk), the gate Is not operated.
If the encoder operates the closing or the opening and than gives a reverse command, the
gate stops and reverses Its movement for 1 second. The buzzer buzzes to alarm for 5
minutes and the blinker blinks for 1 minute.
During or after the 5 minutes, when the buzzer alarms, you can make the gate work again
just pressing the operating button you want.
1 - After you positioned the limit switch cams on the rack, (Fig.7 page 4), set Dip1 on
mode ON. The LED DL5 starts blinking.
2 - Press and keep the button PROG. (the gate is now controlled with manned operation:
open-stop-close-stop-open-etc.). THE GREEN LED DL6 “OPEN” turns on and the
gate opens and stops after having reached the limit switch cams. If this does not
happen, release the button and invert the two cables of the motor.
3 - Press the button PROG. and keep it. THE RED LED DL7 “CLOSE” turns on and the
gate closes and stops after it reaches the limit switch cams.
4 - At the end of the control, position DIP1 on mode OFF. The LED DL5 turns off,
signalling you exit from the control.
NB: The encoder and the photocells are not active during this control.
6 - TIMING
K PROGRAMMING WITH ENCODER (K PLUS)
The programming can be carried out regardless of the gate position.
1 - Position the micro switch Dip 2 on mode ON => the LED DL5 emits short blinkings.
2 - Push the button PROG. => the gate opens closes and opens automatically 2 seconds
after It closed. When the opening cycle Is terminated, It stops. Wait as long as you
want the gate to remain open (excluded by DIP3 OFF)
3 - Push the button PROG. to command the gate closing (also the pause time count
before the automatic closing stops - max. 5 minutes).
4 - The gate stops as the closing cam is reached.
5 - WHEN THE TIME PROGRAMMING IS COMPLETED, POSITION DIP 2 ON MODE OFF.
If the INVERTER card is connected to the KPLUS with the KS, the card automatically
controls its slowing-down on approaching and you can also control the operator speed
(read the Instructions enclosed to the INVERTER card).
K PROGRAMMING WITHOUT ENCODER (K)
NB: DIP7 SHALL BE ON MODE OFF!!
This programming is the same as that shown by the previous paragraph.
By connecting the INVERTER card to K with KS, this automatically controls its slowingdown when approaching, and you can also determine the speed of the operating device
(read the instructions enclosed to the INVERTER card).
OPERATION OF THE OPERATING ACCESSORIES
OPENING BUTTON (with timer function)
When the gate is standstill, the button operates the opening mode. If you push this button
when the gate is on closure, It opens again.
TIMER FUNCTION
This function is useful In the rush hours, when vehicle traffic is slow (e.g. entry/exit of
workers, emergencies In residential or parking areas and, temporary, for removals).
APPLICATIONS
By connecting a switch and/or a daily/weekly timer (in place or in parallel with the opening
button N.O. “COM-OPEN”), it is possible to open the automation or to keep It open, as
long as the switch is on or the timer is activated.
When the automation is open, all operating functions are inhibited.
If the automatic closing Is started, by releasing the switch or at the time set before, the
automation immediately closes; if not, you need to operate a command.
CLOSING BUTTON (COM-CLOSE)
When the gate Is standstill, It operates the closing.
JOGGING OPERATION BUTTON (COM-K BUTTON)
If DIP5 is OFF => It cyclically commands open-stop-close-stop-open-etc.
If DIP5 is ON => It opens the gate when this Is closed. If It Is operated while the gate Is
opening, It has no effect. If It Is operated when the gate is open, it closes the gate and, If It
Is operated while the gate Is closing, It opens the gate again.
RADIO TRANSMITTER
If DIP4 is OFF => It cyclically commands open-stop-close-stop-open-etc.
If DIP4 is ON => It opens the gate when this is closed. If It Is operated while the gate Is
opening, It has no effect. If It Is operated when the gate Is open, It closes. If It Is operated
while the gate Is closing, It opens the gate again.
AUTOMATIC CLOSING
Pause times before the automatic closing of the gate are set with the timing procedure.
The maximum pause time Is 5 minutes.
Pause time can be started or stopped by DIP3 (ON started).
PHOTOCELL 1 (COM-PHOT 1))
If DIP 6 is OFF - The gate does not open if there Is an obstacle within the photocells
range of action.
During operation, photocells work both when the gate opens (by starting the opening
movement again after half a second time), and when It closes (by starting the reverse
movement after one second time).
If DIP 6 is ON - If there Is an obstacle within the photocells range of action when the gate
is closed and its opening Is commanded, the gate opens (during Its opening, photocells do
not work).
Photocells work only while the gate Is closing (by starting Its reverse motion after one
second, even if they are still engaged).
STOP BUTTON
The STOP button stops the gate during any operation.
If you push it when the gate is totally open (or partly open, by using the pedestrian
command), this button temporary excludes the automatic closing (if selected by DIP3 and
DIP9). It Is than necessary to operate another command to make the gate close again.
The automatic closing function Is enabled again with the following operating cycle (if
selected by DIP3 and DIP9).
BLINKER
N.B.: This electric board can supply power ONLY TO BLINKERS WITH (ACG7059)
BLINKING CIRCUIT, with max. 40W lamps.
PRE-BLINKING FUNCTION:
- With DIP8 on OFF => the motor, the blinker and the buzzer start at the same time.
- With DIP 8 on ON => the blinker and the buzzer start 3 seconds before the motor.
BUZZER (Optional)
The buzzer emits an intermittent sound signal during opening and closing cycles.
When safety devices are operated (alarm), the intermittence frequency of this sound
signal Increases.
WARNING LIGHT - GATE OPEN (COM-SIGNAL):
Its function Is to signal when the gate Is open, partly open or not totally closed anyway. It
turns off only when the gate Is totally closed.
This warning signal is not enabled during the programming procedures.
N.B.: If you overuse the push button panels or the lamps, the control board logic
system may be compromised, resulting into a possible operation block.
TECHNICAL DATA
- Temperature range
0 ± 70°C
- Moisture
< 95% without condensation
- Power supply voltage
230V~ ±10%
- Frequency
50/60 H
- Max. power consumption of the card
60 mA
- Transient power mains drops
100mS
- Max. capacity of the warning light - gate open 3 W (corresponding to 1 3W lamp or
to 5 LEDS with 2,2 kΩ
resistance In series)
- Max. load at blinker output 40W with resistive load
- Available current for photocells and accessories 0,4 A ±15% 24Vac
- Available current for the radio connector
200mA 12Vdc
- All inputs must be used as clean contacts without being earthed, because power
supplied is generated In the card and is arranged so as to allow for double or reinforced
Insulation with respect to live parts.
All inputs are controlled by a programmed integrated circuit, that carries out a self-control
cycle every time the gate Is operated.
Pag. 19 di 28
OPTIONALS
EXTRA FUNCTIONS WITH EXPANDER (ACG5470)
!! FEED THE EXP CARD IN WHEN POWER IS NOT SUPPLIED !!
LÉGENDE
CAPTION
TR => Adjustment trimmer for the courtesy light time
1-2 => 24Vac power supply for photocells, FOTOOSTA units etc….
3-4 => Traffic light 1 contact
5-6 => Traffic light 2 contact
7-8 => Courtesy light contact
9
=> Photocell 2 contact (NC)
10 => Pedestrian opening command (NO)
11 => Free contact
12 => Common unit
TRAFFIC LIGHT CONTROL
When the gate is closed, the traffic light is turned off.
The red light (3-4) turns on when the gate opens.
The green light (5-6) turns on when the gate is open and the red light turns off.
The green light remains turned on until the automatic closing starts.
When the gate closes, the green light turns off and the red light turns on.
INVERTER CARD (ACG9201)
!! REMOVE THE MOTOR CAPACITOR !!
Connect the motor wires directly to the INVERTER card (lead blue=>terminal U).
The INVERTER allows for => the thrust force adjustment, the gradual start, the
adjustable max. speed, the slowing-down while approaching and the breaking when the
limit switch is reached.
The capacity of K1800 becomes 900Kg/1980lbs.
EXPANDER CARD LED SIGNALS
D2 photocell 2 contact signal
D3 pedestrian contact signal
D4 free
D5 voltage available
N.B.: LED D2 and LED D5 must always be turned on for a correct functioning .
D5
D4
D3
D2
PEDESTRIAN OPENING BUTTON (10-12)
This command operates the partial opening of the gate and Its closing. When the gate Is
partly open, it is not possible to operate its total opening using the pedestrian command.
It is first necessary to close the gate than to open it totally.
It enables exclusively the pedestrian opening and closing following the jogging mode
(open-stop-close-stop-etc...).
LEARNING PROCEDURE FOR THE PEDESTRIAN OPENING
When the gate is closet and the closing limit switch is engaged
1 - First position the DIP2 on mode ON (the LED DL5 blinks quickly) and then DIP1
on mode ON (The LED DL5 blinks slowly).
2 - Press the pedestrian button (10-12) => The sliding gate opens.
3 - Press the pedestrian button to stop the travel (thereby determining the gate opening).
4 - Wait the time you want the gate to remain open (excluded by DIP9 on OFF), then
press the pedestrian button to start the closing.
5 - Position DIP1 and 2 on mode OFF after the closing limit switch has been reached.
Safety devices are active during the programming and their intervention stops it (the LED
blinks no more but remains constantly turned on).
To repeat the programming, position DIP1 and 2 on mode OFF, close the gate and
repeat the procedure described above.
HEATER CARD (ACQ9092)
This device controls the heating of the operating device when this is installed in places
with very low temperatures.
ACG6082 - 433
ACG7026 - 91
AUTOMATIC PEDESTRIAN CLOSING
Pause times before the automatic pedestrian closing of the gate are set during the
programming procedure.
The max. pause time is 5 minutes.
You can start or stop the pause time using DIP9 (ON starts).
PHOTOCELL 2 (9-12)
If it detects an object during the opening cycle, it then operates the closing of the gate at
the end of the interposition. If it detects one during the closing cycle, it then operates the
opening at the end of the interposition.
This function is particularly helpful when you want the gate to close immediately after you
passed it. If it is not used, jumper the terminals 9-12.
COURTESY LIGHT (7-8)
It is possible to supply 24Vac power to the coil of a relay, so as to feed one lamp or more
for a minimum period of 1 second and for a maximum period of 4 minutes (controlled by
the TR trimmer fitted on the EXPANDER card).
The relay is activated at every opening or closing.
When the closing Is finished, the traffic light turned off.
ACG6081 - 433
ACG7025 - 91
RADIO TRANSMITTER MOON
*
*
*
*
MOON 91 (30,925MHz) - 2CH Code ACG7025 - 4CH TX91 Code ACG7026
Ref. Min. Certificate P.T. of EC Inspection N. EMC/98/IST/012
Min. Authorization P.T. DGPGF/SEGR/2/07/336915/FO
EC CERTIFICATE OF COMPLIANCE OF THE KIND
CERTIFICATE OF CONFORMITY (GERMANY)
Pag. 20 di 28
Rack of model 4 with zinc plated angle Irons, in2mt - 6,56 feet bars code: ACS9050
Ideal for gates weighting more than 1,000Kg / 2,200lbs.
RX91/A
RX91/A
RX433/A
RX433/A
RX433/A 2CH
RX433/A 2CH
with code learning system and coupling code ACG5005
with code learning system and terminal board code ACG5004
with code learning system and coupling code ACG5055
with code learning system and terminal board code ACG5056
with code learning system and coupling code ACG5051
with code learning system and terminal board code ACG5052
SPARK ANTENNA
In order to make the systems mentioned above give the best performances, you need to
install an antenna tuned on the frequency of the radio receiver installed.
N.B. Pay attention not to let the central wire of the cable to came Into contact with
the external copper sheath, since this would prevent the antenna from working.
Install the antenna vertically and in such a way the remote control can reach it.
SPARK ANTENNA 91 code. ACG5454
SPARK ANTENNA 433 code. ACG5252
SPARK BLINKER WITH IN-BUILT INTERMITTENT CARD
NYLON OLIVE
ACG4010
FIT SYNCRO PHOTOCELLS for the wall-installation - code:ACG8026
The range you can set Is 15÷30mt 49÷100”
You can fit many couples close together thanks to the synchronising circuit.
Add the SYNCRO TRANSMITTER, code: ACG8028, for more than 2 photocells couples
(up to 4)
COUPLE OF BUILT-IN BOXES FOR THE FIT SYNCRO
code: ACG8051
ACG7059
BLOCK KEY SELECTOR FOR WALL-INSTALLATION
BLOCK KEY SELECTOR TO BUILD-IN
code.:ACG1053
code.:ACG1048
MECHANICAL STRIP L=2MT - 6,56 FEET
code: ACG3010
With double-safety contact, you can cut the length you need.
INSTALLATION KIT for gates weighting up to a 600Kg / 1300lbs
code: ACG4655
7 - FINAL OPERATION
The gasket shall be fitted only at the end of the installation, before you mount
the case.
PLATE TO BE CEMENTED
code: ACG8107
Fit the gasket
The gasket is fitted
NYLON RACK MODULE 4, with zinc plated angle Iron, In 1mt. bars.
Ideal for gates up to 1,000Kg / 2,200lbs weight
code: ACS9000 1mt / 3,28”
code: ACS9001 10mt / 32,8” (1mt/3,28” x 10)
Close the case
Motor ready
Pag. 21 di 28
ANLAGEN LAY-OUT
1
2
3
4
5
6
7
8
9
K1800
Kg
1800
m/sec
0,166
N
4
230V~ 50-60Hz
Fig. 4
640
W
257
A
1,18
Kondensator
µF
12,5
n°
9 - 60s/2s
Kg
db
<70
Betriebstemperatur
°C
-10 ÷ +70°C
IP
54
10,5
D
E
U
T
S
C
H
Pag. 22 di 28
Abmessungen in mm
0,2”
D
E
U
T
S
C
H
Fig. 5
10,6”
ELEKTROANSCHLÜSSE
Pag. 23 di 28
4 - VERBINDUNGEN
J4 => PRI.TRANSF.
J5 =>
J8 => CAPACITOR
J9
LSO
COM.
LSC
J10 => MOTOR
J11 =>
Blinker (max. 40W)
J14
STOP
ÖFFNEN
CLOSE
K BUTT.
A*A
SIGNAL
BC07050
J17 => INVERTER
LED-ANZEIGEN
DL1
DL2
DL3
DL4
DL5
DL6
DL7
DL8
DL9
D
E
U
T
S
C
H
Pag. 24 di 28
D
E
U
T
S
C
H
ACG6082 - 433
ACG7026 - 91
ACG6081 - 433
ACG7025 - 91
*
*
*
*
*
*
*
*
*
*
*
D
E
U
T
S
C
H
Pag. 26 di 28
D
E
U
T
S
C
H
RX91/A
RX91/A
RX433/A
RX433/A
RX433/A 2CH
RX433/A 2CH
TRAGSPUHRHALTER ACG4010
ACG1053
ACG1048
Pag. 27 di 28
I
RIB S.r.l.
25014 Castenedolo - Brescia - Italy
Via Matteotti, 162
Telefono ++39.030.2135811
Fax ++39.030.21358279 - 21358278
http://www.ribind.it - email: [email protected]
F
GB
D
DICHIARAZIONE DI CONFORMITÁ - DECLARATION OF COMPLIANCE
DÉCLARATION DE CONFORMITÉ - ÜBEREINSTIMMNUGSERKLÄRUNG
Dichiariamo sotto la nostra responsabilità che l’operatore K1800 è conforme alle seguenti norme e Direttive
L’opérateur K1800 se conforme aux normes suivantes:
We declare under our responsibility that K1800 operator is conform to the following standards:
Wir erklaeren das der K1800 den folgenden EN-Normen entspricht
EN 55014-1
EN 55014-2
EN 60335-1
EN 60335-2-103
2000
1997
2002
200X
EN 61000-3-2
EN 61000-3-3
EN 61000-6-1
EN 61000-6-2
2000
1995
2001
1999
EN 61000-6-3
EN 61000-6-4
2001
2001
Inoltre permette un’installazione a Norme - Permit, en plus, une installation selon les normes suivants
You can also install according to the following rules - Desweiteren genehmigt es eine Installation der folgenden Normen:
EN12453
2000
EN 12445
2002
EN 13241-1
2003
Come richiesto dalle seguenti Direttive - Conformément aux Directives
As is provided by the following Directives - Wie es die folgenden Richtlinien verfügen
93/68/EEC
73/23/EEC
89/336/EEC
92/31/EC
93/68/EEC
Il presente prodotto non può funzionare in modo indipendente ed è destinato ad essere incorporato in un impianto costituito da ulteriori elementi.
Rientra perciò nell’Art. 4 paragrafo 2 della Direttiva 98/37/CEE (Macchine) e successive modifiche, per cui segnaliamo il divieto di messa in
servizio prima che l’impianto sia stato dichiarato conforme alle disposizioni della Direttiva
Le présent dispositif ne peut fonctionner de manière indépendante, étant prévu pour être intégré à une installation constituée d'autres éléments.
Aussi rentre-t-il dans le champ d'application de l'art. 4, paragraphe 2 de la Directive machines 98/37/CEE et de ses modifications successives. Sa
mise en service est interdite avant que l'installation ait été déclarée conforme aux dispositions prévues par la Directive
This product can not work alone and was designed to be fitted into a system made up of various other elements. Hence, it falls within Article 4,
Paragraph 2 of the EC-Directive 98/37 (Machines) and following modifications, to which respect we point out the ban on its putting into service
before being found compliant with what is provided by the Directive
Dieses Produkt kann nicht allein funktionieren und wurde konstruiert, um in einen von anderen Bestandteilen zusammengesetzten System
eingebaut zu werden. Das Produkt fällt deswegen unter Artikel 4, Paragraph 2 der EWG-Richtlinie 98/37 (Maschinen) und folgenden
- Per la redazione del fascicolo tecnico di installazione nel rispetto della Direttiva Macchine 98/37/CEE, l’installatore può usufruire della
modulistica predisposta da RIB e scaricabile all'indirizzo internet http://www.ribind.it/exe/ribtec.exe
- Pour la redaction du présente notice technique d'installation a été rédigée dans le respect de la Directive Machines 98/37/CEE. Les formulaires RIB
sont à la disposition de l'utilisateur, ils peuvent être déchargés depuis le site http://www.ribind.it/exe/ribtecfr.exe
- For the editing of the technical installation brochure in compliance with the Machine Directive 98/37/CEE, the installer can avail himself of the
forms prepared by RIB, that can also be downloaded from the internet address: http//www.ribind.it/exe/ribtecen.exe
- Zur Verfassung der technischen Installationsbroschüre laut der Maschinenrichtlinie 98/37/CEE verfügt der Installateur über die von der Firma RIB
ausgestellten Vordrucke, die auch von dem Internet unter der Adresse http//www.ribind.it/exe/ribtecde.exe downloadet werden können.
Pag. 28 di 28
K1800
BA01019
BA03015
CAL1120
CAL1125
CAL1126
CCM6204ZZ
Cond. 12,5µF 450V per K1800 230/50
Microswitch
Passacavo IP55 GW50431 AC50
Passacavo IP55 GW50429 AC
Trasformatore toroidale 20VA 230V
CFS1004
CME2025
CME2026
CME2028
CME2036
CMO1188
Motore K1800 230V - 50/60Hz
CTC1012
CTC1018
CTC1152
CTC1164
CTC1205
CTC1221
CTC1242
CTC1243
CTC1245
CTC1259
CTC1259
CTC1308
CTC1355
CTC1406
CVA1325
CVA1372
® 25014 CASTENEDOLO (BS)-ITALY
Via Matteotti, 162
Telefono ++39.030.2135811
Telefax ++39.030.21358279-21358278
automatismi per cancelli
automatic entry systems http://www.ribind.it - e-mail: [email protected]
Cod. CVA1532 - 26062003 - Rev. 01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement

Languages

Only pages of the document in English were displayed