Koganei DTRY-ELF02 Instruction manual

Koganei DTRY-ELF02 Instruction manual

advertisement

POWER
.H V
ALARM
DTRY-ELF02
POWER&SIGNAL
ALARM ALARM

DC
+24V
0V
MADE IN JAPAN

ALARM
NO NC

FLOW

Backside fan guard

Konb bolt

Grounding
terminal

Contact a or b
selector switch

Connector

Mounting hole for
conponent bracket

Bracket

Power switch

Abnormality indicator(red LED)

High-voltage power supply indicator(green LED)

Airflow adjustment
knob

Louver for direct air advance

MOLEX#5569-04A

Mounting hole for bracket(3-O4.5)

FLOW

NCNO
ALARM

MADE IN JAPAN
0V +24V
DC
ALARMALARM
POWER&SIGNAL
DTRY-ELF02
ALARM
H V.
POWER

Discharge needle unit

Discharge needle

Bracket fixing hole

Filter cover

Main unit fixind screw
2-M3x0.5

この保護シールは接点設定後
必ず切り替えスイッチ用窓に
貼り付けてください

NCNO
ALARM

MADE IN JAPAN
0V +24V
DC
ALARMALARM
POWER&SIGNAL

ALARM
NO NC

Instruction Manual

Steady-Flow Fan-type Ionizer

[DTRY-ELF02]

Thank you very much for your purchase of DTRY-ELF02 (hereinafter referred to as
ELF02). Although this Product is not classified as a high-voltage device under any
electrical equipment standard, it uses a high voltage of 2000 V. Please read this
manual diligently to carefully and correctly handle this unit. Keep this manual on hand
for your reference and consult it repeatedly as required.

1. Safety Precautions

This Product has been designed, tested, and shipped out in accordance with the
Safety Requirements for Electrical Equipment under IEC61010-1. Because a
high voltage is use inside the Unit, improper use of this unit may cause an
accident resulting in injury or death, or may lead to a malfunction of the Product.
Our company shall not be held liable for any usage outside the Product
Specifications or any accident caused by noncompliance with the Safety
Precaution.

1.1 Warning

This Product is not specified as an Explosion-proof Type. Do not use this unit at a
location or an atmosphere, in which combustible gas or solvent is handled, or else
ignition or explosion may occur.

A high voltage is applied to the Discharge Needle. Do not allow any conductive
material, including your finger, any part of your body, wire or any tool to get close to
the Needle, or an electrical shock

accident or a malfunction of the Unit may occur.

The Discharge Needle has a sharp edge. Pay special attention to handling of the
Needle, or you may injure yourself.

Do not use this unit outside the scope of the specifications, or else an accident or a
malfunction of the Unit may be caused, or the service life of the Product may be
extremely reduced.

Never disassemble, repair, or remodel this unit, or else an accident or a malfunction
of the Unit may occur.

This Product will cause ozone to be generated in the atmosphere. If you perceive
any smell of ozone, make sure to clear the air in the room and keep good ventilation
in the room. If ozone should remain in the air for long, it may cause metal parts to
be oxidized.

When any wiring, installation, or inspection work is to be carried out, make sure that
the Unit is disconnected from the power supply, or else an accident, an electrical
shock or a malfunction may be caused.

To ensure that the Unit should maintain its performance, be sure to regularly clean
the surrounding area of the discharge area. If the area is not maintained in a clean
condition, not only the Unit will not be able to work up to the optimum performance
but the equipment and work pieces may get damaged.

For any other Items of Warning, please refer to the Safety Precaution in the Static
Electricity Elimination Unit; Ionizer Catalog (Catalog No. C2167).

1.2 Caution

This Product contains a high-voltage generating device inside the Unit. Do not
install the Unit at a location where it may be exposed to splashing of water or oil,
high temperatures, or excessive humidity. Make sure the Unit is protected from
condensation.

Make sure that the Unit is protected from being exposed to any transitional condition
of the power supply . Make sure that the input power supply will stay within the
specified rating.

Make sure that any unserviceable unit or any unnecessary unit should be properly
disposed of as an industrial waste material.

For any other Items of Precaution, please refer to the Safety Precaution in the Static
Electricity Elimination Unit; Ionizer Catalog (Catalog No. C2167).

2. Contents of the Product Set

When this Product has been delivered to your site, check the package for any
missing part or for any abnormality or damages that may have occurred during
delivery before using the Unit. In case any damage should be found or any
abnormal operation should be observed, please contact the shop where you
purchased the Product (the agency), or the nearest service station of our
company.

2.1 Contents of the Package

Main unit 1unit Instruction Manual (this booklet) 1booklet

Direct air advance Louver* 1piece
Wide angle Louver 1pieceDischarge unit* 1unit

Filter cover* 1piece
Mounting Bracket* 1setPower supply signal cable (2 m) 1line

Grounding Lead Wire (2 m) 1line Backside Filter 1sheet
Discharge needle Cleaning Brush 1piece
Contact selector switch protection seal 1sheet

*Attached to the Main Unit before shipment.

2.2 Consumable Items

To maintain the optimum performance of this unit, it is recommended that
consumable items should be regularly replaced.

Discharge needle unit: DTRY-ZEM-F02

Backside Filter (a set of 5 sheets)DTRY-ZFR-F02

3. Product Overview

This Product is a fan-type ionizer (static electricity eliminating device) capable of
immediately solving any problems that occur in connection with static electricity.
By using ionized air it generates, the Unit can promptly and efficiently eliminate
the static electricity charged on electrified bodies.

4. Specifications

4.1 List of Specifications

Type
DTRY-ELF02
Input Power Source
DC24V±5
Current Consumption
mA

240

Output Voltage V
2 (High-frequency type)
Displays
High voltage LED (green); Discharge abnormality
indication LED (red); Power switch LED (Illumination
push-button switch: green)

Abnormal Output
Contact output at a time of abnormality of discharge
(setting of contact A or B possible)

DC24V 50mAMAX

Outside Dimensions

mm

61(L)×80(W)×100(H)

(with Bracket and Filter not attached; not including
protruding parts)

Mass g
Approx. 650 (with Bracket and Filter not attached)
Ion Balance

V

±10

(at 300 mm from the center of the blow-out opening;
at maximum airflow)

Generated Ozone
Volume

ppm

0.04or less

(at 300 mm from the center of the blow-out opening;
at maximum airflow)

Airflow m3
/min
0.5 Max. (step-less adjustment possible)
Environmental
Temperatures


040

(no condensation allowed in the room)

4.2 Appearance

5. Installation/Wiring

5.1 Setting of Contacts for Abnormal Output

This Product permits selecting of the Contact for the abnormal signal output
(contact A or B: contact A specified before shipment). Refer to the setting
procedure to make the correct setting.

Setting Procedure

Confirm that the Cable is not connected to the Connector on the Backside of
the Main Unit. If connected, disconnect the Cable.

Shift the NO (contact A)/NC (contact B) Selector Switch on the backside of the
Main Unit to the desired position by using a precision screw driver, etc.

Caution

Do not apply excessive force when making adjustments to the Switch, or else
you may damage the Product.

Make sure that the Switch position is positively shifted. The device will not
operate normally if the Contact is not correctly connected.

Connect the Cable to the connector on the backside of the Main Unit.
Supply the power to the Product to confirm that the Contact operates normally.
See the table below for the outputs when setting the Contacts.

SETTING MODE
POWER OFF POWER ON
NO (Contact A)
OPEN OPEN
NC (Contact B)
OPEN CLOSE
Caution

Be sure to confirm the operations of the Contacts. If the confirmation is not
properly carried out, any unexpected operation of the Device may cause an
accident resulting in physical injury or a malfunction of the Product.

Refer to Section 5.5 “Wiring” for confirmation of operation to ensure that the
Product operates normally. Incorrect polarity setting of the power supply
may cause a malfunction of the Product.

After the Contact setting is completed, be sure to seal the window for NO
(Contact A) / NC (Contact B) Contact Selector Switch, using the Contact
Switch Protection Seal supplied with the Product.

Caution

Be sure to carry out the sealing, or else erroneous operation or a malfunction of
the Unit may occur.

5.2 Selection of Louver

As accessory items, this Product is shipped out with 2 types of Louvers: Direct
Air Advance (attached as standard before shipment) and Wide Angle Louver
types. Select the type most appropriate and efficient for the area from which
you are intending to eliminate the static electricity.

<Feature of the Direct Air Advance Louver>

This Louver is designed to allow the air to advance directly forward. It allows
the Product to powerfully eliminate the static
electricity immediately in front of Product.

<Feature of the Wide Angle Louver>

This Louver permits the air to spread over a
wide area to eliminate the static electricity
there. Because the air spreads over a wide
area, however, this Louver somewhat
reduces the overall static elimination

effect of the Product.

<Diagram Showing the Scope of Static Elimination>

Procedure for Exchanging the Louver

Confirm that the Cable is not connected to the Connector on the Backside of the
Main Unit. If connected, disconnect the Cable.

While firmly pressing down the Main Unit to hold it in position, push the bottom of
the Louver upward. The Louver will slide upward. While pulling the Finger
Grip at the top of the Louver, pull and remove the Louver from the Main Unit.

Caution

If the Louver is removed, the Discharge Needle will be exposed. Be especially
careful not to touch the Needle, or else you may get injured. Also, if the Needle
should be bent or be broken, the optimum performance of the Unit cannot be
expected. In case the Needle is bent or damaged, replace it with a new set of
Discharge Needle DTRY-ZEM-F02 (consumable item: separately available).

Prepare the new Louver to replace the old one. While firmly holding the
Main Unit in position, insert the new Louver from the lower side of the Main
Unit and push it upward until the 4 claws on the Main Unit engage with the
receptacles on the Louver. Confirm that they are mutually engaged, and
then push the Finger Grip at the top of the Louver downward until it clicks in
place.

Caution

If no Louver is attached to the Main Unit, the power will not be supplied to the Main Unit
even when the Switch is turned on.

Make sure that the Louver is correctly installed. Otherwise, it is possible that the
power is not supplied to the Main Unit, or the optimum performance of the
Product cannot be achieved.

5.3 How to Attach a Filter on the Backside of the Main Unit

Depending on the environment you use this Product; it may be required for you to
attach a Filter on the backside of the Main Unit. It should be noted, however, that
the performance of the Product for eliminating the static electricity would be slightly
reduced in comparison to the time when the Filter is not used.

Confirm that the Cable is not connected to the connector on the backside of the
Main Unit. If it is connected, disconnect the Cable.

While securely holding down the Main Unit in position, remove the Filter Cover.
The Filter Cover may be easily removed by gripping the side of the Filter Cover
and pulling it toward you.

Place the Backside Filter (an accessory item) in place in the Filter Cover, and
attach them onto the Main Unit.

Caution

Make sure that the Filter Cover with the Filter is securely engaged in the Main
Unit. If it is not securely installed in place, the Filter Cover may be disengaged
and become detached from the Main Unit while the Product is in operation.

5.4 Installation

Caution

Do not install or use the Product on the surface of any device that contains on
moving part, where it may be subjected to violation or shocks. The Product may
possibly be damaged.

The Product is not specified to be installed in any specific orientation. Make sure,
however, that the surface on which the Product should be installed is perfectly level
and not inclined in any direction.

Provide a space of 100 mm or more in front of the Air Inlet of the Product, whether
Product is to be installed. If any obstacle for air intake exists near the Air Inlet, the
sufficient amount of air will not be supplied to the Unit, preventing the Product from
operating up to its full performance. This may also lead to a malfunction of the Fan.

Do not install the Product at the location where dew condensation may occur or
where it may be exposed to extremes of temperatures and/or humidity. It is
possible that the Product should get damaged.

Louver finger grip

*Time required for static elimination under maximum
airflow from ±1000 V to ±100 V (according to the
measuring condition specified by our company).
The scope of static elimination is only for reference.
The scope of static elimination is shown for one side

Lo
uver finger grip
Direct air advance louve
r Wide angle louver
ALARM
NO NC

NCNO
ALARM

POWER&SIGNAL
ALARM ALARM

DC
+24V0V
MADE IN JAPAN

ALARM
NO NC

100 300 600 900 1200

Distance mm

300

200

100

0

Lateral distance

ELF02+Wide Angle Louver

ELF02+Direct Air Advance Louv
er
Distance mm

100 300 600 900 1200

300

200

100

0

Lateral Distance

~2s
~4s

~6s

~8s

~10s

~12s
Ver.2.0
How to Install the Product using the Mounting Bracket

The Product may be used by
placing it on a horizontal surface
such as a tabletop. It may also
be used as a component of a
system, being installed on a piece
of equipment. Use the Mounting
Bracket in this case by fastening it
to the equipment with M4 Set
Screws (including spring washers
and washers) (See the diagram).

The angle of the Main Unit may be freely adjusted by loosening the Knob Bolt.
After the adjustment is completed, be sure to tighten the Knob Bolt again to
ensure that the angle of the Main Unit will stay unchanged.

Caution

Make sure that the height of Screws (including washers) from the surface of the
Bracket is 8 mm or less. Otherwise the Screws may interfere with the Main Unit
when its angle adjustment is performed.

How to Install the Product Using the Complement Bracket

(DTRY-ELF31)

Fasten the Component Bracket (type DTRF-ELF31) onto the backside of the
Main Unit by inserting 2 Dedicated Bolts (supplied with the Component
Bracket) into the Mounting Holes for the Component Bracket on the backside
of the Main Unit and tightening the Bolts.

Caution

Use of any other bolts than the dedicated type is not permitted. Any other type,
if used, may damage the internal part of the Main Unit.

How to Install the Product Using Other Methods

If the Product is to be installed directly on a piece of equipment, remove the
Bracket, and fasten the Unit to the equipment by screwing 2 M3×0.5 Screws
into Mounting Holes on the bottom of the Main Unit.

Caution

Make sure that the Screws to be used will not enter the Main Unit by 5 mm or
deeper. Otherwise the Main Unit may be damaged.

5.5 Wiring

Caution

When performing any wiring work, be sure to confirm the Colors of Wires to be
used, and carry out the wiring in the secure and correct manner. Wrong wiring
may cause damages to the Main Unit.

Make sure that the rated Power Supply Voltage is supplied to the Product. Do
not use any power supply that may be subject to voltage variations. If used,
such power supply may degrade the performance of the Product.

How to Connect to Wiring for Power Supply and Abnormal Output Contracts

Connect the supplied the Power Supply Signal Cable to the connector on the
backside of the Main Unit.

Connect the + 24 V line of the DC Power Supply to the "red" line, and 0 V line
to the "green" line of the Power Supply Signal Cable, respectively.

If the Abnormal Output Contacts are to be used, connect the Contacts to the
“white” and “black” lines of the Power Signal Cable. No polarity is involved
with the connections in this case.

Caution

Make sure that the connections are carried out in a secure manner by using a
Terminal Block or Crimp- Style Terminals, etc. Otherwise, there is a danger
that the Main Unit may get damaged.

If the Abnormal Output Circuits are to be used, make sure the Circuits are used
within the rated specification range (24 VDC; 50 mA, max.).

See the diagram below for the Abnormal Output Circuits.

The Abnormal Output Circuits will start working about 2 seconds after the power
is turned on. Pay special attention when designing the Abnormal Detection
Circuits when this Product is to be built into a system.

If no Abnormal Output Circuits are to be used, be sure to carry out some
appropriate measures for insulating the "white" and "black" tail ends of the
supplied Power Supply Signal Cable. Otherwise, there is a possibility that the
Main Unit get damaged.

How to Ground the Wiring

Connect the round terminal of the supplied Grounding Lead Wire to the g
rounding terminal located on the backside of the Main Unit.

Connect the terminal at the opposite end of the Grounding Lead Wire to the
Grounding Point.

Caution

Confirm that the Grounding Point is properly grounded. If it is not, be sure to
carry out the Grounding Procedure (according to the 3rd class procedure).

The Product must be properly grounded. The Product may not be able to work
up to the fullest performance.

6. Operation

6.1 Operations When Turning ON the Power

Check the Product to confirm that the setting and wiring have been carried out
in accordance with the instructions given under Section 5 "Installation/Wiring"
in this manual.

Turn ON the Switch on the DC power supply.

Press once the Power Switch (push-button type) located on the front of the
Product. The power will be supplied to the Product. If the Unit is operating
normally, both the Power Switch and High-voltage Power Supply LED (green)
located on the front side of the Product will light up.

In accordance with the distance to the charged object and the amount of static
electricity charged on the object, adjust the Airflow Adjustment Knob to provide
the appropriate amount of airflow.

Caution

If the Power Switch of the Unit or the High-voltage LED does not light up, or if
the Alarm Display on the front of the Unit lights up, immediately turn off the
power from the Unit. Then, check the installation and wiring against the
instructions given under Section 5 "Installation/Wiring". In case you cannot
solve the problem even then, please refer to Section 7 "Maintenance" and
Section 8 " Troubleshooting".

6.2 Operations When Turning OFF the Power

Press once the Power Switch (push-but the type) located on the front of the
Product. Both the Power Switch and their high-voltage LED on the front of the
Product will go off.

7. Maintenance

Warning

Maintenance is an extremely important factor for achieving the optimum
performance of the Device. Be sure to carry out the maintenance work on a
regular basis.

Before you perform the maintenance work, make sure that the Power Supply
Cable has been disconnected.

When you are using solvent such as alcohol, make sure that the room is well
ventilated. And if you have used alcohol for cleaning, make sure that all
alcohol has evaporated and no part on the Main Unit is wet with alcohol.

The tip of the Discharge Needle is pointed. When removing or cleaning the
Discharge Needle Unit, pay special attention to the Needle Unit, or else you
may injure yourself. Be careful not to cause the Discharge Needle to be bent
or broken, otherwise the performance of the Unit may be greatly degraded.

7.1 How to Clean the Discharge Needle

Confirm that the Cable is not connected to the Connector on the Backside of
the Main Unit. If connected, disconnect the Cable.

Remove the Louver by referring to Section 5.2 where the procedure for
exchanging Louvers is explained.

Soak the supplied Discharge Needle Cleaning Brush in anhydrous alcohol

such as isopropyl alcohol. Use the Brush to remove the foreign articles

attached to the tip of the Discharge Needle.

If the plastic part of the Discharge Needle Unit or the surrounding plastic

part is soiled, moisten a piece of waste cloth with anhydrous alcohol such as

isopropyl alcohol and wipe off the soiled surfaces with the cloth.

Attach the Louver to the Main Unit by

referring to the procedure for exchanging the Louver described under Section
5.2 of this manual.

7.2 How to Replace the Discharge Needle Unit (DTRY-ZEM-F02)

The material used for the Discharge Needle of this Product is tungsten. Tungsten as
the material for Discharge Needles is very durable and will not wear off easily. If the
Product is regularly maintained in a normal manner, almost no degradation of the
performance will be observed. In case, however, contamination cannot be removed
due to negligence of maintenance or the Needle is bent or damaged due to an
accident, etc., replace the entire Discharge Needle Unit with a new one.

Confirm that the Cable is not connected to the Connector on the Backside of
the Main Unit. If connected, disconnect the Cable.

Remove the Louver by referring to Section 5.2 where the procedure for
exchanging Louvers is explained.

While securely holding down the Main Unit in place, remove the Discharge
Needle Unit by gripping the Finger Grip at the center of the Discharge Needle
Unit and turning it in the direction of FREE (clockwise), and releasing the Unit.

Prepare a new set of Discharge Needle Unit.

While securely holding down the Main Unit, grip the Finger Grip of the
Discharge Needle Unit with your fingers. Align the protrusion on the Main Unit
in the section to be engaged with the Discharge Needle Unit with the engaging
section on the Discharge Needle Unit. Press the Discharge Needle Unit into
the Main Unit, so that both units will be engaged with each other. Turn the
Discharge Needle Unit in the LOCK direction (counterclockwise) until the
Discharge Needle Unit is securely locked with the Main Unit.

Caution

Turn the Discharge Needle Unit until the Confirmation Mark on the Unit is
aligned with the Mark on the rib section of the Fan. The correct installation of
the Discharge Needle Unit on the Main Unit is essential for the optimum
operation of the Product.

When you are removing the old Discharge Needle Unit and installing a new one,
pay special attention to the FREE and LOCK turning directions.

When you are turning the Discharge Needle Unit, be sure not to apply an
excessive force. Otherwise, you may cause damage to the Main Unit.

Do not disassemble the Discharge Needle Unit. The tip of the Discharge
Needle is sharply pointed. It is possible that you may injure yourself.

Install the Louver by referring to "the Procedure for Exchanging the Louver"
under Section 5.2 in this manual.

7.3 How to Clean the Filter Cover and to Exchange the Backside Filter (DTRY-
ZFR-F02)

Caution

The Backside Filter is a consumable item. When deterioration of the Backside
Filter is observed, replace it with a new one.

When the Filter Cover is soiled or the Backside Filter is clogged, the Product
cannot achieve its full performance. Be sure to carry out regular maintenance.

Confirm that the Cable is not connected to the Connector on the Backside or
the Main Unit. If connected, disconnect the Cable.

Remove the Filter Cover by following the procedure described under Section
5.3 “How to Attach a Filter on the Backside of the Main Unit”.

Wash and clean the soiled or clogged Filter Cover and the Filter using neutral
detergent. After cleaning, be sure to completely dry the Filter Cover and the
Filter.

Caution

Incomplete drying of the Filter or the Filter Cover may lead to degrade the
performance of the Main Unit. Be sure to use the Product after the Filter and
the Filter Cover a completely dried.

Insert the newly prepared Backside Filter into the Filter Cover, and install the
Filter Cover with the Filter on the Main Unit.

Caution

Make sure that the Filter Cover with the Filter is securely engaged in the Main
Unit. If it is not securely installed in place, the Filter Cover may be disengaged
and become detached from the Main Unit while the Product is in operation.

7.4 Inspection

Check the Power Supply Signal Cable to confirm that there is no deterioration
or breaking in the installation.

Check the power supply voltage and the width of its variation to ensure that
they are within the specified range.

Check the Main Unit to confirm that there is no unknown low noise generated
from the Unit.

8. Troubleshooting

In case any abnormal condition is observed in this Product, immediately turn of
the power from the Main Unit. Disconnect the Cable from the Connector on the
Backside or the Main Unit. Then, read this Section carefully and follow the
instructions. If the abnormality cannot be solved even after that, please contact
the shop where you purchased the Product (the agency), or the nearest service
station of our company.

Symptom

The power cannot be supplied to the Unit. (All indicators do not light up at all,
and the Fan does not turn.)

Contents to be Confirmed

Check the DC power supply unit to confirm that the power is turned ON.

In case you are using an AC adapter, check to see if the AC plug is securely
inserted into the wall outlet.

Check the input voltage to confirm that it is within the specified range.

Check the Power Signal Cable to confirm that the wire is not broken.

Check the Power Signal Cable to confirm that the wiring has been correctly
performed.

Check the Louver to confirm that it is correctly installed.

Symptom

The abnormality indications LED lights up.

Contents to be Confirmed

The Discharge Needle may be soiled or damaged. Carry out the
maintenance work for the Discharge Needle Unit in accordance with the
instructions given under Section 7 “Maintenance”.

Check the Discharge Needle Unit to confirm that the Discharge Needle Unit
has been securely installed.

Symptom

No elimination of the static electricity is performed.
Contents to be Confirmed
The Discharge Needle may be soiled or damaged. Carry out the
maintenance work for the Discharge
Needle Unit or replace the Unit with a new one in accordance with the
instructions given under Section 7 “Maintenance”.

Symptom
The Abnormal Output Circuit is not workable.

Contents to be Confirmed
Carry out the setting of the NO (contact A)/NC (contact B) Contact Selector
Switch once again in accordance with 5.1 “Setting of Contacts for Abnormal
Output” in this manual.

Caution

T
he Abnormal Output Circuits will start working about 2 seconds after the power is
turned on. Pay special attention when designing the Abnormal Detection Circuits
when this Product is to be built into a system.

Symptom

The Power Switch LED lights up but the High-voltage Power Supply LED and
the abnormal indicator LED do not light up.

The Power Switch LED lights up but the Fan does not turn.

Contents to be Confirmed

It is possible that the Product is broken down. Please contact the shop where
you purchased the Product (the agency), or the nearest service station of our
company.

*Please understand that the appearance and the specifications of this Product may
be altered without advance notice for improvements.

Any other abnormal condition
If any other abnormal condition than above has been observed, immediately turn
OFF the power from the Product, and please contact the shop where you
purchased the Product (the agency), or the nearest service station of our
company.

JUST CONSULT US

KOGANEI CORPORATION

OVERSEAS DEPARTMENT

3-11-18 Midori-cho, Koganei-shi Tokyo 181-8533, JAPAN

Internet Home Page URL:
http://www.koganei.co.jp
TEL: 042-383-7271 FAX:042-383-7276

Finger grip on the
Discharge Needle Unit

POWER
.H V
ALARM
DTRY-ELF02

FLOW

POWER
.H V
ALARM
DTRY-ELF02

FLOW

Protrusion in the
engagement section

ABS

Engagement section in the
Discharge Needle Unit

FLOW

DTRY-ELF02

ALARM
H V.
POWER

Finger grip on the
Discharge Needle Unit
Mark for confirmation
FLOW

DTRY-ELF02

ALARM
H V.
POWER

Discharge Needle
(6 needles)

Discharge Needle
Cleaning Brush

the unit is to be
installed

Bracket

M4 washer

M4 spring washer

M4 screw

50mA

MAX DC24V
  • Page 1