Allen-Bradley 931 Passive and Active Converter, Monitoring; Active Isolator, Hall-Effect devices are designed to measure DC, AC and non-sinusoidal currents up to 60A. These modules are suitable for monitoring diverse applications. The measurement circuit is galvanically isolated and the results can be output as a relay contact or analog value. The device also features various configuration options and range adjustments through DIP switches.

advertisement

Installation Instructions 1
Beipackinformation 9
Notice d’utilisation 15
Hoja adicional 21
Foglo informativo 27
Information 33
en
de
fr
es
it
se
DIR 10000043405
(Version 01)
Active Converter, Monitoring
931S-A3C2D-DC
Passive Converter, Monitoring
931S-A3A2D-OP
Active Isolator, Hall-Effect Monitoring
931S-A4C2D-DCHall
10000043405
2






Read these instructions before using the product and retain for future information.
Lesen Sie diese Beipackinformation, bevor Sie das Produkt installieren, und heben Sie
diese fĂ¼r weitere Informationen auf.
Lisez cette notice d'utilisation avant d'installer le produit et gardez cette brochure pour
obtenir des informations additionnelles.
SĂ­rvase leer esta hoja de informaciĂ³n antes de instalar el producto y guĂ¡rdela para
consultas posteriores.
Prima di installare il prodotto leggere il foglio informativo accluso e conservarlo per po-
terlo consultare in caso di necessitĂ .
Läs noga igenom bruksinformationen innan produkten installeras och förvara den väl sĂ¥
att du alltid har den tills hands om du skulle bejöva den.
3
1. General instructions
• Disconnect power prior to installation
• Installation only by Qualified personnel
• Follow all applicable local and national electrical codes
• Observe ESD regulations
Care must be taken to prevent a direct electrostatic discharge
when setting the DIP switches. Regulations of the county in
which the modules are to be operated are to be observed (for
example, Germany, VDE 0100) when selecting and installing
electrical wiring.
2. Application
Current-monitoring modules, measure DC, AC and non-sinusoidal currents
up to 60 A, and can be used for monitoring tasks in diverse areas. All vari-
ables are configured via DIP switches. Further calibration is not necessary.
The measurement circuit is galvanically isolated. Measurement results are
available for further processing as a relay contact or analog value.
WARNINGWARNING
WARNINGWARNING
3. Mounting and Settings
3.1 Range adjustments
1. Remove  connector
2. Press locking clips  on both sides of the enclosure and pull out the
circuit board
3. Make required adjustments to the input range, hysteresis, frequency
and relay control using the DIP switches (by print to the side of the
enclosure ).
4. Replace connector after making adjustments
The connectors have been coded by the manufacturer, ensuring that
they cannot be reversed .
5. If using the feed-through version, push through enclosing wire 
The circuit board can only be inserted in one position.
3.2 Cross-connections for voltage supply 
A maximum feed through of 2 A is possible
The Plug-In Jumper have been coded by the manufacturer, preventing a
short circuit should the cross-connectors be reversed
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
  • Page 21
  • Page 22
  • Page 23
  • Page 24
  • Page 25
  • Page 26
  • Page 27
  • Page 28
  • Page 29
  • Page 30
  • Page 31
  • Page 32
  • Page 33
  • Page 34
  • Page 35
  • Page 36
  • Page 37
  • Page 38
  • Page 39
  • Page 40
/

advertisement

Key Features

  • Current monitoring
  • Galvanic isolation
  • DC, AC and non-sinusoidal currents
  • Relay contact or analog output
  • DIP switch configuration
  • Range adjustments

Related manuals

Frequently Answers and Questions

What types of currents can the Allen-Bradley 931 module measure?
The Allen-Bradley 931 module measures DC, AC and non-sinusoidal currents up to 60A.
How do I configure the device's settings?
The Allen-Bradley 931 module uses DIP switches for configuring various parameters like input range, hysteresis, frequency, and relay control. Refer to the manual for detailed instructions on DIP switch settings.
What is the output of the Allen-Bradley 931 module?
The Allen-Bradley 931 module's measurement results can be output as a relay contact or analog value (0-10V, 0-20mA, or 4-20mA).
What is the maximum current allowed through the feed-through version?
The Allen-Bradley 931 module has feed-through capability and supports a maximum current of 2A.
Does the device require calibration?
No, the Allen-Bradley 931 module does not require calibration. All settings are configured via DIP switches.

advertisement