Continental Fireplaces CB36NTR Direct Vent Gas Fireplace spécification
publicité
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
Telephone: 1-800-461-5581 • www.continentalfireplaces.com
Specifications
Front Options
BUILDER SERIES 36 DIRECT VENT GAS FIREPLACE
W415-1886 / 10.26.18
FIREPLACES
Model BTU Width Height Depth Viewing Area
Actual Framing Actual Framing Actual Framing
CB36 18,000 35 35 1/2 34 5/8 35 15 3/4 16 23 11/16 X 30 11/16
Rough Framing Minimum Framing Clearances
35 1/2" 90.2cm
35"
88.9cm
2 3/16" 55.6mm
8" 203.2mm
16"
40.6cm
GAS
INLET
LOCATION
ELECTRICAL
CONNECTION
ENCLOSURE
TOP
FINISHING
MATERIAL
DESSUS
DE L’ENCEINTE
FRENCH
A B
Ref. Minimum rough framing dimensions
A 16” * (40.6cm)
B 35 1/2” (90.2cm)
* Based on 1/2” (12.7mm) finishing material thickness.
31 3/8"
28 3/8"
Heritage Front
40"
34 5/8"
1 1/4"
Clean Face Front
31 3/8"
28 3/8"
Zen Front
Telephone: 1-800-461-5581 • www.continentalfireplaces.com
Specifications
Front Options
BUILDER SERIES 36 DIRECT VENT GAS FIREPLACE
W415-1886 / 10.26.18
FIREPLACES
Model BTU Width Height Depth Viewing Area
Actual Framing Actual Framing Actual Framing
CB36 18,000 35 35 1/2 34 5/8 35 15 3/4 16 23 11/16 X 30 11/16
Rough Framing Minimum Framing Clearances
35 1/2" 90.2cm
35"
88.9cm
2 3/16" 55.6mm
8" 203.2mm
16"
40.6cm
GAS
INLET
LOCATION
ELECTRICAL
CONNECTION
ENCLOSURE
TOP
FINISHING
MATERIAL
DESSUS
DE L’ENCEINTE
FRENCH
A B
Ref. Minimum rough framing dimensions
A 16” * (40.6cm)
B 35 1/2” (90.2cm)
* Based on 1/2” (12.7mm) finishing material thickness.
31 3/8"
28 3/8"
Heritage Front
40"
34 5/8"
1 1/4"
Clean Face Front
31 3/8"
28 3/8"
Zen Front
BUILDER SERIES 36 DIRECT VENT GAS FIREPLACE
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
Telephone: 1-800-461-5581 • www.continentalfireplaces.com
Dimensions
Wall Penetration
Appliance Location
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for
the most up to date installation information.
Combustible Mantel Clearances
FIREPLACES
34 5/8"
879mm
9 1/16"
230mm
15 3/8"
391mm 4"
102mm
7"
178mm
35"
889mm
SAFETY BARRIER
24"
610mm
2 3/16"
55.5mm GAS INLET15 3/4"
400mm
8"
203mm
CB36 TOP VENT
COMBUSTIBLE NON-COMBUSTIBLE
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
3" [76.2mm]
MINIMUM
1"
[25mm]
50 1/2"
[128.3cm]
54"
[137.2cm]
CEILING
(MIN)
42 5/8"
[108.3cm]
MINIMUM
PLUS RISE*
1"
[25mm]
3"
[76,2mm]
COMBUSTIBLE INCOMBUSTIBLE
BRIQUE
3"
[76,2mm]
1"
[25mm]
1"
[25mm]
42 5/8"
[108,3cm]
MINIMUM
PLUS LA PENTE*
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
3"
[76.2mm]
3"
[76.2mm]
50 1/2"
[128,3cm]
54"
[137,2cm]
PLAFOND
(MIN)
3" [76,2mm]
MINIMUM
15 5/8”
[39.7cm]
15 5/8”
[39,7cm]
2"
[50.8mm]
2"
[50,8mm]
CEILING
ENCLOSURE
PLAFOND
ENCEINTE
CB36 REAR VENT
For rear vent termination NOT exceeding 10” (254mm) of horizontal vent run.
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0mm) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.6 3/8"
[162mm]
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.6 3/8"
[162mm]41"
[104.1cm]
10"-20"
[254mm-50.8cm]
VENT RUN
11 1/2"
[292mm]
41 "
[104.1cm]
1"-10"
[25mm-254mm]
VENT RUN
54 "
[137.2cm]
CEILING
(MIN)
4
[104
54
[137,2
PLAFO
(MI
Ceiling
Enclosure
P
MANTEL
HEIGHT
0
2" (50.8mm)
2 4 6 8 10 12
MANTEL DEPTH (INCHES)
4" (101.6mm)
6" (152.4mm)
10" (254mm)
12" (30.5cm)
8" (203.2mm)
TOP OF
APPLIANCE
2" 50.8mm
4" 101.6mm
6" 152.4mm
8" 203.2mm MANTEL
4"
101.6mm 2" 50.8mm
6"
152.4mm
8"
203.2mm
34 5/8”
[88cm]
2" 51mm
47 7/8" [121.6cm]
33 7/8"
86cm
35 1/2 " 90.2cm
16"
40.6cm
35 1/2”
[90.2cm]
Do not put objects in front of the
appliance (minimum distance of 4 feet)
W415-1886 / 10.26.18
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
Telephone: 1-800-461-5581 • www.continentalfireplaces.com
Dimensions
Wall Penetration
Appliance Location
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for
the most up to date installation information.
Combustible Mantel Clearances
FIREPLACES
34 5/8"
879mm
9 1/16"
230mm
15 3/8"
391mm 4"
102mm
7"
178mm
35"
889mm
SAFETY BARRIER
24"
610mm
2 3/16"
55.5mm GAS INLET15 3/4"
400mm
8"
203mm
CB36 TOP VENT
COMBUSTIBLE NON-COMBUSTIBLE
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
3" [76.2mm]
MINIMUM
1"
[25mm]
50 1/2"
[128.3cm]
54"
[137.2cm]
CEILING
(MIN)
42 5/8"
[108.3cm]
MINIMUM
PLUS RISE*
1"
[25mm]
3"
[76,2mm]
COMBUSTIBLE INCOMBUSTIBLE
BRIQUE
3"
[76,2mm]
1"
[25mm]
1"
[25mm]
42 5/8"
[108,3cm]
MINIMUM
PLUS LA PENTE*
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
3"
[76.2mm]
3"
[76.2mm]
50 1/2"
[128,3cm]
54"
[137,2cm]
PLAFOND
(MIN)
3" [76,2mm]
MINIMUM
15 5/8”
[39.7cm]
15 5/8”
[39,7cm]
2"
[50.8mm]
2"
[50,8mm]
CEILING
ENCLOSURE
PLAFOND
ENCEINTE
CB36 REAR VENT
For rear vent termination NOT exceeding 10” (254mm) of horizontal vent run.
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0mm) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.6 3/8"
[162mm]
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.6 3/8"
[162mm]41"
[104.1cm]
10"-20"
[254mm-50.8cm]
VENT RUN
11 1/2"
[292mm]
41 "
[104.1cm]
1"-10"
[25mm-254mm]
VENT RUN
54 "
[137.2cm]
CEILING
(MIN)
4
[104
54
[137,2
PLAFO
(MI
Ceiling
Enclosure
P
MANTEL
HEIGHT
0
2" (50.8mm)
2 4 6 8 10 12
MANTEL DEPTH (INCHES)
4" (101.6mm)
6" (152.4mm)
10" (254mm)
12" (30.5cm)
8" (203.2mm)
TOP OF
APPLIANCE
2" 50.8mm
4" 101.6mm
6" 152.4mm
8" 203.2mm MANTEL
4"
101.6mm 2" 50.8mm
6"
152.4mm
8"
203.2mm
34 5/8”
[88cm]
2" 51mm
47 7/8" [121.6cm]
33 7/8"
86cm
35 1/2 " 90.2cm
16"
40.6cm
35 1/2”
[90.2cm]
Do not put objects in front of the
appliance (minimum distance of 4 feet)
W415-1886 / 10.26.18
31 3/8"
28 3/8"
Heritage Front
40"
34 5/8"
1 1/4"
Clean Face Front
31 3/8"
28 3/8"
Zen Front24 Napoleon R oad, B arrie, O ntario, Canda L 4 M 0 G 8 • 2 1 4 B ayview D rive, B arrie, O ntario, Canada L 4 N 4 Y 8
T
elephone: 1 - 8 0 0 - 4 6 1 - 5 5 8 1 • w w w . continentalfireplaces.com
FRENCH
SÉRIE CONTRACTEUR 36 FOYER À GAZ VENTILÉ
W415-1886 / 10.26.18
Spécifications
Façades Décoratives
Ossature approximatif
Modèle BTU Largeur Hauteur Profondeur Dimensions de Vision
Réel Ossature Réel Ossature Réel Ossature
CB36 18,000 35 35 1/2 34 5/8 35 15 3/4 16 23 11/16 X 30 11/16
Ossature fini
35 1/2" 90.2cm
35"
88.9cm
2 3/16" 55.6mm
8" 203.2mm
16"
40.6cm
GAS
INLET
LOCATION
ELECTRICAL
CONNECTION
ENCLOSURE
TOP
FINISHING
MATERIAL
DESSUS
DE L’ENCEINTE
FRENCH
Façade Décorative
Héritage
Façade Décorative ZenFaçade Décorative Pleine
Vision
A B
Ref. Minimum rough framing dimensions
A 16” * (40.6cm)
B 35 1/2” (90.2cm)
* Based on 1/2” (12.7mm) finishing material thickness.
28 3/8"
Heritage Front
40"
34 5/8"
1 1/4"
Clean Face Front
31 3/8"
28 3/8"
Zen Front24 Napoleon R oad, B arrie, O ntario, Canda L 4 M 0 G 8 • 2 1 4 B ayview D rive, B arrie, O ntario, Canada L 4 N 4 Y 8
T
elephone: 1 - 8 0 0 - 4 6 1 - 5 5 8 1 • w w w . continentalfireplaces.com
FRENCH
SÉRIE CONTRACTEUR 36 FOYER À GAZ VENTILÉ
W415-1886 / 10.26.18
Spécifications
Façades Décoratives
Ossature approximatif
Modèle BTU Largeur Hauteur Profondeur Dimensions de Vision
Réel Ossature Réel Ossature Réel Ossature
CB36 18,000 35 35 1/2 34 5/8 35 15 3/4 16 23 11/16 X 30 11/16
Ossature fini
35 1/2" 90.2cm
35"
88.9cm
2 3/16" 55.6mm
8" 203.2mm
16"
40.6cm
GAS
INLET
LOCATION
ELECTRICAL
CONNECTION
ENCLOSURE
TOP
FINISHING
MATERIAL
DESSUS
DE L’ENCEINTE
FRENCH
Façade Décorative
Héritage
Façade Décorative ZenFaçade Décorative Pleine
Vision
A B
Ref. Minimum rough framing dimensions
A 16” * (40.6cm)
B 35 1/2” (90.2cm)
* Based on 1/2” (12.7mm) finishing material thickness.
24 Napoleon Road, Barrie, Ontario, Canda L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
Telephone: 1-800-461-5581 • www.continentalfireplaces.com
FRENCHSÉRIE CONTRACTEUR 36 FOYER À GAZ VENTILÉ
Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour info-
formation d’installation actuel.
Dimensions
Passage d’un section dans un mur
Location de l’appareilDégagements Combustible de la Tablette
2" 51mm
47 7/8" [121.6cm]
33 7/8"
86cm
35 1/2 " 90.2cm
16"
40.6cm
35 1/2”
[90.2cm]
Do not put objects in front of the
appliance (minimum distance of 4 feet)
MANTEL
HEIGHT
0
2" (50.8mm)
2 4 6 8 10 12
MANTEL DEPTH (INCHES)
4" (101.6mm)
6" (152.4mm)
10" (254mm)
12" (30.5cm)
8" (203.2mm)
TOP OF
APPLIANCE
2" 50.8mm
4" 101.6mm
6" 152.4mm
8" 203.2mm MANTEL
4"
101.6mm 2" 50.8mm
6"
152.4mm
8"
203.2mm
34 5/8”
[88cm]
Évacuation dessus Évacuation arrière
Pour les applications de terminaison arrière qui ne dépassent pas 10” (25,mm) du course
d’évacuation horizontale.
COMBUSTIBLE NON-COMBUSTIBLE
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
3" [76.2mm]
MINIMUM
1"
[25mm]
50 1/2"
[128.3cm]
54"
[137.2cm]
CEILING
(MIN)
42 5/8"
[108.3cm]
MINIMUM
PLUS RISE*
1"
[25mm]
3"
[76,2mm]
COMBUSTIBLE INCOMBUSTIBLE
BRIQUE
3"
[76,2mm]
1"
[25mm]
1"
[25mm]
42 5/8"
[108,3cm]
MINIMUM
PLUS LA PENTE*
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
3"
[76.2mm]
3"
[76.2mm]
50 1/2"
[128,3cm]
54"
[137,2cm]
PLAFOND
(MIN)
3" [76,2mm]
MINIMUM
15 5/8”
[39.7cm]
15 5/8”
[39,7cm]
2"
[50.8mm]
2"
[50,8mm]
CEILING
ENCLOSURE
PLAFOND
ENCEINTE
34 5/8"
879mm
9 1/16"
230mm
15 3/8"
391mm 4"
102mm
7"
178mm
35"
889mm
SAFETY BARRIER
24"
610mm
2 3/16"
55.5mm GAS INLET15 3/4"
400mm
8"
203mm
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0mm) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.6 3/8"
[162mm]
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.6 3/8"
[162mm]41"
[104.1cm]
10"-20"
[254mm-50.8cm]
VENT RUN
11 1/2"
[292mm]
41 "
[104.1cm]
1"-10"
[25mm-254mm]
VENT RUN
54 "
[137.2cm]
CEILING
(MIN)
Ceiling
Enclosure
W415-1886 / 10.26.18
Telephone: 1-800-461-5581 • www.continentalfireplaces.com
FRENCHSÉRIE CONTRACTEUR 36 FOYER À GAZ VENTILÉ
Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour info-
formation d’installation actuel.
Dimensions
Passage d’un section dans un mur
Location de l’appareilDégagements Combustible de la Tablette
2" 51mm
47 7/8" [121.6cm]
33 7/8"
86cm
35 1/2 " 90.2cm
16"
40.6cm
35 1/2”
[90.2cm]
Do not put objects in front of the
appliance (minimum distance of 4 feet)
MANTEL
HEIGHT
0
2" (50.8mm)
2 4 6 8 10 12
MANTEL DEPTH (INCHES)
4" (101.6mm)
6" (152.4mm)
10" (254mm)
12" (30.5cm)
8" (203.2mm)
TOP OF
APPLIANCE
2" 50.8mm
4" 101.6mm
6" 152.4mm
8" 203.2mm MANTEL
4"
101.6mm 2" 50.8mm
6"
152.4mm
8"
203.2mm
34 5/8”
[88cm]
Évacuation dessus Évacuation arrière
Pour les applications de terminaison arrière qui ne dépassent pas 10” (25,mm) du course
d’évacuation horizontale.
COMBUSTIBLE NON-COMBUSTIBLE
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
3" [76.2mm]
MINIMUM
1"
[25mm]
50 1/2"
[128.3cm]
54"
[137.2cm]
CEILING
(MIN)
42 5/8"
[108.3cm]
MINIMUM
PLUS RISE*
1"
[25mm]
3"
[76,2mm]
COMBUSTIBLE INCOMBUSTIBLE
BRIQUE
3"
[76,2mm]
1"
[25mm]
1"
[25mm]
42 5/8"
[108,3cm]
MINIMUM
PLUS LA PENTE*
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
3"
[76.2mm]
3"
[76.2mm]
50 1/2"
[128,3cm]
54"
[137,2cm]
PLAFOND
(MIN)
3" [76,2mm]
MINIMUM
15 5/8”
[39.7cm]
15 5/8”
[39,7cm]
2"
[50.8mm]
2"
[50,8mm]
CEILING
ENCLOSURE
PLAFOND
ENCEINTE
34 5/8"
879mm
9 1/16"
230mm
15 3/8"
391mm 4"
102mm
7"
178mm
35"
889mm
SAFETY BARRIER
24"
610mm
2 3/16"
55.5mm GAS INLET15 3/4"
400mm
8"
203mm
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0mm) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.6 3/8"
[162mm]
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.6 3/8"
[162mm]41"
[104.1cm]
10"-20"
[254mm-50.8cm]
VENT RUN
11 1/2"
[292mm]
41 "
[104.1cm]
1"-10"
[25mm-254mm]
VENT RUN
54 "
[137.2cm]
CEILING
(MIN)
Ceiling
Enclosure
W415-1886 / 10.26.18
publicité
Manuels associés
publicité