Koganei Solenoid Valve F Series Owner's Manual

Koganei Solenoid Valve F Series Owner's Manual

Koganei Solenoid Valve F Series is an EtherNet/IP compliant, serial transmission compatible manifold designed for use with F10 and F15 Series solenoid valves. It offers flexible I/O data allocation, multiple network topology options, and robust CIP object support. The device incorporates web page access for internal status monitoring, ensuring efficient control and monitoring. The device includes safety features like the HOLD/CLEAR switch, providing a reliable solution for a wide range of applications. Please refer to the detailed documentation for complete specifications and operational guidelines.

advertisement

Document No. BK-HV045
EtherNet/IP Compliant

Serial Transmission Compatible Manifold

Supported solenoid valves

F10 Series
F15 Series
User's Manual

Ver.4.0
User's Manual
EtherNet/IP Compliant

This user's manual describes the serial transmission block so that the serial

transmission compatible manifold and solenoid valves can be used correctly. See the

catalogs for information about the manifolds and the valves.

To use these products correctly, you must first read the documentation.

ODVA, CIP, CompoNet, ControlNet, DeviceNet, and EtherNet/IP are trademarks of

ODVA.

The company and product names mentioned in this document are the trademarks of

their respective companies.

This product does not have the appropriate functions to suppor t

applications, such as safety equipment or accident prevention systems,

that require high levels of safety.

• Do not put the communication cables near or in bundles with power lines.

This manual is for the F10 and F15 series solenoid valves. Contact us if

you are using a different series of solenoid valves.

For details and precautions regarding EtherNet/IP, refer to the manuals

and other documentation about EtherNet/IP related equipment.

CAUTION

Serial Transmission Compatible Manifold
1 Solenoid Valve F Series
EtherNet/IP Compliant

1 Contents
1 Contents..............................................................................................................1
2 Revision History .................................................................................................... 3
3 Glossary ..............................................................................................................3
4 Major Parts and Functions ......................................................................................5
4-1 Power, communications, and FG connectors ........................................................5
4-2 Indicator panel ...............................................................................................5
4-3 Hardware switch settings .................................................................................6
4-3-1 Network address setting switch, HOLD/CLEAR switch ...................................... 6
4-3-2 Host address setting switch ........................................................................ 6
5 EDS file ...............................................................................................................7
6 IP address settings................................................................................................7
6-1 Specify using the host address switches .............................................................7
6-2 Use the DCHP server .......................................................................................8
6-3 Upload from a flash memory .............................................................................8
7 Relationship between I/O data allocation and solenoid valves ...................................... 9
8 Network topology................................................................................................ 10
8-1 Line format .................................................................................................. 10
8-2 Star format .................................................................................................. 10
8-3 Device level ring format ................................................................................. 11
9 CIP class objects................................................................................................. 11
9-1 Identity (class code: 01 hex) .......................................................................... 11
9-1-1 Service code ........................................................................................... 11
9-1-2 Attribute ................................................................................................ 12
9-1-3 Reset service .......................................................................................... 12
9-2 TCP/IP interface (class code: F5 hex) ............................................................... 13
9-2-1 Service code ........................................................................................... 13
9-2-2 Attribute ................................................................................................ 13
9-3 Ethernet Link (class code: F6 hex) ................................................................... 15
9-3-1 Service code ........................................................................................... 15
9-3-2 Attribute ................................................................................................ 15
9-4 Device Level Ring (class code: 47 hex)............................................................. 16
9-4-1 Service code ........................................................................................... 16
9-4-2 Attribute ................................................................................................ 16
9-5 Quality of Service (class code: 48 hex)............................................................. 17
9-5-1 Service code ........................................................................................... 17
9-5-2 Attribute ................................................................................................ 17
9-6 Discrete Output Point (class code: 09 hex) ....................................................... 17
2 Solenoid Valve F Series
EtherNet/IP Compliant

9-6-1 Service code ........................................................................................... 17
9-6-2 Attribute ................................................................................................ 17
9-6-3 About the number of outputs .................................................................... 18
9-7 System Information (class code: B0 hex) ......................................................... 19
9-7-1 Service code ........................................................................................... 19
9-7-2 Attribute ................................................................................................ 19
10 Web page ........................................................................................................ 20
10-1 How to use ................................................................................................. 20
11 Specifications ................................................................................................... 21
11-1 General specifications .................................................................................. 21
11-2 Communication specifications........................................................................ 21
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
  • Page 21
  • Page 22
  • Page 23
  • Page 24
/

advertisement

Key Features

  • EtherNet/IP compliance
  • Serial transmission compatibility
  • F10 & F15 Series support
  • Flexible I/O allocation
  • Multiple network topologies
  • CIP class objects
  • Web page access
  • HOLD/CLEAR switch

Related manuals

Frequently Answers and Questions

What solenoid valve series are compatible with this manifold?
The manual mentions that this manifold is specifically for the F10 and F15 series solenoid valves. Contact the manufacturer for information about compatibility with other series.
How do I set the IP address?
There are three methods for setting the IP address: specifying it using the host address switches, using a DHCP server, or uploading from a flash memory. It is recommended to use the host address switches for visual confirmation of the settings.
What is the relationship between I/O data allocation and solenoid valves?
The allocation of I/O data depends on the wiring specifications of the manifold. ‘Blank’ (packed wiring) specifies wiring according to the valve specifications. ‘-W’ (double wiring) assigns all wiring for double solenoids, regardless of the valve specifications.

advertisement