Ideal 61-063 Volt Sensor detects 40-600VAC with respect to ground. It features non-contact voltage detection on lines with 40-600VAC, audible and visual voltage indication, and a compact, light, and sleek hand-held design. Use it to verify proper operation with a known live current source before testing the circuit in question.
advertisement
▼
Scroll to page 2
of
6
ND 2287-4 61-063 Volt Sensor In 1/9/07 1:03 PM #61-063 Volt Sensor™ Operating Instructions The Volt Sensor™ detects 40-600 VAC with respect to ground by simply grasping the instrument in your hand, depressing the clip and placing the tip near a live wire. FEATURES • Non Contact Voltage detection on lines with 40-600 VAC • Reads hot wire with respect to ground. Easy to recognize voltage with audible and visual indications. • Compact, light, sleek, hand-held design, complete with a durable built in pocket clip. ! WARNINGS 1. Instrument indicates positive presence of voltage between 40-600 VAC. Do not assume that no indication means a dead or de-energized circuit. 2. Voltages below 40V may not be detected by the Volt Sensor and may pose a shock hazard. These voltages can cause serious personal injury. 3. Do not operate without clip in place to avoid electric shock. 4. 600VAC is the maximum voltage that this instrument is designed to detect. 5. Do not use for indicating the presence of DC power. 6. Voltage detector will not read voltages through metal conduct or the like, and will not read through walls at a distance. 7. If the equipment is used in a manner not specified by IDEAL, the protection provided by the equipment may be impaired. Sensor Light Pocket clip and operating switch Battery cap OPERATION 1. Remove the battery cap, insert the two batteries. Be sure the batteries are inserted in correct polarity as indicated. Place the cap back on. 2. Hold the Volt Sensor in your hand by grasping and depressing the side clip firmly. Check device with a known live current source (wall receptacle or cord) while keeping the clip pressed against the pad. The Volt Sensor is indicating voltage as long as the red LED light flashes and the “beep” sound continues to oscillate in close proximity of a cord connected to a power source. 3. After verifying proper operation in step 2, the circuit in question can be tested. Page 1 ND 2287-4 61-063 Volt Sensor In 1/9/07 1:03 PM RATING & SPECIFICATIONS Model: Working Voltage Range: Frequency: Dielectric Strength: 61-063 40-600 VAC max to ground 50/60Hz 2000V, 1 minute, 100uA or less during dielectric strength test Safety: IEC61010-1 Cat III - 600V Operating Environment: 32° to 104° F (0° to 40° C). 80% RH max. 50% RH above 31° C. Operating Altitude: 2000m (6562 ft.) Battery: Two (2) 1.5V button type batteries, #61-201 (IEC #LR-44, NEDA # 1166A) Dimensions: 5.2”H x 1”W x .8”D (130 x 26 x 20mm) Weight: 1.4 oz (40g) Instrument complies with insulation category (overvoltage category III). Pollution degree 2 accordance with IEC-664. Indoor use. Industrial use. CAT III equipment is designed to protect against the transients in the equipment in fixed installations, such as distribution panels, feeders and short branch circuits for lighting systems in large buildings. Equipment protected by double insulation. Maintenance Do not attempt to repair this tester. It contains no user-serviceable parts. Repair or serving should only be performed by qualified personnel. Cleaning • Remove grease and grime with a clean, dry cloth. • Do not use abrasives or solvents. Battery Replacement Packaged complete with two button cell batteries and operating instructions. Install batteries before use. 61-063 ! WARNING: DO NOT OPERATE WITHOUT BATTERY COVER IN PLACE! Tester C US 4D31 Cat III - 600V Listed LIFETIME LIMITED WARRANTY Warranty limited solely to repair or replacement; no warranty of merchantability, fitness for a particular purpose or consequential damages. IDEAL INDUSTRIES, INC. Sycamore, IL 60178, U.S.A. 800-435-0705 Customer Assistance www.idealindustries.com ND 2287-4 Made in China Page 2 ND 2287-4 61-063 Volt Sensor In 1/9/07 1:03 PM #61-063 Light Pocket clip and operating switch Battery cap Page 3 ND 2287-4 61-063 Volt Sensor In 1/9/07 1:03 PM ! ADVERTENCIA: ¡NO LO UTILICE SIN LA CUBIERTA DE LAS BATERIAS COLOCADA! Tester C US 4D31 Cat III - 600V Listed Page 4 ND 2287-4 61-063 Volt Sensor In 1/9/07 1:03 PM #61-063 Light Pocket clip and operating switch Battery cap Page 5 ND 2287-4 61-063 Volt Sensor In 1/9/07 1:03 PM ! AVERTISSEMENT: NE PAS FAIRE FONCTIONNER SI LE COUVERCLE DES PILES N’EST PAS EN PLACE ! Tester C US 4D31 Cat III - 600V Listed Page 6
advertisement