The Allen-Bradley ArmorPoint 24V dc Very High Speed Counter Module, Series A is a versatile, high-speed counting module that is ideal for industrial applications. This IP67-rated module features a sealed M23 connector and can be mounted on a grounded metal surface. The module can be configured for various counter, encoder, and PWM applications, and it includes a variety of input and output filters to meet your specific needs.

advertisement

1 Publication 1738-IN011B-EN-E - August 2013
Installation Instructions

ArmorPOINT 24V DC Very High Speed Counter
Modules, Series A

Catalog number 1738-VHSC24M23

The ArmorPOINT
® I/O family (Bulletin 1738) consists of modular I/O
modules. The sealed IP67 housing of these modules requires no enclosure.
(Note that environmental requirements other than IP67 may require an
additional appropriate housing.) The I/O connector is sealed M23 style. The
mounting base ships with the module. The 1738-VHSC24M23 module is
shown below.

MOD
NET
1738-VHSC24M23/A
24V dc In
A
B
Z
0
1
LED Indicators
43803
1738-VHSC24M23
M23
Connector
Publication 1738-IN011B-EN-E - August 2013
2 ArmorPOINT 24V DC Very High Speed Counter Modules, Series A

.

Important User Information

Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication
SGI-1.1 available from your
local Rockwell Automation sales office or online at
http://www.rockwellautomation.com/literature/) describes some
important differences between solid state equipment and hard-wired electromechanical devices. Because of this
difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying
this equipment must satisfy themselves that each intended application of this equipment is acceptable.

In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting
from the use or application of this equipment.

The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables
and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility
or liability for actual use based on the examples and diagrams.

No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or
software described in this manual.

Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,
Inc. is prohibited.

Throughout this manual we use notes to make you aware of safety considerations.

WARNING
Identifies information about practices or circumstances that can cause an explosion in a hazardous
environment, which may lead to personal injury or death, property damage, or economic loss.

IMPORTANT
Identifies information that is critical for successful application and understanding of the product.
ATTENTION
Identifies information about practices or circumstances that can lead to personal injury or death,
property damage, or economic loss. Attentions help you:

• identify a hazard

• avoid a hazard

• recognize the consequence

SHOCK HAZARD
Labels may be located on or inside the equipment to alert people that dangerous voltage may be
present.

BURN HAZARD
Labels may be located on or inside the equipment to alert people that surfaces may be dangerous
temperatures.
Publication 1738-IN011B-EN-E - August 2013
ArmorPOINT 24V DC Very High Speed Counter Modules, Series A 3

ATTENTION
Environment and Enclosure
This equipment is intended for use in overvoltage Category
II applications (as defined in IEC publication 60664-1), at
altitudes up to 2000 meters without derating.

This equipment is considered Group 1, Class A industrial
equipment according to IEC/CISPR Publication 11.
Without appropriate precautions, there may be potential
difficulties ensuring electromagnetic compatibility in other
environments due to conducted as well as radiated
disturbance.

This equipment is supplied as "enclosed" equipment. It
should not require additional system enclosure when used
in locations consistent with the enclosure type ratings
stated in the Specifications section of this publication.
Subsequent sections of this publication may contain
additional information regarding specific enclosure type
ratings, beyond what this product provides, that are
required to comply with certain product safety
certifications.

NOTE: See NEMA Standards publication 250 and IEC
publication 60529, as applicable, for explanations of the
degrees of protection provided by different types of
enclosure. Also, see the appropriate sections in this
publication, as well as the Allen-Bradley publication
1770-4.1 ("Industrial Automation Wiring and Grounding
Guidelines"), for additional installation requirements
pertaining to this equipment.

ATTENTION
Preventing Electrostatic Discharge
This equipment is sensitive to electrostatic discharge, which
can cause internal damage and affect normal operation.
Follow these guidelines when you handle this equipment:

• Touch a grounded object to discharge potential static.

• Wear an approved grounding wriststrap.

• Do not touch connectors or pins on component
boards.

• Do not touch circuit components inside the equipment.

• If available, use a static-safe workstation.

• When not in use, store the equipment in appropriate
static-safe packaging.
Publication 1738-IN011B-EN-E - August 2013
4 ArmorPOINT 24V DC Very High Speed Counter Modules, Series A

Mount the I/O Base
To mount the ArmorPOINT I/O base on a wall or panel, use the screw holes
provided in the ArmorPOINT base.

A mounting illustration for the ArmorPOINT base with an adapter is shown
below.

IMPORTANT
The ArmorPOINT I/O module must be mounted on a
grounded metal mounting plate or other conductive
surface.

43769
4.02 in.
102 mm
1.81 in.
46 mm
Adapter
1.9 in.
47.2 mm
2.0 in.
50 mm
0.87 in.
22 mm
2.0 in.
50 mm
0.87 in.
22 mm
2.0 in.
50 mm
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
/

advertisement

Key Features

  • High-speed counting
  • IP67 rated
  • M23 connector
  • Configurable for encoder, counter, and PWM applications
  • Input and output filters
  • Sealed housing

Related manuals

Frequently Answers and Questions

What is the maximum input frequency of this module?
The maximum input frequency is 1.0MHz for counter and encoder X1 configurations, 500kHz for encoder X2 configurations (with no filter), and 250kHz for encoder X4 configurations (with no filter).
What are the output control options available?
The outputs can be tied to any of 4 compare windows, and you can configure them for various functions such as ON/OFF control, PWM, and more.
How can I configure the module for my specific application?
The module can be configured using a variety of parameters, including counter configuration, filter selection, decimal position, active output assembly, and more. Refer to the manual for detailed instructions on configuration.

advertisement