Below you will find brief information for fine filter F76S AA, fine filter F76S AAM, fine filter F76S EA. This document provides installation instructions for the fine filter, a device that helps remove impurities from water. The filter is designed for drinking water installations and can be used in horizontal pipework with the filter bowl facing downwards. It is recommended to install shutoff valves and ensure good access for maintenance and inspection. The installation location should be protected against frost and the filter should be fitted immediately after the water meter. The filter needs to be cleaned regularly by back-flushing. It is suggested to have a planned maintenance contract with an installation company.

PDF
Document
Honeywell F76S AA, F76S AAM, F76S EA Installation Instructions | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Removes impurities from water

  • Designed for drinking water installations

  • Horizontal installation

  • Filter bowl facing downwards

  • Requires regular back-flushing

  • Easy access for maintenance

  • Frost-proof installation

  • Installation immediately after water meter

Frequently asked questions

The maximum operating temperature is 40°C with a clear filter bowl and 70°C with a red-bronze filter bowl.

The minimum operating pressure is 1.5 bar.

The fine filter should be cleaned by back-flushing at least every 2 months, according to DIN 1988, part 8.