BEA Microscan Kit 10LZRMICROSCAN2 Owner's Manual
BEA LZR-I100 is a stand-alone, door-mounted safety sensor for automatic swing doors. It utilizes laser technology to detect objects and people in the doorway, preventing the door from closing on them. The sensor can be used on single or double doors and features adjustable detection zones and sensitivity levels. It also has built-in anti-tamper protection and can be integrated with various access control systems.
advertisement
75.5753.02 LZR-MICROSCAN 20140107 Page 1 of 12
LZR-MICROSCAN
Stand-Alone, Door Mounted, Safety
Sensor for Automatic Swing Doors
(US version)
ENGLISH
DESCRIPTION
1. tilt adjustment 4. end caps 7. adjustment knob
2. sensor connection ports 5. optical window 8. LCD
3. sensor LED 6. plug-n-play ports 9. hub LEDs
INCLUDED KIT COMPONENTS
1
2
3
4
5
6
7
8 9
DESCRIPTION PART NUMBER SINGLE 1 PAIR/DE2
Left LZR-microscan Sensor 10LZRMICROLEFT 1 2
Right LZR-microscan Sensor 10LZRMICRORIGHT 1 2
LZR-microscan Hub 10LZRMICROSCANHUB 1 1
Master Sensor Harness 35.1326 1 2
Slave Sensor Harness 35.1327 1 2
Door Control Harness 20.5222 1 2
System Harness 20.5304 1 1
Eagle Harness 20.5069 1 1
Power Supply Harness 20.5095 1 1
Home Switch (Surface Mount) 50.5283 1 2
Door Loop / Cap Kit 70.0202 / 50.0078 1 2
On / Off / Hold Open Switch Jumper 20.5310 1 1
Left Pass-Through Sensor Endcap 41.7922 1 2
Right Pass-Through Sensor Endcap 41.7923 1 2
Sensor Spacer 70.5554 1 2
Spacer Mount Screws 50.0048 2 4
Sensor Mount Screws (Metal) 50.1818 2 4
Sensor Mount Scews (Wood) 50.5282 2 4
Endcap Screws 41.8632 4 4
Velcro Tabs 50.0046 2 2
LZR-microscan Mounting Template 75.5754 1 1
LZR-microscan User’s Guide 75.5753 1 1
Power Supply 30.5558 1 (Universal3 ONLY) 1 (Universal 3 ONLY)
On / Off / Hold Open Switch 10DOORSWITCH 1 (Universal 3 ONLY) 1 (Universal 3 ONLY)
REQUIRED TOOLS
TOOL
Power Drill
Tape Measure
Magnetic Phillips #0
Phillips #2
1/8” Drill Bit
5/16” Drill Bit
3/8” Drill Bit
1/2” Drill Bit
Pencil
Center Punch / Hammer
Wire Nuts
Wire Snips
Wire Fish
MOUNTING KITS
DESCRIPTION PART NUMBER
Narrow Frame Door 10MICROSCANMOUNT
Glass / Fire Door 10MICROSCAN-Y
NOTES:
1: Single Door Kit
(10LZRMICROSCAN1)
2: Pair/Dual Egress Door Kit
(10LZRMICROSCAN2)
3: Universal Single Door Kit
(10LZRMICROSCAN1U) and
Univeral Pair/Dual Egrees Door Kit
(10LZRMICROSCAN2U)
LZR-MICROSCAN
Stand-Alone, Door Mounted, Safety
Sensor for Automatic Swing Doors
(US version)
ENGLISH
DESCRIPTION
1. tilt adjustment 4. end caps 7. adjustment knob
2. sensor connection ports 5. optical window 8. LCD
3. sensor LED 6. plug-n-play ports 9. hub LEDs
INCLUDED KIT COMPONENTS
1
2
3
4
5
6
7
8 9
DESCRIPTION PART NUMBER SINGLE 1 PAIR/DE2
Left LZR-microscan Sensor 10LZRMICROLEFT 1 2
Right LZR-microscan Sensor 10LZRMICRORIGHT 1 2
LZR-microscan Hub 10LZRMICROSCANHUB 1 1
Master Sensor Harness 35.1326 1 2
Slave Sensor Harness 35.1327 1 2
Door Control Harness 20.5222 1 2
System Harness 20.5304 1 1
Eagle Harness 20.5069 1 1
Power Supply Harness 20.5095 1 1
Home Switch (Surface Mount) 50.5283 1 2
Door Loop / Cap Kit 70.0202 / 50.0078 1 2
On / Off / Hold Open Switch Jumper 20.5310 1 1
Left Pass-Through Sensor Endcap 41.7922 1 2
Right Pass-Through Sensor Endcap 41.7923 1 2
Sensor Spacer 70.5554 1 2
Spacer Mount Screws 50.0048 2 4
Sensor Mount Screws (Metal) 50.1818 2 4
Sensor Mount Scews (Wood) 50.5282 2 4
Endcap Screws 41.8632 4 4
Velcro Tabs 50.0046 2 2
LZR-microscan Mounting Template 75.5754 1 1
LZR-microscan User’s Guide 75.5753 1 1
Power Supply 30.5558 1 (Universal3 ONLY) 1 (Universal 3 ONLY)
On / Off / Hold Open Switch 10DOORSWITCH 1 (Universal 3 ONLY) 1 (Universal 3 ONLY)
REQUIRED TOOLS
TOOL
Power Drill
Tape Measure
Magnetic Phillips #0
Phillips #2
1/8” Drill Bit
5/16” Drill Bit
3/8” Drill Bit
1/2” Drill Bit
Pencil
Center Punch / Hammer
Wire Nuts
Wire Snips
Wire Fish
MOUNTING KITS
DESCRIPTION PART NUMBER
Narrow Frame Door 10MICROSCANMOUNT
Glass / Fire Door 10MICROSCAN-Y
NOTES:
1: Single Door Kit
(10LZRMICROSCAN1)
2: Pair/Dual Egress Door Kit
(10LZRMICROSCAN2)
3: Universal Single Door Kit
(10LZRMICROSCAN1U) and
Univeral Pair/Dual Egrees Door Kit
(10LZRMICROSCAN2U)
Page 2 of 12 75.5753.02 LZR-MICROSCAN 20140107
Shut off all power going to header before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board
ensure you dissipate your body’s ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause
damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by
BEA, Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
PRECAUTIONS
Avoid extreme vibrations. Do not cover the sensor. Avoid moving objects and
light sources in detection
zone.
Avoid highly reflective
objects in the detection
zone.
It is reccommended to
clean the opitcal parts
at least once per year or
more if required due to
environmental conditions.
Do not use
abrasive cleaning
components.
The door conrol unit and
the door header must be
correctly grounded.
Only trained and qualified
personnel may install and
setup the sensor.
Always test the proper
operation of the
installation before leaving
the premises.
The warranty is void if
unauthorized repairs are
made or attempted by
unauthorized personnel.
INSTALLATION
MAINTENANCE
SAFETY
IR laser (Class 1); wavelength 905 nm; max. output pulse power 35 W
CAUTION: Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure
LASER
! • The device should not be used for purposes other than its intended use. All other uses cannot be guaranteed by the
manufacturer of the sensor.
• The installer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety.
• The manufacturer of the sensor cannot be held responsbile for incorrect installations or inappropriate adjustments of the
sensor.
Shut off all power going to header before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board
ensure you dissipate your body’s ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause
damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by
BEA, Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
PRECAUTIONS
Avoid extreme vibrations. Do not cover the sensor. Avoid moving objects and
light sources in detection
zone.
Avoid highly reflective
objects in the detection
zone.
It is reccommended to
clean the opitcal parts
at least once per year or
more if required due to
environmental conditions.
Do not use
abrasive cleaning
components.
The door conrol unit and
the door header must be
correctly grounded.
Only trained and qualified
personnel may install and
setup the sensor.
Always test the proper
operation of the
installation before leaving
the premises.
The warranty is void if
unauthorized repairs are
made or attempted by
unauthorized personnel.
INSTALLATION
MAINTENANCE
SAFETY
IR laser (Class 1); wavelength 905 nm; max. output pulse power 35 W
CAUTION: Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure
LASER
! • The device should not be used for purposes other than its intended use. All other uses cannot be guaranteed by the
manufacturer of the sensor.
• The installer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety.
• The manufacturer of the sensor cannot be held responsbile for incorrect installations or inappropriate adjustments of the
sensor.
75.5753.02 LZR-MICROSCAN 20140107 Page 3 of 12
PREPARATION
IMPORTANT:
In order to guarantee proper installation, instructions must be followed in order!
Verify operation/functionality of door control and operator prior to system installation.
Sensors
1 2
Determine on which side of door
Door Loop will be installed and cut
to shortest length to avoid loop in
detection zone.
Take sensor to be mounted on
loop side and remove Blank
Endcap closest to door hinge 1
.
Hub
1 2
Install hub in door header,
centered and in an easily
accessible location.
Plug System Harness into hub port
labeled System. Do not plug in
any other harnesses.
3
Route Master Sensor Harness
through Door Loop.
5
Affix Door Loop to sensor with
Pass-Through Endcap and three
(3) screws 2
.
4
Plug Master Sensor Harness into
sensor at closest port.
NOTES:
1: For left sensor, remove left
Blank Endcap or for right sensor,
remove right Blank endcap.
2: Pull extra Master Sensor
Harness slack through Door
Loop (away from sensor) before
tightening endcap screws.
PREPARATION
IMPORTANT:
In order to guarantee proper installation, instructions must be followed in order!
Verify operation/functionality of door control and operator prior to system installation.
Sensors
1 2
Determine on which side of door
Door Loop will be installed and cut
to shortest length to avoid loop in
detection zone.
Take sensor to be mounted on
loop side and remove Blank
Endcap closest to door hinge 1
.
Hub
1 2
Install hub in door header,
centered and in an easily
accessible location.
Plug System Harness into hub port
labeled System. Do not plug in
any other harnesses.
3
Route Master Sensor Harness
through Door Loop.
5
Affix Door Loop to sensor with
Pass-Through Endcap and three
(3) screws 2
.
4
Plug Master Sensor Harness into
sensor at closest port.
NOTES:
1: For left sensor, remove left
Blank Endcap or for right sensor,
remove right Blank endcap.
2: Pull extra Master Sensor
Harness slack through Door
Loop (away from sensor) before
tightening endcap screws.
Page 4 of 12 75.5753.02 LZR-MICROSCAN 20140107
INSTALLATION
1
HUB
Home
Switch Home
Switch
2
Install Home Switch at desired
location. Wire nut white Home Switch wires
to orange wires of System Harness
plugged into hub 2 .
Sensors
MOST BUTT HUNG
MOST CENTER PIVOT
DISTANCE FROM
TOP OF DOOR
MOUNTING HEIGHT RANGE: 6’7” - 8’2”
75.5754.01 20140107 LZR-microscan Mounting Template
microscan
Scan for Product Info
DISTANCE FROM
EDGE OF DOOR
Reference LZR-microscan User’s Guide
75.5753 for full installation instructions
5/16 “
1/8 “
*
*
*
*
sensor
mounting
wire passage
1/8 “
spacer
mounting
LEFT
MOUNT
MOUNTING INSTRUCTIONS
* When using spacer, drill any two (2) spacer mounting
holes and wire passage hole instead of sensor mounting
holes .
When using optional mounting holes it may be
neccessary to remove end caps or sensor from base.
STEP 2: FOLD ALONG APPROPRIATE
HORIZONTAL AND VERTICAL LINES AND
ALIGN WITH PIVOT EDGE AND TOP OF DOOR
STEP 3: MARK AND DRILL THREE (3) HOLES *
STEP 1: SURVEY BOTH SIDES OF DOOR TO
DETERMINE APPROPRIATE MOUNTING
LOCATION (DISTANCE FROM PIVOT EDGE
AND DISTANCE FROM TOP OF DOOR),
TAKING INTO ACCOUNT FRAME CLEARANCE,
FINGER GUARD, DOOR ARM, ETC.
STEP 4: FLIP TEMPLATE AND REPEAT FOR
RIGHT SENSOR
NOTES:
Mount sensors as close to top of door and as close to
hinge of door as possible.
Spacer required for applications with hardware
extending across width of door and protruding more
than 2 in.
For thin frame aluminum doors, mounting arm kit
may be used. When using mounting arm kit, do not
use this template.
1 2 3
Use Mounting Template to
position each sensor correctly.
Check for obstructions/clearance.
Align Mounting Template, mark
and drill holes 1
. Repeat on both
sides of door.
Run Slave Sensor Harness through
door.
4 5 6
Mount sensors (using appropriate
screws) by following instructions
on Mounting Template.
Plug in Slave Sensor Harness at
the upper most port on sensor. Install Door Loop: drill 1/2”
passage hole in header and jamb,
route Master Sensor Harness,
install cap.
7 8
Plug Master Sensor Harness into
hub port labeled Door A Sensors If necessary, repeat steps 1-7 for
second door leaf using hub port
Door B Sensors.
NOTES:
1: Any dry contact home switch
or auxiliary switch may be used
and must be closed when door
is closed.
2: For simultaneous pairs or
dual egress doors, two (2) Home
Switches must be wired in series
with orange wires of System
Harness plugged into hub.
Switch must “break” as soon as
door begins to open.
NOTES:
1. Spacer required for applications
with door hardware extendeing
across width of door and
protruding more than 2 in.
Do not apply sensor covers until
system is fully operational.
Do not adjust tilt angle.
Home Switch1
Refer to mounting template for full mounting instructions!
INSTALLATION
1
HUB
Home
Switch Home
Switch
2
Install Home Switch at desired
location. Wire nut white Home Switch wires
to orange wires of System Harness
plugged into hub 2 .
Sensors
MOST BUTT HUNG
MOST CENTER PIVOT
DISTANCE FROM
TOP OF DOOR
MOUNTING HEIGHT RANGE: 6’7” - 8’2”
75.5754.01 20140107 LZR-microscan Mounting Template
microscan
Scan for Product Info
DISTANCE FROM
EDGE OF DOOR
Reference LZR-microscan User’s Guide
75.5753 for full installation instructions
5/16 “
1/8 “
*
*
*
*
sensor
mounting
wire passage
1/8 “
spacer
mounting
LEFT
MOUNT
MOUNTING INSTRUCTIONS
* When using spacer, drill any two (2) spacer mounting
holes and wire passage hole instead of sensor mounting
holes .
When using optional mounting holes it may be
neccessary to remove end caps or sensor from base.
STEP 2: FOLD ALONG APPROPRIATE
HORIZONTAL AND VERTICAL LINES AND
ALIGN WITH PIVOT EDGE AND TOP OF DOOR
STEP 3: MARK AND DRILL THREE (3) HOLES *
STEP 1: SURVEY BOTH SIDES OF DOOR TO
DETERMINE APPROPRIATE MOUNTING
LOCATION (DISTANCE FROM PIVOT EDGE
AND DISTANCE FROM TOP OF DOOR),
TAKING INTO ACCOUNT FRAME CLEARANCE,
FINGER GUARD, DOOR ARM, ETC.
STEP 4: FLIP TEMPLATE AND REPEAT FOR
RIGHT SENSOR
NOTES:
Mount sensors as close to top of door and as close to
hinge of door as possible.
Spacer required for applications with hardware
extending across width of door and protruding more
than 2 in.
For thin frame aluminum doors, mounting arm kit
may be used. When using mounting arm kit, do not
use this template.
1 2 3
Use Mounting Template to
position each sensor correctly.
Check for obstructions/clearance.
Align Mounting Template, mark
and drill holes 1
. Repeat on both
sides of door.
Run Slave Sensor Harness through
door.
4 5 6
Mount sensors (using appropriate
screws) by following instructions
on Mounting Template.
Plug in Slave Sensor Harness at
the upper most port on sensor. Install Door Loop: drill 1/2”
passage hole in header and jamb,
route Master Sensor Harness,
install cap.
7 8
Plug Master Sensor Harness into
hub port labeled Door A Sensors If necessary, repeat steps 1-7 for
second door leaf using hub port
Door B Sensors.
NOTES:
1: Any dry contact home switch
or auxiliary switch may be used
and must be closed when door
is closed.
2: For simultaneous pairs or
dual egress doors, two (2) Home
Switches must be wired in series
with orange wires of System
Harness plugged into hub.
Switch must “break” as soon as
door begins to open.
NOTES:
1. Spacer required for applications
with door hardware extendeing
across width of door and
protruding more than 2 in.
Do not apply sensor covers until
system is fully operational.
Do not adjust tilt angle.
Home Switch1
Refer to mounting template for full mounting instructions!
5
6
7
8
9
10
11
12
advertisement
Key Features
- Stand-alone, door mounted
- Laser based time-of-flight measurement
- Plug-and-play installation
- Compatible with variety of door controls
- Mountable on various door types
- Easy to setup (Teach-in)
- Monitoring features (Safety, Stall, Activation)
Related manuals
Frequently Answers and Questions
What kind of door can I use this sensor with?
This sensor can be used with automatic swing doors. It can be mounted on various door types, including glass, fire, and narrow frame doors.
How do I install the sensor?
Installation instructions are provided in the user guide and include steps for mounting the sensor on the door, connecting the harnesses and wiring the door control.
How do I configure the sensor for my door?
The sensor is configured through a menu system on the hub using an LCD screen. You can set parameters such as the detection zone, guiderail height, and monitoring options.
What are the safety features of the sensor?
This is a safety sensor and it provides monitoring for Safety, Stall, and Activation signals. You can configure the monitoring options for these signals in the hub menus.
Can I monitor the door's operation?
Yes, the sensor has monitoring capabilities that allow you to see the status of the sensor, door control, and the home switch.
advertisement