NEOMITIS RT1 RF thermostat Installation instructions
RT1 RF is a wireless daily programmable room thermostat and receiver. The thermostat has a LCD display that shows the ambient temperature, time, and mode. It can be programmed to provide a comfortable temperature during the day and an economical temperature at night. You can also manually adjust the temperature by turning the dial. The device can be easily installed and used, and it helps you save energy and money.
advertisement
RT1 RF
WIRELESS DAILY PROGRAMMABLE
ROOM THERMOSTAT AND RECEIVER
Pack contains ....................................................................................1
Installation - Receiver .......................................................................1
Mounting of wall mouting plate .......................................................................1
Wiring ...................................................................................................................1
Mounting of the receiver...................................................................................2
Installation - Thermostat ....................................................................2
Installing batteries...............................................................................................2
Mounting of thermostat .....................................................................................2
Pairing procedure..............................................................................3
Installer settings .................................................................................3
Advanced installer setting ................................................................................3
Troubleshooting .................................................................................4
7HFKQLFDOVSHFLÀFDWLRQV ...................................................................4
RTE1RFA NEO ENG FP V04 26 06 2015
WIRING
1
INSTALLATION INSTRUCTIONS
All wiring must be in accordance with IEE regulations. This product is for
À[HGZLULQJRQO\
[[
[ [ [
[
Screw AnchorAA Batteries (LR6)
Thermostat Receiver Thermostat table stand
Screws
)RUEHVWSHUIRUPDQFHGRQRWPRXQWWKHUHFHLYHURQPHWDOZDOOER[HV
DQGOHDYHDWOHDVWFPGLVWDQFHIURPDQ\PHWDOREMHFWVLQFOXGLQJZDOO
ER[HVDQGERLOHUKRXVLQJ
MOUNTING OF WALL MOUTING PLATE
$OOHOHFWULFDOLQVWDOODWLRQZRUNVKRXOGEHFDUULHGRXWE\D
VXLWDEO\TXDOLÀHG(OHFWULFLDQRURWKHUFRPSHWHQWSHUVRQ,I\RX
are not sure how to install this thermostat consult either with a
TXDOLÀHGHOHFWULFLDQRUKHDWLQJ(QJLQHHU'RQRWUHPRYHRUUHÀW
WKHUHFHLYHURQWRWKHEDFNSODWHZLWKRXWWKHPDLQVVXSSO\WRWKH
V\VWHPEHLQJLVRODWHG
PACK CONTAINS
INSTALLATION - RECEIVER
N = Neutral
L = Live
1 = Not used
2 = Normally closed
3 = Common
4 = Normally open
2N L 1 43
7KHUHFHLYHULVÀ[HGRQWKHZDOOZLWKWKHVWDQGDUGZDOOSODWHZKLFKLV
supplied with the product.
1- Unscrew the 2 screws under the
receiver.
2- Remove the wall plate from the
receiver.
[
3- Secure the wall plate with the
two screws provided using the
horizontal and vertical holes.
4- In case of surface mounting,
a knock out area is provided
on the wall plate and on the
corresponding area of the
receiver.
WIRELESS DAILY PROGRAMMABLE
ROOM THERMOSTAT AND RECEIVER
Pack contains ....................................................................................1
Installation - Receiver .......................................................................1
Mounting of wall mouting plate .......................................................................1
Wiring ...................................................................................................................1
Mounting of the receiver...................................................................................2
Installation - Thermostat ....................................................................2
Installing batteries...............................................................................................2
Mounting of thermostat .....................................................................................2
Pairing procedure..............................................................................3
Installer settings .................................................................................3
Advanced installer setting ................................................................................3
Troubleshooting .................................................................................4
7HFKQLFDOVSHFLÀFDWLRQV ...................................................................4
RTE1RFA NEO ENG FP V04 26 06 2015
WIRING
1
INSTALLATION INSTRUCTIONS
All wiring must be in accordance with IEE regulations. This product is for
À[HGZLULQJRQO\
[[
[ [ [
[
Screw AnchorAA Batteries (LR6)
Thermostat Receiver Thermostat table stand
Screws
)RUEHVWSHUIRUPDQFHGRQRWPRXQWWKHUHFHLYHURQPHWDOZDOOER[HV
DQGOHDYHDWOHDVWFPGLVWDQFHIURPDQ\PHWDOREMHFWVLQFOXGLQJZDOO
ER[HVDQGERLOHUKRXVLQJ
MOUNTING OF WALL MOUTING PLATE
$OOHOHFWULFDOLQVWDOODWLRQZRUNVKRXOGEHFDUULHGRXWE\D
VXLWDEO\TXDOLÀHG(OHFWULFLDQRURWKHUFRPSHWHQWSHUVRQ,I\RX
are not sure how to install this thermostat consult either with a
TXDOLÀHGHOHFWULFLDQRUKHDWLQJ(QJLQHHU'RQRWUHPRYHRUUHÀW
WKHUHFHLYHURQWRWKHEDFNSODWHZLWKRXWWKHPDLQVVXSSO\WRWKH
V\VWHPEHLQJLVRODWHG
PACK CONTAINS
INSTALLATION - RECEIVER
N = Neutral
L = Live
1 = Not used
2 = Normally closed
3 = Common
4 = Normally open
2N L 1 43
7KHUHFHLYHULVÀ[HGRQWKHZDOOZLWKWKHVWDQGDUGZDOOSODWHZKLFKLV
supplied with the product.
1- Unscrew the 2 screws under the
receiver.
2- Remove the wall plate from the
receiver.
[
3- Secure the wall plate with the
two screws provided using the
horizontal and vertical holes.
4- In case of surface mounting,
a knock out area is provided
on the wall plate and on the
corresponding area of the
receiver.
2
• On the wall
MOUNTING OF THERMOSTAT
1- Unscrew the 2 screws under the
thermostat.
2- Remove the wall plate from the
thermostat.
[
1- Remove the batteries cover
which is placed on the front of
thermostat.
2- Insert the 2 batteries AA sup-
plied. Note the correct polarity
according to the engraving on
the thermostat when inserting
the batteries.
3- Replace the batteries cover.
MOUNTING OF THE RECEIVER
1- Replace the receiver on the
wall mounting plate.
2- Secure the receiver by screwing
the both locking screws under
the receiver.
[
3- Secure the wall plate with the
two screws provided using the
horizontal and vertical holes.
4- Replace the thermostat on the
wall mounting plate.
5- Secure the thermostat by
screwing the locking screws
under the thermostat. [
5HFRPPHQGHGORFDWLRQVIRU\RXUWKHUPRVWDW
To ensure that your thermostat provides accurate readings and controls
HIIHFWLYHO\LWPXVWEHLQVWDOOHGDSSUR[LPDWHO\PDERYHÁRRUOHYHORQ
an inside wall, away from direct sunshine and any other sources of heat
or cold such as radiators, cold draughts, etc.
• On the table stand
1- Insert the 2 pins inside the
wallplate and slide on the
stand .
2
1
2- Fold the stand and lock it into
the wallplate.
2 tilts possibilities
30° 37°
INSTALLING BATTERIES
INSTALLATION - THERMOSTAT
• On the wall
MOUNTING OF THERMOSTAT
1- Unscrew the 2 screws under the
thermostat.
2- Remove the wall plate from the
thermostat.
[
1- Remove the batteries cover
which is placed on the front of
thermostat.
2- Insert the 2 batteries AA sup-
plied. Note the correct polarity
according to the engraving on
the thermostat when inserting
the batteries.
3- Replace the batteries cover.
MOUNTING OF THE RECEIVER
1- Replace the receiver on the
wall mounting plate.
2- Secure the receiver by screwing
the both locking screws under
the receiver.
[
3- Secure the wall plate with the
two screws provided using the
horizontal and vertical holes.
4- Replace the thermostat on the
wall mounting plate.
5- Secure the thermostat by
screwing the locking screws
under the thermostat. [
5HFRPPHQGHGORFDWLRQVIRU\RXUWKHUPRVWDW
To ensure that your thermostat provides accurate readings and controls
HIIHFWLYHO\LWPXVWEHLQVWDOOHGDSSUR[LPDWHO\PDERYHÁRRUOHYHORQ
an inside wall, away from direct sunshine and any other sources of heat
or cold such as radiators, cold draughts, etc.
• On the table stand
1- Insert the 2 pins inside the
wallplate and slide on the
stand .
2
1
2- Fold the stand and lock it into
the wallplate.
2 tilts possibilities
30° 37°
INSTALLING BATTERIES
INSTALLATION - THERMOSTAT
3
NB: In order to ensure proper operation of the product, ensure that the
thermostat is not positioned near to an area which could be affected by
interference from another source. E.g.: a wireless transmitter or receiver,
TV, PC, etc.
Important: The thermostat measures the temperature of the place where
it is installed. It does not take into account the temperature differences
WKDWPD\H[LVWEHWZHHQGLIIHUHQWORFDWLRQVLQWKHKRXVHLIWKHWHPSHUD-
ture is not uniform.
ADVANCED INSTALLER SETTING
• Access
Select the Programming slider position and press
for 5 seconds to go into the dedicated installer setting.
5 sec.
INSTALLER SETTINGS
Move the mode slider to position.
Slider
position Icon Installer mode access
1 Set °C/°F temperature unit
2 Set 12 or 24 hours clock
3 Set calibration of the temperature dis-
played
4 Program lock
5 Select the type of control: 2 points or TPI
• Set °C/°F temperature
The pre-set temperature is the degree °C.
1- Rotate the dial to change to
degree Fahrenheit.
2- Then save by pressing or
move the Programming slider.
• Set 12/24 hours clock
The pre-set value is 12 hours clock.
1- Rotate the dial to change to
“24 hr”.
2- Then save by pressing or
move the Programming slider.
• Set calibration
,PSRUWDQW 7KLV RSHUDWLRQ LV UHVHUYHG IRU SURIHVVLRQDO LQVWDOOHUV RQO\ DQ\
wrong changes would result in control anomalies.
Change should only be made if the temperature measured (measured
by a reliable thermometer) is different by at least 1°C compared to the
setpoint temperature of the room thermostat.
The calibration adjusts the temperature measured by the ambient tem-
perature sensor to compensate for a deviation from + 3°C to - 3°C in in-
crements of 0.1°C.
,03257$17%HIRUHFDUU\LQJRXWWKHFDOLEUDWLRQLWLVUHFRPPHQGHGWRZDLW
IRUKDIWHUDVHWSRLQWWHPSHUDWXUHPRGLÀFDWLRQWRLQVXUHWKDWWKHDPELHQW
temperature is stabilized.
The pre-set calibration value is 0.
1- Rotate the dial to adjust the
calibration to the desired value.
2- Then save by pressing or
move the Programming slider.
• Program lock
The product is unlocked by default, OFF is displayed.
When program lock function is turned on then following functions will be
disabled:
- Regardless of physical location, Program Slider will always remain as
SHU581PRGH H[FHSWWRDFFHVV,QVWDOOHUVHWWLQJV
- In Mode Slider AUTO position: Manual override will not work.
- In Comfort Slider position: mode will remain as per AUTO mode.
- BOOST function is disabled.
2- Within 1 minute, press and hold
for 5 seconds the RF test button
on the thermostat. Pairing icon
LVÁDVKLQJ
1- Press and hold for 5 seconds
the RF test button on the
receiver. RF test green light is
blinking.
5 sec
Override RF Test
Override RF Test
5 sec
The thermostat and the receiver are not bonded together at the facto-
ry.
To bond the transmitter and the receiver together, proceed as below:
Note: the receiver is usually located near your boiler.
If you want to check the signal stren-
gth, move the mode slider to po-
sition and then press and release the
RF test button. RF icon blinks for 10
seconds then signal strength appears.
10 is the best signal strength.
4- Thermostat RF icon and re-
ceiver green light will be solid
when pairing is complete.
3- Thermostat RF icon and recei-
ver green light are blinking.
Override RF Test Override RF Test
PAIRING PROCEDURE
NB: In order to ensure proper operation of the product, ensure that the
thermostat is not positioned near to an area which could be affected by
interference from another source. E.g.: a wireless transmitter or receiver,
TV, PC, etc.
Important: The thermostat measures the temperature of the place where
it is installed. It does not take into account the temperature differences
WKDWPD\H[LVWEHWZHHQGLIIHUHQWORFDWLRQVLQWKHKRXVHLIWKHWHPSHUD-
ture is not uniform.
ADVANCED INSTALLER SETTING
• Access
Select the Programming slider position and press
for 5 seconds to go into the dedicated installer setting.
5 sec.
INSTALLER SETTINGS
Move the mode slider to position.
Slider
position Icon Installer mode access
1 Set °C/°F temperature unit
2 Set 12 or 24 hours clock
3 Set calibration of the temperature dis-
played
4 Program lock
5 Select the type of control: 2 points or TPI
• Set °C/°F temperature
The pre-set temperature is the degree °C.
1- Rotate the dial to change to
degree Fahrenheit.
2- Then save by pressing or
move the Programming slider.
• Set 12/24 hours clock
The pre-set value is 12 hours clock.
1- Rotate the dial to change to
“24 hr”.
2- Then save by pressing or
move the Programming slider.
• Set calibration
,PSRUWDQW 7KLV RSHUDWLRQ LV UHVHUYHG IRU SURIHVVLRQDO LQVWDOOHUV RQO\ DQ\
wrong changes would result in control anomalies.
Change should only be made if the temperature measured (measured
by a reliable thermometer) is different by at least 1°C compared to the
setpoint temperature of the room thermostat.
The calibration adjusts the temperature measured by the ambient tem-
perature sensor to compensate for a deviation from + 3°C to - 3°C in in-
crements of 0.1°C.
,03257$17%HIRUHFDUU\LQJRXWWKHFDOLEUDWLRQLWLVUHFRPPHQGHGWRZDLW
IRUKDIWHUDVHWSRLQWWHPSHUDWXUHPRGLÀFDWLRQWRLQVXUHWKDWWKHDPELHQW
temperature is stabilized.
The pre-set calibration value is 0.
1- Rotate the dial to adjust the
calibration to the desired value.
2- Then save by pressing or
move the Programming slider.
• Program lock
The product is unlocked by default, OFF is displayed.
When program lock function is turned on then following functions will be
disabled:
- Regardless of physical location, Program Slider will always remain as
SHU581PRGH H[FHSWWRDFFHVV,QVWDOOHUVHWWLQJV
- In Mode Slider AUTO position: Manual override will not work.
- In Comfort Slider position: mode will remain as per AUTO mode.
- BOOST function is disabled.
2- Within 1 minute, press and hold
for 5 seconds the RF test button
on the thermostat. Pairing icon
LVÁDVKLQJ
1- Press and hold for 5 seconds
the RF test button on the
receiver. RF test green light is
blinking.
5 sec
Override RF Test
Override RF Test
5 sec
The thermostat and the receiver are not bonded together at the facto-
ry.
To bond the transmitter and the receiver together, proceed as below:
Note: the receiver is usually located near your boiler.
If you want to check the signal stren-
gth, move the mode slider to po-
sition and then press and release the
RF test button. RF icon blinks for 10
seconds then signal strength appears.
10 is the best signal strength.
4- Thermostat RF icon and re-
ceiver green light will be solid
when pairing is complete.
3- Thermostat RF icon and recei-
ver green light are blinking.
Override RF Test Override RF Test
PAIRING PROCEDURE
4
Registered trademarks - All rights reserved
NEOMITIS ® LIMITED - 4th Floor, Lincoln House, 300 High Holborn, London WC1V 7JH
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: [email protected]
Creating innovative solutions for ambient comfort
www.neomitis.com
'LVSOD\GLVDSSHDUVRQWKHUPRVWDW
- Check batteries.
- Replace the 2 batteries. Only use alkaline 1.5V AA (LR6) batteries.
Do not use rechargeable batteries.
The heating does not come on or does not go off.
- Your room thermostat may have been set up close to a source of heat
or on a cold wall – put it in a recommended location (see the “Installing”
section on page 2 for these locations).
- Check that the radio communication works between the thermostat
and the receiver.
- Check if the boiler controlled by the programmable room thermostat is
properly connected to the receiver.
5DGLRWUDQVPLVVLRQLVQRWZRUNLQJSURSHUO\
7KHUHFHLYHULVQRWSLFNLQJXSWKHFRGHVHQWE\WKHWKHUPRVWDW
- Check and replace thermostat batteries .
2- The receiver does not recognize transmitter’s code.
- Pair the room thermostat transmitter with the receiver again See Pairing
section.
7KHUHFHLYHURUWKHWUDQVPLWWHULVDIIHFWHGE\LQWHUIHUHQFH
- Re site the transmitter.
- If possible, re site the receiver away from the source of the interference.
<RXZDQWWRFKDQJHWKHRSHUDWLQJPRGHEXWZKHQ\RXPRYHWKHPRGH
slider nothing happens.
- If the lock symbol is being displayed, then the thermostat is locked.
- Unlock the thermostat by following the instructions for doing so in the
"program lock" section (see page 3).
7KHWKHUPRVWDWLVLQ$XWR0RGHEXWSURJUDPVDUHQRWEHLQJH[HFXWHGE\
the boiler:
- Ensure that the thermostat is in good working condition.
- Change the batteries.
Compliance declaration: we hereby declare under our
sole responsibility that the products described in these
instructions comply with all the main requirements of the LVD
2006/95/EC, EMC 2004/108/EC, RoHS 2011/65/EU and are
PDQXIDFWXUHGXVLQJSURFHVVHVZKLFKDUHFHUWLÀHG,62
V2008.
TROUBLESHOOTING
TECHNICAL SPECIFICATIONS
Power supply: 2 alkaline 1.5 V AA (LR6) batteries.
%DWWHU\OLIHDSSUR[\HDUV
Receiver:
- Power supply: 230V~50/60Hz.
- Relay outputs: 5(2)A.
- Rated impulse voltage: 4000V.
- Micro-disconnection: Type 1B.
- Pollution degree: 2.
- Automatic action: 100,000 cycles.
- Class II.
0D[LPXP UDQJH LQ WKH KRPH 15m is typical but this varies depending
on the building construction eg plasterboard lined with metal foil the
number of walls and ceilings that the signal has to pass through and by
the surrounding electromagnetic environment.
Signal sending:HYHU\PLQXWHVPD[LPXPWLPHODJPLQXWHDIWHUVHW
point temperature has been changed.
Standards:
Environment :
- Operation temperature: 0°C to +40°C.
- Manual temperature setting range: from +5°C to +30°C.
- Storage temperature: from -10°C to +60°C.
- Humidity: 80% at +25°C (without condensation)
- Protection rating: IP30.
N.B.: this room thermostat is one part of a complete radio system and will
only work with the 230V AC receiver. Radio emitter, frequency from 2.40
to 2.48 GHz.
Manufactured by: IMHOTEP création.
The on the product indicates that you must dispose of it at the end of
its useful life at a special recycling point, in accordance with European
Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to
the retailer from which you buy the replacement equipment. Thus, it is not
ordinary household waste. Recycling products enables us to protect the
environment and to use less natural resources.
Transmitter Receiver
6DIHW\ R&TTE EMC RoHS 6DIHW\ R&TTE-EMC RoHS
EN62311
EN301489-1
EN301489-3
EN300440-1
EN300440-2
EN50581 EN60730-1
EN62479
EN301489-1
EN301489-3
EN300440-1
EN300440-2
EN50581
• Select 2 points/TPI
The pre-set control algorithm is TPI.
2 points = ON/OFF regulation.
TPI = Proportional control algorithm.
Note regarding the Advanced installer settings: If MODE slider is moved or
QRSUHVVURWDWLRQIRUVHFRQGVLWZLOOGLVFDUGFKDQJHVDQGH[LWLQVWDOOHU
mode.
1- Rotate the dial to ON and
locked.
2- Then save by pressing or
move the Programming slider.
1- Rotate the dial to change to 2
points control algorithm.
2- Then save by pressing or
move the Programming slider.
The radio link between the thermostat and the receiver is lost.
- Check the battery level status.
- Check that the radio communication works between the thermostat
and the receiver.If the radio communication does not work between
the receiver and the thermostat.
- Repeat the pairing between the thermostat and receiver (refer to
the user instructions).
7KHWKHUPRVWDWGRHVQRWFRQWUROSURSHUO\
7KHUPRVWDWVHQVRUPD\EHLQÁXHQFHGE\DVRXUFHRIKHDWRUFROG
- Check that the radio communication works between the thermostat
and receiver.
,IWKHSUREOHPSHUVLVWVFRQWDFW\RXULQVWDOOHU
Registered trademarks - All rights reserved
NEOMITIS ® LIMITED - 4th Floor, Lincoln House, 300 High Holborn, London WC1V 7JH
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: [email protected]
Creating innovative solutions for ambient comfort
www.neomitis.com
'LVSOD\GLVDSSHDUVRQWKHUPRVWDW
- Check batteries.
- Replace the 2 batteries. Only use alkaline 1.5V AA (LR6) batteries.
Do not use rechargeable batteries.
The heating does not come on or does not go off.
- Your room thermostat may have been set up close to a source of heat
or on a cold wall – put it in a recommended location (see the “Installing”
section on page 2 for these locations).
- Check that the radio communication works between the thermostat
and the receiver.
- Check if the boiler controlled by the programmable room thermostat is
properly connected to the receiver.
5DGLRWUDQVPLVVLRQLVQRWZRUNLQJSURSHUO\
7KHUHFHLYHULVQRWSLFNLQJXSWKHFRGHVHQWE\WKHWKHUPRVWDW
- Check and replace thermostat batteries .
2- The receiver does not recognize transmitter’s code.
- Pair the room thermostat transmitter with the receiver again See Pairing
section.
7KHUHFHLYHURUWKHWUDQVPLWWHULVDIIHFWHGE\LQWHUIHUHQFH
- Re site the transmitter.
- If possible, re site the receiver away from the source of the interference.
<RXZDQWWRFKDQJHWKHRSHUDWLQJPRGHEXWZKHQ\RXPRYHWKHPRGH
slider nothing happens.
- If the lock symbol is being displayed, then the thermostat is locked.
- Unlock the thermostat by following the instructions for doing so in the
"program lock" section (see page 3).
7KHWKHUPRVWDWLVLQ$XWR0RGHEXWSURJUDPVDUHQRWEHLQJH[HFXWHGE\
the boiler:
- Ensure that the thermostat is in good working condition.
- Change the batteries.
Compliance declaration: we hereby declare under our
sole responsibility that the products described in these
instructions comply with all the main requirements of the LVD
2006/95/EC, EMC 2004/108/EC, RoHS 2011/65/EU and are
PDQXIDFWXUHGXVLQJSURFHVVHVZKLFKDUHFHUWLÀHG,62
V2008.
TROUBLESHOOTING
TECHNICAL SPECIFICATIONS
Power supply: 2 alkaline 1.5 V AA (LR6) batteries.
%DWWHU\OLIHDSSUR[\HDUV
Receiver:
- Power supply: 230V~50/60Hz.
- Relay outputs: 5(2)A.
- Rated impulse voltage: 4000V.
- Micro-disconnection: Type 1B.
- Pollution degree: 2.
- Automatic action: 100,000 cycles.
- Class II.
0D[LPXP UDQJH LQ WKH KRPH 15m is typical but this varies depending
on the building construction eg plasterboard lined with metal foil the
number of walls and ceilings that the signal has to pass through and by
the surrounding electromagnetic environment.
Signal sending:HYHU\PLQXWHVPD[LPXPWLPHODJPLQXWHDIWHUVHW
point temperature has been changed.
Standards:
Environment :
- Operation temperature: 0°C to +40°C.
- Manual temperature setting range: from +5°C to +30°C.
- Storage temperature: from -10°C to +60°C.
- Humidity: 80% at +25°C (without condensation)
- Protection rating: IP30.
N.B.: this room thermostat is one part of a complete radio system and will
only work with the 230V AC receiver. Radio emitter, frequency from 2.40
to 2.48 GHz.
Manufactured by: IMHOTEP création.
The on the product indicates that you must dispose of it at the end of
its useful life at a special recycling point, in accordance with European
Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to
the retailer from which you buy the replacement equipment. Thus, it is not
ordinary household waste. Recycling products enables us to protect the
environment and to use less natural resources.
Transmitter Receiver
6DIHW\ R&TTE EMC RoHS 6DIHW\ R&TTE-EMC RoHS
EN62311
EN301489-1
EN301489-3
EN300440-1
EN300440-2
EN50581 EN60730-1
EN62479
EN301489-1
EN301489-3
EN300440-1
EN300440-2
EN50581
• Select 2 points/TPI
The pre-set control algorithm is TPI.
2 points = ON/OFF regulation.
TPI = Proportional control algorithm.
Note regarding the Advanced installer settings: If MODE slider is moved or
QRSUHVVURWDWLRQIRUVHFRQGVLWZLOOGLVFDUGFKDQJHVDQGH[LWLQVWDOOHU
mode.
1- Rotate the dial to ON and
locked.
2- Then save by pressing or
move the Programming slider.
1- Rotate the dial to change to 2
points control algorithm.
2- Then save by pressing or
move the Programming slider.
The radio link between the thermostat and the receiver is lost.
- Check the battery level status.
- Check that the radio communication works between the thermostat
and the receiver.If the radio communication does not work between
the receiver and the thermostat.
- Repeat the pairing between the thermostat and receiver (refer to
the user instructions).
7KHWKHUPRVWDWGRHVQRWFRQWUROSURSHUO\
7KHUPRVWDWVHQVRUPD\EHLQÁXHQFHGE\DVRXUFHRIKHDWRUFROG
- Check that the radio communication works between the thermostat
and receiver.
,IWKHSUREOHPSHUVLVWVFRQWDFW\RXULQVWDOOHU
5
6
7
8
advertisement
Key Features
- Wireless
- Daily Programmable
- Room Thermostat
- Receiver
- LCD Display
- Programmable
- Manual Control
- Easy Installation
- Energy Saving
Related manuals
Frequently Answers and Questions
How do I pair the RT1 RF thermostat with the receiver?
To pair the thermostat and receiver, press and hold the RF test button on the thermostat for 5 seconds. Then, within 1 minute, press and hold the RF test button on the receiver for 5 seconds. The pairing icon will blink on the thermostat and the green light will blink on the receiver. When pairing is complete, the icon and light will remain solid.
How do I set the time on the RT1 RF thermostat?
To set the time, turn the dial clockwise to increment the time and counterclockwise to decrement the time. Then press the Programming slider to save the setting.
How do I set the comfort and economy temperatures on the RT1 RF thermostat?
Move the Programming slider to the Comfort position and turn the dial to set the desired temperature. Then press the Programming slider to save the setting. Repeat this process for the Economy temperature by moving the slider to the Economy position.
What are the different modes on the RT1 RF thermostat?
The thermostat has four modes, automatic, comfort, economy, and standby. The automatic mode will follow the program you have set. Comfort mode will maintain the comfort temperature setting. Economy mode will maintain the economy temperature setting. Standby mode will maintain the frost protection temperature.
advertisement