199245 Operating Manual:CMPT-10266-0109 10/28/09 5:16 PM Page 1 ENTERAL DELIVERY SYSTEM Operating Instructions For Model Number 9522041 / 199245 COMPAT SelectFlo® Enteral Delivery Pump and Memory SYSTÈME D’ALIMENTATION ENTÉRALE SISTEMA DE ADMINISTRACIÓN ENTERAL 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:16 PM Page 1 1 Table of Contents Índice MC COMPAT SelectFlo Enteral Delivery Pump NOT FOR PARENTERAL USE INTENDED EXCLUSIVELY FOR ENTERAL TUBE FEEDING FORMULAS. NE PAS UTILISER POUR L’ALIMENTATION PARENTÉRALE À UTILISER EXCLUSIVEMENT AVEC LES PRÉPARATIONS POUR ALIMENTATION ENTÉRALE PAR SONDE. ® Section Page Introduction Controls Operating Instructions Alarms/Indicators Troubleshooting Specifications Symbols on Pumps and Accessories Self Test Factory Service Safety and Warnings Limited Warranty Cleaning COMPAT® Enteral Delivery System 3 4 6 9 10 11 12 13 13 13 14 14 15 For More Information Contact your local Nestlé HealthCare Nutrition Sales Representative or call Customer Service from anywhere in the U.S. and Canada 1-877-338-4238. Monday–Friday 8:00 a.m.–4:30 p.m. Central Standard Time Pump is not intended for neonatal use. Caution: Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner. Page 16 17 19 22 23 24 25 26 26 25 27 27 28 Página 29 30 32 35 36 37 38 39 39 39 40 40 41 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:16 PM Page 2 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:16 PM Page 3 Introduction 3 The COMPAT SelectFlo® Enteral Delivery Pump is an easy to use, portable pump for the administration of all enteral feeding solutions. Key features of this device include: • Latched Door Reduces the likelihood of accidental dislodgement of sets and enables immediate detection of a free flow condition. • Ease of Maintenance The fire resistant plastic case and sealed control panel prevent fluid leakage and allow cleaning with any mild soap. • Automatic Priming Frees up nurse to perform other bedside duties. • Easily Understood Alarms Low Battery, Set Error and Flow Error for detecting empty container or occluded line. • Ease of Use Feeding parameters are easily displayed. • Versatility Formula Rate adjustable in 1 mL/hr increments from 1–295. • Lightweight and Portable The unit is 5.1 pounds, and can clamp to any IV pole. • 2 1/2 Minute Hold Alarm • Low Occlusion Pressure 20 p.s.i. maximum occlusion allows for safe use with any enteral feeding tube. • Volume Delivered For ease of tracking what has been administered when continuous feeding is desired, or over several feedings when intermittent feeding is necessary. • Memory Retention of Infusion Rate and Volume Delivered even after unit is turned off. Settings are automatically recalled when the pump is turned back on. • Adjustable Alarm Volume • Built-in Pole Clamp • Luer Adapter Cap Holder • Serviceability Self-diagnostic mode allows for complete circuitry check when the pump is turned on. 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:16 PM Page 4 Controls Keypad Controls Function Indicator Displays 1. ON, applies power to unit. 9. 2. OFF, turns power off except to battery charger. 3. VOL. DEL., press to display volume of formula delivered. 4. CLEAR, clears volume delivered to “0”. 5. p increases flow rate when pressed and held. 11. LOW BAT, indicates when the battery charge is below performance level. 6. q decreases flow rate when pressed and held. 12. Display panel, indicates selected parameter. 7. FILL, automatically fills the administration set with formula. 8. START/STOP, alternately starts and stops the pump and silences the alarm. 12 9 10 11 13 14 1 7 3 5 4 6 2 8 4 RUNNING/STOPPED, green RUNNING light indicates the pump is delivering formula. Red STOPPED light indicates the pump is stopped. 10. AC, indicates the unit is plugged into an AC outlet. 13. RATE, green RATE light indicates that the number in the display panel is the feeding rate. 14. VOLUME DELIVERED, green VOLUME DELIVERED light indicates that the number in the display is the amount of formula delivered. 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 5 Controls (cont.) 5 15. Flow Sensors and Drip Chamber Guide 19 16. Tubing Guide 17. Drip Chamber Brackets 18. Rotary Peristaltic Pump Mechanism 15 16 25 24 19. Door Latch 20. Door 17 21. Luer Adapter Cap Holder 22. Power Cord 23 18 24. Pole Clamp 21 20 23. Alarm Volume Control 22 25. Directions (side panel also) 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 6 Operating Instructions DIAGRAM 1 Open pump door by pushing, then pulling door latch, insert pump set drip chamber into drip chamber bracket. DIAGRAM 2 Assemble silicone tubing around rotor. DIAGRAM 3 Insert pump adapter into bridge and place tubing into tubing guide. Close door. 6 DIAGRAM 4 Press ON to activate pump. Press p (FASTER) or q (SLOWER) until the desired setting is displayed. Clear Volume Delivered if necessary. 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 7 7 Operating Instructions (cont.) Plug power cord into a 120 VAC, 60 Hz. three wire grounded outlet. Assemble Delivery Set 1. Open pump door by pushing/pulling door latch. 2. Prepare and hang the delivery set from an IV pole. 3. Insert delivery set drip chamber into drip chamber guide (roller clamp should be closed) (Diagram 1). 4. Assemble silicone tubing around the rotor (Diagram 2). DIAGRAM 5 Completely assembled pump set. 5. Insert pump adapter into bridge and place tubing into tubing guide (Diagram 3). 6. Close pump door. Check Pump Settings 1. Press ON—alarm will sound .... briefly and display 8 8 8 8. The pump has memory, and will scroll through the parameters and display the previous settings. It will return to flashing the Infusion Rate (Diagram 4). 2. Check the Infusion Rate. To change, press p (FASTER) or q (SLOWER) until desired rate is displayed. 3. Check Volume Delivered. Press VOL DEL. until Volume Delivered is indicated on the display panel. If desired, this can be reset to zero by pressing CLEAR. Auto Filling 1. Open the roller clamp on the SelectFlo delivery set. Remove the luer adapter cap from the delivery set, and place the cap in the luer adapter cap holder available on the pump. 2. Press the FILL key for automatic priming of the delivery set. The display will show the word FILL, and the rotor will begin to turn to indicate the unit is priming. Fill the entire line. The prime cycle takes approximately 2 minutes. The pump will audibly alarm and flash the infusion rate when filling is complete. (Note: Automatic filling may result in a small amount of formula being expelled beyond the luer adapter on the delivery set.) Gravity Fill 1. Follow steps 1–3 listed under Assemble Delivery Set. 2. Next, remove adapter cap from the delivery set, and place the cap in the adapter holder available on the pump. Open the roller clamp and fill the entire line with formula. Close the roller clamp. 3. Proceed to steps 4–6 under Assemble Delivery Set. 4. Complete steps 1–3 under Check Pump Settings. Begin Feeding 1. Connect the delivery set to the patient’s feeding tube. 2. Press START/STOP to start the pump. 3. OFF will turn off the pump at any time (Infusion Rate and Volume Delivered are retained). 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 8 Operating Instructions (cont.) How to Modify Pump Settings To change the Infusion Rate To clear Volume Delivered 1. Press START/STOP to stop the pump. Volume Delivered is primarily intended to monitor formula delivered when intermittent feedings are required. 2. Enter a new infusion rate by pressing p (increase) or q (decrease) until the desired rate is displayed. 1. Press START/STOP to stop the pump if running. 2. Press VOL DEL until Volume Delivered light is lit. 3. Press CLEAR. 8 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 9 9 Alarms/Indicators Note AC Flow Error (FLO Err) Pressing the START/ STOP key after the alarm condition is identified will silence the alarm and return pump to hold mode. Indicates the pump is operating on electrical power. The pump should be left plugged into an AC outlet whenever practical. No audible alarm will sound. Under these conditions the pump stops, an alarm sounds and is displayed as ‘FLO Err’. One of the following conditions may apply: Corrective Action Possible Condition 1. Refill container or start new 1. Feeding container is empty administration set 2. An occlusion has caused delivery to stop 2. Identify point of occlusion 3. Drip chamber is overfilled 3. Insert new administration set 4. Drip chamber walls are 4. Manipulate chamber to clear severely coated with formula drops in sensor path 5. Sensors in drip chamber 5. Clean sensor with bracket need cleaning isopropyl alcohol 6. Drip chamber is improperly 6. Reposition drip chamber placed Running/Stopped Indicates the status of the pump. Low Battery (LOW BAT) This is activated when the battery is run down. After 15 minutes, this light will flash, an audible alarm will sound and the pump will stop. Whenever the LOW BAT light is on, the pump should be plugged into an AC outlet, and normal feeding may continue. To avoid degrading battery life it is important not to run down the battery. The battery recharges anytime the pump is connected to an AC outlet, regardless of whether the pump is running. No Set (no SEt) Hold error (hoLd Err) If the door is not closed and latched securely, no set is loaded on the pump, or a proper COMPAT SelectFlo® set is not used, the alarm message ‘no SEt’ will be displayed. Correct by loading an appropriate COMPAT SelectFlo delivery set, close and latch the door, and press START/STOP. If pump is left on hold and START/ STOP is not pressed within 2 1/2 minutes, this alarm will be activated and ‘hoLd Err’ will be displayed. Press START/STOP button twice to extend the hold for another 2 1/2 minutes; or press once to restart the feeding pump. 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 10 Troubleshooting COMPAT® Enteral Delivery Pumps are reliable electromechanical devices. As with any mechanical device, problems may occur. The following tips will help you correct the minor in-service problems that may arise. SITUATION 10 TROUBLESHOOTING GUIDE POSSIBLE CAUSE SOLUTION • Low battery • Battery charge is below alarm activated performance level • Plug cord into AC outlet • (LOW BAT) illuminated • (FLO Err) • Feeding container is empty • Replace or refill feeding container • Occlusion is restricting flow • Identify point of occlusion and free up - Pump Set • kinked tubing • blocked tubing • closed roller clamp - Feeding tube - Feeding container • Drip chamber not properly placed in pump • Reposition drip chamber • Drip chamber walls coated with formula drops or condensation in sensor path • Manipulate chamber to clear drops or condensation in sensor path • Flow sensors housing need cleaning • Clean with cotton swab dampened with isopropyl alcohol alarm activated • (hold Err) Pump • Pump is on hold for more is left on hold than 2 1/2 minutes • Press START/STOP button • (No SEt) Alarm • Door not closed and latched activated • Examine tubing for proper placement, close door • Wrong set is used • Load an appropriate set •Set is not properly in place • Assemble tubing properly around pump rotor. Close and latch door 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 11 11 Specif ications Type of Device . . . . . . . . . . . . . . . Mechanism . . . . . . . . . . . . . . . . . . . Infusion Rate . . . . . . . . . . . . . . . . Accuracy . . . . . . . . . . . . . . . . . . . . . Occlusion Pressure . . . . . . . . . . Battery . . . . . . . . . . . . . . . . . . . . . . . ....................... ....................... ....................... ....................... ....................... ....................... ....................... ....................... Dimension . . . . . . . . . . . . . . . . . . . Weight . . . . . . . . . . . . . . . . . . . . . . . . Case Material . . . . . . . . . . . . . . . . Power Requirement . . . . . . . . . Operating Temperature . . . . . ............................... Storage Temperature . . . . . . . . ............................... Volumetric enteral feeding pump Rotary Peristaltic 1–295 mL/hr in 1 mL increments ± 10% of selected flow rate Does not exceed 20 p.s.i. Sealed lead acid Rechargeable Automatically recharges when connected to an AC outlet Recharge time is 12 hours from complete discharge to full recharge Operating time is 10 hours at 100 mL/hour (fully charged battery) (Charge unit fully every 6 months) 6.4" High x 6.4" Wide x 5.0" Deep 5.1 pounds Fire and impact resistant plastic 120V , 187 mA, 60 Hz 10o– 40oC (50o– 104oF) 75% R.H. non-condensing 0o– 50oC (32o– 122oF) 95% R.H. non-condensing Type of Protection Against Electrical Shock ...................... Class 1, Internally Powered Equipment Degree of Protection Against Electrical Shock .................... Type BF Degree of Protection Against Ingress of Fluids .................... Ordinary Equipment – IPX0 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 12 Symbols on Pump and Accessories 12 The following symbols may be found on the pump: Refer to Accompanying Documents Alternating Current Type BF Protection (degree of protection against electrical shock—there is no conductive connection to the patient) Medical Electrical Equipment 1) Classified with respect to electrical shock, fire and mechanical hazards in accordance with UL60601-1 2) Classified with respect to electrical shock, fire, mechanical and other specified hazards in accordance with CAN/CSA C22.2 No. 601.1 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 13 13 Self Test The major functions of the pump may be tested by the following steps: 1. Turn the pump on by pressing the ON key. .... 2. 8 8 8 8 will be displayed immediately. While this is displayed, press and simultaneously hold the p and q keys for 4 seconds. 3. After 4 seconds, an audible alarm will sound, and the screen will display ‘teSt’ momentarily, and .... then all eights ( 8 8 8 8). 4. The pump rotor should begin to turn. To test the visual alarms, press either CLEAR, p, q, FILL, VOL DEL, or START/STOP. When any of these keys are pressed or the sensor is momentarily blocked, all visual alarm indicators should light, an audible alarm will sound, and the rotor will halt momentarily. 5. Any failure indicates a service check should be performed. See the Factory Service section for instructions on where to send the pump. 6. Turn the pump off by pressing the OFF key. Factory Service In the event a pump requires servicing, contact your Nestlé HealthCare Nutrition Sales Representative or call Customer Service for instructions from anywhere in the U.S. and Canada at 1-877-338-4238. All service work should be performed by authorized personnel only. Unauthorized repairs void warranty (see section on limited warranty). Safety and Warnings NOT FOR PARENTERAL USE INTENDED EXCLUSIVELY FOR ENTERAL TUBE FEEDING FORMULAS. Do not use this device near flammable anesthetics, it is a possible explosion hazard. This device is designed to minimize the effects of uncontrolled electromagnetic interference and other types of interference from external sources. Avoid use of other equipment that may cause erratic operation or degradation in the perfor- mance of this device. If the integrity of the external protective conductor in the installation is in doubt, equipment shall be operated from its internal electrical power source. 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 14 14 Limited Warranty Nestlé HealthCare Nutrition warrants the COMPAT® Enteral Feeding Pump against defects in material and workmanship under normal use and service for a period of one (1) year from date of delivery. This warranty is valid only to the original purchaser and does not extend to any product or part thereof which has been subjected to accident, abuse, alteration, misuse, or which has not been operated and maintained in accordance with prescribed instructions. This warranty shall not apply if the product has been repaired by anyone other than an authorized service representative of Nestlé HealthCare Nutrition. Nestlé HealthCare Nutrition reserves the right to repair or replace (at its option) any pump which fails to meet the foregoing warranty. This warranty is in lieu of all other warranties expressed or implied including, without limitation, warranties of merchantability and of fitness for a particular purpose. Cleaning Caution Disinfecting Always disconnect the pump from the AC outlet before cleaning to avoid electric shock hazard. If it is necessary to disinfect the entire pump, the following is recommended: Using a cloth or sponge, clean the pump housing and rotor regularly with warm soapy water. (Prolonged exposure to alcohol, household detergents or strong cleansers can result in damage to pump housing.) Clean drip sensors with cotton swabs and isopropyl alcohol. General Disinfectants Cidex® pHisohex® Hibiclens® Isopropyl alcohol AIDS and Hepatitis Disinfectants 10% concentration of 5.25% sodium hypochlorite (household bleach) Tuberculosis Disinfectants 70% concentration of isopropyl alcohol After application of these disinfecting agents, allow to air dry. It should be noted that these recommendations should not be substituted for official procedures that may differ among institutions. To determine the proper procedure in a particular institution, contact the Infection Control Department. Do not autoclave. Do not immerse pump in cleaning solutions. Delivery sets are for single use only. Do not clean and reuse. Cidex®, pHisohex® and Hibiclens® are trademarks of their respective companies 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 15 15 COMPAT ® Enteral Delivery System COMPAT ® Pumps 9517455 / 199235 9522041 / 199245 9521437 / 199255 Compat® Enteral Delivery Pump with Dose Limit Compat SelectFlo® Portable Pump featuring Latched Door Compat DualFlo® Enteral Delivery Pump with Hydration Feature COMPAT ® Delivery Sets Gravity Sets 9516074 / 199216 1000 mL Twist Cap Vinyl Bag with Gravity Set For use with the 9517455 / 199235 Compat® pump and 9522041 / 199245 Compat SelectFlo® pump 9521433 / 199507 Pump Set with in line “Y” Adapter and Piercing Spike 9519810 / 199547 Pump Set with in line “Y” Adapter and 1000 mL Vinyl Bag 9519805 / 199312 500 mL Baggle Semi-Rigid Container with Pump Set 9522610 / 199707 SpikeRight™ Piercing Spike with in line “Y” Adapter and preattached Pump Set For use with the 9521437 / 199255 Compat DualFlo® pump 9521429 / 199407 DualFlo Piercing Spike and 1000 mL Vinyl Water Bag 9521430 / 199447 DualFlo 1000 mL Formula Vinyl Bag and 1000 mL Vinyl Water Bag 9521434 / 199607 DualFlo with SpikeRight™ Piercing Spike and 1000mL Vinyl Water Bag For More Information Call your Nestlé HealthCare Nutrition Sales Representative or Customer Service at 1-877-338-4238. 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 16 Introduction 16 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 17 17 1. 9. 2. 3. 4. 5. 12 9 10 11 13 6. 7. 14 1 7 3 5 4 6 2 8. 8 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 18 18 15 16 25 24 17 20. Porte 23 18 21 20 22 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 19 19 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 20 20 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 21 21 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 22 22 AC 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 23 23 GUIDE DE DÉPANNAGE Situation • Installez un dispositif approprié 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 24 24 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 25 25 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 26 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 27 27 Nettoyage Attention 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 28 28 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 29 29 • Alarma de espera de 2 1/2 Minutos 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 30 1. 9. 2. 3. VOL. DEL. (Volumen administrado), al presionarlo se visualiza el volumen administrado de fórmula. 12 9 10 11 4. CLEAR (Borrar), borra el volumen administrado y lo vuelve a “0.” 5. 13 14 1 6. 7. 8. 7 3 5 4 6 2 30 8 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 31 Controles (cont.) 31 15 16 25 24 17 23 18 21 20 22 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 32 32 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 33 33 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 34 1. Presione START/STOP para detener la bomba. 34 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 35 35 Nota AC Falta de equipo (no SEt) 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 36 36 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 37 37 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 38 38 Corriente alterna 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 39 39 Seguridad y advertencias NO APTA PARA USO PARENTERAL PARA USO EXCLUSIVO CON FÓRMULAS DE ALIMENTACIÓN ENTERAL POR SONDAS. 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 40 40 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 41 41 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 42 199245 Operating Manual:CMPT-10266-0109 10/28/09 5:17 PM Page 43 Nestlé HealthCare Nutrition, Inc. Minnetonka, MN 55343-9420 USA U.S. Toll Free 1-877-DEVICE-8 www.nestlenutrition.com/us Except as noted, trademarks are owned by Société des Produits Nestlé, S.A., Vevey, Switzerland. CMPT-10266-0909 SN1027 REV. E
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project