KTR Damping rods Operating/Mounting Instructions
KTR Damping rods are designed to reduce noise levels and vibrations in various machinery applications. They are available in different sizes and configurations to accommodate specific needs. These rods are typically used with electric motors, foot flanges, and oil coolers to dampen vibrations and noise generated during operation. They are also equipped with protective features to ensure safe operation and prevent accidents.
advertisement
Damping rods
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42110 EN
1 of 8
2
Please observe protection
note ISO 16016.
Drawn: 2021-02-24 Pz/Str Replacing: KTR-N dated 2021-02-16
Verified: 2021-02-24 Pz Replaced by:
Damping rods reduce the noise level and dampen vibrations.
1 Technical data 2
2 Advice 4
2.1 General advice 4
2.2 Safety and advice symbols 4
2.3 General hazard warnings 4
2.4 Intended use 4
3 Storage, transport and packaging 5
3.1 Storage 5
3.2 Transport and packaging 5
4 Assembly 5
4.1 Load of damping rods 5
4.2 Assembly of damping rods DSM with electric motor 6
4.3 Assembly of damping rods DSFL with foot flange PTFL 6
4.4 Assembly of damping rods DSFS with foot flange PTFS 7
4.5 Assembly of damping rods DSK with PIK oil cooler 7
4.6 Other information 8
5 Disposal 8
6 Spares inventory, customer service addresses 8
Table of contents
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42110 EN
1 of 8
2
Please observe protection
note ISO 16016.
Drawn: 2021-02-24 Pz/Str Replacing: KTR-N dated 2021-02-16
Verified: 2021-02-24 Pz Replaced by:
Damping rods reduce the noise level and dampen vibrations.
1 Technical data 2
2 Advice 4
2.1 General advice 4
2.2 Safety and advice symbols 4
2.3 General hazard warnings 4
2.4 Intended use 4
3 Storage, transport and packaging 5
3.1 Storage 5
3.2 Transport and packaging 5
4 Assembly 5
4.1 Load of damping rods 5
4.2 Assembly of damping rods DSM with electric motor 6
4.3 Assembly of damping rods DSFL with foot flange PTFL 6
4.4 Assembly of damping rods DSFS with foot flange PTFS 7
4.5 Assembly of damping rods DSK with PIK oil cooler 7
4.6 Other information 8
5 Disposal 8
6 Spares inventory, customer service addresses 8
Table of contents
Damping rods
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42110 EN
2 of 8
2
Please observe protection
note ISO 16016.
Drawn: 2021-02-24 Pz/Str Replacing: KTR-N dated 2021-02-16
Verified: 2021-02-24 Pz Replaced by:
Illustration 1: Dimensions of damping rods
Table 1: Type DSM for electric motors type IMB 35, protection class IP54
Size For motor
size
Dimensions [mm]
L L1 L2 L3 h h1 h2 b b1 b2 d D M1 M2
DSM 71 71 196 156 90 - 40 8 12 50 21 25 14 20 M6 -
DSM 80 80 176 146 100 - 40 8 12 50 22 25 14 20 M8 -
DSM 90 S 90 S 196 156 100 - 40 8 12 50 24.5 25 14 20 M8 -
DSM 90 L 90 L 240 205 125 - 40 8 12 50 24 25 14 20 M8 -
DSM 100 L
DSM 112 M
100 L
112 M 240 205 140 - 40 8 12 50 22 25 14 20 M10 -
DSM 132 S
DSM 132 M
132 S
132 M 280 245 140 178 45 8 12 50 20 25 14 20 M10 M10
DSM 160 M 160 M 340 300 210 - 60 15 15 70 28 35 18 26 M12 -
DSM 160 L 160 L 416 370 254 - 60 15 15 70 28 35 18 26 M12 -
DSM 180 M 180 M 416 370 241 - 60 15 15 70 35 35 18 26 M12 -
DSM 180 L 180 L 446 400 279 - 60 15 15 70 35 35 18 26 M12 -
DSM 200 L 200 L 492 430 305 - 60 15 15 70 35 35 22 33 M16 -
DSM 225 S 225 S 492 430 286 - 60 15 15 70 35 35 22 33 M16 -
DSM 225 M 225 M 492 445 311 - 60 15 15 70 35 35 22 33 M16 -
DSM 250 M 250 M 492 445 349 - 60 15 15 100 50 50 22 33 M20 -
DSM 280 S
DSM 280 M
280 S
280 M 614 570 368 419 60 15 15 100 50 50 22 33 M20 M20
DSM 315 S
DSM 315 M
315 S
315 M 614 570 406 457 60 15 15 120 60 60 22 33 M24 M24
DSM 315 L 315 L 704 660 508 - 60 15 15 120 60 60 22 33 M24 -
1 Technical data
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42110 EN
2 of 8
2
Please observe protection
note ISO 16016.
Drawn: 2021-02-24 Pz/Str Replacing: KTR-N dated 2021-02-16
Verified: 2021-02-24 Pz Replaced by:
Illustration 1: Dimensions of damping rods
Table 1: Type DSM for electric motors type IMB 35, protection class IP54
Size For motor
size
Dimensions [mm]
L L1 L2 L3 h h1 h2 b b1 b2 d D M1 M2
DSM 71 71 196 156 90 - 40 8 12 50 21 25 14 20 M6 -
DSM 80 80 176 146 100 - 40 8 12 50 22 25 14 20 M8 -
DSM 90 S 90 S 196 156 100 - 40 8 12 50 24.5 25 14 20 M8 -
DSM 90 L 90 L 240 205 125 - 40 8 12 50 24 25 14 20 M8 -
DSM 100 L
DSM 112 M
100 L
112 M 240 205 140 - 40 8 12 50 22 25 14 20 M10 -
DSM 132 S
DSM 132 M
132 S
132 M 280 245 140 178 45 8 12 50 20 25 14 20 M10 M10
DSM 160 M 160 M 340 300 210 - 60 15 15 70 28 35 18 26 M12 -
DSM 160 L 160 L 416 370 254 - 60 15 15 70 28 35 18 26 M12 -
DSM 180 M 180 M 416 370 241 - 60 15 15 70 35 35 18 26 M12 -
DSM 180 L 180 L 446 400 279 - 60 15 15 70 35 35 18 26 M12 -
DSM 200 L 200 L 492 430 305 - 60 15 15 70 35 35 22 33 M16 -
DSM 225 S 225 S 492 430 286 - 60 15 15 70 35 35 22 33 M16 -
DSM 225 M 225 M 492 445 311 - 60 15 15 70 35 35 22 33 M16 -
DSM 250 M 250 M 492 445 349 - 60 15 15 100 50 50 22 33 M20 -
DSM 280 S
DSM 280 M
280 S
280 M 614 570 368 419 60 15 15 100 50 50 22 33 M20 M20
DSM 315 S
DSM 315 M
315 S
315 M 614 570 406 457 60 15 15 120 60 60 22 33 M24 M24
DSM 315 L 315 L 704 660 508 - 60 15 15 120 60 60 22 33 M24 -
1 Technical data
Damping rods
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42110 EN
3 of 8
2
Please observe protection
note ISO 16016.
Drawn: 2021-02-24 Pz/Str Replacing: KTR-N dated 2021-02-16
Verified: 2021-02-24 Pz Replaced by:
Illustration 1: Dimensions of damping rods
Table 2: Type DSFL for foot flange type PTFL
Size For foot
flange
Dimensions [mm]
L L1 L2 L3 h h1 h2 b b1 b2 d D M1 M2
DSFL 160 PTFL 160 176 130 50 - 40 8 12 50 10 25 14 20 M8 -
DSFL 200 PTFL 200 176 130 60 - 40 8 12 50 15 25 14 20 M10 -
DSFL 250 PTFL 250 230 140 60 - 40 8 12 50 15 25 14 20 M12 -
DSFL 300 PTFL 300 270 170 80 - 40 8 12 50 15 25 14 20 M12 -
DSFL 350 PTFL 350 305 200 110 - 60 15 15 70 25 35 18 26 M16 -
Table 3: Type DSFS for foot flange type PTFS
Size For foot
flange
Dimensions [mm]
L L1 L2 L3 h h1 h2 b b1 b2 d D M1 M2
DSFS 200 PTFS 200 245 205 150 - 40 8 12 50 19 25 13 20 M10 -
DSFS 250 PTFS 250 240 140 185 - 40 8 12 50 17.5 25 13 20 M12 -
DSFS
250/300L
PTFS
250/300L 340 300 185 225 40 8 12 50 17.5 32.5 13 20 M12 M12
DSFS 300 PTFS 300 280 180 225 - 40 8 12 50 17.5 25 13 20 M12 -
DSFS 350 PTFS 350 325 200 265 - 60 15 15 70 25 35 17 26 M16 -
DSFS
350/400 L
PTFS
350/400 L 430 390 265 300 60 15 15 70 25 45 18 26 M16 M16
DSFS 400 PTFS 400 350 234 300 - 60 15 15 70 25 35 17 26 M16 -
DSFS 450 PTFS 450 385 270 335 - 60 15 15 70 25 35 17 26 M16 -
DSFS
450 L
PTFS
450 L 465 425 335 - 60 15 15 70 25 35 18 26 M16 -
DSFS 550 PTFS 550 490 350 415 - 60 15 15 100 25 50 18 26 M16 -
DSFS 660 PTFS 660 635 415 495 - 60 15 15 100 30 50 22 33 M20 -
Table 4: Type DKS for PIK oil cooler
Size For foot
flange
Dimensions [mm]
L L1 L2 L3 h h1 h2 b b1 b2 d D M1 M2
DSK 200 PIK 200 240 210 154.5 - 40 8 12 50 25 25 14 20 M12 -
DSK 250 PIK 250 270 240 175.5 - 40 8 12 50 25 25 14 20 M12 -
DSK 300 PIK 300 280 250 199.5 - 45 8 12 50 25 25 14 20 M12 -
DSK 350 PIK 350 325 295 243.5 - 60 15 15 70 35 35 14 20 M12 -
Please order our special data sheet for special damping rods type SDS.
1 Technical data
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42110 EN
3 of 8
2
Please observe protection
note ISO 16016.
Drawn: 2021-02-24 Pz/Str Replacing: KTR-N dated 2021-02-16
Verified: 2021-02-24 Pz Replaced by:
Illustration 1: Dimensions of damping rods
Table 2: Type DSFL for foot flange type PTFL
Size For foot
flange
Dimensions [mm]
L L1 L2 L3 h h1 h2 b b1 b2 d D M1 M2
DSFL 160 PTFL 160 176 130 50 - 40 8 12 50 10 25 14 20 M8 -
DSFL 200 PTFL 200 176 130 60 - 40 8 12 50 15 25 14 20 M10 -
DSFL 250 PTFL 250 230 140 60 - 40 8 12 50 15 25 14 20 M12 -
DSFL 300 PTFL 300 270 170 80 - 40 8 12 50 15 25 14 20 M12 -
DSFL 350 PTFL 350 305 200 110 - 60 15 15 70 25 35 18 26 M16 -
Table 3: Type DSFS for foot flange type PTFS
Size For foot
flange
Dimensions [mm]
L L1 L2 L3 h h1 h2 b b1 b2 d D M1 M2
DSFS 200 PTFS 200 245 205 150 - 40 8 12 50 19 25 13 20 M10 -
DSFS 250 PTFS 250 240 140 185 - 40 8 12 50 17.5 25 13 20 M12 -
DSFS
250/300L
PTFS
250/300L 340 300 185 225 40 8 12 50 17.5 32.5 13 20 M12 M12
DSFS 300 PTFS 300 280 180 225 - 40 8 12 50 17.5 25 13 20 M12 -
DSFS 350 PTFS 350 325 200 265 - 60 15 15 70 25 35 17 26 M16 -
DSFS
350/400 L
PTFS
350/400 L 430 390 265 300 60 15 15 70 25 45 18 26 M16 M16
DSFS 400 PTFS 400 350 234 300 - 60 15 15 70 25 35 17 26 M16 -
DSFS 450 PTFS 450 385 270 335 - 60 15 15 70 25 35 17 26 M16 -
DSFS
450 L
PTFS
450 L 465 425 335 - 60 15 15 70 25 35 18 26 M16 -
DSFS 550 PTFS 550 490 350 415 - 60 15 15 100 25 50 18 26 M16 -
DSFS 660 PTFS 660 635 415 495 - 60 15 15 100 30 50 22 33 M20 -
Table 4: Type DKS for PIK oil cooler
Size For foot
flange
Dimensions [mm]
L L1 L2 L3 h h1 h2 b b1 b2 d D M1 M2
DSK 200 PIK 200 240 210 154.5 - 40 8 12 50 25 25 14 20 M12 -
DSK 250 PIK 250 270 240 175.5 - 40 8 12 50 25 25 14 20 M12 -
DSK 300 PIK 300 280 250 199.5 - 45 8 12 50 25 25 14 20 M12 -
DSK 350 PIK 350 325 295 243.5 - 60 15 15 70 35 35 14 20 M12 -
Please order our special data sheet for special damping rods type SDS.
1 Technical data
Damping rods
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42110 EN
4 of 8
2
Please observe protection
note ISO 16016.
Drawn: 2021-02-24 Pz/Str Replacing: KTR-N dated 2021-02-16
Verified: 2021-02-24 Pz Replaced by:
Please read carefully through these operating/assembly instructions before you start up the damping rod. Please
pay special attention to the safety instructions!
The operating/assembly instructions are part of your product. Please store them carefully and close to the damp-
ing rods. The copyright for these operating/assembly instructions remains with KTR.STOP
Warning of personal injury
This symbol indicates notes which may contribute to pre-
venting bodily injuries or serious bodily injuries that may
result in death.!
Warning of product damages This symbol indicates notes which may contribute to pre-
venting material or machine damage.
General advice This symbol indicates notes which may contribute to pre-
venting adverse results or conditions.STOP
With assembly and disassembly of the damping rods it has to be made sure that the entire
drive train is secured against accidental switch-on. You may be seriously hurt by rotating
parts. Please make absolutely sure to read through and observe the following safety indica-
tions.
• All operations on and with the damping rods have to be performed taking into account "safety first".
• Please make sure to switch off the power pack before you perform your work on the damping rods.
• Secure the power pack against accidental switch-on, e. g. by providing warning signs at the place of switch-on
or removing the fuse for current supply.
• Do not reach into the operation area of the machine as long as it is in operation.
• Please secure the rotating drive components against accidental contact. Please provide for the necessary
protection devices and covers.
You may only assemble and disassemble the damping rods if you
• have carefully read through the operating/assembly instructions and understood them
• are technically qualified and specifically trained (e. g. safety, environment, logistics)
• are authorized by your company
The damping rod may only be used in accordance with the technical data (see chapter 1). Unauthorized modifica-
tions on the damping rods are not admissible. We will not assume liability for any damage that may arise. In the
interest of further development we reserve the right for technical modifications.
The damping rod described in here corresponds to the technical status at the time of printing of these operat-
ing/assembly instructions.
2 Advice
2.1 General advice
2.2 Safety and advice symbols
2.3 General hazard warnings
2.4 Intended use
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42110 EN
4 of 8
2
Please observe protection
note ISO 16016.
Drawn: 2021-02-24 Pz/Str Replacing: KTR-N dated 2021-02-16
Verified: 2021-02-24 Pz Replaced by:
Please read carefully through these operating/assembly instructions before you start up the damping rod. Please
pay special attention to the safety instructions!
The operating/assembly instructions are part of your product. Please store them carefully and close to the damp-
ing rods. The copyright for these operating/assembly instructions remains with KTR.STOP
Warning of personal injury
This symbol indicates notes which may contribute to pre-
venting bodily injuries or serious bodily injuries that may
result in death.!
Warning of product damages This symbol indicates notes which may contribute to pre-
venting material or machine damage.
General advice This symbol indicates notes which may contribute to pre-
venting adverse results or conditions.STOP
With assembly and disassembly of the damping rods it has to be made sure that the entire
drive train is secured against accidental switch-on. You may be seriously hurt by rotating
parts. Please make absolutely sure to read through and observe the following safety indica-
tions.
• All operations on and with the damping rods have to be performed taking into account "safety first".
• Please make sure to switch off the power pack before you perform your work on the damping rods.
• Secure the power pack against accidental switch-on, e. g. by providing warning signs at the place of switch-on
or removing the fuse for current supply.
• Do not reach into the operation area of the machine as long as it is in operation.
• Please secure the rotating drive components against accidental contact. Please provide for the necessary
protection devices and covers.
You may only assemble and disassemble the damping rods if you
• have carefully read through the operating/assembly instructions and understood them
• are technically qualified and specifically trained (e. g. safety, environment, logistics)
• are authorized by your company
The damping rod may only be used in accordance with the technical data (see chapter 1). Unauthorized modifica-
tions on the damping rods are not admissible. We will not assume liability for any damage that may arise. In the
interest of further development we reserve the right for technical modifications.
The damping rod described in here corresponds to the technical status at the time of printing of these operat-
ing/assembly instructions.
2 Advice
2.1 General advice
2.2 Safety and advice symbols
2.3 General hazard warnings
2.4 Intended use
5
6
7
8
advertisement
Key Features
- Noise reduction
- Vibration damping
- Different sizes
- Electric motor compatibility
- Foot flange compatibility
- Oil cooler compatibility
- Safe operation
Related manuals
Frequently Answers and Questions
What is the purpose of KTR Damping rods?
KTR Damping rods are designed to reduce noise levels and dampen vibrations produced by machinery during operation.
What types of damping rods are available?
The manual describes 4 types of damping rods: DSM, DSFL, DSFS, and DSK. They are compatible with different components like electric motors, foot flanges, and oil coolers.
How do I install KTR Damping rods with an electric motor?
The damping rods are installed by fitting the electric motor's feet onto them. The screws used must be the appropriate length and tightened to the specified torque.
advertisement