Continental Fireplaces CB36NTR Direct Vent Gas Fireplace Owner's Manual

Continental Fireplaces CB36NTR Direct Vent Gas Fireplace Owner's Manual

The Continental Fireplaces CB36NTR is a direct vent gas fireplace designed for indoor use only. It meets Canadian and American safety standards and is certified for mobile home installation. This appliance is not a source of heat and is not intended for use with solid fuel. The CB36NTR is equipped with a safety barrier to reduce the risk of burns from the hot viewing glass. The vent system must be supported every 3 feet for both vertical and horizontal runs. The appliance must be installed by a qualified installer in accordance with local codes.

advertisement

FRENCH PG. 73
W415-2031 / A / 11.07.19
ADD MANUAL TITLE
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone 1 (866) 820-8686 • www.continentalfireplaces.com • hearth@continentalfi replaces.com
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)NATURAL GAS MODELS:
PROPANE GAS MODELS:
Product Name / Code
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
CSA /
INTERTEK
LOGO
SAFETY INFORMATION
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed
by a qualified installer, service agency, or the
supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
WARNING!
ENGLISH
$10.00
FOR INDOOR USE ONLY
IF INSTALLATION + OPERATION, ADD SERIAL
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD “PLACE
BARCODE LABEL ON THE OWNER’S MANUAL”
CB36NTR / CB36NTRE
CB36PTR / CB36PTRE
Builder Series 36
INSTALLATION AND
OPERATION MANUAL
B36 ILLUSTRATED
SAFETY BARRIER
W415-2031 / A / 11.07.19
EN
2
safety information
This appliance is hot when operated and
can cause severe burns if contacted.
Any changes or alterations to this
appliance or its controls can be
dangerous and is prohibited.
Do not operate appliance before reading and
understanding operating instructions. Failure
to operate appliance according to operating
instructions could cause fire or injury.
Ensure the glass door is opened or removed
when lighting the pilot for the first time and
when the gas supply has run out.
Risk of fire or asphyxiation, do not operate
appliance with fixed glass removed and never
obstruct the front opening of the appliance.
Do not connect 110 volts to the control valve,
with the exception of models; GSST8 and
GT8.
Risk of burns. The appliance should be turned off and cooled before servicing.
Do not install damaged, incomplete or substitute components.
Risk of cuts and abrasions. Wear protective gloves, protective footwear, and safety glasses during
installation. Sheet metal edges may be sharp.
Do not burn wood or other materials in this appliance.
Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing
and operating the appliance.
High pressure will damage valve. Disconnect gas supply piping before pressure testing gas line at
test pressures above 1/2 psig. Close the manual shut-off valve before pressure testing gas line at test
pressures equal to or less than 1/2 psig (35mb).
The appliance must not be operated at temperatures below freezing (32°F / 0°C). Allow the appliance
to warm to above freezing prior to operation, with the exception of models; GSS36, GSS42; these
appliances are suitable for 0°F / -18°C.
Children and adults should be alerted to hazards of high surface temperature and should stay
away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the
appliance. Toddlers, young children and others may be susceptible to accidental contact
burns. A physical barrier is recommended if there are at risk individuals in the house. To
restrict access to an appliance or stove, install an adjustable safety gate to keep toddlers,
young children and other at risk individuals out of the room and away from hot surfaces.
Clothing or other flammable material should not be placed on or near the appliance.
Due to high temperatures, the appliance should be located out of traffic and away from
furniture and draperies.
Furniture or other objects must be kept a minimum of 4 feet (1.22m) away from the front of the appliance.
Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot
surfaces.
Even after the appliance is off, it will remain hot for an extended period of time.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children
from hot surfaces. These screens and guards must be fastened to the fl oor.
Any safety screen, guard or barrier removed for servicing the appliance, must be replaced prior
to operating the appliance.
It is imperative that the control compartments, burners and circulating blower and its passageway in the
appliance and venting system are kept clean. The appliance and its venting system should be inspected
before use and at least annually by a qualified service person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material, etc. The appliance area must be kept clear and
free from combustible materials, gasoline and other fl ammable vapors and liquids.
If the appliance shuts off, do not re-light until you provide fresh air. If appliance keeps shutting off, have it
serviced. Keep burner and control compartment clean.
Under no circumstances should this appliance be modified.
Do not allow wind or fans to blow directly into the appliance. Avoid any drafts that alter burner flame
patterns.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
! DANGER
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and
shall be installed for the protection of children and other
at-risk individuals.
! WARNING
EN
W415-2031 / A / 11.07.19 3
safety information
! WARNING
Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this
appliance.
This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning
appliance.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the control system and any gas control which has
been under water.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass
should be done by a licensed or qualified service person, if equipped.
Do not strike or slam shut the appliance glass door, if equipped.
Only doors / optional fronts certified with the appliance are to be installed on the appliance.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As
with all plastic bags, these are not toys and should be kept away from children and infants.
Carbon or soot should not occur in a vent free appliance as it can distribute into the living area of your
home. If you notice any signs of carbon or soot, immediately turn off your appliance and arrange to have
it serviced by a qualified technician before operating it again.
If equipped, the screen must be in place (closed) when the appliance is in operation.
When equipped with pressure relief doors, they must be kept closed while the appliance is operating
to prevent exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of
the exhaust escaping through these openings can also cause the surrounding combustible materials to
overheat and catch fire.
Carbon monoxide poisoning may lead to death; early signs of carbon monoxide poisoning resemble the
fl u, with headache, dizziness and/or nausea. If you have these signs, the appliance may not be working
properly. Get fresh air at once! Have appliance serviced. Some people; pregnant women, persons with
heart or lung disease, anemia, those under the influence of alcohol, those at high altitudes are more
affected by carbon monoxide than others. Failure to keep the primary air opening(s) of the burner(s) clean
may result in sooting and property damage.
As with any combustion appliance, we recommend having your appliance regularly inspected and
serviced as well as having a Carbon Monoxide Detector installed in the same area to defend you and
your family against Carbon Monoxide (not applicable for outdoor appliances).
Ensure clearances to combustibles are maintained when building a mantel or shelves above the
appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting,
discolouration or damage to decorations, a TV or other electronic components.
For appliances equipped with a safety barrier; if the barrier becomes damaged, the barrier
shall be replaced with the manufacturer’s barrier for this appliance.
Installation and repair should be done by a qualified service person. It is imperative that control
compartments, burners and circulating air passageways of the appliance be kept clean.
For outdoor products only: this appliance must not be installed indoors or within any structure that
prevents or inhibits the exhaust gases from dissipating in the outside atmosphere.
If applicable, the millivolt version of this appliance uses and requires a fast acting thermocouple. Replace
only with a fast acting thermocouple supplied by Wolf Steel Ltd.
! WARNING !
Disconnect the appliance main gas valve/control
from the supply piping when pressure testing that
system at pressures in excess of 1/2 psi (3.5 kPa).
Isolate the appliance with it’s shut off valve during
any pressure testing of the supply piping at
pressures equal to or less than 1/2 psi (3.5 kPa).
FIRE RISK HAZARD / DELAYED IGNITION
High supply pressure will damage the valve / controls.
Add California Prop 65 warning
! WARNING: This product can expose you to chemicals including lead and lead compounds,
which are known to the State of California to cause cancer, and chemicals including carbon
monoxide, which are known to the State of California to cause birth defects or other reproduc-
tive harm. For more information, go to www.P65Warnings.ca.gov.
W415-2031 / A / 11.07.19
EN
4
table of contents
1.0 general information 5
1.1 rates and efficiencies 5
1.2 installation overview 6
1.3 rating plate information 8
1.4 mobile home installation 8
1.5 dimensions 9
2.0 venting requirements 10
2.1 typical vent installation 11
2.2 special vent installations 13
2.2.1 periscope termination 13
2.2.2 corner termination 13
2.3 minimum air terminal location
clearances 14
2.4 venting application flow chart 15
2.5 defi nitions 16
2.6 elbow vent length values 16
2.7 top exit horizontal termination 17
2.8 rear exit horizontal termination 19
2.9 top and rear exit vertical termination 21
2.10 rear exit 23
2.11 rear exit shield (for rear vent only) 24
2.12 top exit 25
3.0 rough framing 26
3.1 minimum framing dimensions 27
3.2 minimum enclosure clearances 28
4.0 venting installation 33
4.1 horizontal installation 34
4.2 vertical installation 34
4.3 using either flexible or rigid vent
components 35
4.3.1 horizontal air terminal installation 35
4.3.2 vertical air terminal installation 36
4.3.3 appliance vent connection 36
4.3.4 horizontal air terminal installation 37
4.3.5 vertical air terminal installation 38
4.4 vertical through existing chimney 39
4.4.1 restricting vertical vents 40
5.0 electrical information 41
5.1 electronic wiring diagram 41
5.2 battery back-up installation 42
6.0 gas installation 43
7.0 operation (electronic) 44
7.1 pilot-on-demand 45
8.0 operation (millivolt) 46
9.0 finish framing 47
9.1 minimum framing dimensions 47
10.0 finishing 48
10.1 safety barrier / door removal and
installation 48
10.2 front hood installation 49
10.3 non-combustible facing material 50
10.4 minimum mantel clearances 51
10.5 recessed installation 52
10.6 log placement 53
10.7 glowing embers 54
10.8 charcoal embers 54
10.9 logo placement 54
11.0 optional blower installation 55
12.0 adjustment 56
12.1 pilot burner adjustment 56
12.2 venturi adjustment 56
12.3 fl ame characteristics 57
13.0 maintenance 58
13.1 annual maintenance 59
13.2 door glass replacement 60
13.3 care of glass 60
14.0 replacement parts 61
14.1 overview 62
14.2 millivolt valve train assembly 63
14.3 electronic valve train assembly 64
15.0 accessories 65
16.0 troubleshooting (electronic) 66
17.0 troubleshooting (millivolt) 69
18.0 warranty 71
The information throughout this manual is believed to be correct at the time of printing. Wolf Steel Ltd. reserves
the right to change or modify any information within this manual at any time without notice. Changes, other than
editorial, are denoted by a vertical line in the margin.
note:
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
  • Page 21
  • Page 22
  • Page 23
  • Page 24
  • Page 25
  • Page 26
  • Page 27
  • Page 28
  • Page 29
  • Page 30
  • Page 31
  • Page 32
  • Page 33
  • Page 34
  • Page 35
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • Page 42
  • Page 43
  • Page 44
  • Page 45
  • Page 46
  • Page 47
  • Page 48
  • Page 49
  • Page 50
  • Page 51
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • Page 64
  • Page 65
  • Page 66
  • Page 67
  • Page 68
  • Page 69
  • Page 70
  • Page 71
  • Page 72
  • Page 73
  • Page 74
  • Page 75
  • Page 76
  • Page 77
  • Page 78
  • Page 79
  • Page 80
  • Page 81
  • Page 82
  • Page 83
  • Page 84
  • Page 85
  • Page 86
  • Page 87
  • Page 88
  • Page 89
  • Page 90
  • Page 91
  • Page 92
  • Page 93
  • Page 94
  • Page 95
  • Page 96
  • Page 97
  • Page 98
  • Page 99
  • Page 100
  • Page 101
  • Page 102
  • Page 103
  • Page 104
  • Page 105
  • Page 106
  • Page 107
  • Page 108
  • Page 109
  • Page 110
  • Page 111
  • Page 112
  • Page 113
  • Page 114
  • Page 115
  • Page 116
  • Page 117
  • Page 118
  • Page 119
  • Page 120
  • Page 121
  • Page 122
  • Page 123
  • Page 124
  • Page 125
  • Page 126
  • Page 127
  • Page 128
  • Page 129
  • Page 130
  • Page 131
  • Page 132
  • Page 133
  • Page 134
  • Page 135
  • Page 136
  • Page 137
  • Page 138
  • Page 139
  • Page 140
  • Page 141
  • Page 142
  • Page 143
  • Page 144
/

advertisement

Key Features

  • Direct vent gas fireplace
  • Indoor use only
  • Mobile home certified
  • Safety barrier
  • Venting requirements
  • Qualified installer required

Related manuals

Frequently Answers and Questions

What are the minimum clearances to combustible materials for the CB36NTR?
The minimum clearances vary depending on whether the framing and finishing materials are combustible or non-combustible. Refer to the rating plate and installation manual for specific details.
Is the Continental Fireplaces CB36NTR a heat source?
No, the CB36NTR is a vented decorative gas fireplace and is not intended to be a primary heat source.
What type of gas does the CB36NTR use?
The appliance is only for use with the type of gas indicated on the rating plate. It is not convertible for use with other gases, unless a certified kit is used.

advertisement