RADSON Tempco Digital 51022 User manual
Add to My manuals46 Pages
RADSON Tempco Digital 51022 is a wired digital thermostat designed to control underfloor heating and cooling systems. With its user-friendly interface and advanced features, it offers precise temperature control and energy efficiency for your home comfort. This thermostat is equipped with an amber backlight for easy visibility, and its silent operation ensures a peaceful environment. Whether you want to set a specific comfort temperature or adjust it on the fly, the RADSON Tempco Digital 51022 provides a convenient and intuitive user experience.
advertisement
▼
Scroll to page 2
of
46
![RADSON Tempco Digital 51022 User manual | Manualzz RADSON Tempco Digital 51022 User manual | Manualzz](http://s3.manualzz.com/store/data/056043135_1-e090c8e53cb8789d00e240c898992df1-360x466.png)
DIGITAL 230V -230V 24V DIGITAL GB Digital thermostat 230V 3 -12 F Thermostat digital 230V 13 -24 D 25 -35 Gebruiksaanwijzing Nl UFH – 230VAC Digitale thermostaat Instrukcja Użytkowania 36-46 Pl 230VAC Termostat z wyświetlaczem Manualul utilizatorului 47-57 Ro Termostat digital UFH – 230VAC 58-68 Инструкция по эксплуатации UFH0051002 – 230VAC Термостат с дисплеем 1 Ru 69-80 2 Installation and Operation Manual IMPORTANT! Before starting work the installer should carefully read this Installation & Operation Manual, and make sure all instructions contained therein are understood and observed. - The Main zone digital programmer should be mounted, operated and maintained by specially trained personnel only. Personnel in the course of training are only allowed to handle the product under the supervision of an experienced fitter. Subject to observation of the above terms, the manufacture shall assume the liability for the equipment as provided by legal stipulations. - All instructions in this Installation & Operation manual should be observed when working with the controller. Any other application shall not comply with the regulations. The manufacturer shall not be liable in case of incompetent use of the control. Any modifications and amendments are not allowed for safety reasons. The maintenance may be performed by service shops approved by the manufacturer only. - The functionality of the controller depends on the model and equipment. This installation leaflet is part of the product and has to be obtained. APPLICATION - The Main zone digital programmer is developed to control and manage all installations of water floor heating and cooling equipped with our UFH range thermostat. The temperature in each room is managed the control of actuators mounting on the manifold. - The controller is normally used in conjunction with a complete connecting box “UFH-MASTER” with or without “Heating & Cooling module” to connect all electrical & hydraulic components of the installation like a circulation pump, actuators... - The controllers have been designed for use in residential rooms, office spaces and industrial facilities. Verify that the installation complies with existing regulations before operation to ensure proper use of the installation. SAFETY INSTRUCTIONS Before starting work disconnect power supply! - All installation and wiring work related to the controller must be carried out only when de-energized. The appliance should be connected and commissioned by qualified personnel only. Make sure to adhere to valid safety regulations. - The connecting boxes are neither splash- nor drip-proof. Therefore, they must be mounted at a dry place. - Do not interchange the connections of the thermostats and the 230V connections under any circumstances! Interchanging these connections may result in life endangering electrical hazards or the destruction of the appliance and the connected sensors and other appliances. 3 1 User Guide UFH – 230VAC Digital thermostat Wired Digital thermostat (230VAC) specially designed to control your Under Floor Heating and cooling managed by actuator. Flush Mounting version, standard fixing with 60mm axes. Pilot wire for NSB function (-2°C) Possibility to regulate on: o Air sensor only o Floor sensor only o Air & Floor combined with different possibilities Amber Backlight Temporary override function (2H) Silent (Triac output), - Optional external sensor 10K at 25°C 2 Technical characteristics Measured temperature precision 0.1°C Operating temperature 0°C - 50°C Setting temperature range 5°C - 35°C by 0.5°C step Regulation characteristics hysteresis (ON/OFF) or adjustable Proportional Integral (PWM) Electrical Protection Class II - IP30 Power Supply Consumption 230VAC 50Hz ~ 3,5W TRIAC 230VAC 75W Max (4 actuators) Displayed during the init (after power supplying) 1.x x Output Software version 4 3 Presentation 1 2 3 4 10 5 6 0 7 B A C 1: 2: 3: 4: 5: 6: 7: 10: Water circulation in the room. Key lock function. Parameters menu. Parameters number or sensor message indication. Sensor used indication Ambient, setting temperature or parameter if 3 displayed. Heating or cooling mode indication. Operating mode. (The active mode is framed) A: B: C: Minus key. (-) Validation key or Mode key. (OK) Plus key. (+) 5 4 How to use your thermostat Use the (OK) key to change the mode in the Operating mode menu OFF mode: (Manual mode) Use this mode if you want to stop the Heating or Cooling function in the room. The ambient temperature will be displayed all the time. Press once on the (OK) to turn on the backlight only and a second time to change the operating mode. Simple installation without main zone programmer: The antifreeze temperature (7°C) will be maintained in the room all the time. Installation with main zone programmer: (with or without Heating and Cooling function) In heating mode: (Winter) The antifreeze temperature (7°C) will be maintained in the room all the time. In cooling mode: (Summer) The thermostat will be switched Off. COMFORT operating mode: (Manual mode) By pressing the keys (-) or (+), the actual comfort setting temperature is now displayed, then press the desired key 1 sec to start the increment or decrement of the setting temperature. The ambient room temperature reappears after a few seconds. Press once on the (OK) to turn on the backlight only and a second time to change operating the mode. The comfort temperature will be followed all the time in accordance with these descriptions: Simple installation without main zone programmer: The comfort temperature will be followed all the time. (Default setting 20°C) Installation with main zone programmer: (with or without Heating and Cooling function) Your thermostat is equipped with 2 comfort settings temperature (1 for heating and 1 for cooling) 6 In heating mode: (Winter) The comfort temperature will be followed all the time. (Default setting 20°C) You can adjust this setting only when the system will work in heating mode. In cooling mode: (Summer) The comfort temperature will be followed all the time. (Default setting 22°C) You can adjust this setting only when the system will work in cooling mode. REDUCED operating mode: (Manual mode) By pressing the keys (-) or (+), the actual reduced setting temperature is now displayed, then press the desired key 1 sec to start the increment or decrement of the setting temperature. The ambient room temperature reappears after a few seconds. Press once on the (OK) to turn on the backlight only and a second time to change operating the mode. The reduced temperature will be followed all the time in accordance with these descriptions: Simple installation without main zone programmer: The reduced temperature will be followed all the time. (Default setting 18°C) Installation with main zone programmer: (with or without Heating and Cooling function) Your thermostat is equipped with 2 reduced settings temperature (1 for heating and 1 for cooling) In heating mode: (Winter) The reduced temperature will be followed all the time. (Default setting 18°C) You can adjust this setting only when the system will work in heating mode. In cooling mode: (Summer) The reduced temperature will be followed all the time. (Default setting 24°C) You can adjust this setting only when the system will work in cooling mode. 7 Automatic operating mode: Simple installation without main zone programmer: The comfort temperature will be maintained in the room all the time. Installation with main zone programmer: (with or without Heating and Cooling function) In this mode your thermostat will follow the program (Comfort or reduced) and order (Heating, cooling, Anti freeze, holiday…) of the main zone programmer. The ambient temperature will be displayed all the time. Press once on the (OK) to turn on the backlight only and a second time to change the operating mode. Override mode: Use this mode to override the automatic mode during 2 hours. You can choose another setting temperature for this duration. By pressing the keys (-) or (+), the override setting temperature is now displayed, then press the desired key 1 sec to start the increment or decrement of the setting temperature. When the duration is finished the thermostat will come back in Automatic mode . The ambient temperature will be displayed all the time. Press once on the (OK) to turn on the backlight only and a second time to change operating the mode. Lock and unlock keypads: Use this function to avoid change on your thermostat. (Available in all modes) - To lock the keypad, maintains the keys (-) & (+) pressed and press the (OK) key in the same time, then the symbol “ “appears. - To unlock the key pads repeat this procedure, (the symbol “ will disappear) “ Sensor messages: Main errors: (the regulation will be stopped) Error on the internal sensor => Err in position “6” in the display with the logo blinks. Error on the External (Floor) sensor display with the => Err in position “6” in the logo blinks. 8 Indications: Error on the limiter (floor) sensor display with the => Err in position “4” in the logo blinks. Lower limitation (floor sensor) display with the => Lo in position “4” in the logo blinks. Higher limitation (floor sensor) display with the => Hi in position “4” in the logo blinks. Special display: If your installation works with a main zone programmer, the residual humidity is monitored, to avoid risk of residual humidity in the house. If the residual humidity is detected in cooling mode the thermostat will be advised to active the dry function. During the dry function the thermostat will stop the water circulation on the room. The cooling logo will be blink to show the function. 5 Installation parameters menu Your thermostat has 1 advanced installer menus. - In order to enter in this menu, use the (OK) key and go to the automatic mode 5 sec. , then press the (-) & (+) in the same time during - The first parameter is displayed 01 “Deg”. How to change the value of a parameter: - Once the parameter is displayed, press the (OK) key to start to blink the value, then you can adjust it with (-) or (+) keys. Press (OK) or wait few seconds to valid your adjustments. To exit the parameter menu, go to the parameter number 09 “End” and press (OK). 9 Parameters N° 00 Names XXx 01 Deg 02 Out 03 04 Sen AiC FlC Other possibility Sofware version Type of degrees displayed Actuator type Selection of the sensor which will be used for the regulation. The listing of the following parameters will be different in function of this parameter. Calibration of the internal sensor (The calibration must be done after 12Hours working with the same setting temperature) Calibration of the Floor sensor 05 Default setting (The calibration must be done after 12Hours working with the same setting temperature) °C: Celsius degrees. °F: Fahrenheit degrees. NC: Normally closed actuator. NO: Normally open actuator. Air: ambient sensor only Flr: External (floor) sensor only. FL.1: ambient sensor with lower and upper floor limitation. FL.2: ambient sensor with intelligent lower floor limitation. - To check the temperature in the room, put a thermometer at 1.5M distance to the floor in the concerned room and wait 1 hour to be sure that the thermometer show the correct temperature. Then you can enter the value saw on the thermometer with (-) or (+) keys. - When a calibration is made the message “Yes” will be displayed. - To erase the calibration press simultaneity (-) and (+) keys when “Yes” is displayed. Now the message “no” should be displayed. The calibration must be done same as described above if the external sensor is connected and used like an external ambiance sensor. If the external sensor is used as floor sensor, the thermometer should be put on the floor. 10 FLl 06 FLo 07 08 09 FLh Cld End Lower limitation of the floor temperature. Only effective if the parameter 02 is adjusted on (FLr or Fl.1) Offset added or subtracted to the actual setting temperature, to define the value of the lower floor limitation. Only effective if the parameter 02 is adjusted on (FL.2) Example: Comfort (Day) setting: 20°C Reduced (Night) setting: 18°C Floor limitation offset: -1°C Upper limit of the floor temperature. Only effective if the external sensor is connected and selected. (FLr or FL.1) Cooling function in the room. Example: Cooling function should be deactivated for room with residual humidity (Bathroom, kitchen...) Default: 18°C Adjustable: From 5°C to ”FLh” Default: 0°C Adjustable: From - 5°C to + 5°C Example: Value of the lower limitation during the day: 19°C Value of the lower limitation during the Night: 17°C Default: 35°C Adjustable: From ”FLl” to 50°C Yes: Cooling function is activated no: Cooling function is deactivated Press (OK) on this parameter to exit the parameters menu end come back to the main display. 11 6 Notes _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ 12 13 14 Protection Class II - IP30 Alimentation Consommation Sortie Version logiciel 15 10 5 6 0 7 B A C A: B: C: 16 18 clignotant. clignotant. 19 er 20 N° Noms 00 XXx Version logiciel 01 Deg 02 Out 03 04 Sen AiC 21 N° Noms 05 FLC FLl 06 FLo 22 N° Names 07 FLh 08 Cld 09 End 23 6 Notes _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ 24 und die 25 o o o 0.1°C Betriebstemperatur 0°C - 50°C Regelungsart Class II - IP30 Software Version 26 10 5 6 0 7 B A C 1: 2: 3: 4: 5: 6: 7: 10: A: B: C: 27 blinkt blinkt blinkt 30 31 Nr. 00 Name XXx 01 Deg 02 Out 03 Sen 04 AiC 32 Nr. Name 05 FlC FLl 06 FLo 33 Nr. Name 07 FLh 08 Cld 09 End 34 Inbouwversie met standaard 60 mm as aansluiting. - o o o - Parti afwijking (2H) - - - Externe voeler in optie10K à 25°C 2 Technische kenmerken Meetnauwkeurigheid 0.1°C Werkingstemperatuur Omgevingstemperatuur instelling 0°C - 50°C hystérèse (ON/OFF) of proportioneel integraal (PWM) Class II - IP30 Voedingsspanning Vermogen Uitgang Software versie 5°C - 35°C by 0.5°C step 37 3 Indicatie 1 2 3 4 10 5 6 0 7 B A C 38 40 knippert. knippert. 41 42 Parameters N° Noms 01 Deg 02 Out 03 Sen 04 AiC 43 Parameters N° Noms 05 FLC FLl 06 FLo Fabrieksinstellingen 44 Noms 07 FLh Fabrieksinstellingen Fabrieksinstelling: 35°C Instelling: Van ”FLl” tot 45°C Funkcja functie. Chłodzenia Koeling 08 Cld 09 End Przykład: Voorbeeld: Funkcja chłodzenia powinna być In vochtige ruimtes dient men de koeling nieaktywna w pomieszczeniach o uit te schakelenwilgotności om condens te podwyższonej (Łazienka, voorkomen. kuchnia...) Yes : Funkcja Koeling Chłodzenia actief OFF: nieaktywna No : Koeling uitgeschakeld ON: Funkcja Chłodzenia aktywna 45 6 Nota’s _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ 46
advertisement
Key Features
- Precise temperature control with 0.1°C precision
- Choice of air or floor temperature sensing
- Adjustable proportional-integral (PWM) regulation for energy efficiency
- Temporary override function for quick adjustments
- Easy-to-use interface with amber backlight and clear display
- Silent operation for a peaceful environment
Related manuals
Frequently Answers and Questions
How do I change the operating mode?
Press the (OK) key to change the mode in the Operating mode menu.
What is the default comfort temperature?
The default comfort temperature is 20°C in heating mode.
Can I use an external sensor with this thermostat?
Yes, you can use an optional external sensor (10K at 25°C).
What is the maximum output power of this thermostat?
The maximum output power is 75W (4 actuators).
What type of electrical protection does this thermostat have?
The thermostat has Class II - IP30 electrical protection.
What is the power consumption of this thermostat?
The power consumption is ~3.5W.