Scotsman AC 45, AC 55, AC 85, AC 105, AC 125, AC 175, AC 225 Electronic cuber Service Manual

Scotsman AC 45, AC 55, AC 85, AC 105, AC 125, AC 175, AC 225 Electronic cuber Service Manual

The Scotsman AC 45, AC 55, AC 85, AC 105, AC 125, AC 175, and AC 225 are electronic cubers designed for indoor installation and come with a storage bin for the ice they make. These models have a new PC board version and are designed to provide high-quality ice for various applications.

advertisement

Page 1Page 1
SERVICE MANUAL
AC 45
AC 55
AC 85
AC 105
AC 125
AC 175
AC 225
Electronic cubers
with storage
New PC Board version
MS 1000.81 REV. 07/2002
Page 2Page 2
Table of contents page
Specifications AC 45
Specifications AC 55
Specifications AC 85
Specifications AC 105
Specifications AC 125
Specifications AC 175
Specifications AC 225
GENERAL INFORMATION AND INSTALLATION
Introduction
Unpacking and Inspection
Location and levelling
Electrical connections
Water supply and drain connections
Final check list
Installation practice
OPERATING INSTRUCTIONS
Start up
Operational checks
OPERATING PRINCIPLES (How it works)
Freezing cycle
Harvest cycle
Control sequence
Component description
ADJUSTMENT, REMOVAL AND REPLACEMENT PROCEDURES
Adjustment of the cube size
Wiring diagram AC 45-55-85-105
Wiring diagram AC 125-175-225
Service diagnosis
MAINTENANCE AND CLEANING INSTRUCTIONS
General
Icemaker
Cleaning instructions of water system
INDICE 2
3
5
7
9
11
13
15
34
35
36
37
17
17
17
17
18
18
19
20
21
25
28
29
30
40
40
41
Page 3Page 3
Important operating requirements:
Air temperature
Water temperature
Water pressure
Electr. voltage variations
from voltage rating
specified
on nameplate
MIN.
10°C
5°C
1 bar
-10%
°C
°F
SPECIFICATIONS
ELECTRONIC CUBER MODEL AC 45
NOTE
. With the unit in "built-in" conditions, the ice production is gradually reduced in respect to the
levels shown in the graf, up to a maximum of 10% at room temperatures higher than 32°
C.
The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature and age of the machine.
To keep your SCOTSMAN CUBER at peak performance levels, periodic maintenance checks must
be carried out as indicated on page 40 of this manual.
MAX.
40°C
40°C
5 bar
+10%
ice making capacity
24
23
22
21
20
19
18
17
16
15
K g .
32 27 21 15 10
AIR COOLED MODELS
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
10
21
32
38
WATER COOLED MODELS
°Co
°Co
24
23
22
21
20
19
18
17
16
15
K g .
32 27 21 15 10
10
21
32
38
°Co
°Co
WATER TEMPERATURE
AMBIENT TEMPERATURE
ICE PRODUCED PER 24 HRS.
Page 4Page 4
Stainless steel 1/4 14 Kg.
AC 45 AS 6 Air
AC 45 WS 6 Water
Start . Electric power cons.
Amps Kwh per 24 Hr
Capacity Water req.
the cold store lt/24 HRModel Cond. unit Finish Comp. HP
SPECIFICATIONS
Basic electr. Amps Watts Nr. of wires Amps fuse
230/50/1 2.2 11 340 6.5 3 x 1.5 mm 2 10
100*
270*
AC 45 - CUBER
machine specifications
Cubes per harvest: 18 medium
* A 15°C water temperature
Dimensions:
HEIGHT 725 mm.
WIDTH 457 mm.
DEPTH 480 mm.
WEIGHT 39 Kgs.
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
  • Page 21
  • Page 22
  • Page 23
  • Page 24
  • Page 25
  • Page 26
  • Page 27
  • Page 28
  • Page 29
  • Page 30
  • Page 31
  • Page 32
  • Page 33
  • Page 34
  • Page 35
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
  • Page 41
  • Page 42
/

advertisement

Key Features

  • Electronic control
  • Ice storage bin
  • New PC Board version
  • Indoor installation
  • Multiple model sizes

Related manuals

Frequently Answers and Questions

What are the important operating requirements for Scotsman AC series icemakers?
The manual states that the minimum ambient temperature is 10°C (50°F) and the maximum is 40°C (100°F). The minimum water temperature is 5°C (40°F) and the maximum is 35°C (90°F). The water pressure should be between 1 bar (14 psi) and 5 bars (70 psi). The electrical voltage variation should not exceed -10% and +10% of the data plate rating.
What is the ice-making capacity of the AC series icemakers?
The ice-making capacity is specified on pages 3-15 of the viewed document, and it varies for each model depending on the ambient temperature, water temperature, and whether the model is air-cooled or water-cooled.
What kind of maintenance checks should be carried out periodically?
The manual suggests periodic maintenance checks as indicated on page 40 of this manual. These checks are essential for maintaining peak performance levels of the Scotsman Cubers.
What is the recommended drain tube size?
The recommended drain tube is a plastic or flexible tube with 18 mm (3/4") I.D. which runs to an open trapped and vented drain.