Allen-Bradley Dynamix 1443 Series Sensors User Manual

Allen-Bradley Dynamix 1443 Series Sensors User Manual

Allen-Bradley Dynamix 1443 Series Sensors are a family of industrial accelerometers used for vibration measurements on industrial machinery like motors, pumps, fans, gears, and other machines. They are rugged, precision sensors designed for permanent mounting and offer various mounting options, cable lengths, and performance characteristics to meet diverse application needs.

advertisement

Dynamix 1443 Series Sensors
Catalog Numbers 1443-ACC, 1443-CL, 1443-CON, 1443-MAG, 1443-STD, 1443-BLT, 1443-PRB, 1443-PAD, 1443-SFT,
and 1443-KIT
User Manual
Important User Information
Read this document and the documents listed in the additional resources section about installation, configuration, and
operation of this equipment before you install, configure, operate, or maintain this product. Users are required to
familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws,
and standards.

Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required
to be carried out by suitably trained personnel in accordance with applicable code of practice.

If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be
impaired.

In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the
use or application of this equipment.

The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or
liability for actual use based on the examples and diagrams.

No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or
software described in this manual.

Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,
Inc., is prohibited.

Throughout this manual, when necessary, we use notes to make you aware of safety considerations.

Labels may also be on or inside the equipment to provide specific precautions.

Allen-Bradley, Rockwell Software, Dynamix, and Rockwell Automation are trademarks of Rockwell Automation, Inc.

Trademarks not belonging to Rockwell Automation are property of their respective companies.

WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment,
which may lead to personal injury or death, property damage, or economic loss.

ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property
damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.

IMPORTANT
Identifies information that is critical for successful application and understanding of the product.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous
voltage may be present.

BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may
reach dangerous temperatures.

ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to
potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL
Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).
Rockwell Automation Publication 1443-UM001A-EN-P - October 2015 1
Table of Contents

Preface
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Chapter 1

Installation
Sensor Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Types of Sensor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Mount the Sensors Directly on the Case. . . . . . . . . . . . . . . . . . . . . . . . . . 5

Stud Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Screw Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Mounting Sensors with Adhesive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Mount the Sensors with a Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Mount the Sensors with Magnets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Chapter 2

Cables and Cable Guidelines
Sensor Connections and Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Cable Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Cable Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Reducing Electrical Interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Shield Isolated versus Shield Case Grounded Cables . . . . . . . . . . . . . . . . 17

Cable Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Splicing Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Cable Conduit Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Cables in Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Cables Runs to Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Cables Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Chapter 3

Maintenance and Inspection
Periodic Inspection Intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Unit Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Index
2 Rockwell Automation Publication 1443-UM001A-EN-P - October 2015
Table of Contents
Notes:
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
  • Page 21
  • Page 22
  • Page 23
  • Page 24
  • Page 25
  • Page 26
  • Page 27
  • Page 28
/

advertisement

Key Features

  • IEPE sensors
  • Stud mounting
  • Screw mounting
  • Various cable lengths
  • Velocity output
  • Temperature output
  • Hazardous area approved

Related manuals

Frequently Answers and Questions

What are Allen-Bradley Dynamix 1443 Series Sensors used for?
They are industrial accelerometers used to measure vibration on machines like motors, pumps, and gears. They are designed for permanent installation.
What kind of mounting options are available for the sensors?
The manual mentions stud mounting, screw mounting, adhesive mounting, brackets, and magnets. Stud and screw mounting are recommended for permanent installations.
Can the sensors be used in hazardous environments?
Yes, there are hazardous area approved accelerometers within the Dynamix 1443 Series. Refer to the documentation for the specific model certifications.

advertisement