XPR DINBIOC3 Owner's Manual
The xpr DINBIOC3 is a Wiegand biometric reader designed for indoor access control applications. It boasts a capacity of up to 9500 fingerprints and allows for programmable output. The reader can be connected with various devices such as proximity readers and keypads, and it is compatible with third-party controllers. Fingerprint enrollment can be managed through PC software, and the reader can be mounted on a wall using a standard wall mount box.
advertisement
USER’S MANUAL
DINBIOC3 V1 BIOMETRIC READER
1
v.c1
EN
DINBIOC3 V1 BIOMETRIC READER
1
v.c1
EN
Contents
2
1. DESCRIPTION
2. SPECIFICATIONS
3. MOUNTING
4. WIRING
4.1 CONNECTING DINBIOC3 V1 WITH DINMTPX PROXIMITY READER
4.2 CONNECTING DINBIOC3 V1 WITH DINPAD-M KEYPAD
5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER
5.1 CONNECTING BIOMETRIC READERS IN SAME RS485 LINE WITH THE EWS CONTROLLERS
5.2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP/IP COMMUNICATION
5.3 RS485 TUNING
6. CONNECTING BIOMETRIC READERS TO 3RD PARTY CONTROLLER
6.1 CONVERTERS PIN DESCRIPTION
7. ENROLLMENT
8. CONFIGURING THE BIOMETRIC READERS IN PROS SOFTWARE
8.1 ADDING BIOMETRIC READER
8.2 ENROLLING FINGERPRINTS FROM A READER
8.3 ENROLLING FINGERPRINTS FROM DESKTOP READER
8.4 DELETING FINGERPRINTS
8.5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
8.6 FIRMWARE UPDATE
8.7 SEND CONFIGURATION
8.8 ADVANCED SETTINGS
9. CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER
9.1 ADD PORTAL
9.2 ADD READER
9.3 EDIT READER
DELETE READER9.4
9.5 ADD USER
9.6 DELETING FINGERPRINTS
9.7 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
9.8 CUSTOM WIEGAND
10. WIEGAND PROTOCOL DESCRIPTION
11. SAFETY PRECAUTIONS
3
3
3
4
5
5
6
6
7
7
7
7
8
9
10
11
11
12
12
12
13
13
13
14
14
15
16
16
17
18
19
4
4
2
1. DESCRIPTION
2. SPECIFICATIONS
3. MOUNTING
4. WIRING
4.1 CONNECTING DINBIOC3 V1 WITH DINMTPX PROXIMITY READER
4.2 CONNECTING DINBIOC3 V1 WITH DINPAD-M KEYPAD
5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER
5.1 CONNECTING BIOMETRIC READERS IN SAME RS485 LINE WITH THE EWS CONTROLLERS
5.2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP/IP COMMUNICATION
5.3 RS485 TUNING
6. CONNECTING BIOMETRIC READERS TO 3RD PARTY CONTROLLER
6.1 CONVERTERS PIN DESCRIPTION
7. ENROLLMENT
8. CONFIGURING THE BIOMETRIC READERS IN PROS SOFTWARE
8.1 ADDING BIOMETRIC READER
8.2 ENROLLING FINGERPRINTS FROM A READER
8.3 ENROLLING FINGERPRINTS FROM DESKTOP READER
8.4 DELETING FINGERPRINTS
8.5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
8.6 FIRMWARE UPDATE
8.7 SEND CONFIGURATION
8.8 ADVANCED SETTINGS
9. CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER
9.1 ADD PORTAL
9.2 ADD READER
9.3 EDIT READER
DELETE READER9.4
9.5 ADD USER
9.6 DELETING FINGERPRINTS
9.7 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS
9.8 CUSTOM WIEGAND
10. WIEGAND PROTOCOL DESCRIPTION
11. SAFETY PRECAUTIONS
3
3
3
4
5
5
6
6
7
7
7
7
8
9
10
11
11
12
12
12
13
13
13
14
14
15
16
16
17
18
19
4
4
80 mm
9 mm
80 mm
DINBIOC3 V1 is a Wiegand biometric reader for indoors access control applications. It offers storage up to 9500 fingerprints and programmable
Wiegand Output (8 to 128 bits).
Configuration of the readers and fingerprint enrollment is done through PC Software.
Connection between the biometric readers is RS485 and it is used for fingerprint transfer and configuration.
When used with third party controllers, the connection between the Biometric readers and the PC is done through a converter (CNV200-RS485
to USB or CNV1000-RS485 to TCP/IP). Only one converter is needed per system (one converter for 1, 2, 3...30, 31 Biometric readers)
The tamper switch output can trigger the alarm system, if an attempt is made to open or remove the unit from the wall.
1. DESCRIPTION
2. SPECIFICATIONS
Technology
Authentication
Interface
Protocol programming
Fingerprint Sensor Type
1:1000 identification time
Fingerprint enrolment
Panel Connection
Green and Red LED
Orange LED
Buzzer ON/OFF
Consumption
Power supply
IP Rating
Operating Temperature
Dimensions (mm)
Biometry
Finger
Wiegand 8 to 128 bits; Default: Wiegand 26bit
By PROS CS software (EWS system) and BIOMANAGER CS (all access control systems)
Capacitive
970 msec, including feature extraction time
On the reader or from the USB desktop reader
Terminal Blocks
Externally Controlled
Idle mode
Yes
100mA
40
9-14V DC
0°C to +40°C
80 x 80 x 9
Storage/Operating Humidity 5% to 93% RH without condensation
Cable distance 50m
Backlight ON/OFF Yes
Fingerprint capacity up to fingerprints9500
Fingerprints per user 1-10 fingerprints
Tamper Yes
3. MOUNTING
Use Indoors
3
Note: Wall mount box not supplied!
9 mm
80 mm
DINBIOC3 V1 is a Wiegand biometric reader for indoors access control applications. It offers storage up to 9500 fingerprints and programmable
Wiegand Output (8 to 128 bits).
Configuration of the readers and fingerprint enrollment is done through PC Software.
Connection between the biometric readers is RS485 and it is used for fingerprint transfer and configuration.
When used with third party controllers, the connection between the Biometric readers and the PC is done through a converter (CNV200-RS485
to USB or CNV1000-RS485 to TCP/IP). Only one converter is needed per system (one converter for 1, 2, 3...30, 31 Biometric readers)
The tamper switch output can trigger the alarm system, if an attempt is made to open or remove the unit from the wall.
1. DESCRIPTION
2. SPECIFICATIONS
Technology
Authentication
Interface
Protocol programming
Fingerprint Sensor Type
1:1000 identification time
Fingerprint enrolment
Panel Connection
Green and Red LED
Orange LED
Buzzer ON/OFF
Consumption
Power supply
IP Rating
Operating Temperature
Dimensions (mm)
Biometry
Finger
Wiegand 8 to 128 bits; Default: Wiegand 26bit
By PROS CS software (EWS system) and BIOMANAGER CS (all access control systems)
Capacitive
970 msec, including feature extraction time
On the reader or from the USB desktop reader
Terminal Blocks
Externally Controlled
Idle mode
Yes
100mA
40
9-14V DC
0°C to +40°C
80 x 80 x 9
Storage/Operating Humidity 5% to 93% RH without condensation
Cable distance 50m
Backlight ON/OFF Yes
Fingerprint capacity up to fingerprints9500
Fingerprints per user 1-10 fingerprints
Tamper Yes
3. MOUNTING
Use Indoors
3
Note: Wall mount box not supplied!
B
12V DC
LG-
D0
D1
LR -
GND
A TamperRS485
WIEGAND
12V DC
GND
Tamper
Tamper Tamper Switch(NO)
9-14V DC
ground
D1
D0
Data 1
Data 0
LR- Red LED -
LG- Green LED -
A
B
RS485 A
RS485 B
Tamper Switch(NO)
TAMP +12V GND
AB D1LR- LG- D0
Connection to proximity reader DINMTPX
or Keypad DINPAD-M
LEDs
DINMTPX-M
tamp LR- LG- D1 D0 gnd +12V
TAMP +12V GND
AB D1LR- LG- D0
EWSmax. 50mDINMTPXDINBIOC3 V1
B
LG-
D0
D1
LR -
A
+12VDC
GND
fig. 1
fig. 2
fig. 3
EWSmax. 50mDINPAD-MDINBIOC3 V1
B
LG-
D0
D1
LR -
A
+12VDC
GND
Press B+000000
Press 0
Press 2
Press A to exit
TAMP +12V GND
AB D1LR- LG- D0
fig. 1
fig. 2
fig. 3
fig. 4
4. WIRING
4.1 CONNECTING DINBIOC3 V1 WITH DINMTPX PROXIMITY READER
1. Connect both devices with the cable provided. (fig. 1)
2. Connect the DINBIOC3 V1 to the controller. The proximity reader is not connected to the controller. (fig. 2)
3. In the software, in reader’s properties, for type of the reader select DINBIO+DINMTPX. (fig. 3)
4.2 CONNECTING DINBIOC3 V1 WITH DINPAD-M KEYPAD
1. Connect both devices with the cable provided. (fig. 1)
2. Connect the DINBIOC3 V1 to the controller. The Keypad is not connected to the controller. (fig. 2)
3. In the software, in reader’s properties, for type of the reader select DINBIO+DINPAD-M. (fig. 3)
4. Put the Keypad to work as Slave unit. (fig. 4)
4
12V DC
LG-
D0
D1
LR -
GND
A TamperRS485
WIEGAND
12V DC
GND
Tamper
Tamper Tamper Switch(NO)
9-14V DC
ground
D1
D0
Data 1
Data 0
LR- Red LED -
LG- Green LED -
A
B
RS485 A
RS485 B
Tamper Switch(NO)
TAMP +12V GND
AB D1LR- LG- D0
Connection to proximity reader DINMTPX
or Keypad DINPAD-M
LEDs
DINMTPX-M
tamp LR- LG- D1 D0 gnd +12V
TAMP +12V GND
AB D1LR- LG- D0
EWSmax. 50mDINMTPXDINBIOC3 V1
B
LG-
D0
D1
LR -
A
+12VDC
GND
fig. 1
fig. 2
fig. 3
EWSmax. 50mDINPAD-MDINBIOC3 V1
B
LG-
D0
D1
LR -
A
+12VDC
GND
Press B+000000
Press 0
Press 2
Press A to exit
TAMP +12V GND
AB D1LR- LG- D0
fig. 1
fig. 2
fig. 3
fig. 4
4. WIRING
4.1 CONNECTING DINBIOC3 V1 WITH DINMTPX PROXIMITY READER
1. Connect both devices with the cable provided. (fig. 1)
2. Connect the DINBIOC3 V1 to the controller. The proximity reader is not connected to the controller. (fig. 2)
3. In the software, in reader’s properties, for type of the reader select DINBIO+DINMTPX. (fig. 3)
4.2 CONNECTING DINBIOC3 V1 WITH DINPAD-M KEYPAD
1. Connect both devices with the cable provided. (fig. 1)
2. Connect the DINBIOC3 V1 to the controller. The Keypad is not connected to the controller. (fig. 2)
3. In the software, in reader’s properties, for type of the reader select DINBIO+DINPAD-M. (fig. 3)
4. Put the Keypad to work as Slave unit. (fig. 4)
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
advertisement
Key Features
- Fingerprint Capacity: up to 9500 fingerprints
- Wiegand Output: 8 to 128 bits, programmable
- Connection: RS485 for fingerprint transfer and configuration
- Third Party Compatibility
- Wall Mountable
- Tamper Switch Output
- PC Software Configuration
- LED Indicators
- Buzzer
- Backlight
Related manuals
Frequently Answers and Questions
How many fingerprints can the DINBIOC3 store?
The DINBIOC3 can store up to 9500 fingerprints.
What kind of connection does the DINBIOC3 use for communication?
The DINBIOC3 utilizes RS485 for fingerprint transfer and configuration.
Can I connect the DINBIOC3 to third-party controllers?
Yes, the DINBIOC3 is compatible with third-party controllers. You'll need to connect it through a converter, such as the CNV200-RS485 to USB or CNV1000-RS485 to TCP/IP.
How do I enroll fingerprints for the DINBIOC3?
Fingerprint enrollment can be done either on the reader itself or from a USB desktop reader. The process is guided by the PROS CS or BIOMANAGER software.
What is the maximum distance for the RS485 connection?
The maximum distance for the RS485 connection with the DINBIOC3 and EWS controllers is 50 meters per segment. You can use multiple segments with a maximum of 32 units per network, or a RS485 HUB for larger networks.
advertisement