Ditec EL31R Gate automation, garage and industrial doors automation Installation manual
DITEC EL31R is a control panel for 24V automations with built-in radio, suitable for both sliding gates and barriers. It enables partial opening, automatic closing, safety stop, safety reopening, and safety test. EL31R has a storage module for up to 100 transmitters, and can be used with various accessories such as photocells, safety edges, and flashing lights.
advertisement
Ditec EL31R
Installation Manual for control panel for 24V automations with
built-in radio.www.ditecentrematic.com
IP1851EN
POWERSA
11IN
Limit switch
Limit switch
Accessories output
12
VA
A
VC TC R1
AUX
A
N
T
B
A
T
SAFETY24V~
1 5 9 13 20 0 1 6 8 41C NO
1112 0
14 0
PRG
COM
ENC
JR1
1
ON
2 3 4 5 6
B
1
ON
2 3 4 5 6 7 8
EL31R
SIG
-M
+M
Power supply
Step-by-step
Safety stop
Safety reopening
Stop
Safety test
Flashing light
Gate open indicator light
Partial opening
GOL4
F1
Transformer
Safety switch
24V=
Motor
BATK3
Installation Manual for control panel for 24V automations with
built-in radio.www.ditecentrematic.com
IP1851EN
POWERSA
11IN
Limit switch
Limit switch
Accessories output
12
VA
A
VC TC R1
AUX
A
N
T
B
A
T
SAFETY24V~
1 5 9 13 20 0 1 6 8 41C NO
1112 0
14 0
PRG
COM
ENC
JR1
1
ON
2 3 4 5 6
B
1
ON
2 3 4 5 6 7 8
EL31R
SIG
-M
+M
Power supply
Step-by-step
Safety stop
Safety reopening
Stop
Safety test
Flashing light
Gate open indicator light
Partial opening
GOL4
F1
Transformer
Safety switch
24V=
Motor
BATK3
28IP1851EN - 2015-11-24
29IP1851EN - 2015-11-24
Index
Subject Page
1. General safety precautions 30
2. EC declaration of conformity 31
3. Technical specifications 31
3.1 Applications 31
4. Commands 32
4.1 Self-controlled safety edge 33
5. Sliding gates outputs and accessories 34
6. Barriers outputs and accessories 35
7. Settings 36
7.1 Trimmers 36
7.2 Sliding gates dip-switches 37
7.3 Barriers dip-switches 38
7.4 Jumper 39
7.5 Signals 39
8. Radio 40
9. Working modes for sliding gates 41
10. Start-up 42
10.1 Sliding gates start-up 42
10.2 Barriers start-up 43
11. Troubleshooting 44
12. Application example for sliding gates 46
13. Application example for barriers 47
14. Example of operator present function mode 47
15. Application example for parallel automations 48
Key
i This symbol indicates useful information for the correct functioning of the product.
This symbol indicates instructions or notes regarding safety, to which special atten-
tion must be paid.
Index
Subject Page
1. General safety precautions 30
2. EC declaration of conformity 31
3. Technical specifications 31
3.1 Applications 31
4. Commands 32
4.1 Self-controlled safety edge 33
5. Sliding gates outputs and accessories 34
6. Barriers outputs and accessories 35
7. Settings 36
7.1 Trimmers 36
7.2 Sliding gates dip-switches 37
7.3 Barriers dip-switches 38
7.4 Jumper 39
7.5 Signals 39
8. Radio 40
9. Working modes for sliding gates 41
10. Start-up 42
10.1 Sliding gates start-up 42
10.2 Barriers start-up 43
11. Troubleshooting 44
12. Application example for sliding gates 46
13. Application example for barriers 47
14. Example of operator present function mode 47
15. Application example for parallel automations 48
Key
i This symbol indicates useful information for the correct functioning of the product.
This symbol indicates instructions or notes regarding safety, to which special atten-
tion must be paid.
30IP1851EN - 2015-11-24
1. General safety precautions
This installation manual is intended for qualified personnel only.
Installation, electrical connections and adjustments must be performed in accordance
with Good Working Methods and in compliance with the present standards.
Read the instructions carefully before installing the product.
Bad installation could be dangerous.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environ-
ment or left within reach of children, as these are a potential source of danger.
Before installing the product, make sure it is in perfect condition.
Do not install the product in explosive areas and atmospheres: the presence of inflammable
gas or fumes represents a serious safety hazard.
The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking
into account: applicable laws and directives, Good Working Methods, installation premises,
system operating logic and the forces developed by the automation.
Before connecting the power supply, make sure the plate data correspond to that of the
mains power supply.
An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included
in the mains supply.
Check that upstream of the electrical installation there is an adequate residual current circuit
breaker and a suitable overcurrent cutout.
When requested, connect the automation to an effective earthing system that complies with
current safety standards.
During installation, maintenance and repair operations, cut off the power supply before opening
the cover to access the electrical parts.
The electronic parts must be handled using earthed antistatic conductive arms.
The manufacturer of the motorisation declines all responsibility in the event of component
parts being fitted that are not compatible with the safe and correct operation.
Use original spare parts only for repairs or replacements of products.
1.1 Installation precautions
Fix the control panel permanently. Pass the cables along the lower side of the container.
If they are accessible, block the cables with cable glands (not supplied). Keep the line and motor
conductors separated from the command conductors by at least 8mm in the terminal boards
connection points (e.g. using straps).
Connect together the protection conductors (yellow/green) of the line and the motors, using the
clamp supplied.
At the end of the installation, close the container.
Failure to observe the information in this manual may result
in minor personal injury or damage to equipment.
Save these instructions for future reference.
1. General safety precautions
This installation manual is intended for qualified personnel only.
Installation, electrical connections and adjustments must be performed in accordance
with Good Working Methods and in compliance with the present standards.
Read the instructions carefully before installing the product.
Bad installation could be dangerous.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environ-
ment or left within reach of children, as these are a potential source of danger.
Before installing the product, make sure it is in perfect condition.
Do not install the product in explosive areas and atmospheres: the presence of inflammable
gas or fumes represents a serious safety hazard.
The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking
into account: applicable laws and directives, Good Working Methods, installation premises,
system operating logic and the forces developed by the automation.
Before connecting the power supply, make sure the plate data correspond to that of the
mains power supply.
An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included
in the mains supply.
Check that upstream of the electrical installation there is an adequate residual current circuit
breaker and a suitable overcurrent cutout.
When requested, connect the automation to an effective earthing system that complies with
current safety standards.
During installation, maintenance and repair operations, cut off the power supply before opening
the cover to access the electrical parts.
The electronic parts must be handled using earthed antistatic conductive arms.
The manufacturer of the motorisation declines all responsibility in the event of component
parts being fitted that are not compatible with the safe and correct operation.
Use original spare parts only for repairs or replacements of products.
1.1 Installation precautions
Fix the control panel permanently. Pass the cables along the lower side of the container.
If they are accessible, block the cables with cable glands (not supplied). Keep the line and motor
conductors separated from the command conductors by at least 8mm in the terminal boards
connection points (e.g. using straps).
Connect together the protection conductors (yellow/green) of the line and the motors, using the
clamp supplied.
At the end of the installation, close the container.
Failure to observe the information in this manual may result
in minor personal injury or damage to equipment.
Save these instructions for future reference.
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
advertisement
Key Features
- Control panel for 24V automations
- Built-in radio
- Step-by-step operation with automatic closing
- Opening with automatic closing
- Partial opening
- Safety stop
- Safety reopening
- Power supply
- Accessories output
- Trimmer adjustments
Related manuals
Frequently Answers and Questions
What is the power supply of the EL31R?
The EL31R has a power supply of 230 V~ 50/60 Hz.
What is the motor output of the EL31R?
The EL31R has a motor output of 24 V 8A.
What is the degree of protection of the EL31R?
The EL31R has a degree of protection of IP24D.
What is the radio frequency of the EL31R?
The EL31R has a radio frequency of 433,92 MHz.
How many transmitters can be stored in the EL31R?
The EL31R can store up to 100 transmitters.
advertisement