The Dometic 641816CXX1C0 is a high-capacity, non-ducted air conditioner designed for RVs. It features a sleek, contemporary shroud design that reduces drag for improved mileage and a redesigned base pan with ribs for strength and durability. The unit is fully automated and worry-free, with a thermostatically controlled heat pump that automatically activates the LP gas furnace at 30 degrees for continuous relaxation. It also has a large, low-profile SMX bluelight display for easy control and a Comfort Control Center II for fully digital operation.

advertisement

Continuous product improvement! That best
describes what Dometic engineers have done
with the Penguin II. RVers will appreciate new
features and outstanding performance as only
Dometic can deliver. The Penguin II creates
the perfect comfort zone.
• Low profile, under 10-inches high – the lowest in the industry
• Sleek, contemporary shroud design reduces drag for improved mileage
• R410A refrigerant is eco-friendly and releases heat more efficiently
• Redesigned base pan with ribs is engineered for strength and durability
• Air conditioning or heat pump models available
• Perfect for ducted or non-ducted cooling systems
• Perfectly matched for Dometic’s exclusive QuietZone system
The nature of climate.â„¢
Dometic Penguin II
Low Profile Air Conditioner/Heat Pump
The Penguin II has a sleek, futuristic look with
incredible performance. Choose an air conditioner
or heat pump for comfort and durability.
Full automation means freedom from worry.
The heat pump is thermostatically controlled
(CCCII Thermostat) and automatically
activates the LP gas furnace at 30 degrees
for continuous relaxation.
Dometic does cool with style. Our air conditioners
are versatile performers with a low profile. Fully
automated and worry free.
Air Distribution Box
· Five multi-directional air slots
· Ratcheting side vents
· Washable Hepa-style filters
Single Zone LCD Thermostat
· Simple, three-button operation
· Easy control for cool/furnace,
heat pump or heat strips
· Low profile
· Manual or automatic control
· Large display screen
Dometic Penguin II — Low Profile Air Conditioner
Comfort Control Center II
· Fully digital operation
· Large, low profile SMX
bluelight display
· Industry first, real time-of-day,
area independent programming
· Easily controls rooftop AC,
heat pump, furnace, heat strip,
Aquaheat floor system or
Automatic Generator Start (AGS)
Return Air Grill
· Washable filter
· Quick cool air discharge
· Low profile
The Penguin Advantage
· Beautiful on the outside —
genius on the inside.
· What you don’t see makes the Penguin
the industry leader in low profile RV
air conditioners. Unique foam collar
around the motor shaft
prevents noise transfer
during operation.
Foam Seals prevent
unwanted heat transfer
and loss of performance.
Ribbed fan housing
adds strength for
reduced vibration.
Dynamic shroud design
reduces airflow resistance
while providing maximum
cooling.
High density foam
blocks prevent vibration
being felt inside the RV.
Raised ring around
screw and drain holes
prevent moisture from
entering the RV interior.
Rubber damper reduces
vibration and noise
while adding support
to copper tubing.
Copper tubing's lower heat
factor provides superior
heating and cooling.
Close tolerances
between the base pan
and shroud reduce
vibration and noise.
Insulated evaporator
housing prevents
solar heat build-up.
Convex basepan pattern
distributes the weight
of the AC unit for stability.
Radius corners
create strength, quiet
and smooth air flow.
For more information visit www.Dometic.com/USA
Dometic reserves the right to make improvements or modifications without notice.
Printed on recycled paper with 25% post consumer content with environmentally safe ink.
Printed in U.S.A. ©2011 Dometic Corporation OS2136 DRV-729/TM/11-11/1.5M
Outstanding Warranty
Dometic’s 2-Year Protection Plus warranty.
Dometic Penguin II — Low Profile Air Conditioner
Dometic Penguin II — Low Profile Heat Pump
Features 60312C 60315C 641915C 641815C 641835C 641816C 641916C
Nominal capacity, BTU/hr 11,000 13,500 13,500 13,500 13,500 High Capacity High Capacity
Installation type Non-ducted Non-ducted Non-ducted Non-ducted Non-ducted Non-ducted Non-ducted
or Ducted or Ducted or Ducted or Ducted or Ducted
Electrical rating 120V AC, 60 Hz, 1Ph
Compressor-rated load amps 10.5 12.7 12.7 12.7 12.7 13.4 13.4
Fan motor-rated load amps 2.6 2.6 2.6 2.6 2.6 2.6 2.6
Compressor-locked rotor amps 53 63 63 63 63 63 63
Fan motor-locked rotor amps 8.5 8.5 8.5 8.5 8.5 8.5 8.5
SCFM, high-speed max./min. 320/250 320/250 320/250 320/250 320/250 310/230 310/230
Heater amps/watts @ 120V AC 13.7/1,530 13.7/1,530
Refrigerant 410A (oz.) 19.0 18.0 18.0 18.0 18.0 25.0 25.0
Minimum wire size 12 AWG copper up to 24 feet. For distances over 24 feet consult the National Electrical Code.
AC circuit protection (User Supplied) 20 amp time delay fuse or 20 HCAR circuit breaker
DC circuit protection (User Supplied) Installation must comply with national, state, provincial and/or local electrical codes
Installed weight, lbs. 99 99 99 99 99 110 110
Minimum generator size - 1 unit 2.5 KW 3.5 KW 3.5 KW 3.5 KW 3.5 KW 3.5 KW 3.5 KW
Minimum generator size - 2 units 4.0 KW 5.0 KW 5.0 KW 5.0 KW 5.0 KW 5.0 KW 5.0 KW
Thermostat/Control options ADB or ADB or Single zone Multi zone Multi zone Multi zone Single zone
Control Kit Control Kit LCD CCC 2 CCC 2 CCC 2 LCD
641935C
Features 650015C 651815C 651816C 651916
Nominal capacity, BTU/hr. 13,500 13,500 High Capacity High Capacity
Installation type Non-ducted Non-ducted or Ducted Non-ducted or Ducted Non-ducted or Ducted
Electrical rating 120VAC, 60 Hz, 1Ph
Compressor-rated load amps 13.1 13.1 13.4 13.4
Fan motor-rated load amps 2.6 2.6 2.6 2.6
Compressor-locked rotor amps 63 63 63 63
Fan motor-locked rotor amps 8.5 8.5 8.5 8.5
SCFM, high-speed max./min. 320/250 320/250 310/230 310/230
Refrigerant 410A (oz.) 24 24 27 27
Minimum wire size 2 AWG copper up to 24 feet. For distances over 24 feet consult the National Electrical Code.
AC circuit protection (User Supplied) 20 amp time delay fuse or 20 HCAR circuit breaker
DC circuit protection (User Supplied) Installation must comply with national, state, provincial and/or local electrical codes
Installed weight, lbs. 99 99 99 99
Minimum generator size - 1 unit 3.5 KW 3.5 KW 3.5 KW 3.5 KW
Minimum generator size - 2 units 5.0 KW 5.0 KW 5.0 KW 5.0 KW
Thermostat/Control options ADB Multi zone Multi zone Single Zone LCD