UWE SAC Series Operation Manual
UWE SAC Series is a high-precision dual-counting scale designed for various weighing and counting applications. With its user-friendly interface, versatile functions, and reliable performance, it's an ideal choice for businesses and individuals who need accurate and efficient weighing solutions. Its features include weight and piece counting, tare function, multiple weighing units, memory storage, and auto power-off, making it an asset for various industries.
advertisement
SDC SERIES
HIGH PRECISION DUAL COUNTING SCALE
OPERATION MANUAL
PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT
TO OPERATE THE SCALE
OCTOBER 2002
Specifications subject to change without prior notice
CONTENTS
1. INSTALLATION
2. SPECIFICATIONS
3. KEYBOARDS, PANEL LAYOUT AND DESCRIPTION
4. SCALE SETUP
5. INSTRUCTION FOR USE
6. TROUBLESHOOTING
7. ERROR CODES AND DESCRIPTIONS
8. DAILY CARE AND MAINTENANCE
HIGH PRECISION DUAL COUNTING SCALE
OPERATION MANUAL
PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT
TO OPERATE THE SCALE
OCTOBER 2002
Specifications subject to change without prior notice
CONTENTS
1. INSTALLATION
2. SPECIFICATIONS
3. KEYBOARDS, PANEL LAYOUT AND DESCRIPTION
4. SCALE SETUP
5. INSTRUCTION FOR USE
6. TROUBLESHOOTING
7. ERROR CODES AND DESCRIPTIONS
8. DAILY CARE AND MAINTENANCE
1. INSTALLATION
CAUTION:
a. This is a precision measuring device, handle with
extreme care.
b. Allow 2 minutes for warm up before operating.
1.1 CHECK and make sure that the following accessories
are included:
a. This operation manual
b. Scale x 1
c. Platter x 1
d. Power adaptor x 1
Contact your dealer if any item is missing.
1.2 INSERT the platter onto the scale carefully. No
excessive force is required.
1.3 POWER THE SCALE ON
a. Before plugging the power adaptor into an electricity
outlet, check and make sure that the input voltage
of power adaptor matches with the output voltage of
the outlet. If not, do not plug in and contact your
dealer immediately.
b. Before first time use, plug the main adaptor into
the power outlet and charge the scale for at least
8 hours.
1.4 RETAIN the packing materials for future
transportation purposes.
CAUTION:
In s ome countries, this unit is required by law to be
sealed (or stamped) and bearing a serial number. Do not
break or remove the seal (or stamp) or serial affixed
to this scale. Such actions may offense the law and void
the warranty. Contact your dealer for m ore information
or after sales service.
For most accurate result, do not use this scale when
environment conditions fall beyond those listed in
SPECIFICATIONS.
Do not attempt to open this unit or any trouble shootings
except those listed in TROUBLESHOOTING.
CAUTION:
a. This is a precision measuring device, handle with
extreme care.
b. Allow 2 minutes for warm up before operating.
1.1 CHECK and make sure that the following accessories
are included:
a. This operation manual
b. Scale x 1
c. Platter x 1
d. Power adaptor x 1
Contact your dealer if any item is missing.
1.2 INSERT the platter onto the scale carefully. No
excessive force is required.
1.3 POWER THE SCALE ON
a. Before plugging the power adaptor into an electricity
outlet, check and make sure that the input voltage
of power adaptor matches with the output voltage of
the outlet. If not, do not plug in and contact your
dealer immediately.
b. Before first time use, plug the main adaptor into
the power outlet and charge the scale for at least
8 hours.
1.4 RETAIN the packing materials for future
transportation purposes.
CAUTION:
In s ome countries, this unit is required by law to be
sealed (or stamped) and bearing a serial number. Do not
break or remove the seal (or stamp) or serial affixed
to this scale. Such actions may offense the law and void
the warranty. Contact your dealer for m ore information
or after sales service.
For most accurate result, do not use this scale when
environment conditions fall beyond those listed in
SPECIFICATIONS.
Do not attempt to open this unit or any trouble shootings
except those listed in TROUBLESHOOTING.
2. SPECIFICATIONS
2.1 GENERAL SPECIFICATIONS
Model No. Max1/e1 Max2/e2 Max3/e3
SAC-7.5C 1500g/0.1g 3000g/0.2g 7500g/0.5g
SAC-15C 3000g/0.2g 7500g/0.5g 15000g/1g
SAC-30C 7500g/0.5g 15000g/1g 30000g/2g
SAC-60C 15000g/1g 30000g/2g 60000g/5g
Platter
Size 230 x 345mm All Stainless Steel
Power
Source
Built-in Rechargeable or Power Adaptor
Operation
Environment
0o~40oC(32o~104oF), Non-condensed
R.H.=85%
Specifications subject to change without notice
2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE
SIZE WEIGHT SPECIFICATIONS
Recommended Minimum
Model No.
Piece Weight Weight
Applied
Sample Size
Weight
SAC-7.5C 0.05g 2g 2g
SAC-15C 0.1g 4g 4g
SAC-30C 0.25g 10g 10g
SAC-60C 0.5g 20g 20g
3. KEYBOARDS & PANEL LAYOUT AND
DESCRIPTION
2.1 GENERAL SPECIFICATIONS
Model No. Max1/e1 Max2/e2 Max3/e3
SAC-7.5C 1500g/0.1g 3000g/0.2g 7500g/0.5g
SAC-15C 3000g/0.2g 7500g/0.5g 15000g/1g
SAC-30C 7500g/0.5g 15000g/1g 30000g/2g
SAC-60C 15000g/1g 30000g/2g 60000g/5g
Platter
Size 230 x 345mm All Stainless Steel
Power
Source
Built-in Rechargeable or Power Adaptor
Operation
Environment
0o~40oC(32o~104oF), Non-condensed
R.H.=85%
Specifications subject to change without notice
2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE
SIZE WEIGHT SPECIFICATIONS
Recommended Minimum
Model No.
Piece Weight Weight
Applied
Sample Size
Weight
SAC-7.5C 0.05g 2g 2g
SAC-15C 0.1g 4g 4g
SAC-30C 0.25g 10g 10g
SAC-60C 0.5g 20g 20g
3. KEYBOARDS & PANEL LAYOUT AND
DESCRIPTION
KEYS DESCRIPTION
1. ON/ZERO KEY
Press this key to turn scale on or set weight to zero.
Refer to SPECIFICATIONS for maximum zero range.
2. TARE KEY
Press this key to tare off the weight of a container.
Refer to SPECIFICATIONS for maximum tare range.
3. NUMERIC AND DECIMAL KEYS
Press these keys to attain the desired numeric value.
4. OFF KEY
Press this key to turn scale off.
5. CLEAR KEY
Press this key to clear the numeric figure entered
6. UNIT PIECE WEIGHT SET KEY
Press this key to enter a unit piece weight.
7. NUMBER SET KEY
Press this key to enter the number of pieces on platter.
8. CHECK KEY
Press this key to set upper weight and quantity check
limit.
9. M+ KEY
Press this key to add current total count to memory.
Note: When the WEIGHT PANEL shows a negative value, the
total count will still give a positive count value. The
quantity is still added to memory when M+ key is pressed.
10. MR KEY
Press this key to recall accumulated results.
11. PLU KEYS
Press this key to set/recall a unit piece weight to/from
a PLU.
INDICATORS DESCRIPTION
12. ZERO INDICATOR
When a zero weight is detected, an arrow will appear
and point at this indicator.
13. NET WEIGHT INDICATOR
When the tare function is in operation, an arrow will
appear and point at this indicator. The weight being
displayed on the WEIGHT PANEL is a net weight.
14. LO-BAT INDICATOR
This indicator turns on when the battery inside scale
is low. Recharge the scale immediately. Failure to do
so may cause unrecoverable damage to the battery.
1. ON/ZERO KEY
Press this key to turn scale on or set weight to zero.
Refer to SPECIFICATIONS for maximum zero range.
2. TARE KEY
Press this key to tare off the weight of a container.
Refer to SPECIFICATIONS for maximum tare range.
3. NUMERIC AND DECIMAL KEYS
Press these keys to attain the desired numeric value.
4. OFF KEY
Press this key to turn scale off.
5. CLEAR KEY
Press this key to clear the numeric figure entered
6. UNIT PIECE WEIGHT SET KEY
Press this key to enter a unit piece weight.
7. NUMBER SET KEY
Press this key to enter the number of pieces on platter.
8. CHECK KEY
Press this key to set upper weight and quantity check
limit.
9. M+ KEY
Press this key to add current total count to memory.
Note: When the WEIGHT PANEL shows a negative value, the
total count will still give a positive count value. The
quantity is still added to memory when M+ key is pressed.
10. MR KEY
Press this key to recall accumulated results.
11. PLU KEYS
Press this key to set/recall a unit piece weight to/from
a PLU.
INDICATORS DESCRIPTION
12. ZERO INDICATOR
When a zero weight is detected, an arrow will appear
and point at this indicator.
13. NET WEIGHT INDICATOR
When the tare function is in operation, an arrow will
appear and point at this indicator. The weight being
displayed on the WEIGHT PANEL is a net weight.
14. LO-BAT INDICATOR
This indicator turns on when the battery inside scale
is low. Recharge the scale immediately. Failure to do
so may cause unrecoverable damage to the battery.
5
6
7
8
9
10
11
12
13
14
15
advertisement
Key Features
- High Precision
- Dual Counting
- Rechargeable Battery
- Tare Function
- Unit Piece Weight Memory
- Check Functions
- Memory Functions
- RS232C Output (optional)
- Printer Output (optional)
Related manuals
Frequently Answers and Questions
What are the recommended minimum piece weights for this scale?
Refer to 2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE SIZE WEIGHT SPECIFICATIONS for the minimum piece weights for each model.
How do I set the Auto Power Off function?
Refer to 4.4.3 Set Auto Power Off Status (F4) for instructions on disabling or enabling the Auto Power Off function.
What is the purpose of the LOW UNIT WEIGHT INDICATOR?
This indicator appears when the unit piece weight is too light for accurate counting results. Consider using a scale with a lower e1 value as listed in GENERAL SPECIFICATIONS.