Allen-Bradley 59RF RFID 40x40 mm Square Transceiver Installation Instructions
Allen-Bradley 59RF RFID 40x40 mm Square Transceiver is a versatile RFID transceiver designed for robust industrial applications. It leverages IO-Link V1.1 communication for seamless integration with your automation system and offers read/write speeds up to 26.6 kbit/s. This device is compatible with ICODE ISO 15693 standard tags, providing accurate identification and data exchange. The built-in diagnostics indicators facilitate troubleshooting and ensure reliable performance in harsh environments. Its compact size allows for versatile mounting options, making it suitable for a wide range of applications, including asset tracking, data acquisition, and tool management.
advertisement
Original Instructions
59RF RFID 40x40 mm Square Transceiver
Catalog Number 59RF-TR-4040
Features
• IO-Link V1.1 communication
• Read/write speeds up to 26.6 kbit/s
• ICODE ISO 15693 compliant
• Built-in indicators for diagnostics
• Reliable performance in harsh environments
• Universal mounting
Typical Applications
Minimum Distance Between Transceivers
Read/write modules must not mutually influence each other. For this reason, a
minimum distance (b) between the devices must be observed.
Transceiver/Transponder Recommended
Distances
Specifications
Indicator Illumination Pattern
• Asset tracking • Automotive
• Data acquisition • Food and pharmaceutical
• Product handling • Security and entrance
• Tool management
Item Description Item Description [mm (in.)]
1 Unique transponder zone a 60 (2.36)
2 Sensing face b 120 (4.72)
3 Support c 120 (4.72)
d 10 (0.39)
Transponder Type S max [mm (in.)] S 0 [mm (in.)] D 0 [mm (in.)]
Ø50 mm (1.97 in.) diameter 78 (3.07) 41 (1.61) 80 (3.15)
1
2
3
a b
c
d
D0
S0
S max
Model: 59RF-TR-4040
y x
POWEROUTPUT
Transponder
Working area
when RSSI ≥ 1
Read/write
Module
Attribute 59RF-TR-4040
Supply voltage 11…32V DC
Current consumption, max 200 mA
Tag compatibility ISO 15693
Connector M12 4-pin convex
Communication systems IO-Link V1.1
Communication rate (host) 230,400 bps
Frequency 13.56 MHz
Process data width IN 32 bytes
Process data width OUT 32 bytes
Operating temperature -25…+80 °C (-13…+176 °F)
Storage temperature -25…+80 °C (-13…+176 °F)
Enclosure rating IP68/IP69K
Material (face/body) PBT/chrome-plated brass
Recommended sensing distance(1)
(1) Range reference for 50 mm (1.97 in.) diameter tag.
41 mm (1.61 in.)
Sensing distance, max (1) 78 mm (3.07 in.)
Distance from IO-Link primary, max 20 m (65.6 ft)
Compliance CE, FCC, IC, cULus
Item Description
1
Tag receive signal strength indication
(RSSI) level = RSSI threshold. Transponder
is in read/write mode (RWM) recommended
working area.
2 RWM RSSI threshold limit set in the RWM
configuration parameter menu.
3
Tag RSSI level < RSSI threshold.
Transponder is in RWM maximal sensing
range.
4 Tag is out of RWM sensing range.
Q1/Tag Q2/Busy Error Power
IO-Link SIO IO-Link SIO
ON Area 1 Q1 is ON — Q1 is ON Error
occurred
RWM is ON and
standalone mode
(SIO) is used
OFF Area 4 Q1 is OFF No pending
CMD Q2 is OFF No error RWM is OFF
Blinking
(1 Hz) — — RWM busy — — RWM is ON and IO-
Link mode is used
Blinking
(5 Hz) Area 3
Q1 is tag
present or
compares
Data and
Area 3
—
Q1 is tag
present or
compares
Data and
Area 3
— —
Model: 59RF-TR-4040
S TAG
1 2 3
4
OUTPUT POWER
Q1/Tag Error
Q1/Busy Power
Copyright © 2022 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Allen-Bradley, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
For technical support, visit rok.auto/support.
10005506853 Ver 01
Waste Electrical and Electronic Equipment (WEEE)
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
Connector Pinout
FCC Notice (For U.S. Customers)
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following conditions: (1) This device will not cause harmful interference; and
(2) this device must accept any interference received, including interference that
will cause undesired operation of the device.
Changes and modifications that are not expressly approved by Rockwell
Automation can void your authority to operate this equipment under Federal
Communications Commissions rules.
IC Information
This device complies with the Industry Canada license-exempt RSS standards.
Operation is subject to the following two conditions: (1) this device will not cause
interference; and (2) this device must accept any interference, including
interference that will cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si
le brouillage est susceptible d'en compromettre le fonctionnement
Approximate Dimensions
Dimensions are shown in mm (in.) and are not intended to be used for installation
purposes.
Pin Signal
1 24V DC
2 Data (SIO Q2)
3 0V GND
4 Data (SIO Q1)
IMPORTANT Installation must be in accordance with local and/or
national codes. The service of energized industrial control
equipment can be hazardous if not in accordance to
recommended safety procedures.
4
3
1
2
30 (1.81)
40 (1.58)
M12 x 1
20 (0.79)
40 (1.58)
5.5
(0.22)
46
(1.81)
67
(2.64)
14
(0.55)
1
(0.04)
advertisement
Key Features
- IO-Link V1.1
- Read/Write speeds up to 26.6 kbit/s
- ICODE ISO 15693 compliant
- Built-in indicators
- IP68/IP69K enclosure rating
- Universal mounting
- Recommended sensing distance 41 mm
Related manuals
Frequently Answers and Questions
What kind of tags can be used with this device?
What is the maximum sensing distance of this transceiver?
What is the operating temperature range for this device?
advertisement