Koganei GS6 Series is a digital pressure switch offering comprehensive pressure monitoring and control capabilities. Featuring a user-friendly interface, it enables pressure setting with accuracy and allows selection of output modes for tailored applications. The device features various functions such as auto-reference for precise pressure measurement, remote zero adjustment for flexible control, and peak/bottom hold for monitoring pressure variations. The GS6 series is ideal for applications requiring precise pressure sensing and control in industrial settings, including automation, process control, and general manufacturing.

advertisement

DIGITAL PRESSURE SWITCHES
GS6 Series
INSTRUCTION MANUAL Ver.4
Thank you very much for using KOGANEI pressure switches. Please read this Instruc-
tion Manual carefully and thoroughly for the correct and optimum use of the pressure
switch. Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-
tion applicable in each region or country.
This product is designed for use with non-corrosive gas. It cannot be used for liq-
uid or corrosive gas.
A product intended for use in Japan conforms to the Japanese Measurement Act.
Do not use a product intended for use overseas in Japan.
1 PART DESCRIPTION
Output 1 operation
indicator
Lights up when com-
parative output 1 is ON
Output 2 / analogue
voltage / current out-
put operation indicator
Standard type:
Lights up when com-
parative output 2 is ON
High-function type:
Lights up when analogue
voltage / current output is set
Mode selection key
Unit display
(Note 1, 2)
Main display
Sub display
Setting value
DOWN key
Setting value UP key
Connection
connector
Pressure port
GS6 type and GS6-1W/2W type:
R1 /8 + M5 female screw
GS6-F11/F11P type:
NPT1 /8 male screw+ M5 female screw
Notes: 1) In the case of a model that is intended for use outside Japan, attach the unit switch plate corresponds to the set
pressure unit.
2) The product for use inside Japan can be set only to “MPa” or “kPa”.
2 PIPING
When connecting a commercial coupler to the pressure
port, attach a 12mm spanner to the pressure port’s
hexagon section to fix the port, and then tighten with a
tightening torque of 9.8N·m or less (M5 female: 1N·m or
less). The commercial coupler or pressure port section
will be damaged if the tightening torque is excessive.
Wrap sealing tape around the coupler when connect-
ing to prevent leaks.
12mm spanner
3 MOUNTING
The sensor mounting bracket GS6-B is available as an option. When mounting the sensor
onto the sensor mounting bracket, etc., the tightening torque should be 0.5N·m or less.
M3 (length 6mm) screws
with washers
(Accessory with GS6-B)
Sensor mounting bracket
GS6-B (Optional)
The part for panel mounting GS6-P (optional) is also available.
Part for panel mounting
GS6-P (Optional)
Panel cut-out size
(Unit: mm)
31 0
- 0.4
31 0
- 0.4
4 WIRING
Connection method
Insert the accessory cable with connector into
this product’s connection connector section
as shown in the right figure.
Disconnection method
Pressing the release lever of the cable with
connector, pull out the connector.
Cable with connector
(Accessory)
Release lever
<Recommended product>
Contact: SPHD-001T-P0.5
Housing: PAP-04V-S
[JST Mfg. Co., Ltd.]
Note: Do not pull by holding the cable without pressing the release lever, as this can cause cable break or connector
break.
<Connection connector pin arrangement>
1 2 3 4
Connector pin No. Terminal name
1 +V
2 Comparative output 1
3 Standard type: Comparative output 2
High-function type: Analogue voltage / current output or external input
4 0V
5 I/O CIRCUIT DIAGRAMS
NPN output type
Standard type
Main circuit
(Brown) +V
(Black)
Comparative output 1
(White) Comparative output 2
(Blue) 0V
Load
Load
100mA max.
100mA max.
+ 12 to 24V DC
±10%-
High-function type
Main circuit
(Brown) +V
(White)
Analogue voltage / current output
or external input (Notes 1, 2, 3)
(Black)
Comparative output 1
(Blue) 0V
Load
100mA max.
5V
1kΩ + 12 to 24V DC
±10%-
PNP output type
Standard type
Main circuit
(Brown) +V
(Black) Comparative output 1
(White)
Comparative output 2
(Blue) 0V
Load
Load
100mA max.
100mA max.
+ 12 to 24V DC
±10%-
High-function type
Main circuit
(Brown) +V
(White)
Analogue voltage / current output
or external input (Notes 1, 2, 3)
(Black)
Comparative output 1
(Blue) 0V
Load
100mA max.
1kΩ
+ 12 to 24V DC
±10%-
Notes: 1) When the analogue current is output, the output load resistance should be 250Ω max.
2) Take care that when the analogue current is output, 5V or more voltage generates.
3) When using the analogue voltage output, be careful to the input impedance of the connected device.
Furthermore, note that if the cable is extended, the cable resistance will cause the voltage to drop.
6 OUTPUT MODE AND OUTPUT OPERATION
The EASY mode, hysteresis mode or window comparator mode can be selected as
the output mode for comparative output 1 and comparative output 2.
Refer to <Comparative output 1 / 2 output mode setting> in “ 8 MENU SET-
TING MODE” for details.
EASY mode
ON / OFF of the comparative output is controlled in this mode.
Pressure
P
0
ON
OFF
Comparative
output
H (Hysteresis) H: Hysteresis fixed (Note 1)
Notes: 1) Hysteresis can be fixed in 8 steps.
Refer to <Hysteresis fixed value selection> in “ 9 PRO MODE” for setting.
2) “ ” is displayed for comparative output 1 and “ ” for comparative output 2 on the sub-display.
Hysteresis mode
The comparative output ON / OFF state can be controlled with randomly set hyster-
esis in this mode.
0
Pressure
Comparative
output
H (Hysteresis)
Hi
Lo
ON
OFF
H: 1digit or more
2 digits or more when
using psi unit
Note: ” or “ ” is displayed for comparative output 1 and “ ” or “ ” for comparative output 2 on the sub-display.
Window comparator mode
In this mode, the ON or OFF state of the comparative output is controlled with a
pressure in the set range.
H: Hysteresis fixed (Note 1)
0
Pressure
Comparative
output
H (Hysteresis)
H (Hysteresis)
Hi
Lo
ON
OFF
Notes: 1) Hysteresis can be fixed in 8 steps.
Refer to <Hysteresis fixed value selection> in “ 9 PRO MODE” for setting.
2) “ ” or “ ” is displayed for comparative output 1 and “ ” or “ ” for comparative output 2 on the
sub-display.
3) Set the interval between the Lo side and Hi side to hysteresis fixed value or more.
7 RUN MODE
Setting the threshold value
Refer to <Comparative output 1 / 2 output mode setting>, <Analogue voltage / current
output / external input selection> in “ 8 MENU SETTING MODE” for setting conditions.
The Sub display conducts the threshold value. Main display does not changed.
Comparative output 1
Comparative output 2
Comparative output 1
Comparative output 2
Comparative output 1
Comparative output 2
EASY mode
(Comparative output 2 is OFF)
EASY mode
Hysteresis mode / Window
comparator mode · Lo side
Hysteresis mode / Window
comparator mode · Hi side
(Note 3)
Press: Increase threshold value to high pressure side.
Press: Decrease threshold value to low pressure side.
Automatic
Display is changed by pressing down.
(Note 2)
Blinks alternately
Notes: 1) If the set pressure range is exceeded, (exceeds the upper limit) or (exceeds the lower limit) will
appear on the sub display. will also appear if the Hi side threshold value exceeds the Lo side threshold
value when setting the “hysteresis mode / window comparator mode” threshold value.
2) Auto-reference value and remote zero-adjustment value are displayed.
For details, refer to “ 11 AUTO-REFERENCE FUNCTION” and “ 12 REMOTE ZERO-ADJUSTMENT FUNCTION.”
3) In the dash line box is not displayed when not setting “ ” or “ ” in external input switch. For the setting
method, refer to <Analogue voltage / current output / external input selection> in “ 8 MENU SETTING MODE.”
Zero-adjustment function
The zero-adjustment function forcibly sets the pressure value to “zero” when the
pressure port is opened.
AutomaticHold down
Key lock function
The key lock function prevents key operations so that the conditions set in each set-
ting mode are not inadvertently changed.
<Key lock set>
AutomaticHold down
<Key lock released>
AutomaticHold down
Peak / bottom hold function
The peak / bottom hold functions display the peak value and bottom value of the
fluctuating pressure.
The peak value is displayed on the main display and the bottom value is displayed
on the sub-display.
The higher vacuum side indicates the peak value, while the lower vacuum side indi-
cates the bottom value.
<Peak / bottom hold set>
Hold down Blinks alternately
<Peak / bottom hold released>
Hold down
8 MENU SETTING MODE
The mode will change to RUN mode when the mode selection key is held down
during this setting process. In doing so, changed items before holding down the
mode selection key have been set.
RUN mode
<Comparative output 1 output mode setting>
EASY mode Hysteresis
mode
Press for 2 sec.
Window
comparator
mode
Standard type
<Comparative output 2 output mode setting> (Note 1)
EASY mode Hysteresis
mode
Window
comparator
modeOFF mode
High-function type
<N.O. / N.C. selection>
N.C.N.O.
Standard type
<N.O. / N.C. selection> (Note 1)
Output 1: N.O.
Output 2: N.O.
Output 1: N.C.
Output 2: N.C. Output 1: N.O.
Output 2: N.C. Output 1: N.C.
Output 2: N.O.
<Response time setting>
5ms2.5ms 5,000ms
<Display color of the main display selection>
Red when ON
Green when OFF Green when ON
Red when OFF Always red Always green
<Unit selection> (Note 2)
kPaMPa bar
inchHg (Note 3)
kgf/cm
2 psi
mmHg (Note 3)
RUN mode
High-function type
<Analogue voltage / current output / external input selection>
Auto-refer-
ence input
Remote
zero-adjust-
ment input
Analogue
voltage output Analogue
current output
Notes: 1) If the comparative output 2 output mode setting is set to “ ”, the display of N.O. / N.C. selection is the same
as the high-function type.
2) In case Japanese, only “MPa” or “kPa” can be set. In the case of a low pressure type for inside of Japan, the
unit switch setting item is not displayed.
3) This is not displayed on the high pressure type.
Setting item Factory setting Description
Comparative output 1
output mode setting Sets the output operation of comparative output 1.
Comparative output 2
output mode setting
(Standard type only)
Sets the output operation of comparative output 2.
Analogue voltage /
current output / ex-
ternal input selection
(High-function type only)
Selects analogue voltage / current output, auto-reference input, or remote
zero-adjustment input.
N.O. / N.C. selection
Low pressure type
High pressure type Normal open (N.O.) or normal close (N.C.) can be selected.
Response time setting
Sets the response time.
The response time can be selected from 2.5ms, 5ms, 10ms, 25ms, 50ms,
100ms, 250ms, 500ms, 1,000ms or 5,000ms.
Displayed color of the
main display selection Displayed color of the main indicator can be changed.
Unit selection
Low pressure type
High pressure type Pressure unit can be changed.
9 PRO MODE
The mode will change to RUN mode when the mode selection key is held down
during this setting process. However, changed items before holding down the mode
selection key have been set.
RUN mode
<PRO mode>
Press for
4 seconds
<Sub-display selection>
Display OFF Unit display No. displayStandard
<Display speed selection>
500ms250ms
<Hysteresis fixed value selection> (1 level: Approx. 1 digit) (When Pa unit is selected.)
<Reset setting>
RUN mode
RUN mode
<Sub-display selection>
When “ ” is set
When “ ” is set
Change the displayed details with
Set pressure
range is displayed
on sub display.
Custom
display
1,000ms
Min.Max.
<Displayed color relation selection>
Relating with
comparative
output 1
Relating with
comparative
output 2
<Eco mode setting>
OFF Standard Max.
Automatic
<Setting check code>
<Setting copy mode>
Copy sending
OFF Copy sending
ON Copy sending
ON-L
Copy ready
state
When “No. display” or “Custom display” is set in “Sub display selection.”
Standard type only
Setting item Factory setting Description
Sub-display selection
Changes the indication of the sub-display.
: Displays nothing.
: Presently selected pressure unit is displayed.
: Desired No. can be shown.
: Desired numbers, alphabets (some of them cannot be displayed)
and signs can be shown.
Display speed
selection Changes the speed of the displayed pressure value on the main display.
Hysteresis fixed
value selection
Sets hysteresis of the EASY mode and the window comparator mode.
(8 steps)
Displayed color rela-
tion selection
(Standard type only)
The setting contents set at the displayed color setting in Menu setting mode
can be related with either comparative output 1 or comparative output 2.
Eco mode setting
Current consumption can be lowered.
: Normal operation (ECO mode is off.)
: If any key operation is not carried out for approx. 5 sec. in RUN
mode, the display becomes dark.
: If any key operation is not carried out for approx. 5 sec. in RUN
mode, the display is turned off.
Press any key to temporarily show the normal indication.
Setting check code Current setting contents can be checked. For codes. refer to “Code table”.
Setting copy mode
The setting of the master side sensor can be copied to the slave side sensors.
For details, refer to “ 10 SETTING COPY FUNCTION.”
: The setting contents are copied.
: The setting contents are copied, and the slave side sensor goes
into key-lock state.
Reset setting
Returns to default settings (factory settings).
By pressing dowun mode key when “ ” mode, becomes default settings
(factory settings).
Code table
Main display (1st digit form left)
Code
1st digit 2nd digit 3rd digit 4th digit
Standard type High-function type Standard type
Comparative
output 1
output mode
N.O. / N.C.
selection
Comparative
output 2
output mode
N.O. / N.C.
selection
A n a l o g u e
voltage / cur-
rent output /
external input
Threshold
display
Displayed
color of the
main display
Displayed
color relation
EASY
N.O. OFF OFF Analogue
voltage output P-1, Lo-1
Red when ON
Comparative
output 1
N.C.
EASY
N.O. Auto reference Hi-1 Comparative
output 2
Hysteresis
N.O. N.C. Remote zero-
adjustment P-2, Lo-2
Green when ON
Comparative
output 1
N.C.
Hysteresis
N.O. Analogue
current output Hi-2 Comparative
output 2
Window
comparator
N.O. N.C. - ADJ.
Always red
Comparative
output 1
N.C. Window
comparator
N.O. - - Comparative
output 2
- - N.C. - -
Always green
Comparative
output 1
- - - - - - Comparative
output 2
Sub-display (5th digit from left)
Code 5th digit 6th digit 7th digit 8th digit
Response time Unit selection Display speed Eco mode
2.5ms MPa 250ms OFF
5ms kPa 500ms Std
10ms kgf/cm
2 1,000ms Full
25ms bar - -
50ms psi - -
100ms mmHg - -
250ms inchHg - -
500ms - - -
1,000ms - - -
5,000ms - - -
10 SETTING COPY FUNCTION
This can copy the settings of the master side sensor to the slave side sensor.
Be sure to use the setting copy function between the identical models.
This function cannot be used between different models.
Only one sensor can be connected on slave side with a master side sensor for the
setting copy function.
Setting procedure
1. Set the setting copy function of the master side sensor to “Copy sending ON” or
“Copy sending ON-L”, and then press the mode selection key so that the sensor is
in copy ready state. For details, refer to <Setting copy mode> in “ 9 PRO MODE”.
2. Turn OFF the master side sensor.
3. Connect the master side sensor with the slave side sensor as shown below.
(Brown) +V +V (Brown)
(Black) Comparative output 1 Comparative output 1 (Black)
(White) Comparative output 2 (Note 1)
Master side sensor Slave side sensor
Comparative output 2 (Note 1) (White)
(Blue) 0V 0V (Blue)
Power supply
Color code of cable
with connector
Notes: 1) For the high-function type, external input.
4. Turn ON the master side sensor and the slave side sensor at the same time.
(Note 2) (Note 3)
5. Set contents (16-bit coded) are shown in orange on the main display of the master
side sensor and the copying starts.
6. The same code explained above is shown in green on the the main display of the
slave side sensor, and is shown on the sub-display (When copying is com-
plete.)
7. Turn OFF the power of the master side sensor and the slave side sensor and dis-
connect the wire.
* If copying the setting to another sensor repeatedly, follow steps 3 to 7.
Notes: 2) Take care that if the power is not turned on at the same time, the setting contents may not be copied.
3) Note that when the power is on, pulse output is output to comparative output 1.
To cancel the setting copy mode of master side sensor
1. Whilst the slave side sensor is disconnected, turn on the power of the master side
sensor.
2. Press the mode selection key for approx. 2 seconds.
11 AUTO-REFERENCE FUNCTION (ONLY HIGH-FUNCTION TYPE)
The auto-reference function
corrects the set value using the
detected pressure value during
auto-reference input as the refer-
ence pressure.
Using the detected pressure val-
ue at auto-reference input P(a)
as a reference, the set value 1
is automatically corrected to “set
value 1 + P(a)”.
Before
auto-reference
After
auto-reference
ON
OFF
ON
OFF
Atmospheric pressure P(a) Set value 1 Set value 1
Detected pressure value
at auto-reference input
Pressure
Set value 1’ after auto-reference is:
1’ = 1 + P(a)
Settable range and set pressure range after correction
The set pressure range is wider than the rating pressure range so that the auto-
reference function can be handled.
If the corrected set value exceeds the set pressure range when auto-reference input
is carried out, the set value will be automatically corrected to within the set pressure
range. Thus, take care not to exceed the set pressure range.
Operation chart
During normal operation
(each comparative output set to N.O.)
During auto-reference input
(each comparative output set to N.O.)
• Detected pressure at auto-reference input: 10kPa
• Output mode: Hysteresis mode
Output
ON
OFF
Applied pressure (kPa) 0
0
10
10
20
20
30
30
40
40
50
50
60
60Displayed value (kPa)
1 2
10 20Set value (kPa)
Output
ON
OFF
Applied pressure (kPa) 0
0
10
10
20
20
30
30
40
40
50
50
60
60Displayed value (kPa)
P(a) 1
10 20Set value (kPa)
2
30
Note: The set values shift in the same manner during the EASY mode or the window comparator mode.
The detected pressure value at auto-reference input becomes “zero” when the set-
ting of the external input selection function is changed or the power is turned ON
again.
The auto-reference input value can be checked when setting the threshold value in
RUN mode. Refer to the threshold value setting in “ 7 RUN MODE” for details.
12 REMOTE ZERO-ADJUSTMENT FUNCTION (HIGH-FUNCTION TYPE)
The remote zero-adjustment function forcibly sets the pressure value to “zero” when
the external signal is inputted.
The set value is not corrected when remote zero-adjustment is input. Make sure that the
pressure and set value during remote zero-adjustment do not exceed the set pressure
range.
Operation chart
During normal operation
(each comparative output set to N.O.)
During remote zero-adjustment input
(each comparative output set to N.O.)
• Detected pressure at remote zero-adjustment input: 10kPa
Output mode: Hysteresis mode
Output
ON
OFF
Applied pressure (kPa) 0
0
10
10
20
20
30
30
40
40
50
50
60
60Displayed value (kPa)
1 2
10 20Set value (kPa)
Output
ON
OFF
Applied pressure (kPa) 0
0
10
10
20
20
30
30
40
40
50
50
60
-10Displayed value (kPa)
1
10 20Set value (kPa)
2
Note: The setting values shift in the same manner during the EASY mode or the window comparator mode.
The remote zero-adjustment value is cleared when the setting of the external input
selection is changed or the power is turned ON again, and normal operation based
on the atmospheric pressure is resumed.
The remote zero-adjustment value can be confirmed when setting the threshold
value in RUN mode. Refer to the threshold value setting in “ 7 RUN MODE”.
13 ERROR INDICATION
Error message Cause Corrective action
The load is short-circuited causing
an overcurrent to flow. Turn the power OFF and check the load.
Pressure is applied during zero-
point adjustment.
Applied pressure at the pressure port should be brought to
atmospheric pressure and zero-point adjustment should be
done again.
External input is carried out outside
the rated pressure range.
Applied pressure range should be brought within the rated
pressure range.
Communication error
(Disconnection, faulty connection, etc.) Check the wiring when using the copy function.
Communication error
(Incorrect model.)
Make sure that the system is configured of the same models
when using the copy function.
The applied pressure exceeds the
upper limit of the display pressure
range. Applied pressure range should be brought within the rated
pressure range.The applied pressure exceeds the
lower limit of the display pressure
range.
When other error massage is displayed, contact us.
14 SPECIFICATIONS
Model
GS6 1 0 2 - 3
1 : 1: Low-pressure type, 2: High-pressure type
2 : None: Standard type, A: High-function type
3 : None: NPN output, R 1 /8 + M5 female screw, For inside of Japan
1W or 2W: NPN output, R1 /8 + M5 female screw, For outside of Japan
F11: NPN output, NPT1 /8 male screw+ M5 female screw, For outside of Japan
F11P: PNP output, NPT1 /8 male screw+ M5 female screw, For outside of Japan
Type
Item
Standard type High-function type
Low-pressure type High-pressure type Low-pressure type High-pressure type
Pressure type Gauge pressure
Rated pressure range -100 to +100kPa -0.1 to +1.0MPa -100 to +100kPa -0.1 to +1.0MPa
Set pressure range -101.0 to +101.0kPa -0.101 to +1.010MPa -101.0 to +101.0kPa -0.101 to +1.010MPa
Withstand pressure 500kPa 1.5MPa 500kPa 1.5MPa
Applicable fluid Non-corrosive gas
Supply voltage 12 to 24V DC ±10%
Power consumption (Note 1)
Normal operation: 720mW or less (current consumption 30mA or less at 24V supply voltage)
ECO mode (STD): 480mW or less (current consumption 20mA or less at 24V supply voltage)
ECO mode (FULL): 360mW or less (current consumption 15mA or less at 24V supply voltage)
Comparative output
<NPN output type>
NPN open-collector transistor
Maximum sink current: 100mA
Applied voltage: 30V DC or less
(between comparative output and 0V)
Residual voltage: 2V or less
(at 100mA sink current )
<PNP output type>
PNP open-collector transistor
Maximum source current: 100mA
Applied voltage: 30V DC or less
(between comparative output and +V)
Residual voltage: 2V or less
(at 100mA source current )
Output operation Selectable either N.O. or N.C., with key operation
Hysteresis Min. 1 digit (variable) (however, 2 digits when using psi units)
Repeatability ±0.1% F.S.
± within 2 digits
±0.2% F.S.
± within 2 digits
±0.1% F.S.
± within 2 digits
±0.2% F.S.
± within 2 digits
Response time 2.5ms, 5ms, 10ms, 25ms, 50ms, 100ms, 250ms, 500ms, 1.000ms or 5,000ms
selectable with key operations
Analogue voltage output
<High-function, low-pressure type>
Output voltage: 1 to 5V
Zero point: Within 3V ± 5% F.S.
Span: Within 4V ± 5% F.S.
Linearity: Within ± 1% F.S.
Output impedance: Approx. 1kΩ
<High-function, high-pressure type>
Output voltage: 0.6 to 5V
Zero point: Within 1V ± 5% F.S.
Span: Within 4.4V ± 5% F.S.
Linearity: Within ± 1% F.S.
Output impedance: Approx. 1kΩ
Analogue current output
<High-function, low-pressure type>
Output current: 4 to 20mA
Zero point: Within 12mA ± 5% F.S.
Span: Within 16mA ± 5% F.S.
Linearity: Within ± 1% F.S.
Load resistance: 250Ω (max.)
<High-function, high-pressure type>
Output current: 2.4 to 20mA
Zero point: Within 4mA ± 5% F.S.
Span: Within 17.6mA ± 5% F.S.
Linearity: Within ± 1% F.S.
Load resistance: 250Ω (max.)
External input
<High-function NPN output type>
ON voltage: 0.4V DC or less
OFF voltage: 5 to 30V DC or open
Input impedance: Approx. 10kΩ
Input time: 1ms or more
<High-function PNP output type>
ON voltage: 5V to +V DC
OFF voltage: 0.6V DC or less or open
Input impedance: Approx. 10kΩ
Input time: 1ms or more
Ambient temperature -10 to +50°C (No dew condensation or icing allowed), Storage: -10 to +60°C
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Temperature characteristics Within ±0.5% F.S.
(at +20°C reference)
Within ±1% F.S.
(at +20°C reference)
Within ±0.5% F.S.
(at +20°C reference)
Within ±1% F.S.
(at +20°C reference)
Material
Enclosure: PBT (with glass fiber), LCD display: Acrylic
Pressure port: Stainless steel (SUS 303)
Mounting screw section: Brass (nickel-plated), O-ring: H-NBR, Key part: Silicon rubber
Weight Approx. 40g (Main body only)
Accessories Cable with a connector (cable length 2m): 1 pc., Unit switching label: 1 pc. (for outside of Japan only)
Note: Current consumption does not include the analog current output.
15 CAUTIONS
This product has been developed / produced for industrial use only.
Use within the rated pressure range.
Do not apply pressure exceeding the pressure withstandability value. The dia-
phragm will get damaged and correct operation shall not be maintained.
Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter motor, etc.) is
used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
Do not use during the initial transient time (0.5 sec.) after the power supply is
switched on.
Extension up to total 100m or less, is possible with more than 0.3mm 2 of electric
conductor cross-sectional area cable.
In case of using this product as a CE Marking conformity product, the wire con-
nected to this product must be within 30m.
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
● The specification may not be satisfied in a strong magnetic field.
Avoid dust, dirt, and steam.
Take care that the sensor does not come in direct contact with water, oil, grease, or
organic solvents, such as, thinner, etc.
Do not insert wires, etc, into the pressure port. The diaphragm will get damaged
and correct operation shall not be maintained.
Do not operate the keys with pointed or sharp objects.
Make sure that stress by forcible bend or pulling is not applied directly to the sensor
cable joint.
16 INTENDED PRODUCTS FOR CE MARKING
The models listed under “ 14 SPECIFICATIONS” come with CE Marking.
As for all other models, please contact our office.
OVERSEAS DEPARTMENT
3-11-28, Midori-cho, Koganei City, Tokyo 184-8533, Japan
Tel: 042-383-7271 Fax: 042-383-7276
PRINTED IN JAPAN
  • Page 1
  • Page 2
  • Page 3
  • Page 4
/

advertisement

Key Features

  • Digital pressure switch
  • User-friendly interface
  • Accurate pressure setting
  • Multiple output modes
  • Auto-reference function
  • Remote zero-adjustment
  • Peak/bottom hold
  • Industrial applications

Related manuals

Frequently Answers and Questions

What are the different types of pressure units supported by the Koganei GS6 Series?
The Koganei GS6 Series supports various pressure units including MPa, kPa, bar, psi, inchHg, and mmHg. The specific units available for the device may vary depending on the model.
How do I change the pressure unit displayed on the Koganei GS6 Series?
You can change the pressure unit by accessing the "Unit Selection" setting within the device. Refer to the "7 RUN MODE" section in the instruction manual for detailed instructions.
How do I set the output mode for the comparative outputs on the Koganei GS6 Series?
The Koganei GS6 Series offers three output modes for comparative outputs 1 and 2: EASY mode, Hysteresis mode, and Window Comparator mode. To select the desired mode, navigate to the "Comparative output 1/2 output mode setting" in the "8 MENU SETTING MODE" section of the instruction manual.

advertisement