XPR BIOPAD-M Owner's Manual
xpr BIOPAD-M is a biometric keypad reader that combines fingerprint and PIN authentication for access control. It boasts a large fingerprint capacity of up to 9500 fingerprints, a programmable Wiegand output for customization and compatibility, and a tamper switch for enhanced security. This device can be used for multiple applications, such as door access in offices, homes, or other secure areas. The BIOPAD-M is designed to be reliable, easy-to-use, and can be integrated with various third-party access control systems.
advertisement
www.xprgroup.com1
BIOPAD-M V1 Biometric keypad reader
EN
INSTALLER MANUAL
v.c1
BIOPAD-M V1 Biometric keypad reader
EN
INSTALLER MANUAL
v.c1
www.xprgroup.com2
1. DESCRIPTION
2. SPECIFICATIONS
3. MOUNTING
4. WIRING
5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER
5.1 CONNECTING BIOMETRIC READERS IN SAME RS-485 LINE WITH THE EWS CONTROLLERS
5.2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP/IP COMMUNICATION
5.3 RS-485 TUNNING
6. CONNECTING BIOMETRIC READERS TO 3RD PARTY CONTROLLER
6.1 CONVERTERS PIN DESCRIPTION
7. ENROLLMENT
8. CONFIGURING THE BIOMETRIC READERS IN PROS SOFTWARE
8.1 ADDING BIOMETRIC READER
8.2 ENROLLING FINGERPRINTS FROM A READER
8.3 ENROLLING FINGERPRINTS FROM DESKTOP READER
8.4 DELETING FINGERPRINTS
8.5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
8.6 FIRMWARE UPDATE
8.7 ENTRY MODE
8.7.1 FINGER OR PIN CODE
8.7.2 FINGER AND PIN CODE
8.7.3 FINGER ONLY
8.8 CHANGE PIN CODE LENGTH
8.9 SENSOR CALIBRATION
8.10 SEND CONFIGURATION
8.11 ADVANCED SETTING
9. CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER
9.1 ADD PORTAL
9.2 ADD READER
9.3 EDIT READER
9.4 DELETE READER
9.5 ADD USER
9.6 DELETE FINGERPRINTS
9.7 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
9.8 CUSTOM WIEGAND
10. WIEGAND PROTOCOL DESCRIPTION
11. SAFETY PRECAUTIONS
Contents
3
3
4
4
5
5
6
6
7
7
7
8
8
9
10
11
11
12
12
12
12
13
13
13
13
14
14
14
15
15
16
17
17
18
19
20
21
1. DESCRIPTION
2. SPECIFICATIONS
3. MOUNTING
4. WIRING
5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER
5.1 CONNECTING BIOMETRIC READERS IN SAME RS-485 LINE WITH THE EWS CONTROLLERS
5.2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP/IP COMMUNICATION
5.3 RS-485 TUNNING
6. CONNECTING BIOMETRIC READERS TO 3RD PARTY CONTROLLER
6.1 CONVERTERS PIN DESCRIPTION
7. ENROLLMENT
8. CONFIGURING THE BIOMETRIC READERS IN PROS SOFTWARE
8.1 ADDING BIOMETRIC READER
8.2 ENROLLING FINGERPRINTS FROM A READER
8.3 ENROLLING FINGERPRINTS FROM DESKTOP READER
8.4 DELETING FINGERPRINTS
8.5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
8.6 FIRMWARE UPDATE
8.7 ENTRY MODE
8.7.1 FINGER OR PIN CODE
8.7.2 FINGER AND PIN CODE
8.7.3 FINGER ONLY
8.8 CHANGE PIN CODE LENGTH
8.9 SENSOR CALIBRATION
8.10 SEND CONFIGURATION
8.11 ADVANCED SETTING
9. CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER
9.1 ADD PORTAL
9.2 ADD READER
9.3 EDIT READER
9.4 DELETE READER
9.5 ADD USER
9.6 DELETE FINGERPRINTS
9.7 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
9.8 CUSTOM WIEGAND
10. WIEGAND PROTOCOL DESCRIPTION
11. SAFETY PRECAUTIONS
Contents
3
3
4
4
5
5
6
6
7
7
7
8
8
9
10
11
11
12
12
12
12
13
13
13
13
14
14
14
15
15
16
17
17
18
19
20
21
www.xprgroup.com3
Fingerprint capacity up to 9500 fingerprints
Technology Biometry and Keypad
Authentication Finger, PIN Code, Finger or/and PIN Code
Fingerprints per user 1-10 fingerprints
PIN Code Length 1- 8 Digits
Interface Wiegand 8 to 128 bits; Default: Wiegand 26bit
Protocol programming By PROS software (EWS system) and BIOMANAGER (all access control systems)
Cable distance 150m
Fingerprint Sensor Type Capacitive
1:1000 identification time 970 msec, including feature extraction time
Fingerprint enrolment On the reader or from the USB desktop reader
Panel Connection Cable, 0.5m
Green and Red LED Externally Controlled
Orange LED Idle mode
Buzzer Yes
Backlight ON/OFF Yes, by software settings
Tamper Yes
Consumption Max. 150mA
IP Rating 65
Power supply 9-14V DC
Operating Temperature -15°C to +50°C, non-condensing
Dimensions (mm) 100 x 94 x 30
Housing Moulded Aluminium
BIOPAD-M V1 is a Wiegand biometric keypad for access control applications with backlit keys and programmable wiegand output.
It offers storage up to 9500 fingerprints, programmable Wiegand Output (8 to 128 bits) and selectable PIN Code length.
The tamper switch output can trigger the alarm system, if an attempt is made to open or remove the unit from the wall.
The tamper switch output can trigger the alarm system, if an attempt is made to open or remove the unit from the wall.
Configuration of the readers and fingerprint enrollment is done through PC Software.
Connection between the biometric readers is RS-485 and it is used for fingerprint transfer and configuration. When used with
third party controllers, the connection between the Biometric readers and the PC is done through a converter (CNV200-RS-485
to USB or CNV1000-RS-485 to TCP/IP). Only one converter is needed per system (one converter for 1, 2, 3...30, 31 Biometric
readers).
1. DESCRIPTION
2. SPECIFICATIONS
Fingerprint capacity up to 9500 fingerprints
Technology Biometry and Keypad
Authentication Finger, PIN Code, Finger or/and PIN Code
Fingerprints per user 1-10 fingerprints
PIN Code Length 1- 8 Digits
Interface Wiegand 8 to 128 bits; Default: Wiegand 26bit
Protocol programming By PROS software (EWS system) and BIOMANAGER (all access control systems)
Cable distance 150m
Fingerprint Sensor Type Capacitive
1:1000 identification time 970 msec, including feature extraction time
Fingerprint enrolment On the reader or from the USB desktop reader
Panel Connection Cable, 0.5m
Green and Red LED Externally Controlled
Orange LED Idle mode
Buzzer Yes
Backlight ON/OFF Yes, by software settings
Tamper Yes
Consumption Max. 150mA
IP Rating 65
Power supply 9-14V DC
Operating Temperature -15°C to +50°C, non-condensing
Dimensions (mm) 100 x 94 x 30
Housing Moulded Aluminium
BIOPAD-M V1 is a Wiegand biometric keypad for access control applications with backlit keys and programmable wiegand output.
It offers storage up to 9500 fingerprints, programmable Wiegand Output (8 to 128 bits) and selectable PIN Code length.
The tamper switch output can trigger the alarm system, if an attempt is made to open or remove the unit from the wall.
The tamper switch output can trigger the alarm system, if an attempt is made to open or remove the unit from the wall.
Configuration of the readers and fingerprint enrollment is done through PC Software.
Connection between the biometric readers is RS-485 and it is used for fingerprint transfer and configuration. When used with
third party controllers, the connection between the Biometric readers and the PC is done through a converter (CNV200-RS-485
to USB or CNV1000-RS-485 to TCP/IP). Only one converter is needed per system (one converter for 1, 2, 3...30, 31 Biometric
readers).
1. DESCRIPTION
2. SPECIFICATIONS
www.xprgroup.com4
3. MOUNTING
4. WIRING
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the MCD-MINI polycarbonate cover available
in our accessories in order to protect the sensor from direct rainfall. The operating temperature of the product is between -15ºC - +
50ºC. If the reader is installed in an environment where the temperature can drop below -10ºC or/and if the sensor could only be
exposed to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box (fitted with
additional heater if very low temperature) to keep a constant sensor level performance. XPRâ„¢ cannot guarantee the functionality
of the product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also
the possibility to use different readers depending on users.
4 (3 x 30mm)
1 (M3 x 6mm)
Red
Black
Pink
Violet
Orange
Green
White
Yellow
Gray
Blue
RS-485
LED Red-
LED Green-
WIEGAND
12V DC
GND
A
B
LR-
LG-
D1
D0
Tamper
Tamper
9-14V DC
ground
RS-485 A
RS-485 B
Red LED -
Green LED -
Data 1
Data 0
Tamper Switch(NO)
Tamper Switch(NO)
Tricolor LED (Red, Green, Orange)
3. MOUNTING
4. WIRING
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the MCD-MINI polycarbonate cover available
in our accessories in order to protect the sensor from direct rainfall. The operating temperature of the product is between -15ºC - +
50ºC. If the reader is installed in an environment where the temperature can drop below -10ºC or/and if the sensor could only be
exposed to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box (fitted with
additional heater if very low temperature) to keep a constant sensor level performance. XPRâ„¢ cannot guarantee the functionality
of the product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also
the possibility to use different readers depending on users.
4 (3 x 30mm)
1 (M3 x 6mm)
Red
Black
Pink
Violet
Orange
Green
White
Yellow
Gray
Blue
RS-485
LED Red-
LED Green-
WIEGAND
12V DC
GND
A
B
LR-
LG-
D1
D0
Tamper
Tamper
9-14V DC
ground
RS-485 A
RS-485 B
Red LED -
Green LED -
Data 1
Data 0
Tamper Switch(NO)
Tamper Switch(NO)
Tricolor LED (Red, Green, Orange)
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
advertisement
Key Features
- Biometric keypad reader
- Fingerprint capacity up to 9500
- Programmable Wiegand output
- Tamper switch
- RS-485 communication
Related manuals
Frequently Answers and Questions
What is the maximum number of fingerprints that BIOPAD-M can store?
The BIOPAD-M can store up to 9500 fingerprints.
How do I connect the BIOPAD-M to a third-party access control system?
You can connect the BIOPAD-M to a third-party access control system using the Wiegand output. The manual provides detailed instructions for connecting to different controllers.
What is the purpose of the tamper switch?
The tamper switch triggers the alarm system if an attempt is made to open or remove the BIOPAD-M from the wall. It provides an extra layer of security.
advertisement