Spreader Terminals for 140G2-K, 140G2-L, 140MG2-K, 140MG2-L
Terminali prolungati divaricati
Vorderseitige verlängerte V-förmige Anschlüsse
Prises avant prolongées écartées
Terminales frontales prolongados separados
扩展前终端
WARNING: To prevent electrical shock, disconnect from power source before
installing or servicing. Install in suitable enclosure. Keep free from contaminants.
70E requirements
Per prevenire infortuni, togliere tensione prima dell'installazione o
manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
WARNUNG: Vor Installations- oder Servicearbeiten Stromversorgung zur
Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem
passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden.
AVERTISSEMENT: Avant le montage et la mise en service, couper l'alimentation
secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire
appropriée. Protéger le produit contre les environnements agressifs.
ADVERTENCIA: Desconéctese de la corriente eléctrica, antes de la instalación o
del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada.
Manténgalo libre de contaminantes.
ATENÇÃO: Para evitar choques, desconectar da corrente elétrica antes de fazer a
instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de
contaminantes.
警告:感電事故防止のため、取付けまたは修理の際は電源から取り外してく
ださい。適切なケース内に取付けてください。また、汚染物質がないことを
確認してください。
警告 了防止触,在安装或修之前必先切断源。安装在合设备
箱内。防止接触染物。
Installation - Installazione - Installation - Installation -
Instalación - Instalação - -
Bul. 140G2
DIR 1002011A1803 Version 01 - 140G2-K-EXS3, 140G2-K-EXS4
Publication 140G-IN222B-EN-P - April 2022
140G2-K, 140MG2-K
140G2-L, 140MG2-L
xx lb-in
xx Nm
CH 8
Required Tools
TX 25
Clack!1
E
140G2-K-EXS4 3
2140G2-K-EXS3
4p
3p
C D
4 1
3 -
1
1
1
-
-
1
4
3
1
1
HF G JI
M
L
M4
0.394"
(10mm)
Phase
Barriers
140G2-K-PB3L
140G2-K-PB4L
4p-
3p-
Terminals
B
1
-
4p Spreader
Back Shield
A
-
1
3p Spreader
Back Shield
Spreader Terminals for 140G2-K, 140G2-L, 140MG2-K, 140MG2-L2
DIR 1002011A1803 (Version 01)Publication 140G-IN222B-EN-P - April 2022
1
6
3
7
4
2
CH 8
140G2-K-EXS4
TX 25
140G2-K-EXS4
CH 8
140G2-K-EXS3
B
1
1
2 36 Nm
319 lb in
H
F
D
TX 25
140G2-K-EXS3
1
2
I
5
D
E
1
2
H
G
36 Nm
319 lb in
1.2 Nm
10.6 lb in
1.2 Nm
10.6 lb in
8
9
140G2-K-EXS3
140G2-K-EXS4
3Spreader Terminals for 140G2-K, 140G2-L, 140MG2-K, 140MG2-L
DIR 1002011A1803 (Version 01)Publication 140G-IN222B-EN-P - April 2022
DIR 1002011A1803 (Version 01)
Copyright © 2022 Rockwell Automation, Inc. Al l Rights Reserved. Printed in USA.
Publication 140G-IN222B-EN-P - April 2022
Product certificates are located in the Rockwell Automation Literature Library: rok.auto/certifications.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
EEE Yönetmeliğine Uygundur.
For Technical Support, visit rok.auto/support.
AMERICAS
EUROPE/MIDDLE EAST/AFRICA
ASIA PACIFIC
expanding human possibilityTM
(ECN000231036) - ECN000231036
10
4 Spreader Terminals for 140G2-K, 140G2-L, 140MG2-K, 140MG2-L
140G2-K-EXS3, 140G2-K-EXS4: ≥500V AC (≥250V DC) or REVERSE FEED Insulation Requirements
≥500V AC *
(≥250V DC)*
REQUIRED: 140G2-K-TC3S, 140G2-K-TC4S
*Breakers and accessories are tested for conformance
to governing body standards with insulated cable or
busbar. Any other configuration must be tested in the
installation at the cost of the customer
Refer to the IN233 for installation requirements
Ordered separately
PH 1
4.4 lb-in
0.5 Nm
3
B
3