SCT RC7-PD2 Application Guide

SCT RC7-PD2 Application Guide

The SCT RC7-PD2 is a powerful extension kit designed to integrate Poly EagleEye Director II and Group Series 300, 500, 700 & 7500 Codecs, extending their capabilities without compromising quality. It utilizes a SCTLink™ cable for video, control & audio transmission, ensuring seamless integration between components. The RC7-PD2 also includes a dedicated power supply (WPS-48) for reliable operation. The system utilizes a unique combination of HDMI/RJ45 connections to enable communication and data transfer between the EagleEye Director II base and the RC7-CE module, further strengthening its functionality. The versatile RC7-PD2 extension kit opens up new possibilities for your video conferencing solution, offering greater flexibility and scalability in managing your audio visual setup.

advertisement

ModuleDimensions
RC7-CE:1.625H x6.625W x4.625D
RC7-HE:1.625H x8.875W x4.625D
RC7-HE
RC7-CE
PolyRPG300,RPG500,RPG700&RPG7500
PolyDirectorII
W PS-4848VDC
100-240V~47-63Hz
PowerSupply
3rdPartyDevice
RCC-H030-1.0M
HDCItoHDMI/DB9
PolySupplied
AudioCable#2457-69476-001
3.5mm Adapter#1517-09350-001
Pin1
RJ45Pinout
oO gBbG brBR
12345678
T-568B
gG oBbO brBR
12345678
T-568A
SCTLinkCableSpecs
Integrator-SuppliedCAT6STP/UTPCable
EIA568A orEIA568B(10m-100m min/maxLength)
Important: Due to the power
demandsofPolysDirectorII,itis
best practice to utilize SCTs
provided RC-RKM™ rackshelfto
facilitateventilation.
SCTLinkCable
Power,Control,Audio&Video
TheSCTLinkcablemustalwaysbeasingle,point-to-point
CATcablewithnocouplersorinterconnections.
Optional
Optional
Optional3rdParty
AudioInput
PPC-015-0.4M
PowerCable
RCC-C030-0.4M
HDMI/RJ45to
Mini-HDCICable
RCC-C016-0.3M
AudioCable
(Far-endreference
forauto-tracking)
RC7-PD2™ApplicationGuide
RC7-PD2™ Installation Instructions
Supporting the Poly EagleEye Director II

and Group Series 300, 500, 700 & 7500 Codecs

TEST
YOUR SCTLink™ CABLE
We highly recommend using an Ethernet Network Tester/Analyzer alongside our provided PowerSniffer to confirm your

SCTLink™

wiring. Our PowerSniffer only tests conductor continuity and will not identify data integrity or capacity issues.

1.
Test and verify your CAT6 STP or UTP SCTLink™ cable for EIA568A or EIA568B.
The
SCTLink™ cable must be between 10m (minimum) and 100m (maximum) length.
2.
Connect one end of the SCTLink™ cable to the “SCTLink™” connection on the Head End module.
3.
Connect the other end of your SCTLink™ cable to the provided PowerSniffer.
4.
Connect the WPS-48 power supply to the Head End module.
5.
Connect the WPS-48 power supply to AC mains.
6.
If the SCTLink™ cable is properly terminated, it will display eight GREEN LEDs.
If you get any other result,

stop and re-terminate cable
.
7.
Once your SCTLink™ cable has been tested, please disconnect the WPS-48 power supply from the RC7-HE module,
and the PowerSniffer from the
SCTLink™ cable, before proceeding to install.
INSTALL THE EXTENSION KIT

Before integrating your RC7-PD2
extension kit, please ensure your Poly EagleEye Director II base is connected to your two
EagleEyeIV cameras (Power and Ethernet connections) via Poly’s instructions.

Connect the camera-end cables:

1.
Connect the RCC-C030 mini-HDCI end to the mini-HDCI
input on the EagleEye Director II base.

• Connect the RCC-C030 HDMI leg cable to the

RC7-CE’s HDMI “HDMI In” port.

• Connect the RJ45 leg cable to the RC7-CE’s

“Power Serial/IR” port.

2.
Connect the RCC-C016 1’ Audio Cable between the RC7-
CE “Line Out” port and the EagleEye Director II’s audio

TRS input.

3.
Connect the PPC-015 Power Cable between the
EagleEye Director II’s power input and the RC7-CE’s

power input, labeled “+12VDC Output”.

Connect the codec-end cables:

4.
Connect the RCC-H030’s HDCI end to the primary HDCI
input on the Group Series codec.

• Connect the HDMI leg cable to the RC7-HE’s

HDMI “Output 1” port.

• Connect the 9Pin leg cable to the RC7-HE’s

port labeled ‘Serial/IR’.

5.
Connect the Polycom supplied audio cable between the
RC7-HE’s “Line In” port and the Group Series Codec’s

audio inputs.

Connect and Initiate the Extended System:

6.
Connect one end of your CAT6 SCTLink™ cable to the
RC7-HE module’s “
SCTLink™” port. Connect the other
end to the RC7-CE module’s “
SCTLink™” port.
7.
Connect the WPS-48 Power Supply to the RC7-HE.
TECH SUPPORT: 203-854-5701
WWW.SOUNDCONTROL.NET ©SOUND CONTROL TECHNOLOGIES, INC
ALLOW UP TO TWO MINUTES FOR THE EAGLEEYE DIRECTOR II SYSTEM TO INITIALIZE
Power Supply Specifications (AC-Mains Side):
Input Voltage: 100VAC to 240VAC 47Hz to 63Hz. Efficiency: 85% minimum.
Turn-on Surge: Less than 60 amperes for a duration less than 1mS. Power Factor: 0.9 minimum (where applicable). 48VDC

power supply uses 2.80 amperes AC maximum. All specifications subject to change without notice.

Installation Status
- Refer to our modules’ LEDs for installation status.
For assistance troubleshooting INACTIVE LED statuses, please contact Tech Support at 203-854-5701.

MODULE LED LABEL ACTIVE STATUS INACTIVE STATUS

RC7-CE OK LED Blinking Green (~1 second interval) Blinking or Solid Red

RC7-HE OK LED Blinking Green (~1 second interval) Blinking or Solid Red

RC7-HE LINK LED Solid Green Solid Red or Dormant

Cable Table
- Part numbers, descriptions and functions of all provided SCT cables.
This kit includes
[1] RC-RKM™ Rack Shelf.
CABLE DESCRIPTION FUNCTION

RCC-C030-0.4M HDMI/RJ45 to Mini-HDCI Cable Video/control connection between Director II base and RC7-CE Module.

RCC-C016-0.3M Audio Cable Audio connection between Director II base and RC7-CE module.

PPC-015-0.4M Power Cable Supplies power from RC7-CE module to the Director II base.

RCC-H030-1.0M HDMI/ DB9 to HDCI Video/control connection between RPG Series Codec and RC7-HE module.

Updated: 12/16/2020
  • Page 1
  • Page 2
/

advertisement

Key Features

  • SCTLink™ cable
  • HDMI/RJ45 connection
  • Dedicated power supply
  • Integrates Poly EagleEye Director II
  • Supports Group Series codecs
  • Extension kit functionality
  • Supports PowerSniffer testing
  • LED status indication
  • Rack shelf included
  • Technical support available

Related manuals

Frequently Answers and Questions

What is the maximum length of the SCTLink™ cable?
The SCTLink™ cable must be between 10m (minimum) and 100m (maximum) length
How do I test the SCTLink™ cable?
Use an Ethernet Network Tester/Analyzer alongside the provided PowerSniffer to confirm wiring. The PowerSniffer tests conductor continuity
What are the LED statuses on the RC7-CE and RC7-HE modules?
Blinking Green indicates active status. Blinking or Solid Red indicates inactive status.
What does the LINK LED indicate on the RC7-HE module?
Solid Green indicates active connection. Solid Red or Dormant indicates an issue with the connection.
What is the purpose of the RCC-C030-0.4M HDMI/RJ45 to Mini-HDCI Cable?
It provides video and control connections from the Director II base to the RC7-CE module.

advertisement